Power Relay PK2 (THT – THR)  
Features  
– 60% volume reduced  
Power K at increased  
performance  
– PCB area requirements  
minimized by 50% to  
only 293 mm2  
– Size optimized to  
L x W x H (mm)  
18.3 x 16 x 15.9  
– Limiting continuous  
current 40 A  
– Maximum switch on  
current 200 A  
– Increased ambient  
temperature 105°C  
– Design allows highest  
reliability  
– High shock and vibration  
resistance  
– Wave (THT) and reflow  
(THR/pin-in-paste)  
solderable versions  
– For latching (bistable)  
version refer to  
Power Relay PK2 Latching  
Typical Applications  
– ABS control  
– Blower fans  
– Cooling fan  
– Engine control  
– Fuel pump  
201_C-R_3D3  
– Glow plug  
Design  
– ELV/RoHS/WEEE compliant  
– THT: sealed type washable  
– THR: sealed type open vent hole  
Terminals  
PCB terminals for assembly on  
printed circuit boards  
Conditions  
– Hazard warning signal  
– Switched power supply  
All parametric, environmental and  
endurance tests are performed  
according to EIA Standard RS-407-A  
at standard test conditions unless  
otherwise noted:  
Please contact Tyco Electronics for  
relay application support.  
Weight  
Approx. 11 g (0.39 oz.)  
23°C ambient temperature,  
20 - 50% RH, 998.9 33.9 hPa.  
Nominal Voltage  
12 V  
For general storage and processing  
recommendations please refer to our  
Application Notes and especially to  
Storage in the “Glossary” page 23 or  
at http://relays.tycoelectronics.com/  
appnotes/  
Disclaimer  
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the  
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request  
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.  
All rights of Tyco Electronics are reserved.  
134  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 3-2008  
Power Relay PK2 (THT – THR)  
Dimensional Drawing  
*) Additional tin tops max. 1 mm  
201C_DD2  
201C_DD1  
View of the Terminals (bottom view)  
Remark: Positional tolerances according to DIN EN ISO 5458  
**) without tinning (hop dip)  
201C_VT1  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
135  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 3-2008  
Power Relay PK2 (THT – THR)  
Contact Data  
Typical areas of application  
Contact configuration  
Resistive/inductive/capacitive load  
1 Make contact/  
1 Form A  
5 (+)  
4 (-)  
Circuit Symbol  
(see also Pin assignment)  
Rated voltage  
Rated current 1)  
at  
12 V  
33 A  
Limiting continuous current 1)  
23°C  
85°C  
40 A  
33 A  
105°C  
22 A  
Contact material  
Silver based  
See load limit curve  
Max. switching voltage/power  
Max. switching current 2)  
On  
200 A  
40 A  
Off  
Min. recommended load3)  
Voltage drop at 10 A (initial)  
NO contact  
Mechanical endurance (without load)  
Examples of electrical endurance  
at cyclic temperature –40/+23/+85°C  
1 A at 5 V  
Typ. 30 mV, 300 mV max.  
> 2 x 106 operations  
Inductive load: > 1 x 105 operations, 60 A on/35 A 0ff, L = 0.5 mH  
Resistive load: > 1 x 105 operations, 40 A on/40 A 0ff  
Capacitive load: > 1 x 105 operations, 200 A on/20 A 0ff  
6 operations per minute (0.1 Hz)  
and 13.5 V; 120 ms - on/4880 ms - off  
Max. switching rate at nominal load  
1)  
Measured on 70 mm x 70 mm x 1.5 mm epoxy PCB FR4 with 52 cm2 (double layer 140 μm thick) copper area.  
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V load voltages.  
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/  
2)  
3)  
Load Limit Curve  
201C_LLC3  
^
Load limit curve = safe shutdown, no stationary  
arc/make contact  
136  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 3-2008  
Power Relay PK2 (THT – THR)  
Circuit Diagram  
1 Make contact/1 Form A  
5(+)  
4(-)  
1(-)  
2(+)  
201C_PA2  
Coil Data  
Available for nominal voltages  
12 V  
0.8 W  
Nominal power consumption of the unsuppressed coil at nominal voltage (monostable)  
Test voltage winding/contact  
Maximum ambient temperature range 1)  
500 VACrms  
–40 to +105°C  
Typ. 3 ms  
Typ. 1.5 ms  
Operate time at nominal voltage  
Release time at nominal voltage 2)  
1)  
See also operating voltage range diagram.  
For unsuppressed relay coil.  
2)  
Note:  
A low resistive suppression device in parallel to the relay coil increases the release time and reduces  
the lifetime caused by increased erosion and/or higher risk of contact tack welding (monostable version only).  
Operating Voltage Range  
201C_OVR1  
Does not take into account  
the temperature rise due to  
the contact current  
E = pre-energization  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
137  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 3-2008  
Power Relay PK2 (THT – THR)  
Environmental Conditions  
Temperature range, storage  
Test  
Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/  
Relevant standard  
IEC 68-2-1  
Testing as per  
Dimension  
1000 h  
Comments  
–40°C  
Cold storage  
Dry heat  
Thermal shock 1)  
IEC 68-2-2  
IEC 68-2-14  
Ba  
Na  
1000 h  
1000 cycles  
125°C  
–40/+125°C  
Dwell time 15 min  
Vibration resistance  
Shock resistance  
Solderability  
IEC 68-2-6 (sine pulse form)  
IEC 68-2-27 (half sine form single pulses)  
30 - 440 Hz  
> 20 g  
6 ms >30 g  
11 ms > 100 g  
Hot dip 5 s  
215°C  
245°C  
Hot dip 10 s  
260°C  
No change in the  
switching state > 10 μs  
Open contact will not close > 10 μs  
Closed contact will not open > 10 μs  
Aging 3 (4 h/155°C)  
for leaded process (Tm = 183°C)  
for Pb-free process (Tm = 217°C)  
with thermal screen  
THT  
THR  
IEC 68-2-20  
IEC 68-2-58  
Ta, Method 1  
Tb, Method 1A  
Qc, Method 2  
Resistance to soldering heat  
Sealing  
THT  
THR  
IEC 68-2-20  
IEC 68-2-58  
260°C  
Preheating min 130°C  
THT  
THR  
IEC 68-2-17  
1 min/70°C  
Open vent hole  
1)  
Only storage.  
Ordering Information  
Part Numbers  
(see table below for coil data)  
Contact  
Arrangement  
Contact  
Material  
Enclosure  
Soldering  
Technology  
Relay Description  
Part Number  
V23201-C1001-A502  
V23201-R1005-A502  
5-1414782-7  
6-1414932-3  
Form A  
Form A  
Silver based  
Silver based  
Sealed  
THT  
THR  
Open vent hole  
Coil Versions  
1)  
Coil Data  
for  
PK2  
Rated Coil  
Voltage  
(V)  
Coil Resistance  
Must  
Operate Voltage  
(V)  
Must  
Release Voltage  
(V)  
Allowable Overdrive  
Voltage (V)  
at 23°C  
1ꢀ0  
(Ω)  
– THT/THR  
at 1ꢀ5°C  
V23201-***01-****  
V23201-***05-****  
12  
12  
176  
176  
6.9 2)  
6.9 2)  
1.5  
1.5  
27  
17  
17  
27  
1)  
Allowable overdrive is stated with no load applied and minimum coil resistance.  
Standard Delivery Packs (orders in multiples of delivery pack)  
PK2 – THT/THR:  
600 pieces  
138  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  

相关型号:

V23234

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0001-X032

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0001-X038

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0001-X040

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0004-X051

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0004-X053

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A0004-X055

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A1001-X033

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A1001-X036

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A1001-X041

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A1004-X050

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM

V23234-A1004-X054

Power Relay B Plug-in Mini ISO Relays Automotive Relays
MACOM