1393776-3 概述
P1 Relay V23026 P1继电器V23026
1393776-3 数据手册
通过下载1393776-3数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Signal Relays
AXICOM
P1 Relay V23026
n
n
n
n
n
n
Directly triggerable with TTL standard modules as ALS, HCT & ACT
Slim line 13.5x7.85mm (0.531x0.309”)
Switching current 1 A
Bifurcated 1 form C (CO) contact
Immersion cleanable
High sensitivity results in low nominal power consumption, 65 to
130mW for monostable and 30 to 150mW for bistable (latching)
n
Initial surge withstand voltage
2.5kV (2/10μs) meets the Bellcore Requirement GR-1089
1.5kV (10/160μs) meets FCC Part 68
P1_THTSMD
Typical applications
Automotive equipment, CAN bus, imobilizer, office equipment, measurement
and control equipment, medical equipment, safety equipment
Z
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
Coil Data
Magnetic system
Coil voltage range
polarized
3 to 24VDC
other coil voltages on request
see coil operative range
85°C
Operative range, IEC 61810
Max. coil temperature
Thermal resistance
Contact Data
Contact arrangement
Max. switching voltage
Rated current
1 form C (CO)
125VDC, 150VAC
<130K/W
1A
Coil versions, THT, monostable
Limiting continuous current, 85°C
Breaking capacity max.
Contact material
1A
see max. DC load breaking capacity
Palladium nickel,
gold-rhodium covered
bifurcated contact
10mA at 20mV
≤50mΩ at 10mA/20mV
200 ops./s
Coil
code
Rated
voltage
VDC
3
5
9
12
24
Operate
voltage
VDCmin.
2.25
3.75
6.75
Release
voltage
VDCmin.
0.3
0.5
0.9
Coil
resistance
Rated coil
power
mW
66
Ω
10ꢀ
137
370
1165
2250
4500
006
001
005
002
004
Contact style
68
70
34
128
Min. recommended contact load
Initial contact resistance
Frequency of operation without load
Operate/release time max.
Set/reset time max.
Bounce time max.
9.00
18.00
1.2
2.4
All figures are given for coil without pre-energization, at ambient temperature +23°C.
2ms
2ms
3ms
Coil versions, SMT, monostable
Electrical endurance
at 12V/10mA
at 6V/100mA
at 30V/1000mA
Contact ratings
UL contact ratings
Coil
code
Rated
voltage
VDC
3
5
9
12
24
Operate
voltage
VDCmin.
2.25
3.75
6.75
Release
voltage
VDCmin.
0.3
0.5
0.9
Coil
resistance
Rated coil
power
mW
80
typ. 50x106 operations
typ. 10x106 operations
typ. 10x103 operations
Ω
10ꢀ
113
313
1015
1800
4500
026
021
025
022
024
80
80
80
128
30VDC/1A
65VDC/0.46A
9.00
18.00
1.2
2.4
150VAC/0.46A
Mechanical endurance
typ. 109 operations
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Max. DC load breaking capacity
Coil operative range, monostable DC coil
65 mW
130 mW
Umax. at 0 A
Umax. at 0 A
Umax. at - 1 A
Unom. nominal coil voltage
Uop. min.
Urel. min.
Ambient Temperature [°C]
1
02-2012, Rev. 0212
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Signal Relays
AXICOM
P1 Relay V23026 (Continued)
Coil data (continued)
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Initial surge withstand voltage
between contact and coil
Capacitance
Coil versions, THT and SMT, bistable 2 coils
500Vrms
1500Vrms
Coil
code
Rated
voltage
VDC
3
5
9
Set
voltage
VDC
2.25
3.75
6.75
Reset
voltage
VDC
2.25
3.75
6.75
9.00
Coil
resistance
10ꢀ
130
390
1200
1500
Rated coil
power
mW
69
Ω
2500V
106
101
105
102
64
68
96
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
between adjacent contacts
max. 5pF
max. 6pF
12
9.00
241)
0.75mm
0.75mm
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coils I and II are identical.
1) A nominal voltage of 24VDC is feasible with a 12VDC coil with a series resistor (1500Ω)
RF Data
Isolation at 100MHz/900MHz
Insertion loss at 100MHz/900MHz
Voltage standing wave ratio (VSWR)
at 100MHz/900MHz
-30.0dB/-18.0dB
-0.12dB/-1.9dB
Coil data (continued)
Coil versions, THT, bistable 1 coil
1.06/1.75
Coil
code
Rated
voltage
VDC
3
Set
voltage
VDC
Reset
voltage
VDC
-2.25
-3.75
-6.75
-9.00
-18.00
Coil
resistance
Rated coil
power
mW
30
Ω
10ꢀ
300
740
2160
4500
4500
Other Data
056
051
057
052
054
2.25
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
5
9
3.75
6.75
34
38
32
128
www.te.com/customersupport/rohssupportcenter
12
24
9.00
18.00
Ambient temperature
-40 to +85°C
Category of environmental protection,
IEC 61810
Vibration resistance (functional)
RT III - immersion cleanable
20g, 200 to 2000Hz
40g, 10 to 200Hz
Coil data (continued)
Coil versions, SMT, bistable 1 coil
Shock resistance (functional)
IEC 60068-2-27 (half sine)
Terminal type
50 g
PCB terminals and SMT terminals
max. 2g
Coil
code
Rated
voltage
VDC
5
Set
voltage
VDC
Reset
voltage
VDC
-3.75
-9.00
Coil
resistance
10ꢀ
740
4500
Rated coil
power
mW
Weight
Resistance to soldering heat THT
IEC 60068-2-20
Resistance to soldering heat SMT
IEC 60068-2-58
Ω
265 °C/10s
051
052
3.75
34
32
12
9.00
see reflow profile
A nominal voltage of 24V is feasible with a 12V coil with a series resitor (4500Ω)
Other coil voltages on request
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coils I and II are identical.
Moisture sensitive level, JEDEC J-Std-020D
Washing
Ultrasonic cleaning
Packaging unit
THT
MSL3
not recommended
possible
2000 pcs.
2400 pcs.
SMT
Coil operative range, bistable
Umax upper limit of the operative range of the coil voltage (limiting voltage) when coils are
65 mW Latching
32 mW Latching
Umax. - 5 % coil duty at 1 A
Umax. - 100 % coil duty at 0 A
Umax. - 5 % coil duty at 0 A
Unom. nominal coil voltage
Uset min.
Ambient Temperature [°C]
continuously energized.
Uop min lower limit of the operative range of the coil voltage (reliable operate voltage).
Urel min lower limit of the operative range of the coil voltage (reliable release voltage).
2
02-2012, Rev. 0212
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
AXICOM
Dimensions
THT version
SMT version
13.4 0.1
13.0 0.1
7.60 0.1
7.75 0.1
5.08 0.15
10.9-0.5
5.08 0.15
PCB layout
TOP view on component side of PCB
THT version
SMT version
Terminal assignment
Monostable version
rest condition
Bistable version, 1 coil
reset condition
Bistable version, 2 coils
reset condition
Contacts are shown in reset
condition. Both coils can be used
either as set or reset coil.
Contact position might change
during transportation and must be
reset before use.
3
02-2012, Rev. 0212
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Signal Relays
AXICOM
P1 Relay V23026 (Continued)
Processing
Packing
Recommended soldering conditions
Soldering conditions according IEC 60058-2-58 and
IPC/JEDEC J-STD-020B
Tube for THT version
40 relays per tube, 2000 relays per box
Full line:
typical
20 - 40 sec
Dotted line: process limits
240 °C
180 °C
130 °C
100 °C
forced
cooling
Tape and reel for SMT version
480 relays per reel, 2400 relays per box
Vapor Phase Soldering:
temperature/time profile (lead
and housing peak temperature)
Resistance to soldering heat - Reflow profile
Time (s)
11.6±0.2
Infrared Soldering: temperature/
time profile (lead and housing
peak temperature)
Recommended reflow soldering profile
Reel dimensions
Time (s)
4
02-2012, Rev. 0212
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Signal Relays
AXICOM
P1 Relay V23026 (Continued)
Product code structure
Type
Typical product code V23026
A1
002
B201
V23026 P1 Series Signal Relay
Version
A1 THT, monostable
D1 SMT, monostable
E1 SMT, bistable (latching), 2 coils
F1 SMT, bistable (latching), 1 coil
B1 THT, bistable (latching), 2 coils
C1 THT, bistable (latching), 1 coil
Coil
Coil code: please refer to coil versions table
Contacts
B201 1 form C, 1 CO
Product Code
V23026A1006B201
V23026A1001B201
V23026A1005B201
V23026A1002B201
V23026A1004B201
V23026B1106B201
V23026B1101B201
V23026B1105B201
V23026B1102B201
V23026C1056B201
V23026C1051B201
V23026C1057B201
V23026C1052B201
V23026C1054B201
V23026D1026B201
V23026D1021B201
V23026D1025B201
V23026D1022B201
V23026D1024B201
V23026E1106B201
V23026E1101B201
V23026E1105B201
V23026E1102B201
V23026F1051B201
V23026F1052B201
Version
Coil
Coil voltage
3VDC
Part Number
1-1393774-7
1393774-1
1-1393774-5
1393774-8
1-1393774-2
1393775-3
3-1393774-4
1393775-2
3-1393774-5
2-1393774-6
2-1393774-0
2-1393774-7
2-1393774-1
2-1393774-4
1393776-8
1393776-3
1422015-9
1393776-4
1393776-7
1393777-3
1422015-6
1393777-2
1393776-9
1422015-8
4-1393774-3
THT version
monostable
5VDC
9VDC
12VDC
24VDC
3VDC
bistable, 2 coils
5VDC
9VDC
12VDC
3VDC
5VDC
9VDC
12VDC
24VDC
3VDC
5VDC
9VDC
12VDC
24VDC
3VDC
5VDC
9VDC
12VDC
9VDC
12VDC
SMT version
monostable
bistable, 2 coils
5
02-2012, Rev. 0212
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
1393776-3 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
1393776-4 | MACOM | P1 Relay V23026 | 获取价格 | |
1393776-7 | MACOM | P1 Relay V23026 | 获取价格 | |
1393776-8 | MACOM | P1 Relay V23026 | 获取价格 | |
1393776-9 | MACOM | P1 Relay V23026 | 获取价格 | |
1393777-2 | MACOM | P1 Relay V23026 | 获取价格 | |
1393777-3 | MACOM | P1 Relay V23026 | 获取价格 | |
1393779-1 | TE | Small size permitting high packing density | 获取价格 | |
1393779-2 | TE | Small size permitting high packing density | 获取价格 | |
1393779-3 | TE | Small size permitting high packing density | 获取价格 | |
1393779-4 | TE | Small size permitting high packing density | 获取价格 |
1393776-3 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6