5-1393277-1 [MACOM]

Limiting continuous current 32 A at 85°C;
5-1393277-1
型号: 5-1393277-1
厂家: Tyco Electronics    Tyco Electronics
描述:

Limiting continuous current 32 A at 85°C

文件: 总6页 (文件大小:349K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Features  
– Limiting continuous  
current 32 A at 85°C  
– Wide voltage range  
Typical Applications  
– ABS control  
– Blower fans  
– Car alarm  
– Cooling fan  
– Engine control  
– Fuel pump  
– Hazard warning signal  
– Heated front screen  
– Heated rear screen  
– Ignition  
– Lamps front, rear, fog light  
– Interior lights  
– Main switch/supply relay  
– Seat control  
– Seatbelt pretensioner  
– Sun roof  
– Turn signal  
– Valves  
– Window lifter  
– Wiper control  
Please contact Tyco Electronics  
for relay application support.  
VKP_3d01  
Design  
Terminals  
Conditions  
– ELV compant  
– Open: flux tight type  
aled: washable type  
PCB terminals, for assembly on  
printed circuit boards  
All parametric, environmental and  
endurance tests are performed  
according to EIA Standard RS-407-A  
at standard test conditions unless  
otherwise noted:  
eight  
Approx. 19 g (0.67 oz.)  
open version  
23°C ambient temperature,  
20 - 50% RH, 998.9 33.9 hPa.  
– Approx. 22 g (0.77 oz.)  
sealed version  
For general storage and processing  
recommendations please refer to our  
Application Notes and especially to  
Storage in the “Glossary” page 23 or  
at http://relays.tycoelectronics.com/  
appnotes/  
Nominal Voltage  
12 V or 24 V  
Disclaimer  
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the  
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request  
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.  
All rights of Tyco Electronics are reserved.  
156  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Dimensional Drawing  
VKP Open Version  
Dimensional Drawing  
VKP Sealed Version  
1.04 MAX.  
(26.5)  
.866 MAX.  
(22.0)  
.748 MAX.  
(19.0)  
.911 MAX.  
(23.1)  
.715 MAX.  
(18.2)  
.878 MAX.  
(22.3)  
ECR2131-E  
ECR2130-6  
.150 MAX.  
(3.8)  
.150 MAX.  
(3.81
EXDING  
LDER  
Mounting Hole Layout (bottom view)  
Open version  
Sealed Version  
ø .055  
ø .055  
(1.4)  
2 x .083  
(1.4)  
2x .083  
(2.1)  
(2.1)  
.062  
(1.6)  
3
3
4
5
1 2  
2 x .043  
(1.1)  
2 x .043  
5
1 2  
.086  
(2.2)  
(1.1)  
4
4
4
4
2 x .086  
(2.2)  
2 x .062  
(1.6)  
2 x .062  
(1.6)  
2 x .086  
(2.2)  
.586  
(14.88)  
.211  
.211  
(5.35)  
.134  
(3.4)  
.147  
(3.73)  
.19 MAX.  
(4.8)  
.148  
(5.35)  
.148  
(3.75)  
.289 MAX.  
(7.3)  
(3.75)  
.213  
(5.4)  
3
3
4
2
5
5
1
1
2
.147  
(3.73)  
.467  
(11.87)  
.467  
(11.87)  
.092  
(2.33)  
4
4
4
ECR2132-M  
ECR2133-V  
.161  
(4.08
.161  
(4.08)  
.483  
(12.28)  
.483  
(12.28)  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
157  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Contact Data  
Typical areas of application  
Contact configuration  
Resistive/inductive loads  
High inrush, lamp and capacitive lo
1 Make contact/  
1 Form A  
1 Changeover contact/  
1 Form C  
1 Make contact/  
1 Form A  
1 Changeover conta
1 For
Circuit symbol  
5
5
3
3
(see also Pin assignment)  
4
4
Rated voltage  
Rated current  
12 V  
NC/NO  
NC/NO  
32 A  
25/32 A  
32 A  
25/32 A  
Limiting continuous current  
23°C  
85°C  
105°C  
40 A  
32 A  
25 A  
30/40 A  
25/32 A  
15/25 A  
40 A  
32 A  
2
30/40 A  
25/32 A  
15/25 A  
Contact material  
AgNi0.15 (VKP-***42)  
AgSnO2 (VKP-***52)  
Max. switching voltage/power  
Max. switching current  
On 1)  
See load limit curve  
NC/NO  
NC/NO  
30 A/180 A  
30 A/60 A  
100 A  
60 A  
30 A/100 A  
30 A/60 A  
180 A  
60 A  
2)  
Off  
Min. recommended current  
Voltage drop at 10 A (initial)  
Mechanical endurance (without load)  
Electrical endurance  
1 t 5 V  
Typ. 15 mV  
Typ. 20/15 mV  
Typ. 20 mV  
Typ. 25/20 mV  
107 operations  
105 oprations at 40 A, 14 V,  
(example of resistive load)  
on NO contact  
1)  
Inrush current for lamp load.  
See load limit curve.  
2)  
Load Limit Curve  
128-U  
75  
60  
50  
40  
Safe breaking, arc extinguished (normally  
open contact) for resistive loads.  
30  
20  
12  
10  
7
0.5  
1
2
3
4
10  
20  
30 40  
Swithinnt (A)  
Circuit Diagram  
1 Make contact/1 Form A  
1 Changeover contact/1 Form C  
TE1086-A1  
TE1091-B1  
158  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Contact Data  
Typical areas of application  
Contact configuration  
Flashing lamps  
1 Make contact/  
1 Form A  
1 Changeover contact/  
1 Form C  
Circuit symbol  
5(–)  
3
(see also Pin assignment)  
4(+)  
Rated voltage  
12 V  
Rated current  
30 A  
20/30 A  
Limiting continuous current  
23°C  
85°C  
105°C  
35 A  
30 A  
25 A  
A  
20/30 A  
15/25 A  
Contact material  
AgSnO2 (VKP-***72) 1)  
Max. switching voltage/power  
Max. switching current  
See load limit curve on previous page  
High current version  
High current version  
NC/NO  
On2)  
Off  
240 A  
30 A  
60/240 A  
20/30 A  
NC/NO  
Steady-state flashing3)  
Open  
Sealed  
Alternate flashing4)  
30 A  
25 A  
10/30 A  
10/25 A  
NC/NO  
Open  
8/8 A  
Sealed  
8/8 A  
Min. recommended load5)  
1 A at 5 V  
Voltage drop (initial) at 10 A  
100 mV max. for NO contacts,  
200 mV max. for NC contacts, typ. 40 mV  
Typ. 107 operations  
See application information below  
Mechanical endurance (without load)  
Electrical endurance  
1)  
Center contact pin 4 to be connected to positive potential.  
Inrush current for lamp load.  
Continuous On-Off cycling of a single set of lamps at 60 to 90 oeraions per minute and approx. a 50% duty cycle.  
Continuous cycling between two sets of lamps with one set switched by the NO contacts and the other by the NC contacts, at 60 to 90 operations per minute  
and approx. a 50% duty cycle.  
2)  
3)  
4)  
5)  
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/  
Coil Data  
Available for nominal voltages  
Nominal power consumption of the unsuppressed coil at nominal voltage  
Test voltage winding/contact  
Maximum ambient temperature r
Operate time at nominal voltage  
12 V / 24 V  
1.6 W  
500 VACrms  
–40 to +125°C  
Typ. 5 ms  
Release time at nominvoltage 1)  
Typ. 3 ms  
1) For unsuppressed ry coil.  
Note:  
A low resistive sppression device in parallel to the relay coil increases the release time and reduces  
the lifetime aused by increased erosion and/or higher risk of contact tack welding.  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
159  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Application Information  
Electrical Life Test Information  
Load Polarity: VKP series relays for flashing lamp applications are constructed  
with special AgSnO movable contacts and standard AgSnO stationary contacts.  
This causes the relay to be sensitive to the polarity of the load voltage. This type  
of VKP relay must be mechanized in the circuit such that the more positive con-  
nection is made to the movable contact (identified as terminal 4 in the wiring  
diagrams). Failure to do so will nullify the benefit of the special AgSnO contact  
material and will result in significantly reduced relay life.  
High current relays: 3 bulb T/S system, combined turn signal and ha
warning with special trailering (test requirements):  
3 bulb  
6 bulb  
7 bulb  
14 bulb  
TOTAL  
2.1 million operations  
194 K operations  
259 K operations  
497 K operations  
3.0 million operations  
This application represents about the limit of the performance capability of the  
"Flashing Lamp” type VKP relay. It should be noted ththe low current operations  
have very little effect on the product life where as tbulb (only) loads can be  
expected to fail at less than 1 million operations.  
Typical Applications: Typical applications: VKP series relays for flashing lamp  
applications are typically used for turn signals, hazard warning, emergency vehi-  
cle, and security system applications. They may also be suitable for high in-rush  
current capacitive loads such as audio amplifiers. Use on inductive loads or loads  
with high continuous load currents should be avoided. The relay should also not  
be used in applications, which do not have a significant make current, as high  
contact voltage drop may result.  
Note: Bulb as used here is a 27 Watt turn sbulb, trade #1156. Testing  
includes operations at –40°C, 23°C, and 85°C.  
Design Considerations: It should noted that although the VKP series relays  
are capable of handling relatively gh urrents, when applying the product under  
high current and high ambient temperature conditions, providing adequate con-  
ductor volume is critical, as is the solder connection, particularly with respect to  
the normally open contact termnal. It may be necessary to use high temperature  
solder, a plated throue PCB, or copper lead frame type construction under  
these conditions to pret failure of the solder joint.  
Note: The VKP-***72 series relay with special AgSnO contact material replaces  
the VKP-XXX32 standard current and the VKP-***62 high current PdCu/AgNi0.15  
contact relays.  
High Current Relays: VKP-***72 series relays for flashing lamp applications are  
generally suitable for passenger car, light truck with or without special trailering  
requirements, and medium duty truck, and emergency vehicle applications. They  
are also generally suitable for security system applications for flashing lamps  
and for most audio amplifier applications. This relay is also recommended for  
alternating flasher applications, such as emergency vehicles. This version has  
much improved performance on the normally open contacts, so optimum life can  
be attained for alternating applications by using two normally open relays and  
powering the coils alternately.  
160  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
PCB Relays  
Single Relays  
Catalog 1308028-2  
Revised 6-2009  
VKP (Open – Sealed)  
Environmental Conditions  
Temperature range, storage  
Test  
Vibration resistance  
Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/  
Relevant standard  
Testing as per  
Dimension  
10 - 40 Hz  
40 - 70 Hz  
70 - 100 Hz  
100 - 500 Hz  
11 ms  
Comments  
1.27 mm double amplitude  
Valid for NC c.  
NO cntats are  
significantlhgher  
5 g constant  
0.5 mm double amplitude  
10 g constant  
Shock resistance  
Half sine wave pulse  
No change in the  
20 g  
sng state > 10 μs  
Jump start  
Drop test  
Flammability  
24 V for 5 minutes conducting nominal current at 23°C  
Capable of meeting specifications after 1.0 m (3.28 ft) drop onto concrete ifinal enclosure  
UL94-HB or better, internal parts (meets FMVSS 302)  
Ordering Information  
Part Numbers  
(see table below for coil data)  
Contact  
Arrangement  
Contact  
Material  
Enclosure  
Applications  
Relay Description  
Part Number  
VKP-11F42  
VKP-11H42  
VKP-15F42  
VKP-15H42  
VKP-15F52  
VKP-31F42  
VKP-31H42  
VKP-35F42  
VKP-35H42  
VKP-31F52  
VKP-31H52  
VKP-35F52  
VKP-35H52  
VKP-11F72  
VKP-15F72  
VKP-31F72  
VKP-35F72  
3-1393277-7  
5-1419148-4  
0-1393278-1  
5-1393277-5  
5-1393277-1  
0-1393277-1  
0-1393277-2  
0-1393277-3  
7-1393277-9  
6-1393277-2  
0-1432198-1  
7-1393277-3  
0-1432197-1  
0-1432444-1  
0-1432445-1  
0-1432413-1  
0-1432438-1  
1 Form A  
1 Form A  
1 Form C  
1 Form C  
1 Form C  
1 Form A  
1 Form A  
1 Form C  
1 Form C  
1 Form A  
1 Form A  
1 Form C  
1 Form C  
1 Form A  
1 Form
1 Form A  
1 Form C  
AgNi0.15  
AgNi0.15  
AgNi0.15  
AgNi0.15  
AgSnO2  
AgNi0.15  
AgNi0.15  
AgNi015  
AgN0.15  
gSnO2  
AgSnO2  
AgSnO2  
AgSnO2  
Open  
pen  
en  
Open  
Open  
Sealed  
Sealed  
Sealed  
Sealed  
Sealed  
Sealed  
Sealed  
Sealed  
Open  
General automotive loads  
General automotive loads  
General automotive loads  
General automotive loads  
High inrush loads  
General automotive loads  
General automotive loads  
General automotive loads  
General automotive loads  
High inrush loads  
High inrush loads  
High inrush loads  
High inrush loads  
Flashing lamp loads  
Flashing lamp loads  
Flashing lamp loads  
Flashing lamp loads  
Special AgSnO2  
Special AgSnO2  
Special AgSnO2  
Special AgSnO2  
Open  
Sealed  
Sealed  
Coil Versions  
Coil Data  
for  
VKP  
VKP-**F**2)  
VKP-**H**2)  
Rated Coil  
Voltage  
(V)  
Coil Resistance  
Must  
Operate Voltage  
Must  
Release Voltage  
Allowable Overdrive1)  
Voltage (V)  
at 85°C  
1ꢀ0  
(Ω)  
90  
(V)  
6.8  
13.9  
(V)  
1.2  
2.4  
at 23°C  
19.6  
1
2
14.3  
362  
39.3  
28.6  
1)  
Allowable overdrive is stated with no load applied and minimum coil resistance.  
On request.  
2)  
Standard Deliery Packs (orders in multiples of delivery pack)  
VKP:  
525 pieces  
All specifications subject to change. Consult Tyco Electronics for latest specifications.  
161  

相关型号:

5-1393277-5

Limiting continuous current 32 A at 85°C
MACOM

5-1393302-1

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393302-2

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393302-8

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393303-0

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393304-6

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393304-7

Power Relay F4 Plug-in Mini ISO Relays Automotive Relays
MACOM

5-1393305-3

Power Relay F4 / VF4 Plug-In Relays Mini ISO relays
MACOM

5-1393305-9

Power Relay F4 / VF4 Plug-In Relays Mini ISO relays
MACOM

5-1393486-5

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

5-1393486-6

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE

5-1393486-7

THIS DRAWING IS A CONTROLLED DOCUMENT.
TE