JRCK017A0S32R06435Z [LINEAGEPOWER]

36–62 Vdc Input; 32Vdc Output; 17Adc Output;
JRCK017A0S32R06435Z
型号: JRCK017A0S32R06435Z
厂家: LINEAGE POWER CORPORATION    LINEAGE POWER CORPORATION
描述:

36–62 Vdc Input; 32Vdc Output; 17Adc Output

文件: 总15页 (文件大小:1165K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Data Sheet  
GE  
JRCK017A0S32R0 Orca* Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32Vdc Output; 17Adc Output  
Features  
RoHS Compliant  
.
.
.
.
.
.
.
.
Compliant to RoHS II EU Directive 2011/65/EC (-Z versions)  
Compliant to REACH Directive (EC) No 1907/2006  
High power density: 166 W/in3  
Very high efficiency: >95% Typ at Full Load  
Industry standard half-brick pin-out  
Low output ripple and noise  
Supports repetitive loads (AC+DC) up to 2 kHz  
Industry standard, DOSA compliant half-brick footprint  
57.7mm x 60.7mm x 12.7mm  
(2.27” x 2.39” x 0.5”)  
.
.
.
.
.
.
.
.
.
.
.
Remote Sense  
2:1 input voltage range  
Single tightly regulated output  
Applications  
Constant switching frequency  
.
.
.
RF Power Amplifier  
Constant Current Overcurrent limit  
Latch after short circuit fault shutdown  
Over temperature protection auto restart  
Output voltage adjustment trim, 16.0Vdc to 35.2Vdc  
Wide operating case temperature range (-40°C to 100°C)  
CE mark meets 2006/95/EC directives§  
Wireless Networks  
Switching Networks  
Options  
.
.
.
.
Output OCP/OVP auto restart  
ANSI/UL# 60950-1, 2nd Ed. Recognized, CSAC22.2 No.  
60950-1-07 Certified, and VDE0805-1 (EN60950-1, 2nd  
Ed.) Licensed  
Shorter pins  
Unthreaded heatsink holes  
.
.
ISO** 9001 and ISO 14001 certified manufacturing facilities  
Compliant to IPC-9592A, Category 2, Class II  
Tunable Loop* for transient response optimization  
Description  
The JRCK017S32R0 ORCA series of dc-dc converters are a new generation of isolated, very high efficiency DC/DC power modules  
providing up to up to 17Adc output current at a nominal output voltage of 32Vdc in an industry standard, DOSA compliant half-  
brick size footprint, which makes it an ideal choice for high voltage and high power applications. Threaded-through holes are  
provided to allow easy mounting or addition of a heatsink for high-temperature applications. The output is fully isolated from the  
input, allowing versatile polarity configurations and grounding connections. This module contains an optional new feature, the  
Tunable Loop, that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of  
output capacitance, leading to savings on cost and PWB area.  
*
Trademark of General Electric Company  
#
UL is a registered trademark of Underwriters Laboratories, Inc.  
CSA is a registered trademark of Canadian Standards Association.  
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.  
** ISO is a registered trademark of the International Organization of Standards  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 1  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
Continuous  
All  
All  
VIN  
-0.3  
-0.3  
62  
75  
Vdc  
Vdc  
Transient, operational (100 ms)  
VIN,trans  
Operating Ambient Temperature  
All  
All  
Ta  
Tc  
-40  
-40  
85  
°C  
°C  
Operating Case Temperature  
(See Thermal Considerations section, Figure 17)  
100  
Storage Temperature  
All  
All  
All  
Tstg  
-55  
125  
1500  
500  
°C  
Vdc  
Vdc  
I/O Isolation Voltage: Input to Case, Input to Output  
Output to Case  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
(see Figure 12 for VIN MIN when using trim-up feature)  
All  
VIN  
36  
48  
62  
Vdc  
Maximum Input Current  
(VIN=36V to 62V, IO=IO, max  
)
All  
All  
IIN,max  
I2t  
17.0  
2
Adc  
Inrush Transient  
A2s  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 62V, IO=  
IOmax ; see Figure 7)  
All  
All  
20  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
50  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an integrated  
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use an input line fuse,  
to achieve maximum safety and system protection. The safety agencies require a time-delay or fast-acting fuse with a maximum  
rating of 25 A in the ungrounded input connection (see Safety Considerations section). Based on the information provided in this  
data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the  
fuse manufacturer’s data sheet for further information.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 2  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Electrical Specifications (continued)  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Output Voltage Set-point  
(VIN=VIN,nom, IO=IO, max, Tc =25°C)  
All  
VO, set  
31.5  
32  
32.5  
Vdc  
Output Voltage Set-Point Total Tolerance  
(Over all operating input voltage, resistive load, and  
temperature conditions until end of life)  
All  
VO  
31.0  
33.0  
Vdc  
Output Regulation  
Line (VIN=VIN, min to VIN, max  
Load (IO=IO, min to IO, max  
Temperature (Tc = -40ºC to +100ºC)  
)
All  
All  
All  
0.1  
0.1  
0.2  
0.2  
0.02  
%Vo,set  
%Vo,set  
%/°C  
)
Output Ripple and Noise on nominal output  
(VIN=VIN, nom and IO=IO, min to IO, max  
)
RMS (5Hz to 20MHz bandwidth)  
Peak-to-Peak (5Hz to 20MHz bandwidth)  
External Capacitance (ESR > 2.5 m)1  
Without the Tunable Loop (ESRMAX = 80m)1  
With the Tunable Loop (ESR > 50 m)2  
Output Power (Vo=32V to 35.2V)  
Output Current  
Output Current Limit Inception (Constant current until  
Vo<VtrimMIN , duration <4s)  
All  
All  
45  
80  
55  
200  
mVrms  
mVpk-pk  
μF  
μF  
μF  
440  
440  
440  
All, except -T  
CO  
CO,  
CO  
PO,max  
Io  
6500  
470  
10,000  
544  
-T  
-T  
All  
All  
W
Adc  
0
17.0  
All  
All  
IO, lim  
IO, sc  
18.5  
22.0  
2
Adc  
Output Short Circuit Current (VO0.25Vdc  
)
Arms  
Efficiency  
VIN=VIN, nom, Tc=25°C IO=IO, max , VO= VO,set  
All  
η
95.0  
95.1  
175  
%
Switching Frequency  
fsw  
kHz  
Dynamic Load Response  
(Io/t=1.0A/10s; VIN=VIN,nom; Tc=25°C;  
Tested with a 470 μF aluminum and a 10 µF ceramic  
capacitor across the load.)  
Load Change from IO= 25%-50%-25% of IO,max  
:
Peak Deviation  
Settling Time (VO<10% peak deviation)  
Load Change from IO= 50%-75%-50% of IO,max  
All  
All  
Vpk  
ts  
2
1.5  
%VO, set  
ms  
:
Vpk  
ts  
2
1.5  
%VO, set  
ms  
Peak Deviation  
Settling Time (VO<10% peak deviation)  
(Io/t=2.0A/s; VIN=VIN,nom; TC=25°C;  
Tested with a 3x330 μF aluminum and a 10 µF ceramic  
capacitor across the load.  
AC Load (100Hz, 50% duty cycle) Change from IO= 0%-75%-0%  
Vpk  
ts  
4
1.5  
%VO, set  
ms  
All  
All  
of IO,max  
Peak Deviation  
Load Change from IO= 75% to 50% of IO,max  
:
:
Vpk  
ts  
4
1.5  
%VO, set  
ms  
Peak Deviation  
Settling Time (VO<10% peak deviation)  
(Io/t=10%IO,max /10s; VIN=VIN,nom; Tc=25°C; Tested with a 3000  
μF aluminum and a 10 µF ceramic capacitor across the load,  
see Figure 16.  
Load Change from IO= 0%-120% of IO,max  
Peak Deviation  
Settling Time (VO<10% peak deviation)  
:
Vpk  
ts  
2
1.5  
%VO, set  
ms  
All  
All  
Load Change from Io= 120% to 50% of Io,max:  
Peak Deviation  
Vpk  
ts  
2
1.5  
%VO, set  
ms  
Settling Time (Vo<10% peak deviation)  
1 Note: use a minimum 2 x 220uF output capacitor. Recommended capacitor is Nichicon CD series, 220uF/35V. If the ambient temperature is less  
than -20OC, use more than 3 of recommended minimum capacitors.  
2 External capacitors may require using the new Tunable Loop feature to ensure that the module is stable as well as getting the best transient  
response. See the Tunable Loop section for details.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 3  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Isolation Specifications  
Parameter  
Symbol  
Ciso  
Min  
Typ  
15  
Max  
Unit  
nF  
Isolation Capacitance  
Isolation Resistance  
Riso  
10  
Mꢀ  
General Specifications  
Parameter  
Device  
All  
Symbol  
Min  
Typ  
Max  
Unit  
109/Hours  
Hours  
Calculated Reliability based upon Telcordia SR-332 Issue 2:  
FIT  
476.1  
Method I Case 3 (IO=80%IO, max, TA=40°C, airflow = 200 lfm, 90%  
confidence)  
Weight  
MTBF  
2,100,581  
76.4 (2.69)  
All  
g (oz.)  
Feature Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See  
Feature Descriptions for additional information.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Remote On/Off Signal Interface  
(VIN=VIN, min to VIN, max ; open collector or equivalent,  
Signal referenced to VIN- terminal)  
Negative Logic: device code suffix “1”  
Logic Low = module On, Logic High = module Off  
Positive Logic: No device code suffix required  
Logic Low = module Off, Logic High = module On  
Logic Low - Remote On/Off Current  
Logic Low - On/Off Voltage  
Logic High Voltage – (Typ = Open Collector)  
Logic High maximum allowable leakage current  
All  
All  
All  
All  
Ion/off  
Von/off  
Von/off  
Ion/off  
0
1.0  
1.2  
5
mA  
Vdc  
Vdc  
μA  
50  
Turn-On Delay and Rise Times  
(Vin=Vin,nom, IO=IO, max, 25C)  
Case 1: Tdelay = Time until VO = 10% of VO,set from application  
of Vin with Remote On/Off set to ON,  
All  
Tdelay  
120  
ms  
ms  
Case 2: Tdelay = Time until VO = 10% of VO,set from application of  
Remote On/Off from Off to On with Vin already applied for at  
least one second.  
All  
All  
Tdelay  
20  
55  
Trise = time for VO to rise from 10% of VO,set to 90% of VO,set  
.
Trise  
45  
65  
3
ms  
Output Voltage Overshoot  
(IO=80% of IO, max, TA=25°C)  
% VO, set  
Output Voltage Adjustment  
(See Feature Descriptions):  
Output Voltage Remote-sense Range  
(only for No Trim or Trim down application )  
__  
__  
All  
Vsense  
2
%Vo,nom  
Output Voltage Set-point Adjustment Range (trim)  
Output Overvoltage Protection  
All  
All  
All  
Vtrim  
VO, limit  
Tref  
16.0  
37  
---  
35.2  
39  
Vdc  
Vdc  
°C  
Over Temperature Protection  
110  
(See Feature Descriptions, Figure 17)  
Input Under Voltage Lockout  
VIN, UVLO  
Turn-on Threshold  
Turn-off Threshold  
Hysteresis  
All  
All  
All  
35  
32.5  
3
36  
Vdc  
Vdc  
Vdc  
30.5  
Input Over voltage Lockout  
October 11, 2013  
VIN, OVLO  
Turn-on Threshold  
Turn-off Threshold  
Hysteresis  
All  
All  
All  
62  
68  
3
66  
---  
Vdc  
Vdc  
Vdc  
66  
---  
©2012 General Electric Company. All rights reserved.  
Page 4  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Characteristic Curves  
The following figures provide typical characteristics for the JRCK017S32R0 (32V, 17A) at 25ºC. The figures are identical for either  
positive or negative Remote On/Off logic.  
OUTPUT CURRENT, Io (A)  
TIME, t (20ms/div)  
Figure 1. Converter Efficiency versus Output Current.  
Figure 4. Typical Start-Up Using positive Remote On/Off; Co,ext  
= 440µF.  
TIME, t (40ms/div)  
TIME, t (1s/div)  
Figure 2. Typical Output Ripple and Noise at Room  
Temperature and 48Vin; Io = Io,max; Co,ext = 440µF.  
Figure 5. Typical Start-Up from VIN, on/off enabled prior to VIN  
step; Co,ext = 470µF.  
TIME, t (2ms/div)  
TIME, t (2ms/div)  
Figure 3. Dynamic Load Change Transient Response from  
25% to 50% to 25% of Full Load at Room Temperature and  
48 Vin; 0.1A/uS, Co,ext = 440µF.  
Figure 6. Dynamic Load Change Transient Response from 50  
% to 75% to 50% of Full Load at Room Temperature and 48  
Vin; 0.1A/uS, Co,ext = 440µF.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 5  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Test Configurations  
Design Considerations  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance source. A highly inductive source impedance  
can affect the stability of the power module. For the test  
configuration in Figure 7, a 470μF Low ESR aluminum  
capacitor, CIN , mounted close to the power module helps  
ensure the stability of the unit. Consult the factory for further  
application guidelines.  
Output Capacitance  
The JRCK017S32R0 power module requires a minimum  
output capacitance of 440µF Low ESR aluminum capacitor,  
Cout to ensure stable operation over the full range of load and  
line conditions, see Figure 8. If the ambient temperature is  
under -20C, it is required to use at least 3 pcs of minimum  
capacitors in parallel. In general, the process of determining  
the acceptable values of output capacitance and ESR is  
complex and is load-dependent.  
Note: Measure the input reflected-ripple current with a simulated  
source inductance (LTEST) of 12 µH. Capacitor CS offsets possible  
battery impedance. Measure the current, as shown above.  
Figure 7. Input Reflected Ripple Current Test Setup.  
Safety Considerations  
For safety-agency approval of the system in which the power  
module is used, the power module must be installed in  
compliance with the spacing and separation requirements of  
the end-use safety agency standard, i.e., UL 60950-1, 2nd Ed.,  
CSA No. 60950-1 2nd Ed., and VDE0805-1 EN60950-1, 2nd Ed.  
Note: Use a Cout (470 µF Low ESR aluminum or tantalum capacitor  
typical), a 0.1 µF ceramic capacitor and a 10 µF ceramic capacitor,  
and Scope measurement should be made using a BNC socket.  
Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the  
module.  
For end products connected to –48V dc, or –60Vdc nominal  
DC MAINS (i.e. central office dc battery plant), no further fault  
testing is required. *Note: -60V dc nominal battery plants are  
not available in the U.S. or Canada.  
Figure 8. Output Ripple and Noise Test Setup.  
For all input voltages, other than DC MAINS, where the input  
voltage is less than 60V dc, if the input meets all of the  
requirements for SELV, then:  
.
The output may be considered SELV. Output voltages will  
remain within SELV limits even with internally-generated  
non-SELV voltages. Single component failure and fault  
tests were performed in the power converters.  
Note: All measurements are taken at the module terminals. When  
socketing, place Kelvin connections at module terminals to avoid  
measurement errors due to socket contact resistance.  
.
One pole of the input and one pole of the output are to  
be grounded, or both circuits are to be kept floating, to  
maintain the output voltage to ground voltage within ELV  
or SELV limits. However, SELV will not be maintained if  
VI(+) and VO(+) are grounded simultaneously.  
Figure 9. Output Voltage and Efficiency Test Setup.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 6  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Safety Considerations (continued)  
For all input sources, other than DC MAINS, where the input  
voltage is between 60 and 75V dc (Classified as TNV-2 in  
Europe), the following must be meet, if the converter’s output  
is to be evaluated for SELV:  
.
The input source is to be provided with reinforced  
insulation from any hazardous voltage, including the ac  
mains.  
.
.
One Vi pin and one Vo pin are to be reliably earthed, or  
both the input and output pins are to be kept floating.  
Another SELV reliability test is conducted on the whole  
system, as required by the safety agencies, on the  
combination of supply source and the subject module to  
verify that under a single fault, hazardous voltages do  
not appear at the module’s output.  
Figure 10. Circuit configuration for using Remote On/Off  
Implementation.  
Overcurrent Protection  
To provide protection in a fault output overload condition, the  
module is equipped with internal current limiting protection  
circuitry, and can endure continuous overcurrent by providing  
constant current output, for up to 4 seconds, as long as the  
output voltage is greater than VtrimMIN. If the load resistance is  
to low to support VtrimMIN in an overcurrent condition or a short  
circuit load condition exists, the module will shutdown  
immediately.  
All flammable materials used in the manufacturing of these  
modules are rated 94V-0, or tested to the UL60950 A.2 for  
reduced thickness.  
The input to these units is to be provided with a maximum 25  
A fast-acting or time-delay fuse in the ungrounded input  
connection.  
Feature Description  
A latching shutdown option is standard. Following shutdown,  
the module will remain off until the module is reset by either  
cycling the input power or by toggling the on/off pin for one  
second.  
An auto-restart option (4) is also available in a case where an  
auto recovery is required. If overcurrent greater than 19A  
persists for few milli-seconds, the module will shut down and  
auto restart until the fault condition is corrected. If the output  
overload condition still exists when the module restarts, it will  
shut down again. This operation will continue indefinitely, until  
the overcurrent condition is corrected.  
Remote On/Off  
Two remote on/off options are available. Positive logic turns  
the module on during a logic high voltage on the ON/OFF pin,  
and off during a logic low. Negative logic remote On/Off,  
device code suffix “1”, turns the module off during a logic high  
and on during a logic low.  
To turn the power module on and off, the user must supply a  
switch (open collector or equivalent) to control the voltage  
(Von/off) between the ON/OFF terminal and the VIN(-) terminal  
(see Figure 10). Logic low is 0V Von/off 1.2V. The maximum  
Ion/off during a logic low is 1mA, the switch should be maintain  
a logic low level whilst sinking this current.  
Over Voltage Protection  
The output overvoltage protection consists of circuitry that  
monitors the voltage on the output terminals. If the voltage on  
the output terminals exceeds the over voltage protection  
threshold, then the module will shutdown and latch off. The  
overvoltage latch is reset by either cycling the input power for  
one second or by toggling the on/off signal for one second.  
The protection mechanism is such that the unit can continue  
in this condition until the fault is cleared.  
During a logic high, the typical maximum Von/off generated by  
the module is 5V, and the maximum allowable leakage  
current at Von/off = 5V is 50μA.  
If not using the remote on/off feature:  
For positive logic, leave the ON/OFF pin open.  
For negative logic, short the ON/OFF pin to VIN(-).  
An auto-restart option (4) is also available in a case where an  
auto recovery is required.  
Remote sense  
Remote sense minimizes the effects of distribution losses by  
regulating the voltage at the remote-sense connections (see  
Figure 11). For No Trim or Trim down application, the voltage  
between the remote-sense pins and the output terminals  
must not exceed the output voltage sense range given in the  
Feature Specifications table i.e.:  
[VO(+)–VO(-)] – [SENSE(+) – SENSE(-)] 2% of Vo,nom  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 7  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Feature Description (continued)  
If not using the trim down feature, leave the TRIM pin open.  
The voltage between the Vo(+) and Vo(-) terminals must not  
Trim Down – Decrease Output Voltage  
exceed the minimum output overvoltage shut-down value  
indicated in the Feature Specifications table. This limit  
includes any increase in voltage due to remote-sense  
compensation and output voltage set-point adjustment (trim).  
See Figure 11. If not using the remote-sense feature to  
regulate the output at the point of load, then connect  
SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the module.  
With an external resistor (Radj_down) between the TRIM and  
SENSE(-) pins, the output voltage set point (Vo,adj) decreases  
(see Figure 13). The following equation determines the  
required external-resistor value to obtain a percentage output  
voltage change of %.  
For output voltages: VO,nom = 32V  
Although the output voltage can be increased by both the  
remote sense and by the trim, the maximum increase for the  
output voltage is not the sum of both. The maximum increase  
is the larger of either the remote sense or the trim. The  
amount of power delivered by the module is defined as the  
voltage at the output terminals multiplied by the output  
current. When using remote sense and trim: the output  
voltage of the module can be increased, which at the same  
output current would increase the power output of the  
module. Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
Without –T Option  
With –T Option  
100  
1000  
Radj _ down  
2 k  
Radj _ down  
11 k  
%  
%  
Where,  
V
o, nom V  
desired 100  
%   
V
o, nom  
Vdesired = Desired output voltage set point (V).  
Figure 11. Effective Circuit Configuration for Single-Module  
Remote-Sense Operation Output Voltage.  
Figure 13. Circuit Configuration to Decrease Output  
Voltage.  
Output Voltage Programming  
Trim Up – Increase Output Voltage  
Trimming allows the user to increase or decrease the output  
voltage set point of a module. Trimming down is  
accomplished by connecting an external resistor between the  
TRIM pin and the SENSE(-) pin. Trimming up is accomplished  
by connecting external resistor between the SENSE(+) pin and  
TRIM pin. The trim resistor should be positioned close to the  
module. Certain restrictions apply to the input voltage lower  
limit when trimming the output voltage to the maximum. See  
Figure 12 for the allowed input to output range when using  
trim.  
With an external resistor (Radj_up) connected between the  
SENSE(+) and TRIM pins, the output voltage set point (Vo,adj  
increases (see Figure 14).  
)
The following equation determines the required external-  
resistor value to obtain a percentage output voltage  
change of %. For output voltages: VO,nom = 32V  
Without –T Option  
V
(100 %)  
(100 (2 %)  
%  
O ,nom  
R
adj  
_
up  
k  
1.225 %  
With –T Option  
27122  
Radj _ up  
15.12 k  
%  
Where,  
V
desired Vo, nom  
%   
100  
Vo, nom  
Vdesired = Desired output voltage set point (V).  
Figure 12. Output Voltage Trim Limits vs. Input Voltage.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 8  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
the voltage step and range of the DAC and the desired values  
Feature Description (continued)  
for trim-up and trim-down %. Please contact your GE  
technical representative to obtain more details on the  
selection for this resistor.  
Figure 14. Circuit Configuration to Increase Output Voltage.  
The voltage between the Vo(+) and Vo(-) terminals must not  
exceed the minimum output overvoltage shut-down value  
indicated in the Feature Specifications table. This limit  
includes any increase in voltage due to remote- sense  
compensation and output voltage set-point adjustment (trim).  
See Figure 11.  
Figure 15. Circuit Configuration to Actively Adjust the  
Output Voltage.  
AC+DC Load Capability  
The JRCK017S32R0x is compatible with load profiles as shown  
in Figure 16.  
Although the output voltage can be increased by both the  
remote sense and by the trim, the maximum increase for the  
output voltage is not the sum of both. The maximum increase  
is the larger of either the remote sense or the trim. The  
amount of power delivered by the module is defined as the  
voltage at the output terminals multiplied by the output  
current. When using remote sense and trim, the output  
voltage of the module can be increased, which the same  
output current would increase the power output of the  
module. Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
Examples:  
To trim down the output of a nominal 32V module, without –T  
option, to 16.8V  
28 16.8  
%   
100 40%  
28  
100  
Radj _ down  
2 0.5k  
40  
To trim up the output of a nominal 32V module, without –T  
option, to 30.8V  
Figure 16. AC-DC Load Profile  
30.828  
The output voltage peak deviation shall not exceed the peak  
values listed in the Electrical Specifications Table.  
%   
100 10.0%  
28  
28 (100 10 ) (100 (2 10 )  
Tunable Loop  
R
adj _ up  
1.225 10  
10  
The JRCK017S32R0x-T modules have a new feature that  
optimizes transient response of the module called Tunable  
Loop.  
R
adj_up = 239k  
Active Voltage Programming  
External capacitors are usually added to the output of the  
module for two reasons: to reduce output ripple and noise  
and to reduce output voltage deviations from the steady-  
state value in the presence of dynamic load current changes.  
For both the JRCK017S32R0x and JRCK017S32R0x-T, a  
Digital-Analog converter (DAC), capable of both sourcing and  
sinking current, can be used to actively set the output voltage,  
as shown in Figure 15. The value of RG will be dependent on  
Adding external capacitance however affects the voltage  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 9  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Feature Description (continued)  
control loop of the module, typically causing the loop to slow  
down with sluggish response. Larger values of external  
capacitance could also cause the module to become  
unstable.  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be provided  
to help ensure reliable operation.  
Considerations include ambient temperature, airflow, module  
power dissipation and the need for increased reliability. A  
reduction in the operating temperature of the module will  
result in an increase in reliability.  
The Tunable LoopTM allows the user to externally adjust the  
voltage control loop to match the filter network connected to  
the output of the module. The Tunable LoopTM is implemented  
by connecting a series R-C between the SENSE(+) and TRIM  
pins of the module, as shown in Fig. 17. This R-C allows the  
user to externally adjust the voltage loop feedback  
compensation of the module.  
The thermal data presented here is based on physical  
measurements taken in a wind tunnel, using automated  
thermo-couple instrumentation to monitor key component  
temperatures: FETs, diodes, control ICs, magnetic cores,  
ceramic capacitors, opto-isolators, and module pwb  
conductors, while controlling the ambient airflow rate and  
temperature. For a given airflow and ambient temperature,  
the module output power is increased, until one (or more) of  
the components reaches its maximum derated operating  
temperature, as defined in IPC-9592. This procedure is then  
repeated for a different airflow or ambient temperature until a  
family of module output derating curves is obtained.  
Figure 17. Circuit diagram showing connection of RTUNE and  
CTUNE to tune the control loop of the module.  
Table 1 shows the recommended values of RTUNE and CTUNE for  
different values of ceramic output capacitors up to 8000 F  
that might be needed for an  
application to meet output ripple and noise requirements.  
Table 1. General recommended values of of RTUNE and CTUNE  
for Vout=32V and various external ceramic capacitor  
combinations.  
Cout(µF)  
ESR (m)  
RTUNE  
1100  
2200  
4400  
6600  
8800  
60  
*
30  
*
15  
*
10  
*
7.5  
*
CTUNE  
*
*
*
*
*
Heat-dissipating components inside the unit are thermally  
coupled to the case. Heat is removed by conduction,  
convection, and radiation to the surrounding environment.  
Proper cooling can be verified by measuring the case  
temperature. Peak temperature locations (Tref) occur at the  
positions indicated in Figure 18.  
* contact GE technical support  
Please contact your GE technical representative to obtain  
more details of this feature as well as for guidelines on how to  
select the right value of external R-C to tune the module for  
best transient performance and stable operation for other  
output capacitance values.  
For reliable operation, these temperatures should not  
exceed the values listed below for applications using forced  
convection airflow or coldwall applications.  
Over Temperature Protection  
The JRCK017S32R0 module provides a non-latching over  
temperature protection. A temperature sensor monitors the  
operating temperature of the converter. If the reference  
temperature, TREF 1, (see Figure 17) exceeds a threshold of 115  
ºC (typical), the converter will shut down and disable the  
output. When the base plate temperature has decreased by  
approximately 20 ºC the converter will automatically restart.  
Application  
Coldwall  
Tref1  
99  
Tref2  
100  
Heatplate only, or w/Heatsink  
95  
100  
The output power of the module should not exceed the rated  
power for the module as listed in the ordering Information  
table. Although the maximum TREF temperature of the power  
modules is discussed above, you can limit this temperature to  
a lower value for extremely high reliability.  
The module can be restarted by cycling the dc input power for  
at least one second or by toggling the remote on/off signal for  
at least one second.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 10  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Thermal Considerations (continued)  
Ambient Temperature, TA (oC)  
Figure 20. Derating Output Current vs. local Ambient  
temperature and Airflow, No Heatsink, Vin=48V, airflow  
from Vi(-) to Vi(+).  
Figure 18. Case (Tref ) Temperature Measurement Locations  
(top view).  
Thermal Derating  
Thermal derating is presented for two different applications:  
1) Figure 19, the JRCK017S32R0 module is thermally coupled  
to a cold plate inside a sealed clamshell chassis, without any  
internal air circulation; and 2) Figure 20, 21 and 22, the  
JRCK017S32R0 module is mounted in a traditional open  
chassis or cards with forced air flow. In application 1, the  
module is cooled entirely by conduction of heat from the  
module primarily through the top surface to a cold plate, with  
some conduction through the module’s pins to the power  
layers in the system board. For application 2, the module is  
cooled by heat removal into a forced airflow that passes  
through the interior of the module and over the top base plate  
Ambient Temperature, TA (oC)  
and/or attached heatsink.  
Figure 21. Derating Output Current vs. local Ambient  
temperature and Airflow, 0.5” Heatsink, Vin=48V,  
airflow from Vi(-) to Vi(+).  
Cold plate (inside surface) temperature (ºC)  
Figure 19. Output Power Derating for JRCK017S32R0 in  
Conduction cooling (cold plate) applications; Ta <70ºC  
adjacent to module; VIN = VIN,NOM  
Ambient Temperature, TA (oC)  
Figure 22. Derating Output Current vs. local Ambient  
temperature and Airflow, 1.0” Heatsink, Vin=48V,  
airflow from Vi(-) to Vi(+).  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 11  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Layout Considerations  
Through-Hole Lead-Free Soldering  
Information  
The JRCK017S32R0 power module series are constructed  
using a single PWB with integral base plate; as such,  
component clearance between the bottom of the power  
module and the mounting (Host) board is limited. Avoid  
placing copper areas on the outer layer directly underneath  
the power module.  
The RoHS-compliant through-hole products use the SAC  
(Sn/Ag/Cu) Pb-free solder and RoHS-compliant components.  
They are designed to be processed through single or dual  
wave soldering machines. The pins have an RoHS-compliant  
finish that is compatible with both Pb and Pb-free wave  
soldering processes. A maximum preheat rate of 3C/s is  
suggested. The wave preheat process should be such that  
the temperature of the power module board is kept below  
210C. For Pb solder, the recommended pot temperature is  
260C, while the Pb-free solder pot is 270C max. The  
JRCK017S32R0 can not be processed with paste-through-  
hole Pb or Pb-free reflow process. If additional information is  
needed, please consult with your GE representative for more  
details.  
Post Solder Cleaning and Drying Considerations  
Post solder cleaning is usually the final circuit-board assembly  
process prior to electrical board testing. The result of  
inadequate cleaning and drying can affect both the reliability  
of a power module and the testability of the finished  
circuit-board assembly. For guidance on appropriate  
soldering, cleaning and drying procedures, refer to GE Board  
Mounted Power Modules: Soldering and Cleaning Application  
Note.  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 12  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Mechanical Outline for Through-Hole Module  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated)  
x.xx mm 0.25 mm [x.xxx in 0.010 in.]  
*Top side label includes GE name, product designation, and date code.  
TOP VIEW*  
SIDE VIEW**  
BOTTOM VIEW  
Pin Description  
1
2
3
4
5
6
7
8
9
Vin (+)  
On/Off  
Baseplate  
Vin (–)  
Vout (–)  
Sense (-)  
Trim  
Sense (+)  
Vout (+)  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 13  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Recommended Pad Layout for Through Hole Module  
Dimensions are in millimeters and [inches].  
Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in. ] (Unless otherwise indicated)  
x.xx mm 0.25 mm [x.xxx in 0.010 in. ]  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Page 14  
Data Sheet  
GE  
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules  
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output  
Ordering Information  
Please contact your GE Sales Representative for pricing, availability and optional features.  
Table 2. Device Code  
Output  
Voltage  
32V  
32V  
32V  
Output  
Current  
17A  
17A  
17A  
Connector  
Type  
Through hole  
Through hole  
Through hole  
Input Voltage  
Efficiency  
Product codes  
Comcodes  
150029595  
48V (36-62Vdc)  
48V (36-62Vdc)  
48V (36-62Vdc)  
95.1%  
95.1%  
95.1%  
JRCK017A0S32R064-18Z  
JRCK017A0S32R0641-18Z  
JRCK017A0S32R064-35Z  
150028490  
150032197  
Table 3. Device Options  
Contact Us  
For more information, call us at  
USA/Canada:  
+1 888 546 3243, or +1 972 244 9288  
Asia-Pacific:  
+86.021.54279977*808  
Europe, Middle-East and Africa:  
+49.89.878067-280  
India:  
+91.80.28411633  
www.ge.com/powerelectronics  
October 11, 2013  
©2012 General Electric Company. All rights reserved.  
Version 1.0  

相关型号:

JRCW016A0R

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R4118TZ

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R4118Z

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R41TZ

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R41Z

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R64118Z

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R6418Z

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW016A0R6435Z

36–75 Vdc Input; 28Vdc Output; 16Adc Output
LINEAGEPOWER

JRCW450R

36.75 Vdc Input; 32Vdc Output; 450W Output
LINEAGEPOWER

JRCW450R4118Z

36.75 Vdc Input; 32Vdc Output; 450W Output
LINEAGEPOWER

JRCW450R41TZ

36.75 Vdc Input; 32Vdc Output; 450W Output
LINEAGEPOWER

JRCW450R41Z

36.75 Vdc Input; 32Vdc Output; 450W Output
LINEAGEPOWER