LLNRK110 [LITTELFUSE]

Electric Fuse, Time Delay Blow, 110A, 250VAC, 125VDC, 200000A (IR), Inline/holder,;
LLNRK110
型号: LLNRK110
厂家: LITTELFUSE    LITTELFUSE
描述:

Electric Fuse, Time Delay Blow, 110A, 250VAC, 125VDC, 200000A (IR), Inline/holder,

电路保护
文件: 总3页 (文件大小:188K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LLNRK/LLSRK Series POWR-PRO® Class RK1  
250/600 VAC Dual-Element, Time-Delay 1/10 600 Amperes  
SPECIFICATIONS  
Voltage Ratings: AC: 250 Volts (LLNRK)  
600 Volts (LLSRK)  
DC: 125 Volts (LLNRK)  
300 Volts (LLSRK)  
Interrupting Ratings:  
AC: 200,000 amperes rms symmetrical  
300,000 amperes rms symmetrical  
(Littelfuse self-certified)  
DC: 20,000 amperes  
Ampere Range: 1/10 600 amperes  
Approvals:  
AC: Standard 248-12, Class RK1  
UL Listed (File No: E81895)  
CSA Certified (File No: LR29862)  
QPL: Federal Specification No.WF-1814  
DC: Littelfuse self-certified  
AMPERE RATINGS  
1
10  
1
2810  
3
61⁄  
7
8
9
4
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
300  
350  
400  
450  
500  
600  
15  
11⁄  
8
100  
110  
125  
150  
175  
200  
225  
250  
100  
2
11⁄  
4
3210  
10  
1
*
4  
10  
10  
2  
1410  
1610  
1810  
2
31⁄  
2
3
4
1
6
4
10  
12  
15  
41⁄  
5
2
10  
10  
21⁄  
21⁄  
4
5610  
6
171⁄  
2
8
2
20  
* LLSRK Only.  
Example part number (series & amperage): LLNRK 450  
RECOMMENDED FUSE BLOCKS  
LR250 series (LLNRK Series)  
LR600 series (LLSRK Series)  
Refer to Fuse Block section of this catalog for additional  
information.  
FEATURES/BENEFITS  
Littelfuse LLNRK and LLSRK series POWR-PRO® fuses  
provide superior overload and short circuit protection for  
service entrance, main, feeder and general-purpose branch  
circuits up to 600 amperes.  
Extremely current limiting Reduces damage to circuits  
and equipment under short-circuit conditions. Stops  
damaging short circuits faster than any mechanical  
protective device.  
LLNRK/LLSRK series fuses can be installed in existing Class  
H fuse blocks to upgrade systems containing lower interrupt-  
ing rating Class H one-time or renewable fuses.  
300kA Interrupting Rating Littelfuse self-certified to  
300,000 amperes as standard. Meets future trend towards  
higher available short circuit currents.  
APPLICATIONS  
Reduced costs Current limiting design often permits  
All general-purpose circuits  
Motors  
use of readily available, less costly equipment. Low  
resistance design reduces power consumption and utility  
bills.  
Transformers  
Excellent time delay True dual-element construction,  
Solenoids  
with separate non-fatiguing thermally-reversible spring-  
loaded thermal overload element, withstands repeated  
surges within rated time delay without opening needlessly.  
Eliminates needless downtime caused by power surges or  
equipment demands.  
Fluorescent lighting  
All system components with high in-rush currents  
12  
LLNRK/LLSRK Series POWR-PRO® Class RK1  
250/600 VAC Dual-Element, Time-Delay 1/10 600 Amperes  
A
A
E
F
K
C
G
B
D
F
D
G
B
H
E
J
C
70-600A  
FIG. 1  
FIG. 2  
DIMENSIONS IN INCHES (mm in parentheses)  
REFER TO  
FIG. NO.  
AMPERES  
SERIES  
A
B
C
D
E
F
G
H
J
K
2
1/2  
(12.7)  
1/2  
(12.7)  
9/16  
(14.3)  
5/64  
(2.0)  
5/32  
(4.0)  
3/8  
(9.5)  
LLNRK  
LLSRK  
LLNRK  
LLSRK  
LLNRK  
LLSRK  
LLNRK  
LLSRK  
LLNRK  
LLSRK  
LLNRK  
LLSRK  
(50.8)  
1/10 30  
35 60  
1
5
3/4  
(19.1)  
5/8  
(15.9)  
13/16  
(20.6)  
3/32  
(2.4)  
3/16  
(4.8)  
5/8  
(15.9)  
(127.0)  
3
3/4  
(19.1)  
5/8  
(15.9)  
13/16  
(20.6)  
3/32  
(2.4)  
3/16  
(4.8)  
5/8  
(15.9)  
(76.2)  
1
2
2
2
2
5-1/2  
(139.7)  
1
5/8  
(15.9)  
1-1/16  
(27.0)  
3/32  
(2.4)  
1/4  
(6.4)  
7/8  
(22.2)  
(25.4)  
5-7/8  
(149.2)  
1
1-1/16  
(27.0)  
1-1/16  
(27.0)  
1/8  
(3.2)  
3/4  
(19.1)  
1-1/4  
(31.8)  
1/4  
(6.4)  
9/32  
(7.1)  
1/2  
(12.7)  
(25.4)  
70 100  
110 200  
225 400  
450 600  
7-7/8  
(200.0)  
1-1/4  
(31.8)  
1-1/16  
(27.0)  
1-5/16  
(33.3)  
1/8  
(3.2)  
3/4  
(19.1)  
1-1/2  
(38.1)  
1/4  
(6.4)  
9/32  
(7.1)  
1/2  
(12.7)  
7-1/8  
(181.0)  
1-1/2  
(38.1)  
1-15/32  
(37.3)  
1-19/32  
(40.5)  
3/16  
(4.8)  
1-1/8  
(28.6)  
1-27/32  
(46.8)  
7/16  
(11.1)  
9/32  
(7.1)  
11/16  
(17.5)  
9-5/8  
(244.5)  
1-3/4  
(44.5)  
1-15/32  
(37.3)  
1-27/32  
(46.8)  
3/16  
(4.8)  
1-1/8  
(28.6)  
2-3/32  
(53.2)  
7/16  
(11.1)  
9/32  
(7.1)  
11/16  
(17.5)  
8-5/8  
(219.1)  
2
1-15/16  
(49.2)  
2-3/32  
(53.2)  
1/4  
(6.4)  
1-5/8  
(41.3)  
2-11/32  
(59.5)  
5/8  
(15.9)  
13/32  
(10.3)  
15/16  
(23.8)  
(50.8)  
11-5/8  
(295.3)  
2-1/2  
(63.5)  
2
2-19/32  
(65.9)  
1/4  
(6.4)  
1-5/8  
(41.3)  
2-27/32  
(72.2)  
5/8  
(15.9)  
13/32  
(10.3)  
15/16  
(23.8)  
(50.8)  
10-3/8  
(263.5)  
2-1/2  
(63.5)  
2-3/8  
(60.3)  
2-19/32  
(65.9)  
1/4  
(6.4)  
2
2-27/32  
(72.2)  
3/4  
(19.1)  
17/32  
(13.5)  
1-1/8  
(28.6)  
(50.8)  
13-3/8  
(339.7)  
3
2-13/32  
(61.1)  
3-3/32  
(78.6)  
1/4  
(6.4)  
2
3-11/32  
(84.93)  
3/4  
(19.1)  
17/32  
(13.5)  
1-1/8  
(28.6)  
(76.2)  
(50.8)  
LLSRK  
LLNRK  
1000  
800  
600  
1000  
800  
600  
400  
300  
400  
300  
200  
200  
100  
80  
60  
100  
80  
60  
40  
30  
40  
30  
20  
20  
10  
8
6
10  
8
6
4
3
4
3
2
2
1
1
.8  
.8  
.6  
.6  
.4  
.3  
.4  
.3  
.2  
.2  
.1  
.1  
.08  
.08  
.06  
.06  
.04  
.03  
.04  
.03  
.02  
.02  
.01  
.01  
CURRENT IN AMPERES  
CURRENT IN AMPERES  
13  
LLNRK/LLSRK Series POWR-PRO® Class RK1  
250/600 VAC Dual-Element, Time-Delay 1/10 600 Amperes  
Current-Limiting Effects  
Current-Limiting Effects  
of LLNRK (250V) fuses  
of LLSRK (600V) fuses  
* Prospective RMS Symmetrical Amperes Short-Circuit Current  
** Apparent RMS Symmetrical  
* Prospective RMS Symmetrical Amperes Short-Circuit Current  
** Apparent RMS Symmetrical  
Note: Data derived from Peak Let-Thru Curves  
Note: Data derived from Peak Let-Thru Curves  
Short  
Circuit  
Current*  
Short  
Circuit  
Current*  
Peak Let-Thru Current**  
for various fuse ratings  
60A 100A 200A 400A 600A  
Peak Let-Thru Current**  
for various fuse ratings  
60A 100A 200A 400A 600A  
30A  
30A  
5,000  
10,000  
15,000  
20,000  
25,000  
30,000  
35,000  
40,000  
50,000  
60,000  
80,000  
900  
1,400 2,000 2,700 4,800 5,000  
5,000  
10,000  
15,000  
20,000  
25,000  
30,000  
35,000  
40,000  
50,000  
60,000  
80,000  
1,060 1,600 2,100 2,600 4,100  
1,100 1,900 2,700 3,500 6,200 8,500  
1,250 2,100 3,100 4,200 7,000 9,500  
1,400 2,400 3,500 4,600 8,000 10,800  
1,500 2,600 3,900 5,000 8,300 11,500  
1,600 2,800 4,000 5,250 9,000 12,000  
1,700 2,850 4,300 5,500 9,500 12,500  
1,800 3,000 4,600 5,800 9,800 13,500  
1,900 3,200 4,800 6,300 10,200 14,000  
2,000 3,500 5,200 6,700 11,000 15,000  
2,200 3,900 5,700 7,200 12,200 16,000  
1,350 2,000 2,800 3,400 5,250 8,000  
1,600 2,300 3.200 3,900 6,000 9,000  
1,700 2,600 3,600 4,500 6,700 10,000  
1,900 2,800 3,800 4,800 7,500 11,000  
2,000 3,000 4,100 5,200 8,000 12,000  
2,100 3,100 4,400 5,700 8,500 12,500  
2,200 3,300 4,600 6,000 9,000 13,000  
2,400 3,500 4,900 6,500 9,500 14,000  
2,500 3,800 5,200 7,000 10,000 15,000  
2,700 4,000 5,700 7,750 11,000 17,000  
100,000 2,300 4,000 6,000 8,100 12,700 17,000  
150,000 2,500 4,500 6,700 9,100 14,000 19,000  
200,000 2,600 4,800 7,000 9,700 15,000 20,000  
100,000 2,900 4,200 6,200 8,500 12,000 18,000  
150,000 3,200 4,600 7,300 10,000 14,000 21,000  
200,000 3,300 4,700 8,000 11,000 16,000 23,000  
LLSRK  
LLNRK  
1000000  
800000  
600000  
1000000  
800000  
600000  
400000  
300000  
400000  
300000  
200000  
200000  
100000  
80000  
60000  
100000  
80000  
60000  
40000  
30000  
20000  
600A  
400A  
200A  
100A  
600A  
400A  
40000  
30000  
200A  
20000  
100A  
60A  
60A  
10000  
10000  
8000  
6000  
8000  
30A  
30A  
6000  
4000  
3000  
4000  
3000  
2000  
2000  
1000  
800  
600  
1000  
800  
600  
400  
300  
400  
300  
200  
200  
100  
100  
AVAILABLE FAULT CURRENT  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
SYMMETRICAL R. M. S. AMPERES  
14  

相关型号:

LLNRK17.5

Electric Fuse, Time Delay Blow, 17.5A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK175

Electric Fuse, Time Delay Blow, 175A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK2.25

Electric Fuse, Time Delay Blow, 2.25A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK2.50

Electric Fuse, Time Delay Blow, 0.25A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK2.80

Electric Fuse, Time Delay Blow, 2.8A, 250VAC, 125VDC, 20000A (IR), Inline/holder,
LITTELFUSE

LLNRK200

Electric Fuse, Time Delay Blow, 200A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK225

Electric Fuse, Time Delay Blow, 225A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK250

Electric Fuse, Time Delay Blow, 250A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK3.20

Electric Fuse, Time Delay Blow, 3.2A, 250VAC, 125VDC, 20000A (IR), Inline/holder,
LITTELFUSE

LLNRK300

Electric Fuse, Time Delay Blow, 300A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK350

Electric Fuse, Time Delay Blow, 350A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE

LLNRK4.50

Electric Fuse, Time Delay Blow, 450A, 250VAC, 125VDC, 200000A (IR), Inline/holder,
LITTELFUSE