IXCP02U45 [IXYS]

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN;
IXCP02U45
型号: IXCP02U45
厂家: IXYS CORPORATION    IXYS CORPORATION
描述:

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN

局域网
文件: 总3页 (文件大小:552K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VAK  
=
450  
V
High Voltage Current  
Regulators  
IXC Series  
IA(P) = 2 - 60 mA  
RDYN = 9 - 900 k  
Preliminary Data Sheet  
AC non-switchable regulators  
The IXYS IXC series of high voltage  
current regulators consists of non-  
switchable, 2-terminal, AC and DC  
current regulators.  
TO-220 AB  
(IXCP)  
This family consists of two DC current  
regulators connected internally in  
series to regulate the current to a  
specified value in both directions. Its  
output characteristics in quadrants 1  
and 3 are the same as shown in Figure  
1 so that the current regulation is also  
the same in both directions. Parts are  
only available in the TO-220 package.  
TO-252 AA  
(IXCY)  
4
4
1
3
1
2
3
Features  
z
Extremely stable current character-  
istics 50 ppm/K)  
z
z
Minimum of 450 V breakdown  
Easily configured for bidirectional  
current sourcing  
40 W continuous dissipation  
International standard packages  
JEDEC TO-220 and TO-252  
Current Regulator Nomenclature  
z
z
Partscanbeorderedbyusingthefollowing  
nomenclature:  
Fig. 1. Current Regulator Output  
Characteristics  
IXCP10M45A (Example)  
IX  
IXYS  
C
Current Regulator  
Package style  
TO-220 AB  
Non-switchable regulators  
Applications  
This is a family of extremely stable,  
high voltage current regulators with  
the typical output characteristic shown  
in Figure 1. The temperature stability  
is based on a threshold compensation  
technique and uses IXYS' most  
recently developed high voltage  
process. The complete family will be  
capable of providing other  
intermediate current levels which can  
be programmed on-chip during the  
manufacturing phase.  
z
PABX current sources  
P
Y
z
Telephone line terminations in  
PABXs and modems  
TO-252 (D-PAK)*  
Current Rating,  
10 = 10 mA  
Current Level  
A = Amps, M = mA,  
U = µA  
Voltage rating  
45 = 450 V  
10  
z
z
Highly stable voltage sources  
Surge limiters and voltage protection  
(DC and AC)  
M
z
Instantaneously reacting resetable  
fuses  
45  
z
z
Waveform synthesizers  
Soft start-up circuits  
Specific applications are current  
sourcing in PABX applications,  
telephone line terminations, surge  
protection and voltage supply  
protection. Two devices in a back-to-  
back configuration will give  
bidirectional operation. Specific  
bidirectional applications would be  
series surge protection and soft start-  
up applications from AC mains.  
Fig. 2. Block diagram for the non-switchable regulator  
1
© 2004 IXYS All rights reserved  
DS98703A (7/04)  
IXC Series  
TO-220 AB Outline  
Non-Switchable DC Current Regulators  
Symbol  
Definition  
Maximum Ratings  
VAK  
PD  
Drain Source Voltage  
450  
V
Power Dissipation  
(TC = 25°C)  
IXC_02M to IXC_50M  
IXC_60M & IXC_100M  
25  
40  
W
W
IRM  
Maximum Reverse Current  
1
A
TJ  
Tstg  
TL  
Junction Operating Temperature  
Storage Temperature  
Temperature for soldering (max. 10 s)  
-55 to +150  
-55 to +150  
260  
°C  
°C  
°C  
MD  
Mounting torque with screw M3 (TO-220)  
with screw M3.5 (TO-220)  
0.45/4 Nm/lb.in.  
0.55/5 Nm/lb.in.  
Symbol  
Definition/Condition  
Characteristic Values  
(TJ = 25°C, unless otherwise specified)  
min.  
typ.  
max.  
BVAK*  
Breakdown  
voltage:  
__M45 ID = 1.5 IA(P)  
450  
V
IA(P)  
Plateau  
Current  
02M__ VAK = 10 V  
10M__  
1.9  
9.0  
2.0  
10  
2.5  
11.8  
mA  
mA  
20M__  
18  
20  
22  
mA  
TO-252 AA Outline  
40M__  
50M__  
60M__  
100M__  
36  
45  
56  
88  
40  
50  
44  
55  
mA  
mA  
mA  
mA  
60  
64  
100  
110  
IA(P)/T  
Plateau Current Shift  
with Temperature  
VAK= 10 V  
±50  
ppm/K  
VAK/IA(p)  
Dynamic  
Resistance  
02M__ VAK = 10 V  
10M__  
800  
160  
78  
19  
15  
8
900  
180  
85  
21  
17  
9
kΩ  
kΩ  
kΩ  
kΩ  
kΩ  
kΩ  
20M__  
50M__  
60M__  
100M__  
VF  
Diode forward voltage drop; IF = 50mA  
1.8  
V
RthJC Thermal Resistance junction-to-case  
IXC_02M to IXC_50M 5.0 K/W  
IXC_60M & IXC_100M 3.1 K/W  
Dim. Millimeter  
Inches  
Max.  
Min. Max. Min.  
RthJA Thermal Resistance junction-to-ambient TO-220  
80 K/W  
A
2.19 2.38 0.086 0.094  
A1 0.89 1.14 0.035 0.045  
TO-252  
100 K/W  
A2  
b
0
0.13  
0
0.005  
0.64 0.89 0.025 0.035  
* Pulse test to limit power dissipation to within device capability.  
b1 0.76 1.14 0.030 0.045  
b2 5.21 5.46 0.205 0.215  
c
0.46 0.58 0.018 0.023  
c1 0.46 0.58 0.018 0.023  
5.97 6.22 0.235 0.245  
D1 4.32 5.21 0.170 0.205  
6.35 6.73 0.250 0.265  
E1 4.32 5.21 0.170 0.205  
D
E
e
2.28 BSC  
4.57 BSC  
9.40 10.42 0.370 0.410  
0.51 1.02 0.020 0.040  
0.090 BSC  
0.180 BSC  
Pin connections  
Product Marking  
e1  
H
L
1
= No connection  
2, 4 = Positive terminal A  
= Negative terminal K  
TO-220 types - full part number  
TO-252 - last 7 alpha-numeric characters of the  
part number, e.g. CY02M45  
L1 0.64 1.02 0.025 0.040  
L2 0.89 1.27 0.035 0.050  
L3 2.54 2.92 0.100 0.115  
3
2
IXC Series  
Application Examples  
DC and AC Overvoltage  
Suppression  
The regulator can be used as a  
voltage surge suppressor. The device  
is again connected in series with the  
lead (Fig. 5) and would normally  
operate at a current level lower than  
the plateau (Fig. 6a). Any incoming  
voltage surge (Fig. 6b) less than the  
breakdown voltage of the regulator will  
be clamped by the IXCP regulator to  
voltage less than the plateau current  
times the effective resistance of the  
load.  
Fig. 5. DC surge suppression  
source of a highly stable current to  
produce a usable voltage reference  
(Fig. 7). This would be effectively  
independent of temperature and a low  
cost approach. A high voltage  
reference is also possible, thanks to  
their high breakdown voltages.  
Fig.8. Low cost current regulators  
instead of fuses  
The obvious advantages to having this  
regulator as fuse substitute are:  
z Prevents a "dip" in the power  
supply during a fault condition  
z Regulator remains intact  
z Can be easily tied in with logic to  
indicate a "down state" board  
R = 100 Vout = 3.5 V nominal  
R = 50 Ω  
R = 25 Ω  
Vout = 1.75 V nominal  
Vout = 0.875 V nominal  
Fig. 7. Simple voltage source with  
high stability  
Fig. 6a. DC surge suppression  
Instantaneous "Fuse"  
Another application would be  
protection against sudden voltage  
droops on voltage supply lines to logic  
cards in computing systems, resulting  
from one component suddenly  
shorting to ground. Normal fusing  
networks will draw considerable  
current during the time it takes for the  
fuse to clear. This could cause a  
sufficient dip in power rail voltage to  
cause malfunctions of the other logic  
cards, even with fast-blow fuses (Fig.  
8). The current regulator in series with  
the logic card restricts the current to  
its own operating level (Fig. 9).  
Therefore the voltage supply does not  
become overloaded and the regulator  
remains intact.  
Fig. 6b. Incoming surge/output surge  
across load  
Fig. 9. Normal fusing links in  
series with each board  
Soft Start-Up Circuits  
Here the regulator characteristic will  
clamp initial current surges which can  
occur when power is initially applied  
to a load. The device, with its 450 V  
capability could, for example, be used  
with a DC power supply or with AC  
mains to limit the initial high inrush of  
current into lamp filaments, thereby  
increasing the filament life several  
times. It could, therefore, be used  
effectively in lighting displays and in  
the transportation lighting industries.  
Testing & Handling  
Recommendations  
z For initial assessment of the parts  
where the customer may test the  
device characteristics in free air  
without heat sinking, the continuous  
power dissipation should be kept  
within 1.5 W at ambient of 25°C.  
(R  
= 80 K/W for TO-220, and  
RthtJhAJA= 100 K/W for TO-252)  
The current regulator thus provides an  
"instantaneous fusing" function. When  
the logic component is replaced, the  
regulator resumes its normal  
functioning mode.  
z Normal electrostatic handling  
precautions for MOS devices  
should be adhered to.  
Highly Stable Voltage Sources  
Another obvious application would be  
to use the current regulator as a  
IXYS MOSFETs and IGBTs are covered by 4,835,592 4,931,844  
one or moreof the following U.S. patents: 4,850,072 5,017,508  
4,881,106 5,034,796  
5,049,961  
5,063,307  
5,187,117  
5,237,481  
5,381,025  
5,486,715  
6,162,665  
6,259,123 B1  
6,306,728 B1  
6,404,065 B1 6,683,344  
6,727,585  
6,710,405B2 6,759,692  
6,710,463  
6,534,343  
6,583,505  
3

相关型号:

IXCP02U45A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100A35

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100A35A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100A45

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100A45A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100M35A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100M45

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100M45A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100U35

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100U35A

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS

IXCP100U45

Analog Circuit, 1 Func, PSFM3, TO-220AB, 3 PIN
IXYS