CLP0212FPXX5Z01A [LINEAGEPOWER]

90 - 264Vac input; 12Vdc output; 200W Output Power;
CLP0212FPXX5Z01A
型号: CLP0212FPXX5Z01A
厂家: LINEAGE POWER CORPORATION    LINEAGE POWER CORPORATION
描述:

90 - 264Vac input; 12Vdc output; 200W Output Power

文件: 总15页 (文件大小:1475K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Features  
Compact size 50.8 mm x 101.6 mm x 36.1 mm  
(2 in x 4 in x 1.4 in) with density of 18W/in3  
Universal AC Input Range (90 – 264VAC)  
Output voltage of 12V (adjustable ±5%)  
Maximum output current of 16.7A@ 12Vout (200W)  
Standby output of 5V or 3.3V @ 0.25A  
High efficiency with 80 PLUS® Gold Certification  
Full load capability at 50ºC and 1m/s (200LFM) airflow  
with derating at higher temperatures or lower airflows  
Remote ON/OFF  
Output overcurrent protection (non-latching)  
Overtemperature protection  
Output overvoltage protection  
Up to 12ms of holdup time  
Parallellable with current sharing  
Active power factor corrected input  
Applications  
Conducted EMI - meets CISPR22 (EN55022) and FCC  
Class A requirements  
Telecommunications equipment  
Embedded Computing  
Storage Systems  
Compliant to RoHS EU Directive 2002/95/EC  
UL and cUL approved to UL/CSA60950-1, TUV  
(EN60950-1), CE Mark (for LVD) and CB Report available  
Industrial equipment  
ISO** 9001 and ISO 14001 certified manufacturing  
facilities  
Description  
In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energ  
efficiency. With its small size, the CLP series is specifically designed to handle power challenges associated with tight  
Offeringa leading 18W/in3 power density in a 1U high, fan- less form factor  
space and low airflow the CLP series addresses a  
y
.
,
broad range of applications in new products from communications, computing and data storage original equipment  
manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50˚C (122˚F) with  
higher temperature operation possible at derated output  
leveraging zero oltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits.  
Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperatur  
. The CLP series utilizes a unique design approach at this power level,  
v
e
(OTP).  
*
UL is a registered trademark of Underwriters Laboratories, Inc.  
CSA is a registered trademark of Canadian Standards Association.  
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.  
** ISO is a registered trademark of the International Organization of Standards  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings  
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations  
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.  
Parameter  
Device  
All  
Min  
90  
Max  
264  
70  
Unit  
Vac  
°C  
Input Voltage - Continuous  
Operating Ambient Temperature  
All  
-25  
(see Thermal Considerations section)  
CLP0212FPEX5Z01A  
-40‡  
-40‡  
70  
°C  
°C  
CLP0212FPEXZ02A  
CLP0212FPEX5Z03A  
85*  
(in sealed enclosure applications with thermally conductive pad to  
enclosure, PO,max = 65W)  
CLP0212FPEX5Z02A  
CLP0212FPEX5Z03A  
-40  
-40  
55†  
55†  
°C  
°C  
(in sealed enclosure applications with thermally conductive pad to  
enclosure, PO,max = 110W)  
Storage Temperature  
Humidity (non-condensing)  
Altitude  
All  
All  
All  
-40  
5
85  
95  
°C  
%
m
4000  
‡ Startup at -40ºC is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEXZ02A which can start up at full load.  
* Unit is capable of operation up to 85ºC ambient for brief periods of time provided humidity is kept below 40%. Sustained  
operation at 85ºC when input voltage is above 230VAC and output power loading is at or near the maximum rated value can  
degrade reliability of the product.  
† Ambient temperature outside the sealed enclosure containing the power supply.  
Electrical Specifications  
Parameter  
Device  
All  
Min  
90  
Typ  
Max  
264  
63  
Unit  
Vac  
Hz  
Operating Input Voltage  
Input Source Frequency  
115/230  
50/60  
All  
47  
All versions except  
CLP0212FPEXZ02A  
CLP0212FPEXZ02A  
Input Current (VIN = 90Vac)  
4
ARMS  
ARMS  
1.6  
Input Power Factor  
All  
All  
All  
All  
0.95  
12  
Inrush Transient Current (VIN = 264Vac, Tamb = 25ºC)  
Leakage Current to earth ground (VIN = 264Vac)  
Output Voltage Setpoint  
100  
2
A Peak  
mA  
Vdc  
Output Voltage Tolerance (due to set point, temperature variations,  
load and line regulation)  
All  
-2  
2
%
Output Voltage Adjustment Range  
Output Remote Sense Range  
Output Load Regulation  
All  
All  
All  
All  
11.4  
12.6  
250  
1.5  
Vdc  
mVdc  
%Vout  
%Vout  
Output Line Regulation  
0.5  
Output Ripple and Noise – measured with 0.1µF ceramic capacitor in  
parallel with 10µF tantalum capacitor, at 25°C1  
Peak-to-peak (20MHz Bandwidth)  
All  
180  
mV p-p  
Dynamic Load Response – 50% to 75% load transient, 0.1A/µs slew  
rate  
Output voltage deviation  
All  
5%  
%
Settling Time  
All  
500  
µs  
All versions except  
CLP0212FPEXZ02A  
Output Current  
0
0
16.7  
8.34  
Adc  
Output Current  
CLP0212FPEXZ02A  
All  
Adc  
Output Current Limit Inception  
115  
% IO,max  
1 Output ripple is 300mV p-p maximum at -40°C. To reduce further, additional external capacitance needed.  
October 11, 2013 ©2012 General Electric Corporation. All rights reserved.  
Page 2  
 
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Electrical Specifications (cont.)  
Parameter  
Device  
Min  
Typ  
Max  
Unit  
Maximum Output Capacitance  
All  
5000  
µF  
CLP0212FPXX5Z01A  
CLP0212FPEX5Z01A  
Standby Output Voltage  
5
Vdc  
CLP0212FPXX3Z01A  
All  
3.3  
Vdc  
Adc  
%
Standby Output Current  
Efficiency: VIN = 230Vac, 20% load  
50% load  
0.25  
All except ..Z02A  
All except ..Z02A  
All except ..Z02A  
All except ..Z02A  
All except ..Z02A  
All except ..Z02A  
86.8  
91.1  
89.5  
89.2  
90.3  
87.1  
%
100% load  
%
VIN = 115Vac, 20% load  
50% load  
%
%
100% load  
%
Holdup Time – VIN = 115Vac, 100% load2  
All except ..Z02A  
CLP0212FPEXZ02A  
10  
45  
ms  
ms  
65W load for CLP0212FPEXZ02A  
VIN = 230Vac, 100% load  
65W load for CLP0212FPEXZ02A  
All except ..Z02A  
CLP0212FPEXZ02A  
10  
45  
Isolation Specifications  
Parameter  
Device  
Min  
Max  
Unit  
Isolation Voltage – Input to output  
3000  
1500  
50  
Vac  
Vac  
Vac  
All  
All  
All  
Input to safety ground  
Outputs to safety ground  
General Specifications  
Parameter  
Device  
Symbol  
Typ.  
Unit  
FIT  
1,011.9  
109/Hours  
Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case  
3 (VIN=230Vac, Io = 16.7A, TA = 40ºC, airflow 200LFM, 90% confidence)  
All  
MTBF  
988,276  
Hours  
185  
6.5  
g
oz.  
Weight  
All  
Feature Specifications  
Parameter  
Device  
Min  
Typ  
Max  
Unit  
On/Off Signal Interface – signal referenced to GND  
Logic Low (Power Supply ON)  
Input Low Current  
All  
All  
7
1
mA  
V
Input Low Voltage  
Logic High (Power Supply OFF)  
Input High Current  
All  
All  
All  
All  
All  
All  
All  
All  
600  
5.5  
50  
µA  
V
Input Voltage  
Delay from ON/OFF being enabled to start of output voltage rise  
Output Voltage Rise Time (from 10 to 90% of final value)  
Delay from Input being applied to standby output being in regulation  
Delay from Input being applied to all outputs being in regulation  
Output Holdup time (from loss of AC to output being out of regulation)  
Output Overvoltage Protection (for main output currents above 0.1A)  
ms  
ms  
ms  
ms  
ms  
Vdc  
5
12  
30  
10  
13.8  
18  
2
Holdup time is reduced at cold temperatures  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 3  
 
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Feature Specifications (cont.)  
Parameter  
Device  
Min  
Typ  
Max  
Unit  
Input Undervoltage lockout3  
Turn-on Threshold (100% load)  
Turn-off Threshold (100% load)  
DC OK – open collector, High when output available  
Sink Current  
All  
All  
86  
82  
Vac  
Vac  
All  
All  
4
mA  
V
Maximum Collector Voltage  
12  
Environmental Specifications  
Parameter  
Device  
All  
Specification  
Conducted Emissions  
Input Harmonics  
CISPR22 (EN55022) Class A with 3dB margin  
EN61000-3-2  
All  
ESD  
All  
IEC 61000-4-2, Level 3  
Radiated Immunity  
Electrical Fast Transient Common Mode  
Surge Immunity  
All  
IEC 61000-4-3, Level 2*  
IEC 61000-4-4, Level 3  
All  
All  
IEC 61000-4-5, Level 3  
Conducted RF Immunity  
Voltage Dips  
All  
IEC 61000-4-6, Level 3  
All  
EN61000 4.11, Level 3, Class B, C  
Shock and Vibration  
Operating Shock  
All  
All  
Three shocks, 15G peak, 11ms sine wave, two axes  
Three shocks, 50G peak, 11ms sine wave, two axes  
Non-Operating Shock  
5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles  
9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles  
Operating and Non-Operating Vibration  
All  
* Radiated immunity is met when the power supply is tested in a suitable enclosure.  
3 The undervoltage lockout thresholds vary with output load current level – decreasing as the load goes down  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 4  
 
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Characteristic Curves  
The following figures provide typical characteristics for CLP0212 power supply  
20  
15  
10  
5
94  
92  
90  
88  
86  
84  
82  
80  
2m/s  
(400LFM)  
Vin=115VAC  
Vin=230VAC  
0.5m/s  
(100LFM)  
1m/s  
200LFM  
(
)
NC  
0
0
2
4
6
8
10  
12  
14  
16  
18  
30  
35  
40  
45  
50  
55  
60  
65  
70  
OUTPUT LOAD %  
AMBIENT TEMPERATURE, TA OC  
Figure 2. Derating Output Current versus Ambient  
Temperature and Airflow. Data shown for 115VAC in, at  
Figure 1. Power Supply Efficiency versus Output Current.  
230VAC in derating is the same or better. For derating at  
other input voltages, consult the GE Technical  
representative.  
TIME, t (10ms/div)  
TIME, t (5ms /div)  
Figure 3. Typical output ripple and noise (VIN = 230Vac,  
100% load ).  
Figure 4. Transient Response to Dynamic Load Change from  
50% to 100% at Vin = 230Vac.  
TIME, t (10ms/div)  
TIME, t (10ms/div)  
Figure 5. Typical Start-up (VIN = 115Vac).  
Figure 6. Typical Start-up (VIN = 230Vac)  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 5  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Characteristic Curves (cont.)  
The following figures provide typical characteristics for CLP0212 power supply  
TIME, t (10ms/div)  
TIME, t (10ms/div)  
Figure 7. Typical Hold-up waveforms (VIN = 115V, 100%  
load).  
Figure 8. Typical Hold-up waveforms (VIN = 230V, 100% load).  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 6  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Output Voltage Adjustment  
Safety Considerations  
The CLP0212 power supply is intended for inclusion in other  
equipment and the installer must ensure that it is in  
compliance with all the requirements of the end application.  
This product is only for inclusion by professional installers  
within other equipment and must not be operated as a  
stand-alone product  
IEC60950, EN60950, with the following deviations: Nemko  
. The power supply meets Class 1,  
Potentiometer  
.
UL  
60950 (Recognized Component) C-UL (Canadian Approvalby  
UL).  
Feature Descriptions  
Fig. 10. Diagram showing location of the potentiometer  
used to adjust the power supply output voltage.  
Standby Power Supply  
A standby output in the CLP0212 power supply of either 3.3  
or 5V, comes on when AC input in the operating range is  
applied. In the Z02A and Z03A versions of the power supply,  
the standby output is not accessible.  
The output voltage can be adjusted between 11.4V and 12.6V  
using a potentiometer on the power supply. See Fig. 10 for a  
diagram showing location of the potentiometer.  
Remote Sense  
Remote On/Off  
The power supply has both positive and negative remote  
sense connections that can be connected to the positive  
and negative rails of the main output near the load. Care  
should be taken in routing the sense lines to ensure that  
noise is not picked up or that additional filtering elements  
that affect the stability of the power supply are not used.  
The power supply will operate without the remote sense  
connections being made, however if remote sense near the  
load is not used it is recommended that the remote sense  
lines be connected directly to the main output terminals.  
All versions of the CLP0212 power supply except the Z02A  
and Z03A versions feature a TTL-compatible On/Off control  
input. The power supply turns ON when the On/Off input  
goes low, and turns OFF when the input goes high. Note  
that if the On/Off pin is left unconnected, the power supply  
main output remains off.  
Figure 9 shows the circuit configuration for using the On/Off  
pin. Either a suitable semiconductor device such as a BJT or  
FET or a mechanical switch can be used to turn the power  
supply On and Off. The switch must be capable of handling  
the On/Off pin current which may be up to 6mA when  
closed. The switch On voltage drop must also be sufficiently  
small so that the photo diode inside the power supply is  
turned ON when the external switch is ON.  
Overcurrent Protection  
To provide protection in a fault condition (output overload), the  
power supply is equipped with internal current-limiting  
circuitry and can endure current limiting continuously. At the  
point of current-limit inception, the unit enters hiccup mode.  
The power supply operates normally once the output current is  
brought back into its specified range.  
Note that the standby output voltage could be either 3.3V or  
5V depending on the CLP0212 power supply variant  
selected. If no On/Off control is desired, the On/Off pin can  
be externally connected to the COM pin and the power  
supply will automatically turn ON when AC input is within  
range.  
Overvoltage Protection  
Overvoltage protection is a feature of the CLP0212 power  
supply that protects both the load and the power supply from  
an output overvoltage condition. When an overvoltage occurs,  
the power supply shuts down and goes into hiccup mode until  
the overvoltage condition is removed. It is not necessary to  
recycle the input to restart the power supply when this  
protection is activated.  
CLP POWER SUPPLY  
STANDBY OUTPUT  
3.65K  
1K  
Overtemperature Protection  
The CLP0212 also features overtemperature protection in  
order to provide additional protection in a fault condition. The  
power supply is equipped with a thermal shutdown circuit  
which detects excessive internal temperatures and shuts the  
unit down. Once the power supply goes into overtemperature  
shutdown, it will cool before attempting to restart. The  
overtemperature protection circuit will typically activate when  
the unit is operated at 200W output with an ambient  
temperature of 60ºC and 1m/s (200LFM) airflow.  
ON/OFF  
SWITCH  
COM  
Fig. 9. Schematic showing ON/OFF circuitry.  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 7  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout limit,  
power supply operation is disabled. The power supply will  
begin to operate at an input voltage above the undervoltage  
lockout turn-on threshold. Note that the undervoltage lockout  
limits are load dependent and the power supply turns ON and  
can operate at much lower input voltage levels when at light  
or no load.  
DC OK  
The CLP0212 provides a DC OK signal that indicates when  
the output has come up and is in regulation. This is an open-  
collector type signal that goes high when the output is  
available and within regulation.  
Fig. 11. Preferred airflow direction for cooling.  
Operation In a Sealed Enclosure  
Power Good LED  
A green LED (located next to HDR3) illuminates when the main  
output voltage is above 10V.  
The CLP0212 power supply can also be operated in a sealed  
enclosure provided proper means for removing heat from the  
power supply are used. Figure 12 shows an arrangement  
where a thermally conductive pad is used to transfer heat  
from the bottom of the power supply into the enclosure. Under  
such conditions, the power supply is capable of reduced power  
operation as shown in Table 1.  
Paralleling/Load Share  
This power supply can be paralleled to provide larger load  
currents than can be delivered from a single power supply. Up  
to four power supplies may be paralleled. Paralleling is  
accomplished by connecting the Current Share signals of  
multiple power supplies together. At load current levels above  
20%, the output currents of multiple power supplies will be  
within ±5% of the full load value.  
If remote sense is used when paralleling is employed, the  
remote sense connection points should be common to both  
power supplies.  
For applications where redundancy among paralleled power  
supplies is desired, ORing diodes or other active ORing circuitry  
needs to be connected in series with each output.  
Enclosure Wall  
Thermal Considerations  
Thermally Conductive Pad  
The power supply can be operated in a variety of thermal  
environments; however sufficient cooling should be provided  
to ensure reliable operation.  
Fig. 12. Example arrangement of the CLP0212 for sealed  
enclosure applications.  
Considerations include ambient temperature, airflow, power  
supply dissipation and the need for increased reliability. A  
reduction in the operating temperature of the power supply  
will result in increased reliability. The thermal data presented  
here is based on measurements taken in a wind tunnel.  
Table 1. Output Power Capability when the CLP0212 is  
operated in a sealed enclosure with thermal pad for  
conduction cooling.  
Ambient Temperature (ºC)  
Max. Output Power (W)  
25  
40  
55  
170  
150  
110  
Heat Transfer via Convection  
Increased airflow through the power supply enhances the heat  
transfer via convection. Figure 11 shows the preferred airflow  
direction. Contact your GE Energy technical representative for  
derating information in other airflow directions.  
.
Note: Under Natural Convection cooling conditions, the  
maximum load is restricted to 100W as OTP will be triggered  
at higher loads.  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 8  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
EMI performance  
All CLP0212 power supplies are specified to meet conducted Class A EMI requirements per CISPR 22 (EN55022) with at least 3dB of  
margin. Results of tests conducted without any external filtering are shown below. These indicate 10dB or better of margin over  
the Class A limits.  
CLP0212FPXX5Z01A (120VAC in, 12V @ 180W out, Negative of Output Grounded)  
CLP0212FPXX5Z01A (208VAC in, 12V @ 180W out, Negative of Output Grounded)  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 9  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
CLP0212FPEX5Z03A (120VAC in, 12V @ 180W out, Negative of Output Grounded)  
CLP0212FPEX5Z03A (208VAC in, 12V @ 180W out, Negative of Output Grounded)  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 10  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Mechanical Outline (all except CLP0212…Z02A & CLP0212…Z03A versions)  
Dimensions are in millimeters.  
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]  
x.xx mm ± 0.25mm  
TOP VIEW  
SIDE VIEW  
3D-VIEW  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 11  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Mechanical Outline - CLP0212FPEXZ02A  
Dimensions are in millimeters.  
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]  
x.xx mm ± 0.25mm  
TOP VIEW  
SIDE VIEW  
3D-VIEW  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 12  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Mechanical Outline - CLP0212FPEX5Z03A  
Dimensions are in millimeters.  
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]  
x.xx mm ± 0.25mm  
TOP VIEW  
SIDE VIEW  
3D-VIEW  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 13  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Connector Information  
Connector  
Connector on Power Supply  
5-1376382-1 from Tyco or equivalent  
39-28-1043 from Molex or equivalent  
53047-0810 from Molex or equivalent  
Mating Connector  
AC Input Connector (HDR1)  
DC Output Connector (HDR2)  
Signal Connector (HDR3)  
1376388-1 from Tyco or equivalent  
39-01-2040 from Molex or equivalent  
51021-0800 from Molex or equivalent  
Pinout Information  
AC Input Connector (HDR1)  
DC Input Connector (HDR2)  
Signal Connector (HDR3)  
Pin 1  
Pin 2  
Line  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
VO  
Pin 1  
Current Share  
Neutral  
VO  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
+S (Remote Sense +)  
-S (Remote Sense -)  
Remote On/Off  
RTN  
RTN  
DC-OK (Output OK)  
COM (Output Return)  
COM (Output Return)  
Standby Output  
Note: Signal Connector HD3 is not present in the Z02A and Z03A versions.  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Page 14  
Preliminary Data Sheet  
GE  
CLP0212 Open Frame Power Supply  
90 - 264Vac input; 12Vdc output; 200W Output Power  
Ordering Information  
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.  
Table 2. Device Codes  
Input  
Output  
Output  
Standby  
Supply  
Temperature  
Range  
Device Code  
On/Off Control  
Comcode  
Voltage Range Voltage Current  
CLP0212FPXX5Z01A  
CLP0212FPXX3Z01A  
CLP0212FPEX5Z01A  
CLP0212FPEXZ02A  
CLP0212FPEX5Z03A  
CLP0212FPXX5Z03A  
90 – 264Vac  
90 – 264Vac  
90 – 264Vac  
90 – 264Vac  
90 – 264Vac  
90 – 264Vac  
12.0Vdc  
12.0Vdc  
12.0Vdc  
12.0Vdc  
12.0Vdc  
12.0Vdc  
16.7A  
16.7A  
16.7A  
8.34A  
16.7A  
16.7A  
Negative Logic  
Negative Logic  
Negative Logic  
Absent  
5V@0.25A  
3.3V@0.25A  
5V@0.25A  
-25 to 70ºC  
-25 to 70ºC  
-40 to 70ºC  
-40 to 70ºC  
-40 to 70ºC  
-25 to 70ºC  
150032000  
150032001  
150032002  
150032003  
150032004  
150032005  
Not accessible  
Not accessible  
Not accessible  
Absent  
Absent  
Contact Us  
For more information, call us at  
USA/Canada:  
+1 888 546 3243, or +1 972 244 9288  
Asia-Pacific:  
+86.021.54279977*808  
Europe, Middle-East and Africa:  
+49.89.878067-280  
India:  
+91.80.28411633  
www.gecriticalpower.com  
October 11, 2013  
©2012 General Electric Corporation. All rights reserved.  
Version 1.26  

相关型号:

CLP0212FPXX5Z03A

90 - 264Vac input; 12Vdc output; 200W Output Power
LINEAGEPOWER

CLP04P040L28

Super Capacitors To Improve Power Performance.
ETC

CLP0608

Pulse Transformer
SUMIDA

CLP0917

LAN pulse transformer for 1000Base
SUMIDA

CLP100-0010

BAR CODE SCANNERS
SICK

CLP100-2110

BAR CODE SCANNERS
SICK

CLP1000AA200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER

CLP1000AB200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER

CLP1000AC200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER

CLP1000AD200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER

CLP1000AE200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER

CLP1000AF200

ALUMINIUM ELECTROLYTIC STANDARD TEMP. SNAP-IN CLP
DUBILIER