2EDL4 [MACOM]
Dual Configuration Power Entry Module; 双CON组fi guration电源输入模块型号: | 2EDL4 |
厂家: | Tyco Electronics |
描述: | Dual Configuration Power Entry Module |
文件: | 总5页 (文件大小:312K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Dual Configuration Power Entry Module
L Series
UL Recognized
CSA Certified
VDE Approved
EDL4C / EHL4C
EDL1S / EHL1S
L Series
Specifications
• Power entry module with switch or fuse
Maximum leakage current each Line to Ground:
DL Models
.25 mA
HL Models
• For 10A capability and high performance filtering
see the P Series on page 192
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
2 A
5 A
.50 mA
• Two element circuit provides extended EMI
attenuation similar to EAB inlet filter
Hipot rating (one minute):
Line to Ground:
Line to Line:
3
2250 VDC
1450 VDC
• North American or metric fuse holders
• Available with minimal leakage current for medical
applications (HL models)
Operating Voltage:
1S & 1SC models (fixed):
4 & 4C Suffix:
250 VAC max.
100, 120, 220 or 240 VAC.
Ordering Information
6 E D L 1 S C M
Operating Frequency:
Rated Current:
50/60 Hz
Fuseholder Type (pre-installed)
M – Metric
2 to 6A
Required Fuse(s):
North American:
Metric:
Omit for North American
one .25 x 1.25”(not included)
two 5 x 20mm (not included)
Mounting Type
C– Snap-In
Omit for flange mount
Switch:
DPST
10,000 operations at 51A max. inrush
Switch Option
S – DPST on/off switch
Omit for none
Voltage Selection Positions
1 or 4
L Series
Filter Type
D – General Purpose
H – Medical
omit for none
Leakage current designation
E – Low Leakage (<0.5 mA)
Current Rating
2, 4 or 6A
175
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Dual Configuration Power Entry Module (continued)
L Series
North American Fusing
Metric Fusing
Available Part Numbers
Flange Mount
Snap-In
Flange Mount
Snap-In
Single Voltage,
Switched
6EL1S
6EL4
6EL1SC
6EL4C
6EL1SM
6EL4M
6EL1SCM
6EL4CM
Non-Filtered
4 Voltage Select,
No Switch
2EDL1S
4EDL1S
6EDL1S
2EDL4
4EDL4
6EDL4
6EHL1S
6EHL4
2EDL1SC
4EDL1SC
6EDL1SC
2EDL4C
4EDL4C
6EDL4C
6EHL1SC
6EHL4C
2EDL1SM
4EDL1SM
6EDL1SM
2EDL4M
4EDL4M
6EDL4M
6EHL1SM
6EHL4M
2EDL1SCM
4EDL1SCM
6EDL1SCM
2EDL4CM
4EDL4CM
6EDL4CM
6EHL1SCM
6EHL4CM
Single Voltage,
Switched
General
Purpose Filter
4 Voltage Select,
No Switch
Single Voltage,
Switched
Medical Filter
4 Voltage Select,
No Switch
Voltage Selection
Recommended Panel Cutouts
.06
1.52
R
*
2.201
(1) 55.91
(3)
(3)
(2) 2.213*
56.21
(4) .020
R
.508
*
1.122
*+.008 -.00
+.203 -.00
28.50
1.575
(3)40.00
To change selected voltage: disconnect the power
cord; open cover using a small blade screwdriver or
similar tool; insert the tool into the voltage selection
slot and remove wheel from unit; select desired
voltage; replace wheel into unit and close cover,
making sure the selected voltage appears in
connector window.
176
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Dual Configuration Power Entry Module (continued)
L Series
Electrical Schematics
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
DL Models
Single Voltage, Switched (DL1S)
Customer
Transformer
Primaries
Note 2
Note 1
H
On/O!
Neutral
Ground
2
1
(1) (1a)
(2) (2a)
Device
4
3
LA303: Voltage Select Wheel, 3 position
Hot
Selection drum for use with L4 models.
Marked with 110V, 220V and 240V
G
4 Voltage Select, No-Switch (DL4)
Customer
LA304
: Voltage Select Wheel, 4 position
Transformer
120V
100V
220V
240V Primaries
Selection drum for use with L4 models.
Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.
3
Note 2
On/O!
A
B
C
A
A
B
C
20V
Note 1
G
Hot
B
C
100V
Ground
D
E
D
E
D
E
120V
F
F
F
Neutral
H
HL Models
LA400: Blank insert
Single Voltage, Switched (HL1S)
Blank to replace switch in single voltage models
Customer
Transformer
Primaries
Note 2
Note 1
H
On/O!
LA601
: Insulating Boot
Neutral
Ground
2
1
Plastic shroud to cover back of module to prevent
inadvertent access
(1) (1a)
(2) (2a)
Device
4
3
Hot
G
Replacement Fuse Holders
4 Voltage Select, No-Switch (HL4)
Customer
Transformer
LA200: North American Fuseholder
Accommodates one .25 x 1.25” fuse
120V
100V
220V
240V Primaries
Note 2
On/O!
A
B
C
A
A
B
C
20V
Note 1
G
Hot
B
C
LA201: Metric Fuseholder
100V
Accommodates one 5 x 20mm metric fuse
Ground
D
E
D
E
D
E
120V
F
F
F
Neutral
H
177
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Dual Configuration Power Entry Module (continued)
L Series
Case Styles
Flange Models, Non-filtered
Snap-in Models, Non-filtered
3
1
4
A
C
E
D
F
B
2
G
H
G
H
C D
C
D
F
B
A
F
A
.221
5.61
.221
5.61
E
E
Flange Models, Filtered
Snap-in Models, Filtered
3
1
4
A
C
E
D
F
B
2
G
H
G
H
C D
C
D
F
B
A
F
A
.221
5.61
E
.221
5.61
E
Case Dimensions
A
B
C
D
E
F
Model No.
Flange
Unfiltered
Snap-in
Unfiltered
Flange
Filtered
Snap-in
Filtered
178
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Dual Configuration Power Entry Module (continued)
L Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
2EDL
4EDL
6EDL
db
db
db
100
100
100
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
0
0
0
0.1
1
10
30
0.1
1
10
30
0.1
1
10
30
Frequency in MHz
Frequency in MHz
Frequency in MHz
3
6EHL
db
100
90
80
70
60
50
40
30
20
10
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
0
0.1
1
10
30
Frequency in MHz
Minimum Insertion Loss
Measured in closed 50 Ohm system
Differential Mode / Symmetrical (Line to Line)
Common Mode / Asymmetrical (Line to Ground)
179
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
相关型号:
2EDL8023G3C
2EDL8023G3C is a high-side and low-side driver designed for advanced switching converters such as in telecom and datacom applications. 2EDL8023G3C takes in independent inputs with built-in hysteresis for enhanced noise immunity. 2EDL8023G3C have an integrated 120 V boot-strap diode as well as a precise channel-to-channel propagation delay matching <6 ns that ensures volt-second balance and avoids magnetic core saturation. The driver comes in small 3x3 industry-standard leadless package and pin-out.
INFINEON
2EDL8024G3C
2EDL8024G3C is a high-side and low-side driver designed for advanced switching converters such as in telecom and datacom applications. 2EDL8024G3C takes in independent inputs with built-in hysteresis for enhanced noise immunity. 2EDL8024G3C have an integrated 120 V boot-strap diode as well as a precise channel-to-channel propagation delay matching <6 ns that ensures volt-second balance and avoids magnetic core saturation. The driver comes in small 3x3 industry-standard leadless package and pin-out.
INFINEON
©2020 ICPDF网 联系我们和版权申明