10EH3 概述
Power Inlet Line Filter for Medical Equipment 医疗设备电源输入线路滤波器 电源连接器
10EH3 规格参数
是否Rohs认证: | 符合 | 生命周期: | Active |
Reach Compliance Code: | compliant | 风险等级: | 2.3 |
Is Samacsys: | N | 其他特性: | STANDARDS: CSA, UL, VDE |
连接器类型: | MAINS POWER CONNECTOR | 联系完成配合: | NOT SPECIFIED |
触点性别: | MALE | 触点材料: | NOT SPECIFIED |
耦合类型: | SNAP | 电源连接器额定值: | 10A, 120/250VAC |
安装类型: | PANEL | 触点总数: | 3 |
Base Number Matches: | 1 |
10EH3 数据手册
通过下载10EH3数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment
H Series
UL Recognized
CSA Certified
VDE Approved*
EH8
EH9
EH4
EH1
EH5
H Series
Specifications
• Minimal leakage current suitable for medical
equipment
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
2 A
5 A
@250 VAC 50 Hz:
• Two element circuit provides basic EMI
attenuation above 1 MHz
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
• Available with an internal ground circuit inductor
(C suffix versions) to isolate equipment chassis
from power line ground at radio frequencies
3
Rated Voltage (max.):
250 VAC
50/60 Hz
3 to 15A*
• Flanged mounting the same as the EC, ED and EF
Series
Operating Frequency:
Rated Current:
• Capacitive output (see EAH, EBH and EJH Series
for capacitive input)
Operating Ambient Temperature Range
(at rated current I ):
-10°C to +40°C
In an ambient temperature (T ) higher than +40°C
r
Ordering Information
3 E H 1 C
a
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o
r
Ground Circuit Inductor
Omit if none
Electrical Schematic
LINE
LOAD
Output Styles
1
Chassis Mount Style
1 – .250 [6.3] spade terminals
3 – Wire leads
Power Inlet Style *
4 – .250 [6.3] spade terminals
Available Part Numbers
(back)
5 – Wire leads (bottom)
3EH1
3EH3
6EH1
6EH3
6EH4
6EH5
6EH8
8 – Wire leads (back)
9 – .250 [6.3] spade terminals
(bottom)
6EH9
10EH1
10EH3
10EH4
15EH4
H Series
Ground Circuit Inductor Versions
10EH4C
Leakage current designation
E – Low Leakage (<0.5 mA)
Current Rating
3, 6, 10 or 15A
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
*IEC 60320-1 C14 inlet mates with C13 connector
169
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment (continued)
H Series
Case Styles
H5
H1 (Chassis Mount)
C
D
D
E B
E
A
B
F
C
A
F
H3 (Chassis Mount)
H8
F
Blue
Green/Yellow
E
D
B
D
E
B
Brown
F
A
A
C
C
H4 & H4C
C
D
E
A
B
Recommended Panel Cutouts
Front Mount
Back Mount
.820
.900
22.9
20.8
H9
.140
3.56
.140
3.56
1.200
30.48
1.200
30.48
1.575
40.01
1.575
40.01
C
.062
1.58
.234
5.94
R.
Typ.
R.
Typ.
.65
16.5
Tolerances
.005 [0.13] unless otherwise noted
Max.
D
E
A
B
170
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment (continued)
H Series
Case Dimensions
Performance Data
A
B
C
D
E
F
Typical Insertion Loss
Measured in closed 50 Ohm system
Part No.
3EH
6EH
H1
db
db
100
100
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
H3
6EH4
10EH4,
10EH4C
0
0
0.01
0.1
1
10
30
0.1
1
10
30
Frequency in MHz
Frequency in MHz
15EH4
H5
10EH
15EH
db
db
100
100
3
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
H8
H9
0
0
0.1
1
10
30
0.01
0.1
1
10
30
Frequency in MHz
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
FA601
: Insulating Shroud
.413
10.5
.271
6.9
Dia.
Dia.
.118
3.0
1.39
35.4
1.17
29.7
.767
19.5
171
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
10EH3 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
10EH4 | TE | Power Inlet Line Filter for Medical Equipment | 获取价格 | |
10EH4C | TE | Power Inlet Line Filter for Medical Equipment | 获取价格 | |
10EHA20 | NIEC | SCHOTTKY BARRIER DIODE | 获取价格 | |
10EHA20 | KYOCERA AVX | Schottky barrier diodes are not PN junctions, but diodes that utilize potential barriers between s | 获取价格 | |
10EHA20_15 | NI | SBD | 获取价格 | |
10EHA20_2015 | NI | SBD | 获取价格 | |
10EHG1-2 | TE | Smallest Power Entry Module with Metric Fuse Holders | 获取价格 | |
10EHG8-2 | TE | Smallest Power Entry Module with Metric Fuse Holders | 获取价格 | |
10EHGS1-2 | TE | Smallest Power Entry Module with Metric Fuse Holders | 获取价格 | |
10EHT1 | TE | High Performance RFI Power Line Filters for Medical Equipment | 获取价格 |
10EH3 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6