KUP-14A55-120 [MACOM]
KUP Series Panel Plug-in Relay;型号: | KUP-14A55-120 |
厂家: | Tyco Electronics |
描述: | KUP Series Panel Plug-in Relay |
文件: | 总5页 (文件大小:1228K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay
n
n
n
n
n
n
n
AC coils: 5-240VAC, 50/60 Hz.; DC coils 6-110VDC
Contact arrangements of 1 form X, 1-3 form A and 1-4 form C
Wide selection of termination and mounting styles
PC terminals available
Push-to-test button and indicator lamp options
Sockets available for panel, DIN rail or PCB mounting
Class B coil insulation
Typical applications
Vending, commercial sewing, tool/die equipment, robotics, timers, welding,
HVAC, medical, power generators
Approvals
UL E22575; CSA LR15734
Technical data of approved types on request
AgCdO, 4 pole (continued)
1/3HP, 120VAC
1/2HP, 250VAC
Total load not to exceed 30 A, 28 VDC, 120 VAC and 20 A, 250 VAC
AgSnOInO
Contact Data
Contact arrangement 1 Form X (NO-DM); 1-3 Form A (NO); 1-4 Form C (CO)
10A, 277VAC, pf = 0.8
Mechanical endurance
100x103
Rated voltage
Rated current
Contact material
240VAC
10A
10x106 ops.
Ag
AgCdO
AgSnOInO
Min. recommended contact load 100mA, 12VDC 300mA, 12VDC 300mA, 12VDC
Coil Data
Frequency of operation
Operate/releases time max.
Bounce time max.
360 ops./hr 360 ops./hr 360 ops./hr
Coil voltage range
5 to 110VDC
6 to 240VAC
Class B
15/10ms
17ms
Coil insulation system according UL
Coil versions, DC coil
Contact ratings
Coil
Rated
voltage
VDC
Operate
voltage
VDC
Coil
resistance
Ω 10ꢀ
Rated coil
power
W
Type
Load
Cycles
code
UL 508
Ag, 1, 2 and 3 pole
5A, 240VAC
1, 2 and 3 pole
5
6
5
6
12
24
48
3.75
4.5
9.0
18.0
36.0
82.5
21
32.1
120
472
1800
10000
1.2
1.125
1.2
1.25
1.3
5A, 28VDC
1/6HP, 120VAC
2.5A, 120VAC, tungsten
1/3HP, 240VAC
0.5A, 120VDC
12
24
48
110
4 pole
5
110
1.25
5FLA, 15LRA, 250VAC
Ag, 4 pole
5
6
3.75
4.5
9.0
18.0
36.0
82.5
14
20
80
320
1250
6720
1.8
1.8
1.8
1.8
1.85
1.8
5A, 240VAC
2.5A, 120VAC, tungsten
0.5A, 120VDC
1/6HP, 120VAC
1/3HP, 240VAC
6
12
24
48
110
12
24
48
110
All figures are given for coil without preenergization, at ambient temperature +23°C.
AgCdO, 1, 2 and 3 pole
10A, 240VAC
10A, 32VDC
5FLA, 15LRA, 250VAC
1/3HP, 120VAC
5A, 120VAC, tungsten
1/2HP, 250VAC
Coil versions, AC coil
Coil
code
Rated
voltage
VAC
Operate
voltage
VAC
Coil
resistance
Ω 15ꢀ
Rated coil
power
VA
1 and 2 pole
0.5A, 125VDC
10FLA, 40LRA, 125VAC
3A, 600VAC
1/2HP, 480VAC
1/2HP, 600VAC
6
12
24
120
6
12
24
120
240
5.1
10.2
20.4
102.0
204.0
6
24
85
2250
9110
2.0
2.0
2.0
2.1
2.1
240
1HP, 480 VAC, 3 phase
3 and 4 pole
6
12
24
120
240
AgCdO, 4 pole
6
12
24
120
240
5.1
10.2
20.4
102.0
204.0
4.2
18
72
1700
7200
2.8
2.8
2.8
2.9
2.9
10A, 240VAC
5A, 120VAC, tungsten
0.5A, 120VDC
10A, 28VDC, resistive
10FLA, 30LRA, 125VAC
5FLA, 15LRA, 250 VAC
125VA, 250 VAC
30x103
All figures are given for coil without preenergization, at ambient temperature +23°C.
1
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay (Continued)
Insulation Data
Other Data (continued)
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
1200Vrms
2200Vrms
2200Vrms
Category of environmental protection
IEC 61810
Terminal type
RT0 - open relay; RTI - dust protected
Quick connects (QC), .187, .205 or .250;
PCB-THT
100MΩ, 500VDC
Terminal retention, push force
QC .205
QC .187, QC .250, PCB
Weight
17 lbs for 3s
25 lbs for 3s
Other Data
85g
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
Packaging/unit
tray/25 pcs., box/150pcs.
Accessories
For details see datasheet
DC coil
Enclosed relays, 4 pole: -45ºC to 50ºC
Enclosed relays, 1-3 pole: -45ºC to 70ºC
Open relays: 15ºC higher maximum
Sockets and Accessories, KUP Relays
Product Code Description
AC coil
Enclosed relays, 3 and 4 pole: -45°C to +45°C
Enclosed relays, 1 and 2 pole: -45ºC to +55ºC
Open relays: 15°C higher maximum
27E893
27E121
27E043
27E046
27E067
27E396
DIN socket (use 20C318 clip)
Track mount socket (use 20C314 clips)
Chassis mount/solder eyelet socket (use 20C254 clip)
Chassis mount/PCB socket (use 20C254 clip)
Chassis mount/quick connect socket (use 20C254 clip)
Snap-in/quick connect socket (use 20C254 clip)
Maximum allowable ambient temperature vs voltage (KUP enlcosed)
75°
70°
75°
70°
60°
50°
40°
30°
20°
60°
2.7
50°
40°
V
A
60 Hz
.
COIL
30°
20°
100 110 120 130 140 150 160
% of Nominal Voltage DC
100
110
120
130
140
% Of Nominal 60 Hz. Voltage
Dimensions
Seated Heights For KU (open) Relays
KU bracket type
1.391” (35.33mm) for #6-32 stud
with .218” (5.54mm) locating tab.
2.43 MAX.*
1.437
(36.50)
(61.72)
2.33 MAX.**
(59.18)
2.29 MAX.***
(58.17)
.19
(4.8)
X
X
1.52” (38.6mm) for bracket
with 2-#6 32 tapped holes.
.63
.63
(16.0)
X
(16.0)
1.282” (32.56mm) for #6-32 tapped core
with .125” (3.18mm) or .218” (5.54mm) locating tab.
2.27 MAX.*
(57.7)
2.171 MAX.**
(55.14)
.16
(4.1)
(2) #6-32 THREAD
TAPPED HOLES
2.046” (51.97mm) for relay
with printed circuit terminals.
2.125 MAX.***
(53.98)
KU stud type
STUD TYPE also available with .125” (3.18mm)
tab, as well as without stud and locating tab.
Models without stud have core tapped #6-32
THREAD, .25” (6.4mm) minimum depth.
1.468 MAX.
(37.29)
2.27 MAX.*
(57.7)
2.171 MAX.**
(55.14)
2.125 MAX.***
(53.98)
.
.031 REF.
(.79)
.031 REF
(.79)
1
4
2
5
3
6
1.391
(35.33)
1.282 MAX.
(35.56)
7
8
9
.218
(5.54)
*Dimensions with .250” (6.35mm) terminals.
(42.85) ** Dimensions with .110” (2.79mm) or .205” (5.21mm) terminals.
1.687 MAX.
.109 MAX.
(2.77)
A
B
*** Dimensions with .187” (4.75mm) terminals.
1.39 MAX.*
.31
(7.9)
.065
(1.65)
(35.3)
.437
(11.10)
1.29 MAX.**
(32.8)
1.25 MAX.***
(31.8)
.150
#6-32
THREAD
TAB WIDTH
(3.81)
Relay front diagrams
Models with 6.35mm
(.250) QC terminals
1-3 pole models with
all other terminals
4 pole models
1.531 MAX.
(38.89)
1.531 MAX.
(38.89)
1.531 MAX.
(38.89)
1
4
2
5
3
6
1
4
2
5
3
6
12 3 4
5
9
6
7
8
1.406 MAX.
(35.71)
1.406 MAX.
(35.71)
1.406 MAX.
(35.71)
7
9
7
8
9
10 11 12
A
B
A
B
A
B
2
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay (Continued)
Dimensions (continued)
KUP plain case
KUP core / stud mount case
.288
(7.32)
.187 (4.75) DIA.
PUSH-TO-TEST BUTTON
AVAILABLE
1.968 MAX.†
X
(49.99)
1.906 MAX.‡
(48.41)
1.531 MAX.
(38.89)
1.43 MAX.
(36.27)
.219 MAX.
(5.56)
.130
1.968 MAX.†
(49.99)
1.906 MAX.‡
(48.41)
(3.30)
1
4
2
5
3
6
1.74 MAX.
(44.2)
1.406 MAX.
(35.71)
7
8
9
X
STUD with
A
B
#6-32THREAD
or CORE TAPPED
#6-32
.312
(7.92)
1.39 MAX.*
(35.3)
X
1.29 MAX.**
(32.8)
.437 .010
(11.10 .25)
X
X Is For Terminal Dimensions.
See Teminal Drawings.
X
1.25 MAX.***
(31.8)
KUP top flange case
1.518 MAX.
(38.56)
.078TYP.
(1.98)
1
4
2
5
3
6
1.713 .003
(43.51 .08)
† Dimensions with .250” (6.35mm) terminals.
‡ Dimensions with .187” (4.75mm and .205” 5.21mm) terminals.
7
8
9
1.373 .010
1.989 .003
(50.52)
(34.87 .25)
A
B
*Dimensions with .250” (6.35mm) terminals.
** Dimensions with .110” (2.79mm) or .205”(5.21mm) terminals.
*** Dimensions with .187” (4.75mm) terminals.
2.248 MAX.
(57.10)
.178TYP.
(4.52)
KUP bracket mount case
KUP stud on end case
.312
1.968 MAX. †
2.90 MAX.
(73.7)
.078 R.TYP.
(1.98)
.625TYP.
(15.88)
PUSH-TO-TEST BUTTON
AVAILABLE
TYP.
.38
(9.7)
(49.99)
(7.92)
X
1.906 MAX. ‡
(48.41)
.085 MAX.
(2.16)
.75
(19.1)
1.531 MAX.
(38.89)
.06
(1.52)
X
1.968 MAX.†
(49.99)
X
.375
(9.53)
.437
#6-32 THREAD
.07
2.500
1.906 MAX.‡
(1.8)
(11.10)
.16
(63.50)
(48.41)
(4.1)
Terminal dimensions
4.75mm (.187) quick connect
5.21mm (.205) quick connect
1.19mm (.047) printed circuit
6.35mm (.250) quick connect
.035
(.89)
.125
(3.18)
.156
(3.96)
.093
(2.36)
.093
.156
.125 DIA.
(3.18)
(2.36)
(3.96)
.250 .003
(6.35 .08)
.187 .002
(4.75 .05)
.205± ±±.002
(5.21± ±.05)
.180
(4.57)
HEADER
HEADER
HEADER
HEADER
.106
(2.69)
.250
(6.35)
.078
(1.98)
.035
(.89)
.237
(6.02)
.268 REF.
(6.81)
.156
(3.96)
.285
(7.24)
.316±REF.
(8.03)
THICKNESS
.305
(7.75)
.312
(7.92)
.047
(1.19)
281 REF.
(7.14)
THICKNESS
.358 REF.
(9.09)
.020
(.51)
.032
(0.81)
.032
(.81)
THICKNESS
.032
(.81)
THICKNESS
Terminal assignment
1 Form X
1 Form C
1 Form A (delete 2)
2 Form C
2 Form A (delete 1 & 3)
3 Form C
3 Form A (delete 1, 2 & 3)
4 Form C
1
2
3
4
8
1
4
7
1
4
7
2
3
6
9
2
5
8
3
6
9
6
7
4
6
5
9
5
7
10 11 12
B
A
B
B
B
B
A
A
A
A
3
08-2011, Rev. 0811
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay (Continued)
PCB layout
Bottom view on solder pins
1 form X version
3 pole version
(Omit unnecessry holes for
form A and 2 pole types)
4 pole version
.076 DIA. TYP.
(1.93)
.206
.206
(5.23)
.076 DIA. TYP.
(1.93)
.076 DIA. TYP.
(5.23)
(1.93)
.626
(15.90)
.328
.328
(8.33)
.626
(8.33)
.626
(15.90)
(15.90)
.875
(22.23)
.437
.170
.340
(8.64)
(11.10)
(4.32)
.875
(22.23)
.510
(12.95)
1.020
(25.91)
Product code structure
Type
Typical product code KUP -14
A
1
5
-120
KU
Open style relay
KUP Enclosed relay
Contact arrangement
1
7
1 form A (1 NO)
2 form A (2 NO)
3
1 form X (1 NO-DM)
5
1 form C (1 CO)
11 2 form C (2 CO)
12 3 form A (3 NO)
14 3 form C (3 CO)
Coil Input
17 4 form C (4 CO)
A
AC, 50/60Hz
D
DC
Mounting and options
KU
1
3
4
5
#6-32 mounting stud, 5.54mm (.218in) locating tab
#6-32 tapped core, 3.18mm (.125in) locating tab
#6-32 tapped core, 5.54mm (.218in) locating tab
#6-32 tapped core, no locating tab
KUP
1
2
3
4
5
A
E
T
Socket mount (plain) case
Socket mount (plain) case with push-to-test button 1)
Socket mount (plain) case with indicator lamp 2)
Socket mount (plain) case with indicator lamp and push-to-test button 1) 2)
Bracket mount case
Plain case with #6-32 stud and locating tab
Plain case with #6-32 tapped core and locating tab
Top flange case 1)
1) Not available with four pole models (Contact arrangement 17).
2) Indicator lamps are available on models with the following coils: 6-24VAC and VDC, 110VDC and 120-240VAC.
Only models with 120-240VAC coils are UL recognized.
Terminal and contact material
1 and 2 pole models
1
4.75mm (.187in) quick connect/solder; Ag, 5A
3
1.19mm (.047in) PCB; Ag, 5A
5
J
P
W
4.75mm (.187in) quick connect/solder; AgCdO, 10A
6.35mm (.250in) quick connect/solder; Ag, 5A
4.75mm (.187in) quick connect/solder; AgSnOInO, 10A
6.35mm (.250in) quick connect/solder; AgSnOInO, 10A
7
K
S
1.19mm (.047in) PCB; AgCdO, 10A
6.35mm (.250in) quick connect/solder; AgCdO, 10A
1.19mm (.047in) PCB, AgSnOInO; 10A
3 pole models
1
5
P
4.75mm (.187in) quick connect/solder; Ag, 5A
4.75mm (.187in) quick connect/solder; AgCdO, 10A
4.75mm (.187in) quick connect/solder; AgSnOInO, 10A
3
7
S
1.19mm (.047in) PCB; Ag, 5A
1.19mm (.047in) PCB; AgCdO, 10A
1.19mm (.047in) PCB, AgSnOInO; 10A
4 pole models
1
4
7
4.75mm (.187in) quick connect/solder; Ag, 5A 3)
2.79mm (.110in) quick connect/solder; Ag, 5A
1.19mm (.047in) PCB; AgCdO, 10A
3
5
9
S
1.19mm (.047in) PCB; Ag, 5A
4.75mm (.187in) quick connect/solder; AgCdO, 10A 3)
2.79mm (.110in) quick connect/solder; AgCdO, 10A
1.19mm (.047in) PCB, AgSnOInO; 10A
P
U
4.75mm (.187in) quick connect/solder; AgSnOInO, 10A 3)
2.79mm (.110in) quick connect/solder; AgSnOInO, 10A 2)
3) 4 pole KUP with 4.75mm (.187in) terminals will not plug into sockets. Must use 2.79mm (.110) terminals for socket mounting.
Au flashed contact option
Leave Blank No Au flashing on contacts
Optional Au flashing on contacts
Coil voltage
Coil code: please refer to coil versions table
F
4
08-2011, Rev. 0811
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay (Continued)
Product Code Arrangement
Material
Coil
Terminals
Mounting
Part Number
KUP-5A15-24
1 form C, 1 CO
AgCdO
24VAC
120VAC
240VAC
120VAC
12VDC
24VDC
12VDC
24VDC
120VAC
12VDC
24VAC
120VAC
240VAC
120VAC
24VAC
120VAC
4.75mm (.187in) QC
Socket mount, plain case
6-1393118-0
5-1393119-9
6-1393118-1
6-1393118-3
6-1393118-6
6-1393118-7
7-1393118-0
7-1393118-1
1-1393117-7
1-1393117-8
2-1393117-1
1-1393117-9
2-1393117-2
2-1393117-5
3-1393117-0
2-1393117-9
1-1393117-4
4-1393117-2
4-1393117-8
4-1393117-4
4-1393117-5
4-1393117-6
4-1393117-3
5-1393117-3
6-1393117-0
5-1393117-6
5-1393117-8
5-1393117-9
5-1393117-5
7-1393117-3
7-1393117-7
7-1393117-9
7-1393117-8
8-1393117-0
8-1393117-3
8-1393117-7
8-1393117-9
9-1393117-0
9-1393117-4
1393118-2
KUP-5A15-120
KUP-5A15-240
KUP-5A55-120
KUP-5D15-12
KUP-5D15-24
KUP-5D55-12
Bracket mount case
Socket mount, plain case
Bracket mount case
KUP-5D55-24
KUP-11A11-120
KUP-11A15-12
KUP-11A15-24
KUP-11A15-120
KUP-11A15-240
KUP-11A35-120
KUP-11A55-24
KUP-11A55-120
KUP-11AT5-120
KUP-11D11-24
KUP-11D15-5
2 form C, 2 CO
Ag
AgCdO
Socket mount, plain case
Socket mount case w/ indicator lamp
Bracket mount case
Top flange case
Socket mount, plain case
Ag
AgCdO
24VDC
5VDC
KUP-11D15-12
KUP-11D15-24
KUP-11D15-36
KUP-11D15-110
KUP-11D35-24
KUP-11D55-6
12VDC
24VDC
36VDC
110VDC
24VDC
6VDC
12VDC
24VDC
48VDC
110VDC
120VAC
12VAC
24VAC
120VAC
240VAC
120VAC
Socket mount case w/ indicator lamp
Bracket mount case
KUP-11D55-12
KUP-11D55-24
KUP-11D55-48
KUP-11D55-110
KUP-14A11-120
KUP-14A15-12
KUP-14A15-24
KUP-14A15-120
KUP-14A15-240
KUP-14A25-120
KUP-14A35-120
KUP-14A35-240
KUP-14A35F-120
KUP-14A45-120
KUP-14A55-24
KUP-14A55-120
KUP-14A55-240
KUP-14D11-24
KUP-14D15-6
3 form C, 3 CO
Ag
AgCdO
Socket mount, plain case
Socket mount w/ test button
Socket mount w/ indicator lamp
240VAC
AgCdO w/ Au flash 120VAC
AgCdO
24VAC
Socket mount w/ test button, indicator lamp
Bracket mount case
120VAC
240VAC
24VDC
6VDC
12VDC
24VDC
48VDC
110VDC
24VDC
9-1393117-9
1393118-3
Ag
AgCdO
Socket mount, plain case
1-1393118-0
1-1393118-8
1-1393118-3
1-1393118-4
1-1393118-7
1-1393118-2
2-1393118-3
2-1393118-7
2-1393118-6
2-1393118-9
3-1393118-1
3-1393118-7
3-1393118-8
4-1393118-2
4-1393118-6
5-1393118-0
5-1393118-3
KUP-14D15-12
KUP-14D15-24
KUP-14D15-48
KUP-14D15-110
KUP-14D25-24
KUP-14D35-24
KUP-14D35-110
KUP-14D35F-110
KUP-14D45-110
KUP-14D55-12
KUP-14D55-24
KUP-17A19-120
KUP-17A55-24
KUP-17D19-24
KUP-17D55-24
Socket mount w/ test button
Socket mount w/ indicator lamp
110VDC
AgCdO w/ Au flash
AgCdO
Socket mount w/ test button, indicator lamp
Bracket mount case
12VDC
24VDC
4 form C, 4 CO
120VAC 2.79mm (.110in) QC
Socket mount, plain case
Bracket mount case
Socket mount, plain case
Bracket mount case
24VAC
24VDC
24VDC
5
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
相关型号:
©2020 ICPDF网 联系我们和版权申明