2EDL4 [MACOM]

Dual Configuration Power Entry Module; 双CON组fi guration电源输入模块
2EDL4
型号: 2EDL4
厂家: Tyco Electronics    Tyco Electronics
描述:

Dual Configuration Power Entry Module
双CON组fi guration电源输入模块

文件: 总5页 (文件大小:312K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Dual Configuration Power Entry Module  
L Series  
UL Recognized  
CSA Certified  
VDE Approved  
EDL4C / EHL4C  
EDL1S / EHL1S  
L Series  
Specifications  
• Power entry module with switch or fuse  
Maximum leakage current each Line to Ground:  
DL Models  
.25 mA  
HL Models  
• For 10A capability and high performance filtering  
see the P Series on page 192  
@ 120 VAC 60 Hz:  
@ 250 VAC 50 Hz:  
2 A  
5 A  
.50 mA  
• Two element circuit provides extended EMI  
attenuation similar to EAB inlet filter  
Hipot rating (one minute):  
Line to Ground:  
Line to Line:  
3
2250 VDC  
1450 VDC  
• North American or metric fuse holders  
• Available with minimal leakage current for medical  
applications (HL models)  
Operating Voltage:  
1S & 1SC models (fixed):  
4 & 4C Suffix:  
250 VAC max.  
100, 120, 220 or 240 VAC.  
Ordering Information  
6 E D L 1 S C M  
Operating Frequency:  
Rated Current:  
50/60 Hz  
Fuseholder Type (pre-installed)  
M – Metric  
2 to 6A  
Required Fuse(s):  
North American:  
Metric:  
Omit for North American  
one .25 x 1.25”(not included)  
two 5 x 20mm (not included)  
Mounting Type  
C– Snap-In  
Omit for flange mount  
Switch:  
DPST  
10,000 operations at 51A max. inrush  
Switch Option  
S – DPST on/off switch  
Omit for none  
Voltage Selection Positions  
1 or 4  
L Series  
Filter Type  
D – General Purpose  
H – Medical  
omit for none  
Leakage current designation  
E – Low Leakage (<0.5 mA)  
Current Rating  
2, 4 or 6A  
175  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Dual Configuration Power Entry Module (continued)  
L Series  
North American Fusing  
Metric Fusing  
Available Part Numbers  
Flange Mount  
Snap-In  
Flange Mount  
Snap-In  
Single Voltage,  
Switched  
6EL1S  
6EL4  
6EL1SC  
6EL4C  
6EL1SM  
6EL4M  
6EL1SCM  
6EL4CM  
Non-Filtered  
4 Voltage Select,  
No Switch  
2EDL1S  
4EDL1S  
6EDL1S  
2EDL4  
4EDL4  
6EDL4  
6EHL1S  
6EHL4  
2EDL1SC  
4EDL1SC  
6EDL1SC  
2EDL4C  
4EDL4C  
6EDL4C  
6EHL1SC  
6EHL4C  
2EDL1SM  
4EDL1SM  
6EDL1SM  
2EDL4M  
4EDL4M  
6EDL4M  
6EHL1SM  
6EHL4M  
2EDL1SCM  
4EDL1SCM  
6EDL1SCM  
2EDL4CM  
4EDL4CM  
6EDL4CM  
6EHL1SCM  
6EHL4CM  
Single Voltage,  
Switched  
General  
Purpose Filter  
4 Voltage Select,  
No Switch  
Single Voltage,  
Switched  
Medical Filter  
4 Voltage Select,  
No Switch  
Voltage Selection  
Recommended Panel Cutouts  
.06  
1.52  
R
*
2.201  
(1) 55.91  
(3)  
(3)  
(2) 2.213*  
56.21  
(4) .020  
R
.508  
*
1.122  
*+.008 -.00  
+.203 -.00  
28.50  
1.575  
(3)40.00  
To change selected voltage: disconnect the power  
cord; open cover using a small blade screwdriver or  
similar tool; insert the tool into the voltage selection  
slot and remove wheel from unit; select desired  
voltage; replace wheel into unit and close cover,  
making sure the selected voltage appears in  
connector window.  
  
  
  
  
  
  
  
176  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Dual Configuration Power Entry Module (continued)  
L Series  
Electrical Schematics  
Accessories  
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord  
DL Models  
Single Voltage, Switched (DL1S)  
Customer  
Transformer  
Primaries  
Note 2  
Note 1  
H
On/O!  
Neutral  
Ground  
2
1
(1) (1a)  
(2) (2a)  
Device  
4
3
LA303: Voltage Select Wheel, 3 position  
Hot  
Selection drum for use with L4 models.  
Marked with 110V, 220V and 240V  
G
4 Voltage Select, No-Switch (DL4)  
Customer  
LA304  
: Voltage Select Wheel, 4 position  
Transformer  
120V  
100V  
220V  
240V Primaries  
Selection drum for use with L4 models.  
Marked with 100V, 110V, 220V and 240V.  
One LA304 comes standard with each L4 model.  
3
Note 2  
On/O!  
A
B
C
A
A
B
C
20V  
Note 1  
G
Hot  
B
C
100V  
Ground  
D
E
D
E
D
E
120V  
F
F
F
Neutral  
H
HL Models  
LA400: Blank insert  
Single Voltage, Switched (HL1S)  
Blank to replace switch in single voltage models  
Customer  
Transformer  
Primaries  
Note 2  
Note 1  
H
On/O!  
LA601  
: Insulating Boot  
Neutral  
Ground  
2
1
Plastic shroud to cover back of module to prevent  
inadvertent access  
(1) (1a)  
(2) (2a)  
Device  
4
3
Hot  
G
Replacement Fuse Holders  
4 Voltage Select, No-Switch (HL4)  
Customer  
Transformer  
LA200: North American Fuseholder  
Accommodates one .25 x 1.25” fuse  
120V  
100V  
220V  
240V Primaries  
Note 2  
On/O!  
A
B
C
A
A
B
C
20V  
Note 1  
G
Hot  
B
C
LA201: Metric Fuseholder  
100V  
Accommodates one 5 x 20mm metric fuse  
Ground  
D
E
D
E
D
E
120V  
F
F
F
Neutral  
H
  
  
  
  
177  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Dual Configuration Power Entry Module (continued)  
L Series  
Case Styles  
Flange Models, Non-filtered  
Snap-in Models, Non-filtered  
3
1
4
A
C
E
D
F
B
2
G
H
G
H
C D  
C
D
F
B
A
F
A
.221  
5.61  
.221  
5.61  
E
E
  
  
   
  
  
   
  
  
  
  
  
  
  
  
  
  
Flange Models, Filtered  
Snap-in Models, Filtered  
3
1
4
A
C
E
D
F
B
2
G
H
G
H
C D  
C
D
F
B
A
F
A
.221  
5.61  
E
.221  
5.61  
E
  
   
  
   
  
   
  
   
  
  
  
  
  
  
  
  
  
  
Case Dimensions  
A
  
B
C
  
D
  
E
  
F
  
  
Model No.  
  
    
    
Flange  
Unfiltered  
       
  
  
     
    
       
    
Snap-in  
Unfiltered  
  
    
Flange  
Filtered  
  
  
    
Snap-in  
Filtered  
  
     
178  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  
Catalog: 1654001  
Issue Date: 06.2011  
Corcom Product Guide  
Dual Configuration Power Entry Module (continued)  
L Series  
Performance Data  
Typical Insertion Loss  
Measured in closed 50 Ohm system  
2EDL  
4EDL  
6EDL  
db  
db  
db  
100  
100  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
0
0.1  
1
10  
30  
0.1  
1
10  
30  
0.1  
1
10  
30  
Frequency in MHz  
Frequency in MHz  
Frequency in MHz  
3
6EHL  
db  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
Common Mode / Asymmetrical (L-G)  
Differential Mode / Symmetrical (L-L)  
0
0.1  
1
10  
30  
Frequency in MHz  
Minimum Insertion Loss  
Measured in closed 50 Ohm system  
Differential Mode / Symmetrical (Line to Line)  
Common Mode / Asymmetrical (Line to Ground)  
   
  
    
   
  
    
  
  
  
  
   
  
  
   
   
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
   
  
  
   
  
  
  
  
  
  
  
  
  
179  
Dimensions are in inches and millimeters unless otherwise specified. Values in italics  
are metric equivalents. Dimensions are shown for reference purposes only.  
Specifications subject to change.  
For email, phone or live chat, please go to  
te.com/help  
corcom.com  

相关型号:

2EDL4C

Power Entry Module with RFI Power Line Filter for General or Medical Applications
TE

2EDL4C

Dual Configuration Power Entry Module
MACOM

2EDL4CM

Power Entry Module with RFI Power Line Filter for General or Medical Applications
TE

2EDL4CM

Dual Configuration Power Entry Module
MACOM

2EDL4M

Power Entry Module with RFI Power Line Filter for General or Medical Applications
TE

2EDL4M

Dual Configuration Power Entry Module
MACOM

2EDL8012GXUMA1

Buffer/Inverter Based Peripheral Driver,
INFINEON

2EDL8013GXUMA1

Buffer/Inverter Based Peripheral Driver,
INFINEON

2EDL8014GXUMA1

暂无描述
INFINEON

2EDL8023G3C

2EDL8023G3C is a high-side and low-side driver designed for advanced switching converters such as in telecom and datacom applications. 2EDL8023G3C takes in independent inputs with built-in hysteresis for enhanced noise immunity. 2EDL8023G3C have an integrated 120 V boot-strap diode as well as a precise channel-to-channel propagation delay matching <6 ns that ensures volt-second balance and avoids magnetic core saturation. The driver comes in small 3x3 industry-standard leadless package and pin-out.
INFINEON

2EDL8024G

EiceDRIVER™ 2EDL8024G 双通道结隔离式栅极驱动器 IC 专为半桥应用中的中压功率 MOSFET 设计,如电信和 DC-DC 转换器
INFINEON

2EDL8024G3C

2EDL8024G3C is a high-side and low-side driver designed for advanced switching converters such as in telecom and datacom applications. 2EDL8024G3C takes in independent inputs with built-in hysteresis for enhanced noise immunity. 2EDL8024G3C have an integrated 120 V boot-strap diode as well as a precise channel-to-channel propagation delay matching <6 ns that ensures volt-second balance and avoids magnetic core saturation. The driver comes in small 3x3 industry-standard leadless package and pin-out.
INFINEON