MAX1823BEUB-T [MAXIM]

Power Supply Support Circuit, Fixed, 1 Channel, BICMOS, PDSO10, MICRO, SOP-10;
MAX1823BEUB-T
型号: MAX1823BEUB-T
厂家: MAXIM INTEGRATED PRODUCTS    MAXIM INTEGRATED PRODUCTS
描述:

Power Supply Support Circuit, Fixed, 1 Channel, BICMOS, PDSO10, MICRO, SOP-10

信息通信管理 光电二极管
文件: 总12页 (文件大小:358K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
19-1903; Rev 2; 10/02  
Dual USB Switch with Fault  
Blanking and Autoreset  
General Description  
Features  
Dual USB Switch in Tiny 10-Pin µMAX Package  
Autoreset Feature Saves Power  
The MAX1823 is a dual, current-limited switch with  
autoreset specifically made for USB applications. The  
autoreset feature latches the switch off if the output is  
shorted, saving system power. The switch reactivates  
when the short-circuit condition is removed. Each channel  
is guaranteed to supply 720mA and meet USB specifica-  
tions. The device’s low quiescent supply current (50µA)  
and standby current (3µA) conserve battery power in  
portable applications.  
Guaranteed 720mA Load per Channel  
Built-In 20ms Fault Blanking  
Compliant to USB Specification  
4V to 5.5V Input Voltage Range  
Independent Shutdown Control  
(MAX1823—Active Low)  
The MAX1823 has multiple safety features to ensure that  
the USB port is protected. Built-in thermal-overload pro-  
tection limits power dissipation and junction temperature.  
The device also has accurate internal current-limiting cir-  
cuitry to protect the input supply against both overload  
and short-circuit conditions. Independent fault signals  
(FAULTA and FAULTB) notify the microprocessor (µP)  
when a thermal-overload, current-limit, undervoltage  
lockout (UVLO), or short-circuit fault occurs. A 20ms  
fault-blanking feature enables the circuit to ignore  
momentary faults, such as those caused when hot  
swapping a capacitive load, preventing false alarms to  
the host system.  
(MAX1823H—Active High)  
Independent FAULT Indicator Outputs  
Thermal-Overload Protection  
50µA Quiescent Current (Both Switches On)  
3µA Standby Current  
UL Listing Pending  
The MAX1823 is available in a space-saving 10-pin  
µMAX. The MAX1823 is enabled with an active-low signal  
and the MAX1823H is enabled with an active-high signal.  
For a dual switch without autoreset, refer to the MAX1812  
data sheet. For single versions of this device, refer to the  
MAX1693, MAX1694, and MAX1607 data sheets.  
Ordering Information  
PART  
TEMP RANGE  
-40°C to +85°C  
-40°C to +85°C  
PIN-PACKAGE  
10 µMAX  
MAX1823EUB  
MAX1823HEUB  
10 µMAX  
Applications  
USB Ports and Hubs  
Notebook and Desktop Computers  
PDAs and Palmtop Computers  
Docking Stations  
Pin Configuration  
Typical Operating Circuit  
USB  
PORT A  
TOP VIEW  
INA  
IN  
OUTA  
INPUT  
4V TO 5.5V  
INB  
ONA  
1
2
3
4
5
10 FAULTA  
MAX1823  
INA  
IN  
9
8
7
6
OUTA  
GND  
MAX1823  
USB  
PORT B  
FAULTA  
FAULTB  
OUTB  
INB  
ONB  
OUTB  
FAULTB  
ONA  
ONB  
ONA  
ONB  
GND  
MAX  
________________________________________________________________ Maxim Integrated Products  
1
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at  
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.  
Dual USB Switch with Fault  
Blanking and Autoreset  
ABSOLUTE MAXIMUM RATINGS  
IN, INA, INB, ONA, ONB, ONA, ONB  
OUTA, OUTB to GND...............................................-0.3V to +6V  
Continuous Power Dissipation (T = +70 C)  
10-Pin µMAX (derate 5.6mW/ C above +70 C)...............444mW  
A
Operating Temperature Range ...........................-40 C to +85 C  
Junction Temperature......................................................+150 C  
Storage Temperature Range.............................-65 C to +150 C  
Lead Temperature (soldering, 10s) .................................+300 C  
FAULTA, FAULTB to GND..........................-0.3V to (V  
INA, IN to OUTA; INB, IN to OUTB...........................-0.3V to +6V  
OUTA, OUTB Maximum Continuous Switch Current  
(per channel, internally limited) .........................................1.2A  
FAULTA, FAULTB Current .................................................20mA  
+ 0.3V)  
IN_  
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional  
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to  
absolute maximum rating conditions for extended periods may affect device reliability.  
ELECTRICAL CHARACTERISTICS  
(Circuit of Figure 1, V = V  
= V = 5V, ONA = ONB = GND (MAX1823), ONA = ONB = IN (MAX1823H), T = 0 C to +85 C, unless  
INB A  
IN  
INA  
otherwise noted. Typical values are at T = +25 C.)  
A
PARAMETER  
SYMBOL  
CONDITIONS  
= +25oC, each switch  
MIN  
TYP  
MAX  
5.5  
UNITS  
Supply Voltage Range  
4.0  
V
T
T
75  
105  
135  
10  
A
A
Switch On-Resistance  
Standby Supply Current  
R
m
ON  
= 0oC to +85oC, each switch  
ON_ = IN_ (MAX1823), ON_ = GND (MAX1823H)  
3
40  
µA  
ON_ = IN_ (MAX1823), ON_ = GND  
80  
(MAX1823H) I  
= I  
OUTB  
= 0  
Quiescent Supply Current  
µA  
µA  
OUTA  
I
= I  
OUTB  
= 0  
50  
100  
1.00  
OUTA  
ON_ = IN_ (MAX1823), ON_ = GND (MAX1823H)  
= V  
= 0, T = +25oC  
0.02  
V
OUTA  
OUTB  
A
OUT_ Off-Leakage Current  
ON_ = IN_ (MAX1823), ON_ = GND  
(MAX1823H)  
0.02  
3.4  
10.00  
3.8  
V
= V  
= 0, T = 0oC to +85oC  
OUTB A  
OUTA  
Undervoltage Lockout Threshold  
Continuous Load Current  
Continuous Current Limit  
V
Rising edge, 3% hysteresis  
3.0  
720  
0.72  
0.8  
V
mA  
UVLO  
I
V
V
V
- V  
= 0.5V  
0.90  
1.2  
0.35  
1
1.20  
1.6  
A
LIM  
IN  
OUT_  
= 0 (I  
pulsing)  
A(peak)  
OUT_  
OUT_  
OUT  
OUT  
Short-Circuit Current Limit  
I
SHORT  
= 0 (I  
pulsing)  
A
RMS  
V
Short-Circuit Detect Threshold  
(Note 1)  
Continuous Current-Limit  
Blanking Timeout Period  
From continuous current-limit condition to  
FAULT_ assertion  
10  
20  
18  
35  
35  
ms  
ms  
Short-Circuit Blanking Timeout  
Period  
From short-circuit current-limit condition to  
FAULT_ assertion  
7.5  
R
_ = 10 , does not include rise time  
OUT  
(from ON_ (MAX1823) or ON_ (MAX1823H)  
asserted to V = 10% V  
Turn-On Delay  
0.5  
1.2  
2.5  
0.8  
4.0  
3.0  
ms  
ms  
ms  
)
IN_  
OUT  
Output Rise Time  
R
= 10 , from 10% to 90% of V  
OUT_  
OUT_  
R
= 10 , does not include fall time  
OUT_  
(from ON_ (MAX1823) or ON_ (MAX1823H)  
deasserted to V = 90% of V  
Turn-Off Delay from ON  
)
IN_  
OUT  
2
_______________________________________________________________________________________  
Dual USB Switch with Fault  
Blanking and Autoreset  
ELECTRICAL CHARACTERISTICS (continued)  
(Circuit of Figure 1, V = V  
= V = 5V, ONA = ONB = GND (MAX1823), ONA = ONB = IN (MAX1823H), T = 0 C to +85 C, unless  
INB A  
IN  
INA  
otherwise noted. Typical values are at T = +25 C.)  
A
PARAMETER  
Output Fall Time  
SYMBOL  
CONDITIONS  
MIN  
TYP  
2.5  
MAX  
UNITS  
R
= 10 , from 10% to 90% of V  
15oC hysteresis  
ms  
oC  
V
OUT_  
OUT_  
Thermal Shutdown Threshold  
Logic Input High Voltage  
Logic Input Low Voltage  
160  
V
V
= 4V to 5.5V  
= 4V to 5.5V  
2
IN_  
IN_  
0.8  
1
V
ON_ = GND or IN_ (MAX1823), ON_ = GND  
or IN_ (MAX1823H)  
Logic Input Current  
-1  
µA  
V
FAULT_ Output Low Voltage  
I
= 1mA, V _ = 4V  
0.4  
1
SINK  
IN  
FAULT_ Output High Leakage  
Current  
V
_ = V  
= 5.5V  
µA  
IN  
FAULT_  
Autoreset OUT_ Current  
Autoreset Threshold  
In latched-off state, V  
= 0  
10  
0.4  
10  
25  
0.5  
20  
45  
0.6  
35  
mA  
V
OUT_  
In latched-off state, rising  
In latched-off state, V  
Autoreset Blanking Time  
> 0.5V  
ms  
OUT_  
ELECTRICAL CHARACTERISTICS  
(Circuit of Figure 1, V = V _ = V _ = 5V (MAX1823H); V = V _ = 5V, ON_ = GND (MAX1823), T = -40 C to +85 C, unless oth-  
IN  
IN  
ON  
IN  
IN  
A
erwise noted.) (Note 2)  
PARAMETER  
Supply Voltage Range  
Switch On-Resistance  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
5.5  
UNITS  
4.0  
V
R
Each switch  
135  
m
ON  
ON_ = IN_ (MAX1823), ON_ = GND  
(MAX1823H)  
Standby Supply Current  
10  
80  
µA  
µA  
ON_ = IN_ (MAX1823), ON_ = GND  
(MAX1823H) I  
= I  
OUTB  
= 0  
OUTA  
Quiescent Supply Current  
ON_ = IN_ (MAX1823), ON_ = GND  
(MAX1823H) I = I = 0  
100  
OUTA  
OUTB  
ON_ = IN_ (MAX1823), ON_ = GND  
OUT_ Off-Leakage Current  
(MAX1823H)  
10  
µA  
V
= V  
= 0  
OUTA  
OUTB  
Undervoltage Lockout Threshold  
Continuous Load Current  
V
Rising edge, 3% hysteresis  
3.0  
720  
0.72  
0.8  
3.8  
V
mA  
A
UVLO  
Continuous Current Limit  
I
V
V
- V = 0.5V  
OUT_  
1.20  
1.6  
LIM  
IN_  
Current Limit into Short Circuit  
I
= 0 (I  
pulsing)  
A
SHORT  
OUT_  
OUT  
PEAK  
Continuous Current-Limit  
Blanking Timeout Period  
From continuous current-limit condition to  
FAULT_ assertion  
10  
35  
ms  
Short-Circuit Blanking Timeout  
Period  
From short-circuit current-limit condition to  
FAULT_ assertion  
7.5  
35.0  
ms  
ms  
R
= 10 , does not include rise time  
OUT_  
Turn-On Delay  
(from ON_ (MAX1823) or ON_ (MAX1823H)  
asserted to V = 10% V  
0.5  
4.0  
)
IN_  
OUT_  
_______________________________________________________________________________________  
3
Dual USB Switch with Fault  
Blanking and Autoreset  
ELECTRICAL CHARACTERISTICS (continued)  
(Circuit of Figure 1, V = V _ = V _ = 5V (MAX1823H); V = V _ = 5V, ON_ = GND (MAX1823) T = -40 C to +85 C, unless oth-  
IN  
IN  
ON  
IN  
IN  
A
erwise noted.) (Note 2)  
PARAMETER  
SYMBOL  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
R
= 10 , does not include fall time  
OUT_  
(from ON_ (MAX1823) or ON_ (MAX1823H)  
deasserted to V = 90% V  
Turn-Off Delay from ON  
3
ms  
)
IN_  
OUT_  
Logic Input High Voltage  
Logic Input Low Voltage  
Logic Input Current  
V
V
V
= 4V to 5.5V  
2
V
V
IN_  
IN_  
= 4V to 5.5V  
0.8  
+1  
0.4  
= 0 or V  
-1  
µA  
V
ON_  
SINK  
IN_  
FAULT_ Output Low Voltage  
I
= 1mA, V  
= 4V  
IN_  
FAULT_ Output High Leakage  
Current  
V
= V  
= 5.5V  
FAULT_  
1
µA  
IN_  
Autoreset OUT_Current  
Autoreset Threshold  
In latched-off state, V  
= 0  
10  
0.4  
10  
50  
0.6  
35  
mA  
V
OUT_  
In latched-off state, rising  
In latched-off state, V  
Autoreset Blanking Time  
> 0.5V  
ms  
OUT_  
Note 1: The output voltage at which the device transitions from short-circuit current limit to continuous current limit.  
Note 2: Specifications to -40 C are guaranteed by design, not production tested.  
Typical Operating Characteristics  
(Circuit of Figure 1, V = V  
= V  
= 5V, ON_ = GND (MAX1823), ON_ = IN_ (MAX1823H), T = +25 C, unless otherwise noted.)  
IN  
INA  
INB  
A
QUIESCENT CURRENT  
vs. TEMPERATURE  
vs. TEMPERATURE  
QUIESCENT CURRENT  
vs. INPUT VOLTAGE  
SHUTDOWN SUPPLY CURRENT  
60  
54  
48  
42  
55  
53  
51  
49  
47  
45  
3.5  
3.3  
3.1  
2.9  
2.7  
2.5  
ON_ = IN_ (MAX1823)  
ON_ = GND (MAX1823H)  
V
_
= 5.5V  
IN  
36  
30  
V
_
= 5V  
IN  
24  
18  
12  
6
V
_
= 4.5V  
IN  
0
0
1
2
3
4
5
6
-40  
-15  
10  
35  
60  
85  
-40  
-15  
10  
35  
60  
85  
INPUT VOLTAGE (V)  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
4
_______________________________________________________________________________________  
Dual USB Switch with Fault  
Blanking and Autoreset  
Typical Operating Characteristics (continued)  
(Circuit of Figure 1, V = V  
= V  
= 5V, ON_ = GND (MAX1823), ON_ = IN_ (MAX1823H), T = +25 C, unless otherwise noted.)  
IN  
INA  
INB  
A
CONTINUOUS CURRENT-LIMIT  
THRESHOLD vs. TEMPERATURE  
SWITCH OFF-LEAKAGE  
vs. TEMPERATURE  
NORMALIZED RON vs. TEMPERATURE  
1000  
100  
1.50  
1.25  
1.00  
0.75  
0.50  
940  
930  
920  
910  
900  
ON_ = IN_ (MAX1823)  
ON_ = GND (MAX1823H)  
V
IN_ = 5.5V  
10  
1
V
IN_ = 5V  
V
IN_ = 4.5V  
0.1  
0.01  
-40  
-15  
10  
35  
60  
85  
-40  
-15  
10  
35  
60  
85  
-40  
-15  
10  
35  
60  
85  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
TURN-OFF TIME  
vs. TEMPERATURE  
FAULT-BLANKING TIME  
vs. TEMPERATURE  
TURN-ON TIME  
vs. TEMPERATURE  
3.5  
3.3  
3.1  
2.9  
2.7  
2.5  
22.0  
21.8  
21.6  
21.4  
21.2  
21.0  
4.0  
3.8  
3.6  
3.4  
3.2  
3.0  
V
_ = 4.5V  
IN  
V
_ = 5V  
IN  
V
_ = 5.5V  
IN  
V
_ = 4.5V  
IN  
V
_ = 5V  
IN  
V
_ = 5V  
IN  
V
_
IN  
= 5.5V  
35  
V
_
IN  
= 5.5V  
-15  
V
_
IN  
= 4.5V  
-40  
-15  
10  
35  
60  
85  
-40  
-15  
10  
60  
85  
-40  
10  
35  
60  
85  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
AUTORESET CURRENT  
vs. TEMPERATURE  
AUTORESET CURRENT  
vs. INPUT VOLTAGE  
FAULT_ OUTPUT LOW VOLTAGE  
vs. TEMPERATURE  
40  
35  
30  
25  
20  
15  
0.250  
0.225  
0.200  
0.175  
0.150  
0.125  
0.100  
50  
40  
30  
20  
10  
0
I
_ = 1mA  
FAULT  
T
= -40 C  
A
V
_ = 5.5V  
IN  
V
_ = 5V  
IN  
T
= +25 C  
A
V
_ = 4.5V  
IN  
T
= +85 C  
A
V
_ = 5.5V  
IN  
V
_ = 5V  
IN  
V
_ = 4.5V  
IN  
-40  
-15  
10  
35  
60  
85  
3.6  
4.4  
5.2  
6.0  
-40  
-15  
10  
35  
60  
85  
TEMPERATURE ( C)  
TEMPERATURE ( C)  
INPUT VOLTAGE (V)  
_______________________________________________________________________________________  
5
Dual USB Switch with Fault  
Blanking and Autoreset  
Typical Operating Characteristics (continued)  
(Circuit of Figure 1, V = V  
= V  
= 5V, ON_ = GND (MAX1823), ON_ = IN_ (MAX1823H), T = +25 C, unless otherwise noted.)  
IN  
INA  
INB  
A
OVERLOAD RESPONSE INTO 2.5  
OVERLOAD RESPONSE INTO 2.5  
(EXPANDED TIME SCALE)  
SHORT-CIRCUIT RESPONSE INTO 0  
MAX1823 toc14  
MAX1823 toc13  
MAX1823 toc15  
A
B
5V  
0
5V  
0
5V  
0
A
B
C
A
B
C
D
C
D
0
0
0
0
0
0
D
500 s/div  
C: V  
10ms/div  
C: V  
10ms/div  
C: V  
A: V , 5V/div  
, 5V/div  
FAULTA  
A: V , 5V/div  
, 5V/div  
IN_  
IN_  
FAULTA  
, 1A/div  
A: V _, 5V/div  
, 5V/div  
FAULTA  
IN  
B: V  
, 5V/div  
D: I  
, 1A/div  
B: V  
, 5V/div D: I  
OUTA  
OUTA  
OUTA  
OUTA  
B: V  
, 5V/div  
D: I  
, 1A/div  
OUTA  
OUTA  
SWITCH TURN-ON TIME  
(MAX1823)  
SHORT-CIRCUIT RESPONSE INTO 0  
(EXPANDED TIME SCALE)  
MAX1823 toc17  
MAX1823 toc16  
A
5V  
A
B
0
B
0
5V  
C
D
0
0
1ms/div  
500 s/div  
A: V , 5V/div  
ONA  
A: V , 5V/div  
C: V  
, 5V/div  
IN_  
OUTA  
FAULTA  
B: V  
, 2V/div  
OUTA  
B: V  
, 5V/div  
D: I  
, 2A/div  
OUTA  
6
_______________________________________________________________________________________  
Dual USB Switch with Fault  
Blanking and Autoreset  
Typical Operating Characteristics (continued)  
(Circuit of Figure 1, V = V  
= V  
= 5V, ON_ = GND (MAX1823), ON_ = IN_ (MAX1823H), T = +25 C, unless otherwise noted.)  
IN  
INA  
INB  
A
STARTUP TIME  
(TYPICAL USB APPLICATION)  
SWITCH TURN-OFF TIME  
MAX1823 toc19  
MAX1823 toc18  
A
B
0
A
B
0
5V  
C
D
0
0
0
500 s/div  
C: V , 2V/div  
OUTA  
1ms/div  
A: V , 5V/div  
A: V , 5V/div  
OUTA  
ONA  
ONA  
B: V  
, 5V/div  
D : I  
, 0.5A/div  
B: V  
, 2V/div  
FAULTA  
OUTA  
Pin Description  
PIN  
NAME  
FUNCTION  
ONA  
*(ONA)  
Control Input for Switch A. Can be driven higher than IN_ without damage. A logic low turns switch A on for  
the MAX1823, and a logic high turns switch A on for the MAX1823H.  
1
INA, IN,  
INB  
Power Input. Connect all IN_ pins together, and bypass with a 0.1µF capacitor to ground. Load  
conditions may require additional bulk capacitance to prevent the input from being pulled down.  
2, 3, 4  
ONB  
*(ONB)  
Control Input for Switch B. Can be driven higher than IN_ without damage. A logic low turns switch B  
on for the MAX1823, and a logic high turns switch B on for the MAX1823H.  
5
6
Fault Indicator Output for Switch B. This open-drain output goes low when switch B is in thermal  
shutdown or UVLO or in a sustained (>20ms) current-limit or short-circuit condition.  
FAULTB  
Power Output for Switch B. Connect a 1µF capacitor from OUTB to ground. Load condition may  
require additional bulk capacitance.  
7
8
9
OUTB  
GND  
Ground  
Power Output for Switch A. Connect a 1µF capacitor from OUTA to ground. Load condition may  
require additional bulk capacitance.  
OUTA  
Fault Indicator Output for Switch A. This open-drain output goes low when switch A is in thermal  
shutdown or UVLO or in a sustained (>20ms) current-limit or short-circuit condition.  
10  
FAULTA  
*() are for MAX1823H only  
_______________________________________________________________________________________  
7
Dual USB Switch with Fault  
Blanking and Autoreset  
can also be reset from fault manually by toggling ON_  
(ON_ for MAX1823H) for that channel.  
Detailed Description  
The MAX1823 is a dual current-limited switch designed  
for USB applications. It has two independent switches,  
each with its own enable control input and autoreset  
function. Each switch has an error-flag output to notify  
the USB controller when the current limit, short circuit,  
undervoltage lockout, or thermal shutdown threshold is  
reached (Figure 2.)  
Thermal Shutdown  
The MAX1823 features independent thermal shutdown  
for each switch channel, allowing one switch to deliver  
power even if the other switch has a fault condition.  
When the junction temperature exceeds +160 C, the  
switch turns off, and the FAULT_ output goes low  
immediately; fault blanking does not occur during ther-  
mal limit. When the junction cools by 15 C, the switch  
turns on again. If the fault overload condition continues,  
the switch cycles on and off, resulting in a pulsed out-  
put, saving battery power.  
The MAX1823 operates from a 4V to 5.5V input voltage  
range and guarantees a minimum 720mA output cur-  
rent. A built-in 0.9A current limit limits the current in the  
event of a heavy overload condition. The MAX1823 has  
independent thermal shutdown for each switch in the  
event of a prolonged overload or short-circuit condition.  
The autoreset function monitors the overload and auto-  
matically turns the switch on when the overload is  
removed.  
Fault Indicators  
The MAX1823 provides an open-drain fault output  
(FAULT_) for each switch. For most applications, con-  
nect FAULT_ to IN_ through a 100k pullup resistor.  
FAULT_ goes low when any of the following conditions  
occur:  
Use of low R  
NMOS switches enables the MAX1823  
ON  
to provide two switches in the ultra-small 10-pin µMAX  
package. An internal micropower charge pump gener-  
ates the high-side supply needed for driving the gates  
of these high-side switches. Separate current limiting  
and thermal shutdown circuits permit each switch to  
operate independently, improving system robustness.  
The input voltage is below the UVLO threshold.  
The switch junction temperature exceeds the  
+160 C thermal shutdown temperature limit.  
The switch is in current-limit or short-circuit limit  
mode after the fault-blanking period is exceeded.  
Undervoltage Lockout and  
Input Voltage Requirements  
The switch is in autoreset mode.  
The MAX1823 includes a UVLO circuit to prevent erro-  
neous switch operation when the input voltage goes  
low during startup and brown-out conditions. Operation  
After the fault condition is removed, the FAULT_ output  
deasserts after a 20ms delay. Ensure that the MAX1823  
has adequate input bypass capacitance to prevent  
glitches from triggering FAULT_ outputs. Input glitches  
greater than 0.2V/µs may cause erroneous FAULT_  
indications.  
is inhibited when V  
is less than 3.4V.  
IN_  
Output Fault Protection  
The MAX1823 senses the switch output voltage and  
selects continuous current limiting when V  
is  
OUT  
greater than 1V or short-circuit current limiting when  
is less than 1V. When V is greater than 1V,  
V
OUT  
OUT  
USB  
INA  
IN  
OUTA  
the device operates in a continuous current-limit mode  
that sets the output current limit to 0.9A. When V is  
PORT A  
1 F*  
OUT  
INPUT  
4V TO 5.5V  
INB  
less than 1V, the device operates in short-circuit cur-  
0.1 F  
rent-limit mode, sourcing 0.35A  
the load.  
current pulses to  
RMS  
100k  
MAX1823  
USB  
100k  
Autoreset Mode  
FAULTA  
FAULTB  
OUTB  
PORT B  
If an output fault is detected for more than the 20ms  
blanking time, the output latches off, the FAULT_ output  
goes low, and a 25mA current is forced at the output. If  
the voltage on the output exceeds 0.5V for 20ms, the  
fault resets, the 25mA current source shuts down, and  
the output turns on. The device monitors the output  
voltage so that a short-circuit condition can be detect-  
ed. Active loads are not expected to have measurable  
currents when the supply is below 0.5V. The MAX1823  
1 F*  
ONA  
ONB  
ONA  
ONB  
GND  
* USB APPLICATIONS MAY REQUIRE  
ADDITIONAL BULK CAPACITANCE.  
Figure 1. Typical Application Circuit  
8
_______________________________________________________________________________________  
Dual USB Switch with Fault  
Blanking and Autoreset  
capacitive loads. To differentiate these conditions from  
short circuits or sustained overloads that may damage  
the device, the MAX1823 has an independent fault-  
blanking circuit in each switch. When a load transient  
causes the device to enter current limit, an internal  
counter starts to monitor the duration of the fault. For  
load faults exceeding 20ms fault-blanking time, the  
switch turns off, the FAULT_ signal asserts low, and the  
device enters autoreset mode (see Autoreset Mode).  
Only current-limit and short-circuit faults are blanked.  
Thermal overload faults and input voltage drops below  
the UVLO threshold immediately cause the switch to  
turn off and FAULT_ to assert low.  
Behavior During Current Limit  
and Fault Blanking  
The MAX1823 limits switch current in three ways. When  
ON_ is deasserted (high for MAX1823, low for  
MAX1823H), the switch is off and leakage dominates  
the residual output current. When ON_ is asserted (low  
for MAX1823, high for MAX1823H), the switch supplies  
a continuous output current of at least 720mA. When  
the output current exceeds the 0.9A threshold, the  
MAX1823 limits the current depending on the output  
voltage. For V  
greater than 1V (current-limit mode),  
OUT_  
the MAX1823 regulates the output current to 0.9A. For  
less than 1V (short-circuit mode), the MAX1823  
V
OUT_  
pulses the switch, decreasing the current to 0.35A  
RMS  
Fault blanking allows the MAX1823 to handle USB  
loads that may not be fully compliant with the USB  
specifications. USB loads with additional bypass  
capacitance and/or large startup currents can be suc-  
cessfully powered even while protecting the upstream  
(Table 1). Note that a thermal overload may result from  
either of these high-current conditions.  
The MAX1823 switches may enter current limit in nor-  
mal operation when powering up or driving heavy  
INA  
FAULTA  
INA  
ONA  
CHARGE  
PUMP  
(ONA)  
ILIM  
BIAS  
OUTA  
1 F  
25mA  
THERMAL  
SHUTDOWN  
UVLO  
REF  
FAULT  
LOGIC  
GND  
4V TO 5.5V  
IN_  
25mA  
ILIM  
TIMER  
20ms  
OSC  
0.1 F  
25kHz  
OUTB  
1 F  
MAX1823  
(ONB)  
CHARGE  
PUMP  
ONB  
INB  
INB  
FAULTB  
Figure 2. Functional Diagram  
_______________________________________________________________________________________  
9
Dual USB Switch with Fault  
Blanking and Autoreset  
Table 1. MAX1823 Current Limiting and Fault Behavior  
CONDITION  
MAX1823 BEHAVIOR  
An output short circuit ramps the current to ISHORT in 2ms to 3ms, the switch shuts off, the  
blanking timer turns on, FAULT_ stays high, and the output current pulses at 0.35ARMS.  
Removing the short circuit before the 15ms short-circuit blanking timeout period allows the  
next ramped current pulse to soft-start the output. The FAULT_ flag stays high.  
A short circuit exceeding 15ms to 20ms forces FAULT_ low at 20ms, enables autoreset  
mode, and sources 25mA at the output.  
Output Short Circuit  
(V  
OUT  
< 1V)  
An output voltage above 0.5V for 20ms resets the switch, turns on the output, and forces  
FAULT_ high.  
An output overload regulates the current at I  
(0.9A), and FAULT_ stays high until the  
LIM  
overload is removed, a thermal fault occurs, or the 20ms continuos current-limit timeout  
period is reached.  
An overcurrent condition still present at 20ms forces FAULT_ low, enables autoreset, and  
sources 25mA at the output.  
An output voltage above 0.5V for 20ms resets the switch, turns on the output, and forces  
FAULT_ high.  
Output Overload Current  
(V > 1V)  
OUT  
A junction temperature of +160oC immediately forces FAULT_ low (the blanking timer does  
not apply to thermal faults) and turns off the switch. The junction cooling 15oC removes the  
thermal fault condition, enables autoreset mode, and sources 25mA at the output. FAULT_  
remains low while a thermal fault condition is present.  
Thermal Fault  
(T > +160oC)  
J
An output voltage above 0.5V for 20ms resets the switch, turns on the output, and forces  
FAULT_ high.  
power source. No fault is indicated if the switch is able  
to bring up the load within the 20ms blanking period.  
at 0.35A (RMS) until the output voltage rises above 1V,  
then the capacitor continues to charge at the full 0.9A  
current limit. There is no limit to the output capacitor  
size, but to prevent a startup fault assertion, the capac-  
itor must charge up within the fault-blanking delay peri-  
od. Typically, starting up into a 330µF or smaller  
capacitor does not trigger a fault output. In addition to  
bulk capacitance, small-value (0.1µF or greater)  
ceramic capacitors improve the outputs resilience to  
electrostatic discharge (ESD).  
Applications Information  
Input Power Source  
IN, INA, and INB provide the power for all control and  
charge-pump circuitry. All three IN_ pins must be con-  
nected together externally. The input voltage slew rate  
should be less than 0.2V/µs to prevent erroneous  
FAULT_ indications. This condition should not occur  
under normal USB applications.  
Driving Inductive Loads  
A wide variety of devices (mice, keyboards, cameras,  
and printers) can load the USB port. These devices  
commonly connect to the port with cables, which can  
add an inductive component to the load. This induc-  
tance causes the output voltage at the USB port to ring  
during a load step. The MAX1823 is capable of driving  
inductive loads, but avoid exceeding the devices  
absolute maximum ratings. Usually the load inductance  
is relatively small, and the MAX1823s input includes a  
substantial bulk capacitance from an upstream regula-  
tor as well as local bypass capacitors, limiting over-  
shoot. If severe ringing occurs due to large load  
inductance, clamp the MAX1823s output below 6V and  
above -0.3V.  
Input Capacitor  
Connect a capacitor from IN_ to ground to limit the  
input voltage drop during momentary output short-cir-  
cuit conditions. A 0.1µF ceramic capacitor is required  
for local decoupling; higher capacitor values will further  
reduce the voltage drop at the input (see Typical  
Operating Circuit). When driving inductive loads, a  
larger capacitance prevents voltage spikes from  
exceeding the MAX1823s absolute maximum ratings.  
Output Capacitor  
Place a 1µF of greater capacitor at each output for  
noise immunity. When starting up into very large  
capacitive loads, the switch pulses the output current  
10 ______________________________________________________________________________________  
Dual USB Switch with Fault  
Blanking and Autoreset  
For a 5V input and 1V output, the maximum power dis-  
sipation per switch is:  
Turn-On and Turn-Off Behavior  
In the absence of faults, the MAX1823s internal switches  
turn on and off slowly under the control of the ON_  
inputs. Transition times for both edges are approximately  
2ms. The slow charge-pump switch drive minimizes load  
transients on the upstream power source. Under thermal  
fault and UVLO, the power device turns off rapidly  
(100ns) to protect the power device.  
P = (1.2A) ( 5V - 1V) = 4.8W  
Since the package power dissipation is only 444mW,  
the MAX1823 die temperature will exceed the thermal  
shutdown threshold, and the switch output shuts down  
until the junction temperature cools 15 C. The duty  
cycle and period are strong functions of the ambient  
temperature and the PC board layout.  
Layout and Thermal Dissipation  
To optimize the switch response time to output short-  
circuit conditions, keep all traces as short as possible  
to reduce the effect of undesirable parasitic induc-  
tance. Place input and output capacitors no more than  
5mm from device leads. All IN_ and OUT_ pins must be  
connected with short traces to the power bus. Wide  
power-bus planes provide superior heat dissipation  
through the switch IN_ and OUT_ pins.  
A short circuit at the output causes the power dissipated  
across the switch and the junction temperature to  
increase. If the fault condition persists, the thermal-  
overload-protection circuitry activates, and the output  
shuts down until the junction temperature decreases by  
+15°C (see Thermal Shutdown).  
Since the output short-circuit current is 25mA (typ), and  
with V  
= 5V, calculate the power dissipation for a  
IN_  
While the switches are on, power dissipation is small,  
short-circuited output as follows:  
and the package temperature change is minimal.  
P = (0.025A)(5) = 0.125W  
Calculate the power dissipation for this condition as fol-  
lows:  
2
P = (I  
) R  
OUT_  
ON  
OUT_  
For the normal operating current (I  
= 0.5A), and  
the maximum on-resistance of the switch (135m ), the  
power dissipation is:  
Chip Information  
TRANSISTOR COUNT: 3227  
PROCESS: BiCMOS  
2
P = (0.5A) x 0.135 = 34mW per switch  
The worst-case power dissipation occurs when the  
switch is in current limit and the output is greater than  
1V. In this case, the power dissipated in each switch is  
the voltage drop across the switch multiplied by the  
current limit:  
P = (I ) (V - V )  
OUT  
LIM  
IN  
______________________________________________________________________________________ 11  
Dual USB Switch with Fault  
Blanking and Autoreset  
Package Information  
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,  
go to www.maxim-ic.com/packages.)  
e
4X S  
10  
10  
INCHES  
MAX  
MILLIMETERS  
MAX  
1.10  
0.15  
0.95  
3.05  
3.00  
3.05  
3.00  
5.05  
0.70  
DIM MIN  
MIN  
-
A
-
0.043  
0.006  
0.037  
0.120  
0.118  
0.120  
0.118  
0.199  
A1  
A2  
D1  
D2  
E1  
E2  
H
0.002  
0.030  
0.116  
0.114  
0.116  
0.114  
0.187  
0.05  
0.75  
2.95  
2.89  
2.95  
2.89  
4.75  
0.40  
H
ÿ 0.50±0.1  
0.6±0.1  
L
0.0157 0.0275  
0.037 REF  
L1  
b
0.940 REF  
0.007  
0.0106  
0.177  
0.270  
0.200  
1
1
e
0.0197 BSC  
0.500 BSC  
0.6±0.1  
c
0.0035 0.0078  
0.0196 REF  
0.090  
BOTTOM VIEW  
0.498 REF  
S
TOP VIEW  
0  
6∞  
0∞  
6∞  
D2  
E2  
GAGE PLANE  
A2  
c
A
E1  
b
L
A1  
D1  
L1  
FRONT VIEW  
SIDE VIEW  
PROPRIETARY INFORMATION  
TITLE:  
PACKAGE OUTLINE, 10L uMAX/uSOP  
APPROVAL  
DOCUMENT CONTROL NO.  
REV.  
1
21-0061  
I
1
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are  
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.  
12 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600  
© 2002 Maxim Integrated Products  
Printed USA  
is a registered trademark of Maxim Integrated Products.  

相关型号:

MAX1823EUB

Dual USB Switch with Fault Blanking and Autoreset
MAXIM

MAX1823EUB+

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, LEAD FREE, MICRO, SOP-10
ROCHESTER

MAX1823EUB+T

Power Supply Support Circuit, Fixed, 1 Channel, BICMOS, PDSO10, LEAD FREE, MICRO, SOP-10
MAXIM

MAX1823EUB-T

Power Supply Support Circuit, Fixed, 1 Channel, BICMOS, PDSO10, MICRO, SOP-10
MAXIM

MAX1823EUBT

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, MICRO MAX PACKAGE-10
MAXIM

MAX1823H

Dual USB Switch with Fault Blanking and Autoreset
MAXIM

MAX1823HEUB

Dual USB Switch with Fault Blanking and Autoreset
MAXIM

MAX1823HEUB

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, MICRO, SOP-10
ROCHESTER

MAX1823HEUB+T

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO10, LEAD FREE, MICRO, SOP-10
ROCHESTER

MAX1823HEUB-T

Power Supply Support Circuit, Fixed, 1 Channel, BICMOS, PDSO10, MICRO, SOP-10
MAXIM

MAX182ABEPI

Converter IC
MAXIM

MAX182ACPI

Calivrated 4-Channel 12-Bit ADC with T/H and Refernce
MAXIM