M9380A-F03 [KEYSIGHT]

M9380A PXIe CW Source;
M9380A-F03
型号: M9380A-F03
厂家: Keysight Technologies    Keysight Technologies
描述:

M9380A PXIe CW Source

文件: 总17页 (文件大小:2651K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Keysight Technologies  
M9380A PXIe CW Source  
1 MHz to 3 GHz or 6 GHz  
Data Sheet  
Overview  
– Aerospace and defense  
– Interference injection  
– LO substitution  
Introduction  
With high-power levels and accurate measurements, the M9380A CW  
source provides the Keysight Technologies, Inc. quality and performance  
in the PXI form factor—a trusted Keysight product with global services and  
support, fast repair and a wide scope of calibration utilities.  
– Wireless component test  
Product description  
The M9380A PXIe CW source is a compact modular solution that  
provides frequency coverage from 1 MHz to 3 or 6 GHz. A typical M9380A  
configuration includes three individual PXIe modules—M9310A source  
output, M9301A synthesizer and the M9300A frequency reference—  
designed for fast data interfaces and high-speed automated test systems.  
Instrument control is provided through a soft front panel and programmatic  
interfaces tuned to your application development environment of choice.  
Product features  
– Frequency coverage from 1 MHz to 3 or 6 GHz  
– Output power of +18 dBm across the frequency range  
– Output power level of +19 dBm from 1 MHz to 5 GHz  
– Better than ±0.4 dB absolute amplitude accuracy  
– License key upgraded frequency range and output power  
– One day startup assistance  
– Chassis slot compatibility: PXIe slot  
Uncompromising values  
– Keeps costs manageable—purchase what you need today and  
easily upgrade later using license-key upgrades without returning your  
modules to Keysight.  
Reduces development time and simplifies integration into existing test  
environments with multiple drivers and programmatic interfaces.  
Reduces startup time with Keysight IO libraries easy configuration,  
one-step software install, and integrated instrument level CW source  
soft front panel.  
Figure 1. M9380A PXIe CW source with three  
modules consisting of the M9310A PXIe source  
output, M9301A PXIe synthesizer, and M9300A  
PXIe frequency reference.  
Fast repair turnaround time with calibrated core exchange strategy.  
Applications  
03 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics  
Block diagram  
(+13 dBm sine  
M9301A PXIe Synthesizer  
M9300A PXIe Frequency Reference  
all 1001M0H0z OMutsH) z  
Out 1  
3 dB  
RF/LO Out 1A  
External Trigger Trig 2 (front)  
to PXI Backplane  
100 MHz PLL  
100 MHz  
Out 2  
100 MHz  
Out 3  
3 dB  
3 dB  
3 dB  
3 GHz to 6 GHz  
RF/LO Out 1B  
RF/LO Out 2A  
RF/LO Out 2B  
Banded  
Switched  
Filter  
Divide  
by 1-2-4-8  
100 MHz  
(1 to 110 MHz)  
Ref In  
Bank  
PLL  
100 MHz  
Out 4  
10 MHz OCXO  
TIMEBASE  
850 MHz  
Divide  
by 1 or 2  
100 MHz  
Out 5  
(RF Outputs: 187.5 MHz to 6 GHz)  
(-10 dBm to +10 dBm)  
3 dB  
100 MHz In (+13 dBm Typical)  
10 MHz  
10 MHz Out  
Divide  
by 10  
3 dB  
100 MHz  
10 MHz  
OXCO Out  
Out  
(10 MHz, +10 dBm  
to 16 dBm, sine)  
(+13 dBm  
Typical)  
M9310A PXIe Source Output  
RF  
LO  
IF  
RF In  
ALC and  
Power  
Control  
Pulse  
Modulator  
(1 MHz to 6 GHz)  
(-5 dBm to +5 dBm)  
Pulse Mod Trigger  
Trig 1 (Front Panel)  
ALC Hold Trigger  
PXI Backplane  
(-130 dBm to +19 dBm, 1 MHz to 5 GHz)  
(-130 dBm to +18 dBm, >5 GHz to 6 GHz)  
ALC  
Coupler  
Log Amp  
RF Out  
Limiter  
6 GHz  
100 MHz In  
(+10 dBm typical)  
100 MHz Out  
(+10 dBm typical)  
Figure 2. M9380A PXIe CW source with three modules consisting of the M9300A PXIe frequency reference, M9301A PXIe synthesizer and M9310A PXIe source output.  
04 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics  
Definitions for specifications  
Temperatures referred to in this document are defined as follows:  
Full temperature range = Individual module temperature of ≤ 75 °C, as reported by  
the module, and environment temperature of 0 to 55 °C.  
Controlled temperature range = Individual module temperature of ≤ 55 °C, as  
reported by the module, and environment temperature of 20 to 30 °C.  
Specifications describe the warranted performance of calibrated instruments. Data  
represented in this document are specifications unless otherwise noted under the  
following conditions.  
– Calibrated instruments have been stored for a minimum of 2 hours within the full  
temperature range  
– 45 minute warm-up time  
– Calibration cycle maintained  
– When used with Keysight M9300A frequency reference  
– When used with Keysight interconnection cables  
Characteristics describe product performance that is useful in the application of the  
product. Characteristics are often referred to as Typical or Nominal values and are itali-  
cized.  
– Typical describes characteristic performance, which 80% of instruments will meet  
when operated within the controlled temperature range.  
– Nominal describes representative performance that is useful in the application of the  
product when operated within the controlled temperature range.  
Recommended best practices in use  
Use slot blockers and EMC filler panels in empty module slots to ensure proper  
operating temperatures.  
– Keysight chassis and slot blockers optimize module temperature performance and  
reliability of test.  
At environment temperatures above 45 °C, chassis fan should be set to high.  
Additional information  
– All graphs contain measured data from one unit and is representative of product  
performance at the controlled temperature range unless otherwise noted.  
The specifications contained in this document are subject to change.  
05 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Frequency  
Frequency range  
Option F03  
1 MHz to 3 GHz  
1 MHz to 6 GHz  
0.01 Hz  
Option F06  
Resolution  
Frequency switching speed 1  
≤ 5 ms, nominal  
Frequency reference (M9300A PXIe frequency reference module)  
Reference outputs  
100 MHz Out (Out 1 through Out 5)  
Amplitude  
Connectors  
Impedance  
10 MHz Out  
Amplitude  
Connectors  
Impedance  
OCXO Out  
Amplitude  
Connectors  
Impedance  
≥ 10 dBm  
13 dBm, typical  
5 SMB snap-on  
50 Ω, nominal  
9.5 dBm, nominal  
1 SMB snap-on  
50 Ω, nominal  
11.5 dBm, nominal  
1 SMB snap-on  
50 Ω, nominal  
1. Mean time from IVI command to carrier frequency settled within 1 ppm or 1 kHz whichever is greater and amplitude settled within 0.2 dB (at the  
controlled temperature range) or within 0.5 dB (at the full temperature range). If the ALC is off, the settle limit is 0.5 dB above +10 dBm, (at the  
controlled temperature range). Simulataneous carrier frequency and amplitude switching.  
06 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Frequency (continued)  
Frequency accuracy  
Same as accuracy of internal time base or external reference input  
Internal timebase  
Accuracy  
± (time since last adjustment x aging rate)  
± temperature effects  
± calibration accuracy  
Frequency stability  
Aging rate  
Daily  
< ±0.5 ppb/day, after 72 hour warm-up  
< ±0.1 ppm/year, after 72 hours warm-up  
< ±0.6 ppm/10yrs, after 72 hours warm-up  
±5 x 10 -8  
Yearly  
Total 10 years  
Achievable initial calibration accuracy (at time of shipment)  
Temperature effects  
20 to 30 °C  
< ±10 ppb  
< ±50 ppb  
Full temperature range  
Warm up  
5 minutes over +20 to +30 °C, with respect to 1 hour  
< ±0.1 ppm  
15 minutes over +20 to +30 °C, with respect to 1 hour  
< ±0.01 ppm  
External reference input  
Frequency  
1 MHz to 110 MHz, sine wave  
±1 ppm, nominal  
Lock range  
Amplitude  
0 to 10 dBm, nominal  
1 SMB snap-on  
Connector  
Impedance  
50 Ω, nominal  
07 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Amplitude  
Output parameters  
Settable range  
Standard  
Option 1EA  
+10.7 to -130 dBm  
+20 to -130 dBm  
Resolution  
ALC on 1  
0.02 dB, nominal  
0.3 dB, nominal  
ALC off  
Maximum output power  
Frequency  
Standard  
+10 dBm  
+10 dBm  
Option 1EA  
+19 dBm  
+18 dBm  
1 MHz to 5 GHz  
> 5 to 6 GHz  
Absolute level accuracy in CW mode [ALC on] 2  
< Max power to -20 dBm  
< -20 to -110 dBm  
< -110 to -120 dBm  
<-120 to -130 dBm  
Frequency  
1 MHz to 3 GHz  
±0.4 dB  
±0.5 dB  
±0.7 dB  
±0.8 dB, nominal  
±0.15 dB, typical  
±0.15 dB, typical  
±0.25 dB, typical  
> 3 to 6 GHz  
±0.5 dB  
±0.6 dB  
±1.0 dB  
±0.8 dB, nominal  
±0.15 dB, typical  
±0.25 dB, typical  
±0.5 dB, typical  
1. Settable to 0.01 dB.  
2. Specifications apply at the controlled temperature range. For temperatures outside this range, absolute level accuracy degrades by ± 0.02 dB/°C.  
-120 dBm Output Power Normalized Response  
1
0.75  
0.5  
0.25  
0
-0.25  
-0.5  
-0.75  
-1  
0
1
2
3
4
5
6
Frequency (GHz)  
Figure 3. Output power normalized response at –120 dBm.  
08 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Amplitude (continued)  
Amplitude Repeatability +10 dBm ALC On  
0.05  
850 MHz  
0.04  
0.03  
0.02  
0.01  
0
1900 MHz  
2200 MHz  
3500 MHz  
5800 MHz  
-0.01  
-0.02  
-0.03  
-0.04  
-0.05  
0
20  
40  
60  
80  
100  
120  
Elapsed Time (minutes)  
Figure 4. Amplitude repeatability at various carrier frequencies. Repeatability measures the ability of the  
instrument to return to a given power setting after a random excursion to any other frequency and power setting.  
It should not be confused with absolute level accuracy.  
Relative Level Accuracy  
ALC On  
0.6  
0.85 GHz  
1.8 GHz  
2 GHz  
0.4  
2.2 GHz  
3.5 GHz  
5.8 GHz  
0.2  
0
-0.2  
-0.4  
-0.6  
-120  
-100  
-80  
-60  
-40  
-20  
0
20  
Power Level (dBm)  
Figure 5. Relative level accuracy at various carrier frequencies.  
09 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Amplitude (continued)  
VSWR  
1 MHz to 6 GHz  
< 1.5:1, nominal  
Maximum reverse power  
1 MHz to 6 GHz  
1 W, nominal  
Max DC voltage  
25 VDC, nominal  
VSWR  
1.50  
1.45  
1.40  
1.35  
1.30  
1.25  
1.20  
1.15  
1.10  
1.05  
1.00  
0 dB An  
30 dB An  
Bypass Path  
0
1
2
3
4
5
6
Frequency (GHz)  
Figure 6. Measured VSWR from 1 MHz to 6 GHz.  
10 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Spectral purity  
Phase noise at 20 kHz offset  
1 GHz  
2 GHz  
3 GHz  
6 GHz  
-122 dBc/Hz, typical  
-117 dBc/Hz, typical  
-112 dBc/Hz, typical  
-108 dBc/Hz, typical  
Single Sideband Phase Noise in CW Mode  
Normal Loop Bandwidth  
-20  
-30  
-40  
1GHz  
-50  
2GHz  
2.4GHz  
3GHz  
-60  
-70  
5.8GHz  
6GHz  
-80  
-90  
-100  
-110  
-120  
-130  
-140  
-150  
-160  
10 Hz  
100 Hz  
1 kHz  
10 kHz  
100 kHz  
1 MHz  
10 MHz  
Frequency Offset From Carrier  
Figure 7. Single sideband phase noise in normal loop bandwidth from 10 Hz to 10  
MHz, offset at 1, 2, 2.4, 3, 5.8, and 6 GHz.  
Single Sideband Phase Noise in CW Mode  
Narrow Loop Bandwidth  
-20  
-30  
-40  
1GHz  
-50  
2GHz  
-60  
-70  
2.4GHz  
3GHz  
5.8GHz  
6GHz  
-80  
-90  
-100  
-110  
-120  
-130  
-140  
-150  
-160  
10 Hz  
100 Hz  
1 kHz  
10 kHz  
100 kHz  
1 MHz  
10 MHz  
Frequency Offset From Carrier  
Figure 8. Single sideband phase noise in narrow loop bandwidth from 10 Hz to 10 MHz,  
offset at 1, 2, 2.4, 3, 5.8, and 6 GHz.  
11 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Spectral purity (continued)  
Broadband noise floor  
Range  
1 MHz to 6 GHz  
< -140 dBc/Hz, nominal, at +10 dBm output power level  
Harmonics  
Range  
≤ 0 dBm  
< -43 dBc  
< -29 dBc  
< -35 dBc  
≤ +10 dBm  
1 MHz to < 400 MHz  
400 MHz to 1.5 GHz  
> 1.5 GHz to 3 GHz  
-46 dBc, typical  
-31 dBc, typical  
-39 dBc, typical  
< -35 dBc  
< -27 dBc  
< -30 dBc  
-37 dBc, typical  
-29 dBc, typical  
-33 dBc, typical  
Nonharmonics 1  
Nonharmonic miscellaneous spurious 2  
Nonharmonic HET band mixing spurs (0 dBm)  
Nonharmonic Frac-N  
< -70 dBc, nominal  
< -67 dBc, nominal  
< -66 dBc, nominal  
Subharmonics  
1 MHz to 6 GHz  
none  
Analog modulation  
Pulse parameters  
Pulse on/off ratio 1 MHz to 400 MHz  
Pulse on/off ratio > 400 MHz to 6 GHz  
Pulse rise/fall time  
> 85 dB, typical  
> 95 dB, typical  
< 10 ns, nominal  
System requirements  
Topic  
Windows 7 requirements  
Operating systems  
Processor speed  
Windows 7 (32-bit and 64-bit)  
1 GHz 32-bit (x86), 1 GHz 64-bit (x64)  
(no support for Itanium 64)  
Available memory  
4 GB minimum  
8 GB or greater recommended  
Available  
disk space 3  
1.5 GB available hard disk space, includes:  
– 1 GB available for Microsoft .NET framework 3.5 SP1 4  
– 100 MB for Keysight IO libraries suite  
Video  
Support for DirectX 9 graphics with 128 MB graphics memory recommended  
(Super VGA graphics is supported)  
Browser  
Microsoft Internet Explorer 7.0 or greater  
Version 16.3.16603.3 or later  
Keysight IO libraries  
1. Non-harmonics include mixing spurs for frequencies below 400 MHz, synthesizer spurs, and other miscellaneous chassis and power supply products, for  
offsets >10 kHz.  
2. With a Keysight M9036A embedded controller.  
3. Because of the installation procedure, less memory may be required for operation than is required for installation.  
4. NET framework runtime components are installed by default with Windows Windows 7. Therefore, you may not need this amount of available disk space.  
12 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Technical Specifications and Characteristics (continued)  
Environmental and physical specifications  
Temperature  
Humidity 1  
Operating  
Non-operating (storage)  
0 to 55 °C  
-40 to +70 °C  
Type tested at 95%, +40 °C  
(non-condensing)  
Altitude  
Connectors  
EMC  
Up to 15,000 feet (4,572 meters)  
SMA female  
RF OUT  
Complies with European EMC Directive  
2004/108/EC  
– IEC/EN 61326-2-1  
– CISPR Pub 11 Group 1, class A  
– AS/NZS CISPR 11  
– ICES/NMB-001  
This ISM device complies with Canadian ICES-001.  
Cet appareil ISM est conforme a la norme NMB-001 du Canada.  
Warm-up time  
45 minutes  
Size  
M9300A  
M9301A  
M9310A  
1 PXIe slot  
1 PXIe slot  
1 PXIe slot  
Dimensions  
Module  
M9300A  
M9301A  
M9310A  
Length  
Width  
22 mm  
22 mm  
22 mm  
Height  
210 mm  
210 mm  
210 mm  
130 mm  
130 mm  
130 mm  
Weight  
M9300A  
M9301A  
M9310A  
0.551 kg (1.215 lbs)  
0.535 kg (1.179 lbs)  
0.551 kg (1.215 lbs)  
Power drawn from chassis  
M9300A  
M9301A  
M9310A  
≤ 18 W  
≤ 25 W  
≤ 28 W  
1. Samples of this product have been type tested in accordance with the Keysight environmental test manual and verified to be robust against the  
environmental stresses of storage, transportation and end-use--those stresses include but are not limited to temperature, humidity, shock, vibration,  
altitude and power-line conditions. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3.  
13 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Software  
Instrument connection software  
Keysight IO library  
The IO suite offers a single entry point for connection to the most  
Free software download at  
common instruments including AXIe, PXI, GPIB, USB, Ethernet/LAN,  
RS-232, and VXI test instruments from Keysight and other vendors.  
It automatically discovers interfaces, chassis, and instruments. The  
graphical user interface allows you to search for, verify and update  
IVI instrument and soft front panel drivers for modular and traditional  
instruments. The IO suite safely installs in side-by-side mode with NI  
I/O software.  
www.keysight.com/find/iosuite  
Module setup and usage  
Keysight soft front  
panel  
The PXI module includes a soft front panel (SFP), a software-based  
graphical user interface (GUI) which enables the instrument’s  
capabilities from your PC.  
Included on CD-ROM shipped with  
module or online  
Programming  
Driver  
Development environments  
lVI-COM  
IVI-C  
Visual Studio (VB.NET, C#, C/C++), VEE  
LabVIEW, LabWindows/CVI, MATLAB  
Included on CD-ROM shipped with  
module or online  
LabVIEW  
MATLAB  
Programming assitance  
Command expert  
Assists in finding the right instrument commands and setting correct  
parameters. A simple interface includes documentation, examples,  
syntax checking, command execution and debug tools to build  
sequences for integration in Excel, MATLAB, Visual Studio, LabVIEW,  
VEE, SystemVue.  
Free software download at  
www.keysight.com/find/  
commandexpert  
Programming  
examples  
Each module includes programming examples for Visual Studio.net,  
LabVIEW, MATLAB, LabWindows, and Keysight VEE Pro.  
Included on CD-ROM shipped with  
module or online at  
www.keysight.com/find/m9380a  
14 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Setup and Calibration Services  
Assistance  
One day startup  
assistance  
Gain access to a technical expert who will help you get started quickly with the  
Included in base configuration  
Included in base configuration  
M9380A CW source and its powerful software tools. The flexible instruction  
format is designed to get you to your first measurements and familiarize you with  
ways to adapt the equipment to a specific application.  
Calibration and traceability  
Factory calibration  
The M9380A CW source ships factory calibrated with an ISO-9002,  
NIST-traceable calibration certificate.  
Calibration cycle  
Calibration sites  
A one year calibration cycle is recommended.  
At Keysight worldwide service centers  
On-site by Keysight  
More information visit  
www.keysight.com/find/infoline  
By self-maintainers  
N7800A  
The M9380A CW source is supported by Keysight’s Calibration and adjustment  
Licensed software. For more information,  
Calibration and  
adjustment software  
software. This is the same software used at Keysight service centers to automate visit  
calibration. The software offers compliance tests for ISO 17025:2005,  
ANSI/NCSL Z540.3-2006, and measurement uncertainty per ISO Guide to  
Expression of Measurement Uncertainty.  
www.keysight.com/find/calibrationsoftware  
Keysight calibration  
status utility  
The Keysight calibration status utility helps ensure your M9380A is calibrated by Included in base configuration  
managing the calibration interval and providing messages regarding instrument  
and module calibration status.  
15 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Support  
Support  
Core exchange  
program  
Keysight’s replacement core exchange program allows fast and easy module repairs. A replacement  
core assembly is a fully functioning pre-calibrated module replacement that is updated with the  
defective module serial number, allowing the replacement module to retain the original serial number.  
For qualified  
self-maintainers in  
US only  
Self-test utility  
A self-test utility runs a set of internal tests which verifies the health of the modules and reports their  
status.  
Included in base  
configuration  
16 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheett  
Configuration and Ordering Information  
Ordering information  
Software information  
Model  
M9380A  
Description  
Supported operating  
systems  
Microsoft Windows 7  
(32/64-bit)  
PXIe CW source: 1 MHz to 3 or 6 GHz  
Includes:  
Standard compliant  
IVI-COM, IVI-C, LabVIEW, MATLAB  
drivers  
M9301A PXIe Synthesizer  
M9310A PXIe Source Output  
One day startup assistance  
Module interconnect cables  
Software, example programs and product  
information on CD  
Supported application  
development  
environments (ADE)  
VisualStudio (VB.NET, C#, C/C++), VEE,  
LabVIEW, LabWindows/CVI, MATLAB  
Keysight IO libraries  
(version 16.3 or newer)  
Includes: VISA Libraries, Keysight  
Connection Expert, IO Monitor  
Base configuration  
Keysight Command expert Instrument control for SCPI or IVI-COM  
M9380A-F03  
Frequency range: 1 MHz to 3 GHz  
drivers  
M9380A-300  
Required for  
warranted  
PXIe frequency reference: 10 and 100 MHz  
Adds M9300A PXIe frequency reference: 10  
and 100 MHz (M9300A module can support  
multiple M9380A modular instruments)  
Accessories  
specifications  
Model  
Description  
Configurable options  
Y1212A  
Y1213A  
Y1214A  
Y1215A  
Slot blocker kit: 5 modules  
PXI EMC filler panel kit: 5 slots  
Air inlet kit: M9018A 18-slot chassis  
Rack mount kit for M9018A 18-slot chassis  
Frequency range  
M9380A-F03  
1 MHz to 3 GHz  
1 MHz to 6 GHz  
M9380A-F06  
Power  
Related products  
M9380A-1EA  
Calibration  
M9380A-UK6  
High output power  
Model  
Description  
Commercial calibration certificate with test  
data for M9380A (M9301A, M9310A)  
M9021A  
M9045B  
Y1200B  
M9048A  
Y1202A  
M9381A  
M9300A  
PCIe cable interface  
PCIe ExpressCard adaptor for laptop connectivity  
PCIe cable for laptop connectivity  
PCIe desktop adaptor for desktop connectivity  
PCIe Cable for desktop connectivity  
PXIe Vector Signal Generator  
PXIe Frequency Reference  
M9300A-UK6  
Commercial calibration certificate with test  
data for M9300A (module only)  
Related products in recommended configuration  
M9037A  
PXIe embedded controller  
18-slot PXIe chassis  
M9018A  
Recommended configuration  
Advantage services:  
Calibration  
Keysight Advantage Services is committed to your success throughout  
your equipment’s lifetime  
N7800A  
Calibration & adjustment software  
17 | Keysight | M9380A PXIe CW Source 1 MHz to 3 GHz or 6 GHz - Data Sheet  
For more information on Keysight  
Evolving Since 1939  
Our unique combination of hardware, software, services, and people can help you  
reach your next breakthrough. We are unlocking the future of technology.  
From Hewlett-Packard to Agilent to Keysight.  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
myKeysight  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
Other AP Countries  
www.keysight.com/find/emt_product_registration  
Register your products to get up-to-date product information and  
find warranty information.  
Europe & Middle East  
Austria  
Belgium  
Finland  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
Keysight Services  
www.keysight.com/find/service  
Keysight Services can help from acquisition to renewal across your  
instrument’s lifecycle. Our comprehensive service offerings—one-  
stop calibration, repair, asset management, technology refresh,  
consulting, training and more—helps you improve product quality  
and lower costs.  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure  
your instruments are operating to specification, so you can rely on  
accurate measurements.  
Spain  
Sweden  
Switzerland  
Opt. 2 (FR)  
Opt. 3 (IT)  
0800 0260637  
Keysight Channel Partners  
www.keysight.com/find/channelpartners  
United Kingdom  
Get the best of both worlds: Keysight’s measurement expertise and  
product breadth, combined with channel partner convenience.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-9-7-17)  
www.keysight.com/find/m9380a  
www.keysight.com/find/modular  
DEꢀRA Certiꢁied  
ISO9001 ꢂuꢃlitꢄ Mꢃnꢃgement Sꢄstem  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
This information is subject to change without notice.  
© Keysight Technologies, 2017  
Published in USA, December 1, 2017  
5991-0283EN  
www.keysight.com  

相关型号:

M9380A-F06

M9380A PXIe CW Source
KEYSIGHT

M9380A-UK6

M9380A PXIe CW Source
KEYSIGHT

M9380A_18

M9380A PXIe CW Source
KEYSIGHT

M9381A

M9381A PXIe Vector Signal Generator
KEYSIGHT

M9381A_17

M9381A PXIe Vector Signal Generator
KEYSIGHT

M9386-BN3T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-BN6T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-DS3T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-DS6T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-DW3T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-DW6T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR

M9386-MN3T

16Kbit, 8Kbit, 4Kbit, 2Kbit, 1Kbit and 256bit 8-bit or 16-bit wide
STMICROELECTR