DRA-40-24 [MEANWELL]

UNIVERSAL AC INPUT/FULL RANGE;
DRA-40-24
型号: DRA-40-24
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

UNIVERSAL AC INPUT/FULL RANGE

输入元件
文件: 总5页 (文件大小:167K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
40W Single Output Switching Power Supply  
DRA-40 series  
Bauart gepruft  
Sicherheit  
egelma ge  
o s  
od  
be wac  
g
www.tuv.com  
ID 2000000000  
LPS  
Features  
Applications  
Universal AC input / Full range  
Protections: Short circuit / Overload / Over voltage  
Can be installed on DIN rail TS-35/7.5 or 15  
Output Voltage adjustable through internal potentiometer  
Output Current adjustable through external 1~10Vdc, PWM  
signal or resistance  
Machine vision inspection system  
Plant cultivation system  
Cooling by free air convection  
Pass LPS  
LED indicator for power on  
100% full load burn-in test  
3 years warranty  
Description  
DRA-40 is one 40W AC/DC DIN rail power supply, featuring the adjustable output current. Users are  
able to easily change the constant output current level, via 1~10Vdc, PWM signal or resistance.  
DRA-40 can be mounted on DIN rail TS-35/7.5 or 15; in addition, the width of the unit is only 40mm that  
it is well suited for the installation in a limited spacing. DRA-40 accepts the universal AC input between  
90VAC and 264VAC; the efficiency is up to 87% that the entire series can operate, under free air convection,  
from -30through 70.  
Model Encoding  
DRA - 40 - 12  
Output voltage  
Output wattage  
Series name  
File Name:DRA-40-SPEC 2015-06-11  
40W Single Output Switching Power Supply  
DRA-40 series  
SPECIFICATION  
MODEL  
DRA-40-12  
DRA-40-24  
DC VOLTAGE  
12V  
24V  
CONSTANT CURRENT REGION 3~12V  
3~24V  
1.7A  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
3.34A  
0 ~ 3.34A  
40.08W  
0 ~ 1.7A  
40.8W  
150mVp-p  
24 ~ 30V  
1.0%  
RIPPLE & NOISE (max.) Note.2 120mVp-p  
OUTPUT VOLTAGE ADJ. RANGE  
12 ~ 15V  
1.0%  
VOLTAGE TOLERANCE Note.3  
LINE REGULATION  
0.5%  
0.5%  
LOAD REGULATION  
0.5%  
0.5%  
SETUP, RISE TIME Note.4 400ms, 90ms/230VAC  
800ms, 90ms/115VAC at full load  
HOLD UP TIME (Typ.)  
VOLTAGE RANGE  
50ms/230VAC  
90 ~ 264VAC  
47 ~ 63Hz  
85%  
10ms/115VAC at full load  
127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]  
FREQUENCY RANGE  
EFFICIENCY (Typ.)  
AC CURRENT (Typ.)  
87%  
INPUT  
0.8A/115VAC  
0.6A/230VAC  
INRUSH CURRENT (Typ.) COLD START 30A/115VAC  
60A/230VAC  
95 ~ 108% rated output power  
OVERLOAD  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
14.49 ~ 18.63V  
28.98 ~ 37.26V  
PROTECTION  
ENVIRONMENT  
OVER VOLTAGE  
Protection type : Shut down o/p voltage, re-power on to recover  
-30 ~ +70(Refer to "Derating Curve")  
20 ~ 90% RH non-condensing  
WORKING TEMP.  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
-40 ~ +85, 10 ~ 95% RH  
0.03%/(0 ~ 55) on output  
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
UL60950-1, TUV EN60950-1 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
EMC EMISSION  
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC  
SAFETY &  
EMC  
(Note 5)  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH  
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3  
EMC IMMUNITY  
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A  
439.3K hrs min. MIL-HDBK-217F (25)  
MTBF  
40*90*100mm (W*H*D)  
OTHERS DIMENSION  
PACKING  
0.3Kg; 42pcs/13.6Kg/0.82CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
NOTE  
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.  
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed  
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power  
supplies.” (as available on http://www.meanwell.com)  
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded  
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.  
File Name:DRA-40-SPEC 2015-06-11  
40W Single Output Switching Power Supply  
DRA-40 series  
Block Diagram  
RECTIFIERS  
RECTIFIERS  
+V  
-V  
POWER  
EMI  
I/P  
&
&
SWITCHING  
FILTER  
FILTER  
FILTER  
DIM+  
O.C.P.  
DIM-  
DETECTION  
CIRCUIT  
FG  
CONTROL  
O.L.P.  
O.V.P.  
Derating Curve  
Static Characteristics  
100  
90  
80  
70  
60  
50  
40  
100  
80  
230VAC  
Input only  
60  
40  
20  
-30  
-20  
0
15  
30  
40  
50 55 60  
70  
(VERTICAL)  
90 100 125 135 145 155 165 175 180 200 230 264  
INPUT VOLTAGE (V) 60Hz  
AMBIENT TEMPERATURE ()  
OUTPUT CURRENT ADJUSTMENT OPERATION  
Built-in 3 in 1 current adjustment function . Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM  
signal or resistance between DIM+ and DIM-.  
Please DO NOT connect "DIM-" to "-V".  
Reference resistance value for output current adjustment (Typical)  
Single Power supply  
10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ  
10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N  
OPEN  
-----  
Resistance  
value  
Multiple Power supplies  
(N=Power supply quantity for simultaneous  
current adjustment control)  
Percentage of rated current  
10%  
20%  
30%  
40%  
50%  
60%  
70%  
80%  
90%  
100% 102%~108%  
1 ~ 10Vdc for output current adjustment (Typical)  
Applied Source  
1V  
2V  
3V  
4V  
5V  
6V  
7V  
8V  
9V  
10V  
OPEN  
Percentage of rated current  
10%  
20%  
30%  
40%  
50%  
60%  
70%  
80%  
90% 100% 102%~108%  
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz  
Duty value  
10%  
10%  
20%  
20%  
30%  
30%  
40%  
40%  
50%  
50%  
60%  
60%  
70%  
70%  
80%  
80%  
90% 100%  
OPEN  
Percentage of rated current  
90% 100% 102%~108%  
File Name:DRA-40-SPEC 2015-06-11  
40W Single Output Switching Power Supply  
DRA-40 series  
Using the current adjustment function can not adjust the output current to 0A. Please refer to the connection method below to a  
djust the output  
current to 0A.  
10K~100K Ohms resistance  
1~10V DC Voltage  
LOAD  
10V PWM Signal  
Adjuster  
+V +V -V -V  
DC OK  
Switch  
+
+V ADJ  
Relay  
N
L
L
FG N  
DRIVING METHODS OF APPLICATIONS  
The power supply may either work in "constant voltage mode or constant current mode"  
In the constant current region, the highest voltage at the output of the driver  
Rated  
output  
voltage  
depends on the configuration of the end systems.  
Should there be any compatibility issues, please contact MEAN WELL.  
(B)  
Constant  
Current area  
(A) Constant  
Voltage area  
3V  
(C)  
Hiccup  
Protection  
50  
100  
Io (%)  
File Name:DRA-40-SPEC 2015-06-11  
40W Single Output Switching Power Supply  
DRA-40 series  
Mechanical Specification  
Case No.962A Unit:mm  
100  
40  
5
5
5
5
5
+V +V -V -V  
DC OK  
+
+V ADJ  
N
L
7.5 7.5  
Installation Instruction  
This series fits DIN rail TS35/7.5 or TS35/15.  
For installation details, please refer to the USER MANUAL on  
http://www.meanwell.com/search/DRA-40/DRA_manual.pdf  
(This diagram is for reference. The rail is not included with unit.)  
Back View  
File Name:DRA-40-SPEC 2014-10-22  

相关型号:

DRA-60

UNIVERSAL AC INPUT/FULL RANGE
MEANWELL

DRA-60-12

UNIVERSAL AC INPUT/FULL RANGE
MEANWELL

DRA-60-24

UNIVERSAL AC INPUT/FULL RANGE
MEANWELL

DRA-CN024D05

6.2mm Din-Rail Mount (35 mm) SSR Assembly
CRYDOM

DRA-CN024D05R

DIN Rail Mount
CRYDOM

DRA-CN024D120

RELAY SSR 3.5A 24VDC DIN-RAIL
ETC

DRA-CN024D24

6.2mm Din-Rail Mount (35 mm) SSR Assembly
CRYDOM

DRA-CN024D240

RELAY SSR 3.5A 24VDC DIN-RAIL
ETC

DRA-CN024D24R

DIN Rail Mount
CRYDOM

DRA-CN024DR

6.2mm Din-Rail Mount (35 mm) SSR Assembly
CRYDOM

DRA-CN048D05

6.2mm Din-Rail Mount (35 mm) SSR Assembly
CRYDOM

DRA-CN048D05R

DIN Rail Mount
CRYDOM