A759BQ106M2CAAE090 [KEMET]

Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors;
A759BQ106M2CAAE090
型号: A759BQ106M2CAAE090
厂家: KEMET CORPORATION    KEMET CORPORATION
描述:

Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors

文件: 总16页 (文件大小:5443K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Overview  
Applications  
KEMET’s A759 Series of Single-Ended Conductive Polymer  
Aluminum Solid Electrolytic Capacitors offer longer life and  
greater stability across a wide range of temperatures. The  
A759 Series highly conductive solid polymer electrolyte  
eliminates the risk of explosion from drying out and due  
to its low ESR properties is able to withstand higher ripple  
currents during normal operation. The A759 Series are  
ideally suited for industrial and commercial applications.  
Typical applications include long life LED drivers,  
professional power amplifiers and industrial power supplies.  
Benefits  
• Through-hole form factor  
• High Voltage  
• Low impedance  
• High ripple current  
• 125°C/2,000 hours  
• RoHS compliant  
Click image above for interactive 3D content  
Open PDF in Adobe Reader for full functionality  
Part Number System  
A
759  
BQ  
106  
M
1V  
AA  
E090  
Capacitor  
Class  
Capacitance  
Code (pF)  
Rated Voltage  
(VDC)  
Series  
Size Code  
Tolerance  
M = ±20%  
Packaging  
ESR  
A = Aluminum  
Single-Ended  
Conductive  
Polymer Solid  
Capacitor  
125°C  
2,000 Hour  
See Dimension  
Table  
First two digits  
represent  
significant figures  
for capacitance  
values. Last digit  
specifies the  
35 = 1V  
50 = 1H  
63 = 1J  
100 = 2A  
160 = 2C  
250 = 2E  
See Ordering  
Options Table  
Last 3 digits  
represent  
significant  
figures for ESR  
values.(mΩ)  
number of zeros  
to be added.  
One world. One KEMET  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
1
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Ordering Options Table  
Lead Length  
(mm)  
Lead and  
Packaging Code  
Diameter  
Packaging Type  
Lead Type  
Standard Bulk Packaging Options  
Long Lead  
(Loose Standard Leads)  
5 – 18  
Bulk (bag)  
15 Minimum  
AA  
5(1)  
5(1)  
BA  
CA  
5 – 18  
5 – 18  
Bulk (bag)  
Bulk (bag)  
Cut Leads  
Formed Leads  
Standard Auto-Insertion Packaging Options  
5
Ammo Tape and Box  
Formed to 2.5 mm  
Formed to 5 mm  
H0 = 16±0.5  
FA  
5 – 8  
Ammo Tape and Box  
H0 = 16±0.5  
H = 18.5±0.5  
(for 8 x 12 H =  
20±0.5)  
DA  
6 – 8  
Ammo Tape and Box  
Straight  
Straight  
EA  
EA  
10 – 13  
Ammo Tape and Box  
H = 18.5±0.5  
Contact KEMET for other Lead and Packaging options  
(1)Contact KEMET for custom Lead Length and options 3 to 10 mm  
Long Lead (Loose Standard Leads)  
Diameter  
d
5
6.3  
8
10  
13  
18  
ꢃ ꢄꢅꢆ5  
d
F
0.5  
2
0.5  
2.5  
15  
0.6  
3.5  
15  
0.6  
5
0.6  
5
0.8  
7.5  
15  
H
15  
15  
15  
ꢁinimum  
ꢁinimum  
Cut Lead  
Diameter  
d
5
6.3  
8
10  
13  
18  
ꢄ ꢁꢂꢃ5  
d
F
0.5  
2
0.5  
2.5  
0.6  
3.5  
0.6  
5
0.6  
5
0.8  
7.5  
H
According to customer requirement 3 – 10 mm  
ꢀ ꢁꢂꢃ5  
Formed Lead  
d
Diameter  
5
6.3  
8
10  
13  
18  
ꢆ ꢄꢅꢀ5  
d
F
0.5  
5
0.5  
5
0.6  
5
0.6  
5
0.6  
5
0.8  
5
H
According to customer requirement 3 – 10 mm  
2ꢀ5  
ꢁaꢂimum  
ꢃ ꢄꢅꢀ5  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
2
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Dimensions – Millimeters  
d
P
15  
ꢂinimum  
ꢂinimum  
D
L
d
P
Size Code  
Nominal  
Tolerance  
Nominal  
Tolerance  
Nominal  
Tolerance  
Nominal  
Tolerance  
BQ  
EQ  
5
6.3  
8
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
11  
11  
8
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
±1.0  
0.5  
0.5  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
2.0  
2.5  
3.5  
3.5  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
±0.5  
KK  
KS  
8
12  
12  
16  
18  
20  
20  
31  
MS  
MW  
MX  
MY  
PY  
10  
10  
10  
10  
13  
18  
SZ  
Performance Characteristics  
Item  
Performance Characteristics  
2.2 – 680 µF  
Capacitance Range  
Rated Voltage  
35 – 250 VDC  
−55°C to +125°C  
Operating Temperature  
Capacitance Tolerance  
Life Test  
±20% at 120 Hz/20°C  
2,000 hours (see conditions in Test Method & Performance)  
I ≤ 0.15 CV or 120 µA, whichever is greater  
Leakage Current  
C = Rated capacitance (µF), V = Rated voltage (VDC), Voltage applied for 2 minutes at 20°C.  
Dissipation Factor (tan δ)  
Rated voltage (V)  
35 – 250  
0.12  
tan δ (Maximum) at 120 Hz/20°C  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
3
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Impedance Z Characteristics at 100 kHz  
Z (−25°C)/Z (20°C)  
Z (−55°C)/Z (20°C)  
≤ 1.25  
≤ 1.25  
Compensation Factor of Ripple Current (RC) vs. Frequency  
Frequency  
120 Hz ≤ f < 1 kHz  
1 kHz ≤ f < 10 kHz 10 kHz ≤ f < 100 kHz 100 kHz ≤ f < 500 kHz  
Coefficient  
0.05  
0.30  
0.70  
1.00  
Test Method & Performance  
Conditions  
Temperature  
Test Duration  
Ripple Current  
Load Life Test  
Shelf Life Test  
125°C  
125°C  
2,000 hours  
96 hours  
No ripple current applied  
No ripple current applied  
No voltage applied  
The sum of DC voltage and the peak AC voltage  
must not exceed the rated voltage of the capacitor  
Voltage  
Performance  
Capacitance Change  
Dissipation Factor  
ESR  
The following specifications will be satisfied when the capacitor is restored to 20°C.  
Within ±20% of the initial value  
Does not exceed 150% of the specified value  
Does not exceed 150% of the specified value  
Leakage Current  
Does not exceed specified value  
The following specifications will be satisfied when the capacitor is restored to 20°C  
after application of rated voltage for 1,000 hours at 60°C, 90%~95% RH.  
Damp Heat  
Capacitance Change  
Dissipation Factor  
ESR  
Within ±20% of the initial value  
Does not exceed 150% of the specified value  
Does not exceed 150% of the specified value  
Does not exceed specified value  
Leakage Current  
The following specifications will be satisfied when the capacitor is subjected to 1,000  
cycles each consisting of charge with the surge voltages specified at 105°C for 30  
seconds through a protective resistor (Rc = 1 kΩ) and discharge for 5 minutes 30  
seconds.  
Surge Voltage  
(Rated Voltage x 1.15 (V))  
Capacitance Change  
Dissipation Factor  
ESR  
Within ±20% of the initial value  
Does not exceed 150% of the specified value  
Does not exceed 150% of the specified value  
Does not exceed specified value  
Leakage Current  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
4
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Shelf Life and Re-Ageing  
• KEMET's conductive polymer aluminum solid electrolytic capacitors should not be stored in high temperatures or where  
there is a high level of humidity.  
• The suitable storage condition for KEMET's conductive polymer aluminum solid electrolytic capacitors is +5 to +35ºC and  
less than 75% in relative humidity.  
• KEMET's conductive polymer aluminum solid electrolytic capacitors should not be stored in damp conditions such as  
water, saltwater spray or oil spray.  
• KEMET's conductive polymer aluminum solid electrolytic capacitors should not be stored in an environment full of  
hazardous gas (hydrogen sulphide, sulphurous acid gas, nitrous acid, chlorine gas, ammonium, etc.)  
• KEMET's conductive polymer aluminum solid electrolytic capacitors should not be stored under exposure to ozone,  
ultraviolet rays or radiation.  
The capacitance, ESR and impedance of a capacitor will not change significantly after extended storage periods, however the  
leakage current will very slowly increase.  
If a capacitor is stored for a long period of time, the leakage current must be verified. If the leakage current is superior to the  
value listed in this catalog, the capacitors must be reformed.  
Re-age (Reforming) Procedure  
Apply the rated DC voltage to the capacitor at 105°C for a period of 120 minutes through a 1 kΩ series resistor.  
Environmental Compliance  
As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental  
effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like  
China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic  
equipment. All products in this catalog are produced to help our customers' obligations to guarantee their products and fulfill  
these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed  
from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will  
closely follow any changes in legislation worldwide and makes any necessary changes in its products, whenever needed.  
Some customer segments such as medical, military and automotive electronics may still require the use of Lead in electrode  
coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels  
for RoHS compatible capacitors.  
Because of customer requirements, there may appear additional markings such as LF = Lead-free, or LFW = Lead-free wires  
on the label.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
5
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Table 1 – Ratings & Part Number Reference  
RC  
RC  
LC  
20°C  
2 minutes  
(µA)  
VDC  
Surge  
Rated  
Capacitance  
Case Size  
D x L  
ESR  
100 kHz  
20°C (mΩ)  
100 Hz  
105°C  
(mA)  
340  
600  
100 kHz  
125°C  
(mA)  
KEMET  
Part Number  
VDC  
Voltage 120 Hz 20°C (µF)  
(mm)  
35  
35  
35  
35  
35  
50  
50  
50  
50  
50  
50  
50  
63  
63  
63  
63  
63  
40.2  
40.2  
40.2  
40.2  
40.2  
57.5  
57.5  
57.5  
57.5  
57.5  
57.5  
57.5  
72.5  
72.5  
72.5  
72.5  
72.5  
72.5  
115  
10  
22  
33  
100  
150  
10  
22  
39  
68  
100  
440  
680  
47  
68  
82  
150  
220  
330  
4.7  
15  
22  
10  
15  
18  
2.2  
3.3  
4.7  
6.8  
8.2  
82  
5 x 11  
5 x 11  
5 x 11  
8 x 12  
10 x 12  
5 x 11  
90  
80  
75  
31  
30  
105  
75  
42  
32  
31  
28  
26  
68  
47  
50  
48  
45  
42  
160  
52  
45  
110  
94  
90  
685  
512  
496  
482  
458  
150  
200  
350  
400  
2500  
2700  
220  
120  
120  
173  
525  
788  
120  
165  
293  
510  
750  
3300  
5100  
444  
643  
775  
1418  
2079  
3119  
120  
225  
330  
240  
360  
432  
120  
124  
176  
A759BQ106M1V(1)E090  
A759BQ226M1V(1)E080  
A759BQ336M1V(1)E075  
A759KS107M1V(1)E031  
A759MS157M1V(1)E030  
A759BQ106M1H(1)E105  
A759BQ226M1H(1)E075  
A759KS396M1H(1)E042  
A759MS686M1H(1)E032  
A759MS107M1H(1)E031  
A759MY447M1H(1)E028  
A759PY687M1H(1)E026  
A759KS476M1J(1)E068  
A759MS686M1J(1)E047  
A759MS826M1J(1)E050  
A759MW157M1J(1)E048  
A759MY227M1J(1)E045  
A759PY337M1J(1)E042  
A759EQ475M2A(1)E160  
A759KS156M2A(1)E052  
A759MS226M2A(1)E045  
A759KS106M2C(1)E110  
A759MS156M2C(1)E094  
A759MS186M2C(1)E090  
A759KK225M2E(1)E685  
A759KS335M2E(1)E512  
A759KS475M2E(1)E496  
A759MS685M2E(1)E482  
A759MS825M2E(1)E458  
A759SZ826M2E(1)E150  
690  
4290  
4630  
380  
5 x 11  
8 x 12  
560  
310  
950  
1630  
2300  
2830  
6010  
6520  
1630  
1970  
2500  
2610  
3600  
4030  
510  
1850  
2300  
1350  
1580  
1944  
210  
10 x 12  
10 x 12  
10 x 20  
13 x 20  
8 x 12  
10 x 12  
10 x 12  
10 x 16  
10 x 20  
13 x 20  
6.3 x 11  
8 x 12  
10 x 12  
8 x 12  
10 x 12  
10 x 12  
8 x 8  
1440  
1650  
3500  
3800  
950  
1150  
1380  
1520  
2100  
2350  
300  
680  
720  
550  
685  
720  
70  
175  
210  
63  
100  
100  
100  
160  
160  
160  
250  
250  
250  
250  
250  
250  
115  
115  
184  
184  
184  
287.5  
287.5  
287.5  
287.5  
287.5  
287.5  
8 x 12  
8 x 12  
10 x 12  
10 x 12  
18 x 31  
450  
650  
780  
950  
250  
315  
3520  
255  
308  
3075  
6040  
VDC  
VDC Surge  
Rated Capacitance  
Case Size  
ESR  
RC  
LC  
Part Number  
(1) Please see packaging codes for options.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
6
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Installing  
Conductive polymer aluminum solid electrolytic capacitors are prone to a change in leakage current due to thermal  
stress during soldering. The leakage current may increase after soldering or reflow soldering. Therefore, do not use these  
capacitors in circuits sensitive to leakage current.  
• Do not use in a high resistance, high voltage circuit.  
• Do not use in a coupling circuit.  
• Do not use in a time constant circuit.  
• Do not use in a circuits that are significantly affected by leakage current.  
A general principle is that lower temperature operation results in a longer, useful life of the capacitor. For this reason, it  
should be ensured that electrolytic capacitors are placed away from heat-emitting components. Adequate space should be  
allowed between components for cooling air to circulate, especially when high ripple current loads are applied. In any case,  
the maximum rated temperature must not be exceeded.  
• Do not deform the case of capacitors or use capacitors with a deformed case.  
• Verify that the connections of the capacitors are able to insert on the board without excessive mechanical force.  
Excessive force during insertion, as well as after soldering may cause terminal damage and affect the electrical  
performance.  
• Ensure electrical insulation between the capacitor case, negative terminal, positive terminal and PCB.  
• If the capacitors require mounting through additional means, the recommended mounting accessories shall be used.  
• Verify the correct polarization of the capacitor on the board.  
KEMET recommends, to ensure that the voltage across each capacitor does not exceed its rated voltage.  
Temperature Stability Characteristics  
Stable characteristics in a very low temperature range allows for less circuits in the design.  
Due to a solid polymer electrolyte, conductive polymer electrolytic capacitors feature higher conductivity. This results  
in a lower ESR which, coupled with high capacitance allows an aluminum polymer capacitor to replace several standard  
electrolytic capacitors, reducing the number of components and maximizing board space.  
The ESR of polymer capacitors is nearly constant within its operating temperature range, while the ESR of a standard  
electrolytic capacitor noticeably changes with temperature.  
Temperature Stability Characteristics  
1,000  
Aluminum Electrolytic  
Conductive Polymer Electrolytic  
100  
10  
1
0.1  
0.01  
55  
20  
0
20  
70  
105  
125  
Temperature (ºC)  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
7
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Expected Life Calculation Chart  
Expected life depends on operating temperature according to the following formula:  
L = Lo x 10(To-T)/20  
Where:  
L: Expected life  
Lo: Life at maximum permissible operating temperature with rated operating voltage applied (hours)  
T: Actual operating temperature  
To: Maximum permissible operating temperature  
Expected Life Calculation Chart  
1ꢀ5ꢂC  
ꢁ5ꢂC  
ꢃ5ꢂC  
2,ꢀꢀꢀ  
2ꢀ,ꢀꢀꢀ  
2ꢀꢀ,ꢀꢀꢀ  
ꢀꢁꢂeꢃꢄed Liꢅe ꢆꢇꢈꢉrꢊꢋ  
The effect of derating temperature can be seen in this graph.  
In this example, the life expectancy of a 2,000 hour Polymer capacitor is significantly greater than that of a 2,000 hour  
standard electrolytic capacitor.  
Capacitor Life (H)  
5ꢁ,ꢁꢁꢁ  
1ꢁꢁ,ꢁꢁꢁ  
15ꢁ,ꢁꢁꢁ  
2ꢁꢁ,ꢁꢁꢁ  
1ꢁ5  
1ꢁꢁ  
95  
Aluminum Electrolytic  
Conductive Polymer Electrolytic  
9ꢁ  
ꢂ5  
ꢂꢁ  
75  
7ꢁ  
ꢀ5  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
8
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Ultra Low Impedance at High Frequency  
Due to a solid polymer electrolyte, the curve of a conductive polymer electrolytic capacitor, (Z and ESR) is significantly lower  
than that of a standard electrolytic capacitor.  
Ultra Low Impedance at High Frequency (Low ESR)  
1ꢀꢀ  
Aluminum Electrolytic  
Conductive Polymer Electrolytic  
1ꢀ  
1
ꢀꢁ1  
ꢀꢁꢀ1  
1ꢀꢂ  
1ꢀꢀꢂ  
1ꢃ  
1ꢀꢃ  
Freꢀꢁenꢂꢃ ꢄꢅꢆꢇ  
High Resistance to Ripple Current  
As a result of a lower ESR, conductive polymer electrolytic capacitors are able to withstand higher ripple currents during  
normal operation.  
Allowable Ripple Current (100 kHz 105ºC)  
ꢂꢁ5  
Aluminum Electrolytic  
Conductive Polymer Electrolytic  
2ꢁ5  
2
1ꢁ5  
1
ꢀꢁ5  
ꢂꢂ ꢄꢅꢆ1ꢇ ꢈ  
ꢃ7 ꢄꢅꢆ1ꢇ ꢈ  
1ꢀꢀ ꢄꢅꢆ1ꢇ ꢈ  
22ꢀ ꢄꢅꢆ1ꢇ ꢈ  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016  
9
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Construction  
Aluminum Can  
Deꢀaiꢁed ꢂrꢃꢄꢄ ꢅeꢆꢀiꢃn  
ꢄead  
ꢁuꢂꢂer Seal  
ꢃerminal ꢃaꢂs  
ꢃerminal ꢃaꢂ  
ꢁuꢂꢂer Seal  
ꢀargin  
Aluminum Can  
Paper Spacer ꢇitꢆ Solid  
Polymer Electrolyte  
ꢊꢅirst ꢄayerꢋ  
ꢄead ꢊꢌꢋ  
Paper Spacer ꢇitꢆ Solid  
Polymer Electrolyte  
ꢊꢃꢆird ꢄayerꢋ  
Anode Aluminum ꢅoil,  
Catꢆode Aluminum  
Etcꢆed, Covered ꢇitꢆ  
ꢅoil, Etcꢆed  
Aluminum ꢈꢉide  
ꢊꢅourtꢆ ꢄayerꢋ  
ꢄead ꢊꢋ  
ꢊSecond ꢄayerꢋ  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 10  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Marking  
ꢊrademarꢋ  
egative Polarity  
ꢁlue ꢂine  
Series  
Capacitance ꢃꢄꢅꢆ  
ꢇated ꢈoltage ꢃꢈꢉCꢆ  
Flow Soldering (not suitable for SMD parts)  
The soldering conditions should be within the specified conditions below:  
• Do not dip the capacitors body into the melted solder.  
• Flux should only be applied to the capacitors terminals.  
• Vapour heat transfer systems are not recommended. The system should be thermal, such as infra-red radiation or hot  
blast.  
• Observe the soldering conditions as shown below.  
• Do not exceed these limits and avoid repeated reflowing.  
Flow Soldering  
Temperature  
(°C)  
Maximum Time  
(Seconds)  
<120  
Maximum  
Repetitions  
Pre-heat  
Solder  
<120  
1
260 ± 5°C  
<10  
2
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 11  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Taping for Automatic Insertion Machines  
P2  
P
P2  
P
ꢆ1  
ꢆ1  
ꢆ  
ꢆ  
P1  
ꢅ2  
ꢃ1  
P1  
ꢃ1  
ꢅ2  
d
d
ꢁ1  
ꢃo  
ꢃo  
A
A
ꢅ1  
ꢅꢄ  
ꢅ1  
ꢅꢄ  
t
t
Pꢄ  
ꢂꢄ  
ꢂꢄ  
Pꢄ  
P2  
P
P2  
P
ꢆ1  
ꢆ1  
ꢆ  
ꢆ  
ꢃ1  
ꢃ1  
ꢅ2  
ꢅ2  
P1  
P1  
d
d
ꢁ1  
A
A
ꢅ1  
ꢅ1  
ꢅꢄ  
t
t
ꢅꢄ  
Pꢄ  
ꢂꢄ  
ꢂꢄ  
Pꢄ  
Dimensions  
(mm)  
D
L
d
P
P0 P1 P2  
F
W
W0 W1 W2  
H
Ho D0  
A
H1 ∆h ∆h1  
t
Tolerance  
±0.5  
±0.02 ±1.0 ±0.2 ±0.7 ±1.0 ±0.5 ±0.5 min ±0.5 max ±0.75 ±0.5 ±0.2 Max. Max. ±2  
±1  
±0.3  
7.0  
Formed to 2.5mm  
Formed to 5mm  
5
5
0.5 12.7 12.7 5.1 6.35 2.5 18 12.5  
9
9
1.5 17.5 16  
1.5 18.5 16  
9-11  
7-11  
6.3 8-11 0.5  
12.7 12.7 3.85 6.35  
5
18 12.5  
18 12.5  
18 12.5  
8.0  
8
32.5  
12.0 0.6  
6.3 8-11  
0.5  
2.5  
3.5  
4
11  
0
0
0.7  
18.5  
1.5  
Straight leads  
6 - 8mm  
12.7 12.7 5.4 6.35  
12.7 12.7 3.85 6.35  
9
9
8.0  
8
12.0 0.6  
20  
--  
12  
33  
36  
16.0  
10  
Straight leads  
10 - 13mm  
18.0 0.6  
5
1.5 18.5  
41  
20.0  
13 20.0  
15  
15  
5
7.5  
40.5  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 12  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Construction Data  
Anode foil  
Cathode foil  
Foil tabs  
The manufacturing process begins with the anode foil being  
electrochemically etched to increase the surface area and  
then ‘formed’ to produce the aluminum oxide layer. Both the  
anode and cathode foils are then interleaved with absorbent  
paper and wound into a cylinder. During the winding process,  
aluminum tabs are attached to each foil to provide the  
electrical contact.  
Tissues  
The deck, complete with terminals, is attached to the tabs  
and then folded down to rest on top of the winding. The  
complete winding is impregnated with a conductive polymer  
electrolyte before being housed in a suitable container, usually  
an aluminum can, and sealed. Throughout the process, all  
materials inside the housing must be maintained at the  
highest purity and be compatible with the electrolyte.  
ꢀꢁiꢂꢂing  
ꢀꢁiꢁꢂꢃing  
Winding  
Weꢀding  
Fꢀrꢁing  
Each capacitor is aged and tested before being packed.  
The purpose of aging is to repair any damage in the oxide  
layer and thus reduce the leakage current to a very low level.  
Aging is normally carried out at the rated temperature of the  
capacitor and is accomplished by applying voltage to the  
device while carefully controlling the supply current. The  
process may take several hours to complete. Damage to the  
oxide layer can occur due to variety of reasons:  
ꢀarꢁꢂniꢃaꢄiꢂn  
ꢀꢁeaning  
• Slitting of the anode foil after forming  
Deꢀiꢁꢁaꢂiꢃn  
ꢀaꢁꢂraꢁing  
ꢀeꢁꢂrꢃing  
Aꢀꢀeꢁꢂꢃing  
ꢀꢁeaning  
• Attaching the tabs to the anode foil  
• Minor mechanical damage caused during winding  
Marking  
Aging  
ꢀeꢁꢂing  
ꢀnꢁꢂeꢃꢄiꢅn  
Paꢀking  
ꢀꢁꢂꢃking  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 13  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Product Safety  
THESE NOTES SHOULD BE READ IN CONJUNCTION WITH THE PRODUCT DATA SHEET. FAILURE TO OBSERVE THE RATINGS  
AND THE INFORMATION ON THIS SHEET MAY RESULT IN A SAFETY HAZARD.  
Warning  
When potential lethal voltages e.g. 30 VAC (RMS) or 60 VDC are applied to the terminals of this product, the use of a  
hazard warning label is recommended.  
1. Electrolyte  
Conductive polymer aluminum solid electrolytic capacitors contain polymers (electrolytes) which can be hazardous.  
1.1 Safety Precautions  
In the event of gas venting, avoid contact and inhalation. Wash the affected area with hot water. Use rubber gloves to avoid  
skin contact. Any contact with the eyes should be liberally irrigated with water and medical advice sought.  
2. Intrinsic Properties  
2.1 Operating  
DC capacitors are polar devices and will operate safely only if correctly connected. Reversing the connections will result  
in high leakage currents which could subsequently cause short circuit failure and possibly explosion and fire. Correctly  
polarized operation may result in the above failure modes if:  
• The surge voltage is exceeded  
• The ambient temperature is too high  
• Excessive ripple currents are applied  
2.2 Non-Operating  
Excessive torque or soldering heat may affect the performance of the capacitor or damage the sealing. Electric shock may  
result if capacitors are not discharged.  
3. Disposal  
Aluminum electrolytic capacitors are consignable waste under the Special Waste Regulations 1996 (Statutory Instrument  
1996 No 972), which complies with the EC Hazardous Waste Directive – Directive 91/689/EEC. The electrolyte should  
therefore be treated as a hazardous waste and advice should be sought from the local office of the Environmental Agency  
regarding its disposal.  
Due to the construction of an aluminum electrolytic capacitors, high temperature incineration may cause the component to  
explode due to build-up of internal pressure. In addition, incineration may also cause the emission of noxious fumes.  
KEMET strongly recommends that if there are any doubts regarding the disposal of conductive polymer aluminum solid  
electrolytic capacitors, that advice be sought from the local regulating authority.  
In addition, KEMET would like to request that users of aluminum electrolytic capacitors respect the needs of the environment  
and, wherever possible, recover as much of the materials as possible, i.e. aluminum.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 14  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
Product Safety cont'd  
4. Unsafe Use  
Most failures are of a passive nature and do not represent a safety hazard. A hazard may, however, arise if this failure causes  
a dangerous malfunction of the equipment in which the capacitor is employed. Circuits should be designed to fail safe under  
the normal modes of failure.  
The usual failure mode is an increase in leakage current or short circuit. Other possible modes are decrease of capacitance,  
increase in dissipation factor (and impedance) or an open circuit. Capacitors should be used in a well-ventilated enclosure or  
cabinet.  
5. Mounting  
Care should be taken when mounting by clamp, that any safety vent in the can is not covered.  
6. Fumigation  
In many countries throughout the world it is now common practice to fumigate shipments of products in order to control  
insect infestation, particularly when wooden packaging is used. Currently, methyl bromide is widely used as a fumigant,  
which can penetrate cardboard packing and polymer bags and, therefore, come into direct contact with equipment or  
components contained within.  
If aluminum electrolytic capacitors become exposed to methyl bromide then corrosion may occur, depending upon the  
concentration and exposure time to the chemical.  
This failure mode can affect all types of KEMET aluminum electrolytic capacitors. Methyl bromide can penetrate the seals of  
aluminum electrolytic capacitors and cause internal corrosion of the anode connection, resulting in the component becoming  
open circuit. The rate of corrosion will depend upon the level of exposure to methyl bromide as well as the subsequent  
operating conditions, such as voltage and temperature. It may take months or, in some cases, several years before the  
component becomes open circuit.  
7. Dielectric Absorption  
A phenomenon known as dielectric absorption can cause aluminum electrolytic capacitors to recharge themselves. The  
phenomenon is well known but impossible to predict with any great accuracy, so potentially any electrolytic product could be  
affected. Thus, a capacitor that has been charged and then completely discharged will appear to recharge itself if left open  
circuit; this will manifest itself as a small voltage across the terminals of the capacitor. Generally, the voltages seen are less  
than 20 VDC. However, higher voltages have on occasion been reported.  
In order to avoid any problems caused by this voltage, KEMET recommends that capacitors be discharged before connecting  
to the terminals.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 15  
Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors  
A759 Series, 125°C  
KEMET Electronic Corporation Sales Offices  
For a complete list of our global sales offices, please visit www.kemet.com/sales.  
Disclaimer  
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for  
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.  
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such  
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.  
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any  
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no  
obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component  
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards  
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or  
property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other  
measures may not be required.  
KEMET is a registered trademark of KEMET Electronics Corporation.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
A4072_A759 • 12/13/2016 16  

相关型号:

A759BQ106M2EAAE090

Single-Ended Conductive Polymer Aluminum Solid Electrolytic Capacitors
KEMET

A759EA106M1JAAE060

A759, Polymer Aluminum, 10 uF, 20%, 63 VDC, -55/+125°C, Lead Spacing = 2.5mm
KEMET

A759EK227M1AAAE018

A759, Polymer Aluminum, 220 uF, 20%, 10 VDC, -55/+125°C, Lead Spacing = 2.5mm
KEMET

A759KC276M1JAAE054

A759, Polymer Aluminum, 27 uF, 20%, 63 VDC, -55/+125°C, Lead Spacing = 3.5mm
KEMET

A759KK225M2EAAE685

Aluminum Electrolytic Capacitor, Aluminum (solid Polymer)
KEMET

A759KR227M1VAAE024

A759, Polymer Aluminum, 220 uF, 20%, 35 VDC, -55/+125°C, Lead Spacing = 3.5mm
KEMET

A759KS107M1VAAE031

A759, Polymer Aluminum, 100 uF, 20%, 35 VDC, -55/+125°C, Lead Spacing = 3.5mm
KEMET

A759KS157M1EAAE025

A759, Polymer Aluminum, 150 uF, 20%, 25 VDC, -55/+125°C, Lead Spacing = 3.5mm
KEMET

A759KS827M1AAAE013

A759, Polymer Aluminum, 820 uF, 20%, 10 VDC, -55/+125°C, Lead Spacing = 3.5mm
KEMET

A759MS107M1HAAE031

Aluminum Electrolytic Capacitor, Aluminum (solid Polymer)
KEMET

A759MS156M2CAAE094

Aluminum Electrolytic Capacitor, Aluminum (solid Polymer)
KEMET

A759MS157M1VAAE030

Aluminum Electrolytic Capacitor, Aluminum (solid Polymer)
KEMET