MBR20035CT [MCC]
200 Amp Rectifier 20 to 100 Volts Schottky Barrier; 200安培整流器20到100伏特肖特基势垒![MBR20035CT](http://pdffile.icpdf.com/pdf1/p00070/img/icpdf/MBR20035_369114_icpdf.jpg)
型号: | MBR20035CT |
厂家: | ![]() |
描述: | 200 Amp Rectifier 20 to 100 Volts Schottky Barrier |
文件: | 总3页 (文件大小:412K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MBR20020CT
M C C
ꢀꢁꢂꢃꢄꢅꢆꢄꢇꢇꢈꢃꢂꢁꢉꢊꢅꢆomponents
21201 Itasca Street Chatsworth
ꢆꢋꢅꢌꢍꢎꢍꢍ
ꢏꢐꢄꢑꢈꢒꢅꢓꢔꢍꢔ ꢅ!ꢕꢍ"#ꢌꢎꢎ
$ꢉ%ꢒꢅ ꢅ ꢅ ꢓꢔꢍꢔ ꢅ!ꢕꢍ"#ꢌꢎꢌ
THRU
MBR200100CT
200 Amp
Schottky Barrier
Rectifier
Features
·
·
·
·
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
20 to 100 Volts
High surge capacity, High current capability
Maximum Ratings
FULL PACK
•
•
Operating Temperature: -55°C to +175°C
Storage Temperature: -55°C to +175°C
Maximum
Recurrent
Maximum DC
Blocking
A
MCC
Maximum
B
K
Part Number Peak Reverse RMS Voltage
Voltage
Voltage
C
MBR20020CT
MBR20030CT
MBR20035CT
MBR20040CT
MBR20045CT
MBR20060CT
MBR20080CT
MBR200100CT
20V
30V
35V
40V
45V
60V
80V
100V
14V
21V
24.5V
28V
31.5V
42V
56V
20V
30V
35V
40V
45V
60V
80V
100V
M
F
L
J
D
H
70V
E
G
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
IF(AV)
200 A
TC = 136°C
DIMENSIONS
IFSM
1500A 8.3ms, half sine
MM
INCH
MIN
ES
DIM
MAX
NOM
1.585
.800
2.500
.132
MIN
MAX
NOTE
A
B
C
D
E
F
G
H
J
3.150
1.565
.700
2.400
.119
80.01
39.75
17.78
60.96
3.02
NOM
40.26
20.32
63.50
3.35
Maximum
Instantaneous
Forward Voltage
20020-20045CT
20060CT
20080-200100CT
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
FM = 100 A;
TJ = 25°C
1.375 REF
34.92 REF
VF
.68 V
.75 V
.84 V
3.550
.580
3.650
90.17
92.71
15.75
.620
1/4 -20 UNF
.410
14.73
FULL
K
.380
.185
.275
9.65
4.70
6.99
10.41
4.95
7.49
L
M
.195
.295
IR
5 mA
75 mA
TJ = 25°C
TJ = 125°C
Typical Junction
Capacitance
CJ
4600pF Measured at
1.0MHz, VR=5.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
www.mccsemi.com
MBR20020CT thru MBR200100CT
M C C
Figure 1
Typical Forward Characteristics
2000
Figure 2
Forward Derating Curve
MBR20060CT
MBR20020CT-20045CT
1000
600
200
160
120
80
400
200
MBR20080CT-200100CT
25°C
100
60
Amps
Amps
40
40
20
20
10
6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
70
90
°C
110
130
150
4
0
2
1
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
0.2
0.4
0.
1.2
6
0.8
1.0
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
10000
6000
4000
2000
TJ=25°C
pF
1000
600
400
200
100
.1
.2
.4
1
2
10 20
200 400
1000
4
40
100
Volts
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.mccsemi.com
MBR20020CT thru MBR200100CT
M C C
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
1000
600
1500
400
1200
200
900
600
300
100
60
Amps
40
100
20
0
TJ=125°C
80
100
1
6
60
4
8 10 20
Cycles
40
2
10
6.0
4.0
mAmps
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
2.0
1.0
.6
.4
TJ=25°C
40
.2
.1
10
60
20
120
80
100
Volts
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com
相关型号:
©2020 ICPDF网 联系我们和版权申明