DBFE-200U240 [LINKCOM]
Power Supply;型号: | DBFE-200U240 |
厂家: | LINKCOM MANUFACTURING CO., LTD. |
描述: | Power Supply |
文件: | 总5页 (文件大小:631K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Power Supply
200-DBFE Series
FEATURES:
● AC Input 100~277VAC
● Built-in Active PFC Function
● Protection: SCP / OVP / OTP
● 0-10V Dimming Control
● Flicker Free
● High Operating Ambient Temp.: -30℃~+60℃
● Surge protection: L-N 4KV, L-FG/N-FG 6KV
● Safety: UL 8750 / PSE
● EMI: FCC Part 15 Class B / CE
● IP 67 Compliant
● Warranty: 5 years (refer to warranty policy)
● RoHS Compliant
PRODUCT SPECIFICATION
DC OUTPUT DC OUTPUT OUTPUT
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY (Typ.)
Power Factor (Typ.)
MODEL
POWER
(W)
VOLTAGE CURRENT
(V)
(A)
100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC
DBFE-200U120
DBFE-200U240
DBFE-200U360
DBFE-200U420
DBFE-200U480
192
8-12
16
8.4
5.6
4.8
4.2
±5%
±5%
±5%
±5%
±5%
88.0% 89.0% 91.0% 92.0% 0.98
90.0% 91.0% 93.0% 94.0% 0.98
90.0% 91.0% 93.0% 94.0% 0.98
90.0% 91.0% 93.0% 94.0% 0.98
90.0% 91.0% 93.0% 94.0% 0.98
0.98
0.98
0.98
0.98
0.98
0.95
0.95
0.95
0.95
0.95
0.93
0.93
0.93
0.93
0.93
201.6
201.6
201.6
201.6
18-24
27-36
32-42
36-48
Input Specifications
Min.
90
Typ.
Max.
305
63
Conditions/Description
Units
Vac
Hz
Input Voltage Range
Input Frequency Range
Input Current
47
3.6
100VAC in
230VAC in,25℃ Cold start
A
A
Inrush Current
70
Leakage Current
0.7
277VAC in
mA
Power Factor (PF)
0.9
100-277VAC,100% load
Total Harmonics Distortion (THD)
Output Specifications
20
%
Min.
Typ.
Max.
±3
Conditions/Description
Units
%
Line Regulation
Load Regulation
±3
%
Output Current Regulation
Ripple and Noise (pk-pk)
5
%
0.5
20MHz Bandwidth. See note (3)
V
*Measured at electronic load LED mode and nominal input voltage
with DC10V dimming.
Ripple Current
<30% of rated output current
3
Turn-on Delay Time
*Measured at 100-277VAC and at full load
s
Protection Functions
Min.
Typ.
Max.
Conditions/Description
Units
Short Circuit Protection
Auto recovery
Auto recovery
Auto recovery
Over Voltage Protection
Over Temp Protection (Tc)
Environmental Conditions
105
℃
Min.
-30
10
Typ.
Max.
60
Conditions/Description
Non-condensing
Units
℃
Operating Temperature (Ta)
Operating Humidity
Operating Case Temperature (Tc)
Storage Temperature
Storage Humidity
90
Non-condensing
%RH
℃
90
Case temperature measured at the case hot spot
Non-condensing
-40
10
80
℃
95
Non-condensing
%RH
Life Time
Measured at 277Vac, 57,000 hours at Tc 75°C .
246.4 * 74 * 43.55 mm
9.7 * 2.91 * 1.71 inch
Dimensions(L*W*H)
Weight
1400
g
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
Power Supply
200-DBFE Series
EMC Compliance and Safety
EMC Compliance
Conducted and Radiated Emmission
Harmonic Current Emissions
Comply with EN 55015 (CISPR15) , Comply with FCC Part 15 Class B
Comply with EN 61000-3-2 Class C
Voltage Fluctuations & Flicker
Comply with EN 61000-3-3
Electrostatic Discharge (ESD)
Comply with IEC 61000-4-2
8 KV air discharge, 4 KV contact discharge
RF Electromagnetic Field
Susceptibility
Comply with IEC 61000-4-3
Electrical Fast Transient
Surge Immunity
Comply with IEC 61000-4-4
Comply with IEC 61000-4-5
Comply with IEC 61000-4-6
EMS Standards
L-N 4KV, L-FG/N-FG 6KV
Conducted RF Disturbances
Power Frequency Magnetic Field Comply with IEC 61000-4-8
Voltage Dips
Comply with IEC 61000-4-11
Safety
UL
PSE
Comply with UL 8750
PSE
Notes
(1) All parameters not specially mentioned are measured 230VAC input.
(2) All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
*REFERENCE: www.linkcom.com.tw
*Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
Power Supply
200-DBFE Series
DERATING CURVE
DIMENSIONS
Tc Max.
DBFE-200U120 as Tc Max. Reference
*REFERENCE: www.linkcom.com.tw
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
Power Supply
200-DBFE Series
DIMMING OPERATION
Parameters
Minimum
1V
Typical
─
Maximum
10V
Absolute maximum voltageon on the 0-10(+) Purple Wire
Source current on the 0-10V(+) Purple Wire
0mA
─
1mA
RED (LED+)
BLACK (LED-)
DBFE Series
PURPLE (DIM+)
GRAY (DIM-)
Dimmer
Notes:
1. Purple and Gray wires on the output side are used for 0-10V dimming.
2. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent.
3. When dimming wires +Purple/-Gray are left open, the output current will be at 100%.
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
Power Supply
200-DBFE Series
Output Current vs. Load (DBFE-200U420)
Output Current vs. Load
4.900
4.800
4.700
4.600
4.500
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load(%)
Efficiency vs. Load (DBFE-200U420)
Efficiency vs. Load
95%
90%
85%
80%
75%
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load(%)
PF vs. Load (DBFE-200U420)
PF vs. Load
1.00
0.95
0.90
0.85
0.80
Vin=100
Vin=120
Vin=200
Vin=230
Vin=277
70%
75%
80%
85%
90%
95%
100%
105%
Load(%)
Linkcom Manufacturing Co., Ltd.