AFL283R3S [INFINEON]

HYBRID-HIGH RELIABILITY DC/DC CONVERTER;
AFL283R3S
型号: AFL283R3S
厂家: Infineon    Infineon
描述:

HYBRID-HIGH RELIABILITY DC/DC CONVERTER

文件: 总10页 (文件大小:194K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PD-94525D  
AFL2803R3S  
28V Input, 3.3V Output  
HYBRID-HIGH RELIABILITY  
DC/DC CONVERTER  
Description  
The AFL Series of DC/DC converters feature high power  
density with no derating over the full military temperature  
range. This device is offered as part of a complete family  
of converters providing single and dual output voltages  
originally created to operate over a nominal input  
voltage range of 28V to 270V with output power ranging  
from 66W to 120W. For applications requiring higher  
output power, multiple converters can be operated in  
parallel. The internal current sharing circuits assure  
equal current distribution among the paralleled  
converters. This series incorporates International  
Rectifier’s proprietary magnetic pulse feedback  
technology providing optimum dynamic line and load  
regulation response. This feedback system samples  
the output voltage at the pulse width modulator fixed  
clock frequency, nominally 550KHz. Multiple converters  
can be synchronized to a system clock in the 500KHz  
to 700KHz range or to the synchronization output of  
one converter. Undervoltage lockout, primary and  
secondary referenced inhibit, soft-start and load fault  
protection are provided on all models.  
AFL  
Features  
n 16V To 40V Input Range  
n 3.3V Output  
n High Power Density - 50W/in  
n 66W Output Power  
n Parallel Operation with Stress and Current  
Sharing  
n Low Profile (0.380") Seam Welded Package  
n Ceramic Feedthru Copper Core Pins  
n High Efficiency - to 74%  
n Full Military Temperature Range  
n Continuous Short Circuit and Overload Protection  
n Remote Sensing Terminals  
n Primary and Secondary Referenced  
Inhibit Functions  
3
n Line Rejection > 40dB - DC to 50KHz  
n External Synchronization Port  
n Fault Tolerant Design  
n Dual Output Versions Available  
n Standard Microcircuit Drawing Available  
These converters are hermetically packaged in two  
enclosure variations, utilizing copper core pins to  
minimize resistive DC losses. Three lead styles are  
available, each fabricated with International Rectifier’s  
rugged ceramic lead-to-package seal assuring long term  
hermeticity in the most harsh environments.  
Manufactured in a facility fully qualified to MIL-PRF-  
38534, these converters are fabricated utilizing DSCC  
qualified processes. For available screening options,  
refer to device screening table in the data sheet.  
Variations in electrical, mechanical and screening can  
be accommodated. Contact IR Santa Clara for special  
requirements.  
www.irf.com  
1
03/08/07  
AFL2803R3S  
Specifications  
Absolute Maximum Ratings  
Input voltage  
-0.5V to +50VDC  
300°C for 10 seconds  
-55°C to +125°C  
-65°C to +135°C  
Soldering temperature  
Operating case temperature  
Storage case temperature  
Electrical Performance Characteristics -55°C < TCASE < +125°C, 16V< VIN < 40V unless otherwise specified.  
Group A  
Parameter  
INPUT VOLTAGE  
Subgroups  
Test Conditions  
Min  
Nom  
Max  
Unit  
Note 6  
= 28 Volts, 100% Load  
16  
28  
40  
V
OUTPUT VOLTAGE  
V
IN  
1
3.27  
3.23  
3.30  
3.33  
3.37  
V
2, 3  
OUTPUT CURRENT  
VIN = 16, 28, 40 Volts,, Note 6  
20  
66  
A
W
OUTPUT POWER  
Note 6  
Note 1  
MAXIMUM CAPACITIVE LOAD  
4
10,000  
-0.015  
µF  
OUTPUT VOLTAGE  
TEMPERATURE COEFFICIENT  
VIN = 28 Volts, 100% Load  
Note 1, 6  
+0.015  
%/°C  
OUTPUT VOLTAGE REGULATION  
1, 2, 3  
1, 2, 3  
No Load, 50% Load, 100% Load  
VIN = 16, 28, 40 Volts,  
-20  
-35  
+20  
+35  
mV  
Line  
Load  
OUTPUT RIPPLE VOLTAGE  
VIN = 16, 28, 40 Volts,, 100% Load,  
BW = 10MHz  
1, 2, 3  
30  
mV  
pp  
pp  
VIN = 28 Volts,  
INPUT CURRENT  
I
= 0  
1
80  
100  
5.0  
50  
No Load  
OUT  
2, 3  
mA  
Pin 4 Shorted to Pin 2  
Pin 12 Shorted to Pin 8  
1, 2, 3  
1, 2, 3  
Inhibit 1  
Inhibit 2  
INPUT RIPPLE CURRENT  
VIN = 28 Volts, 100% Load  
B.W. = 10MHz  
1, 2, 3  
60  
mA  
CURRENT LIMIT POINT  
V
= 90% V  
NOM  
Note 5  
OUT  
1
2
3
115  
105  
125  
125  
115  
140  
Expressed as a Percentage  
of Full Rated Load  
%
LOAD FAULT POWER DISSIPATION  
VIN = 28 Volts,  
1, 2, 3  
1, 2, 3  
1, 2, 3  
1
33  
W
%
Overload or Short Circuit  
EFFICIENCY  
VIN = 28 Volts, 100% Load  
72  
74  
SWITCHING FREQUENCY  
ISOLATION  
500  
100  
550  
600  
KHz  
MΩ  
Input to Output or Any Pin to Case  
(except Pin 3). Test @ 500VDC  
MTBF  
MIL-HDBK-217F, AIF @ T = 40°C  
C
300  
KHrs  
For Notes to Specifications, refer to page 3  
2
www.irf.com  
AFL2803R3S  
Elecrical Performance Characteristics (Continued)  
Group A  
Parameter  
ENABLE INPUTS  
Subgroups  
Test Conditions  
Min  
Nom  
Max  
Unit  
(Inhibit Function)  
1, 2, 3  
1, 2, 3  
Logical Low, Pin 4 or Pin 12  
-0.5  
2.0  
0.8  
100  
50  
V
µA  
V
Converter Off  
Sink Current  
Converter On  
Sink Current  
Note 1  
Logical High, Pin 4 and Pin 12 - Note 9  
Note 1  
100  
µA  
SYNCHRONIZATION INPUT  
Frequency Range  
1, 2, 3  
1, 2, 3  
1, 2, 3  
500  
2.0  
-0.5  
700  
10  
0.8  
100  
80  
KHz  
V
V
ns  
%
Pulse Amplitude, Hi  
Pulse Amplitude, Lo  
Pulse Rise Time  
Note 1  
Note 1  
20  
Pulse Duty Cycle  
LOAD TRANSIENT RESPONSE  
Note 2, 8  
4, 5, 6  
4, 5, 6  
Load Step 50%  
100%  
-450  
-450  
450  
200  
mV  
Amplitude  
Recovery  
µs  
4, 5, 6  
4, 5, 6  
Load Step 10% 50%  
450  
400  
mV  
µs  
Amplitude  
Recovery  
LINE TRANSIENT RESPONSE  
Note 1, 2, 3  
-500  
500  
500  
mV  
µs  
Amplitude  
Recovery  
V
Step = 80 160 Volts  
IN  
TURN-ON CHARACTERISTICS  
VIN = 16, 28, 40 Volts,. Note 4  
Overshoot  
Delay  
4, 5, 6  
4, 5, 6  
Enable 1, 2 on. (Pins 4, 12 high or open)  
250  
10  
mV  
ms  
LOAD FAULT RECOVERY  
LINE REJECTION  
Same as Turn On Characteristics.  
MIL-STD-461, CS101, 30Hz to 50KHz  
Note 1  
40  
50  
dB  
Notes to Specifications:  
1. Parameters not 100% tested but are guaranteed to the limits specified in the table.  
2. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of  
VOUT at 50% load.  
3. Line transient transition time 100µs.  
4. Turn-on delay is measured with an input voltage rise time of between 100V and 500V per millisecond.  
5. Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal.  
6. Parameter verified as part of another test.  
7. All electrical tests are performed with the remote sense leads connected to the output leads at the load.  
8. Load transient transition time 10µs.  
9. Enable inputs internally pulled high. Nominal open circuit voltage 4.0VDC.  
www.irf.com  
3
AFL2803R3S  
Block Diagram  
Figure I. Single Output  
Input  
Filter  
1
4
5
+ Input  
Output  
Filter  
+Output  
+Sense  
7
Primary  
Bias Supply  
Enable 1  
10  
Current  
Sense  
Sync Output  
Share  
Amplifier  
Control  
11 Share  
Error  
Sync Input  
Case  
6
3
2
Amp  
& Ref  
Enable 2  
FB  
12  
Sense  
Amplifier  
9
8
Sense Return  
Output Return  
Input Return  
Circuit Operation and Application Information respective output terminals at the converter.  
Figure III. illustrates a typical application.  
The AFL series of converters employ a forward switched  
mode converter topology. (refer to Figure I.) Operation of  
the device is initiated when a DC voltage whose magnitude Inhibiting Converter Output (Enable)  
is within the specified input limits is applied between pins 1  
As an alternative to application and removal of the DC  
voltage to the input, the user can control the converter  
output by providing TTL compatible, positive logic signals  
to either of two enable pins (pin 4 or 12). The distinction  
between these two signal ports is that enable 1 (pin 4) is  
referenced to the input return (pin 2) while enable 2 (pin 12)  
is referenced to the output return (pin 8). Thus, the user  
has access to an inhibit function on either side of the isolation  
barrier. Each port is internally pulled “high” so that when  
not used, an open connection on both enable pins permits  
normal converter operation. When their use is desired, a  
logical “low” on either port will shut the converter down.  
and 2. If pin 4 is enabled (at a logical 1 or open) the primary  
bias supply will begin generating a regulated housekeeping  
voltage bringing the circuitry on the primary side of the  
converter to life. Two power MOSFETs used to chop the  
DC input voltage into a high frequency square wave, apply  
this chopped voltage to the power transformer. As this  
switching is initiated, a voltage is impressed on a second  
winding of the power transformer which is then rectified and  
applied to the primary bias supply. When this occurs, the  
input voltage is shut out and the primary bias voltage  
becomes exclusively internally generated.  
The switched voltage impressed on the secondary output  
transformer winding is rectified and filtered to provide the  
converter output voltage. An error amplifier on the secondary  
side compares the output voltage to a precision reference  
and generates an error signal proportional to the difference.  
This error signal is magnetically coupled through the  
feedback transformer into the controller section of the  
converter varying the pulse width of the square wave signal  
driving the MOSFETs, narrowing the width if the output  
voltage is too high and widening it if it is too low.  
Figure II. Enable Input Equivalent Circuit  
+5.6V  
100K  
1N4148  
Pin 4 or  
Pin 12  
Disable  
290K  
2N3904  
Remote Sensing  
Connection of the + and - sense leads at a remotely locat-  
led load permits compensation for resistive voltage drop  
between the converter output and the load when they are  
physically separated by a significant distance. This  
connection allows regulation to the placard voltage at the  
point of application.When the remote sensing features is  
not used, the sense leads should be connected to their  
150K  
Pin 2 or  
Pin 8  
4
www.irf.com  
AFL2803R3S  
Internally, these ports differ slightly in their function. In use,  
a low on Enable 1 completely shuts down all circuits in the  
converter while a low on Enable 2 shuts down the secondary  
side while altering the controller duty cycle to near zero.  
Externally, the use of either port is transparent to the user  
save for minor differences in idle current. (See specification  
table).  
high level of +2.0V. The sync output of another converter  
which has been designated as the master oscillator provides  
a convenient frequency source for this mode of operation.  
When external synchronization is not required, the sync in  
pin should be left unconnected thereby permitting the  
converter to operate at its’ own internally set frequency.  
The sync output signal is a continuous pulse train set at  
550 ± 50KHz, with a duty cycle of 15 ± 5.0%. This signal is  
referenced to the input return and has been tailored to be  
compatible with the AFL sync input port. Transition times  
are less than 100ns and the low level output impedance is  
less than 50. This signal is active when the DC input  
voltage is within the specified operating range and the  
converter is not inhibited. This output has adequate drive  
reserve to synchronize at least five additional converters.  
A typical synchronization connection option is illustrated in  
Figure III.  
Synchronization of Multiple Converters  
When operating multiple converters, system requirements  
often dictate operation of the converters at a common  
frequency. To accommodate this requirement, the AFL  
series converters provide both a synchronization input and  
output.  
The sync input port permits synchronization of an AFL  
connverter to any compatible external frequency source  
operating between 500KHz and 700KHz. This input signal  
should be referenced to the input return and have a 10% to  
90% duty cycle. Compatibility requires transition times less  
than100ns, maximum low level of +0.8V and a minimum  
Figure III. Preferred Connection for Parallel Operation  
1
12  
Power  
Input  
Enable 2  
Vin  
Rtn  
Share  
+ Sense  
- Sense  
Return  
Case  
AFL  
AFL  
Enable 1  
Sync Out  
Sync In  
+ Vout  
6
1
7
Optional  
Synchronization  
Connection  
Share Bus  
12  
Enable 2  
Share  
Vin  
Rtn  
Case  
+ Sense  
- Sense  
Return  
+ Vout  
Enable 1  
Sync Out  
Sync In  
to Load  
7
6
1
12  
Enable 2  
Share  
Vin  
Rtn  
Case  
+ Sense  
- Sense  
Return  
+ Vout  
AFL  
Enable 1  
Sync Out  
Sync In  
7
6
(Other Converters)  
Parallel Operation-Current and Stress Sharing  
AFL series operating in the parallel mode is that in addition  
to sharing the current, the stress induced by temperature  
will also be shared. Thus if one member of a paralleled set  
is operating at a higher case temperature, the current it  
provides to the load will be reduced as compensation for  
the temperature induced stress on that device.  
Figure III. illustrates the preferred connection scheme for  
operation of a set of AFL converters with outputs operating  
in parallel. Use of this connection permits equal sharing of a  
load current exceeding the capacity of an individual AFL  
among the members of the set. An important feature of the  
www.irf.com  
5
AFL2803R3S  
When operating in the shared mode, it is important that for minor variations of either surface. While other available  
symmetry of connection be maintained as an assurance of types of heat conductive materials and compounds may  
optimum load sharing performance. Thus, converter outputs provide similar performance, these alternatives are often  
should be connected to the load with equal lengths of wire of  
the same gauge and sense leads from each converter should  
be connected to a common physical point, preferably at the  
load along with the converter output and return leads. All  
converters in a paralleled set must have their share pins  
connected together. This arrangement is diagrammatically  
illustrated in Figure III. showing the outputs and sense pins  
connected at a star point which is located close as possible  
to the load.  
less convenient and are frequently messy to use.  
A conservative aid to estimating the total heat sink surface  
area (AHEAT SINK) required to set the maximum case  
temperature rise (T) above ambient temperature is given  
by the following expression:  
1.43  
T  
A
HEAT SINK  
3.0  
0.85  
As a consequence of the topology utilized in the current  
sharing circuit, the share pin may be used for other functions.  
In applications requiring a single converter, the voltage  
appearing on the share pin may be used as a “current  
monitor”. The share pin open circuit voltage is nominally  
+1.00V at no load and increases linearly with increasing  
output current to +2.20V at full load. The share pin voltage  
is referenced to the output return pin.  
80P  
where  
T = Case temperature rise above ambient  
1
1  
P = Device dissipation in Watts = POUT  
Eff  
As an example, it is desired to maintain the case temperature  
of an AFL27015S at +85°C in an area where the ambient  
temperature is held at a constant +25°C; then  
Thermal Considerations  
Because of the incorporation of many innovative  
technological concepts, the AFL series of converters is  
capable of providing very high output power from a package  
of very small volume. These magnitudes of power density  
can only be obtained by combining high circuit efficiency  
with effective methods of heat removal from the die junctions.  
This requirement has been effectively addressed inside the  
device; but when operating at maximum loads, a significant  
amount of heat will be generated and this heat must be  
conducted away from the case. To maintain the case  
temperature at or below the specified maximum of 125°C,  
this heat must be transferred by conduction to an  
appropriate heat dissipator held in intimate contact with the  
converter base-plate.  
T = 85 - 25 = 60°C  
From the Specification Table, the worst case full load  
efficiency for this device is 83%; therefore the power  
dissipation at full load is given by  
1
(
)
P = 120•  
1 = 1200.205 = 24.6W  
.83  
and the required heat sink area is  
1.43  
60  
3.0 = 71 in2  
Because effectiveness of this heat transfer is dependent  
on the intimacy of the baseplate/heatsink interface, it is  
strongly recommended that a high thermal conductivity heat  
transferance medium is inserted between the baseplate  
and heatsink. The material most frequently utilized at the  
factory during all testing and burn-in processes is sold under  
A
HEAT SINK  
=
0.85  
80 24.6  
Thus, a total heat sink surface area (including fins, if any) of  
2
71 in in this example, would limit case rise to 60°C above  
ambient. A flat aluminum plate, 0.25" thick and of approximate  
2
1
dimension 4" by 9" (36 in per side) would suffice for this  
the trade name of Sil-Pad® 400 . This particular product  
application in a still air environment. Note that to meet the  
criteria in this example, both sides of the plate require  
unrestricted exposure to the ambient air.  
is an insulator but electrically conductive versions are also  
available. Use of these materials assures maximum surface  
contact with the heat dissipator thereby compensating  
1
Sil-Pad is a registered Trade Mark of Bergquist, Minneapolis, MN  
6
www.irf.com  
AFL2803R3S  
Finding a resistor value for a particular output voltage, is  
simply a matter of substituting the desired output voltage  
and the nominal device voltage into the equation and solving  
Input Filter  
The AFL2803R3S series converters incorporate a two stage  
LC input filter whose elements dominate the input load  
impedance characteristic at turn-on. The input circuit is as  
shown in Figure IV.  
for the corresponding resistor value.  
Figure V. Connection for VOUT Adjustment  
Figure IV. Input Filter Circuit  
Enable 2  
900nH  
130nH  
Share  
RADJ  
Pin 1  
Pin 2  
+ Sense  
AFL2803R3S  
- Sense  
Return  
To Load  
+ Vout  
6 µfd  
11.2 µfd  
Caution: Do not set Radj < 500Ω  
Attempts to adjust the output voltage to a value greater than  
120% of nominal should be avoided because of the potential  
of exceeding internal component stress ratings and  
subsequent operation to failure. Under no circumstance  
should the external setting resistor be made less than 500.  
By remaining within this specified range of values, completely  
safe operation fully within normal component derating limits  
is assured.  
Undervoltage Lockout  
A minimum voltage is required at the input of the converter  
to initiate operation. This voltage is set to 14 ± 0.5V. To  
preclude the possibility of noise or other variations at the  
input falsely initiating and halting converter operation, a  
hysteresis of approximately 1.0V is incorporated in this  
circuit. Thus if the input voltage droops to 13 ± 0.5V, the  
converter will shut down and remain inoperative until the  
input voltage returns to 14V.  
Examination of the equation relating output voltage and  
resistor value reveals a special benefit of the circuit topology  
utilized for remote sensing of output voltage in the AFL28XXS  
series of converters. It is apparent that as the resistance  
increases, the output voltage approaches the nominal set  
value of the device. In fact the calculated limiting value of  
output voltage as the adjusting resistor becomes very large  
Output VoltageAdjust  
In addition to permitting close voltage regulation of remotely  
located loads, it is possible to utilize the converter sense  
pins to incrementally increase the output voltage over a  
limited range. The adjustments made possible by this method  
are intended as a means to “trim” the output to a voltage  
setting for some particular application, but are not intended  
to create an adjustable output converter. These output  
voltage setting variations are obtained by connecting an  
appropriate resistor value between the +sense and -sense  
pins while connecting the -sense pin to the output return pin  
as shown in Figure V. below. The range of adjustment and  
corresponding range of resistance values can be determined  
is 25mV above nominal device voltage.  
The consequence is that if the +sense connection is  
unintentionally broken, an AFL28XXS has a fail-safe output  
voltage of Vout + 25mV, where the 25mV is independent of  
the nominal output voltage. It can be further demonstrated  
that in the event of both the + and - sense connections  
being broken, the output will be limited to Vout + 440mV.  
This 440mV is also essentially constant independent of the  
nominal output voltage. While operation in this condition is  
not damaging to the device, not at all performance  
parameters will be met.  
by use of the following equation.  
VNOM  
Radj = 100•  
VOUT - VNOM -.025  
Where VNOM = device nominal output voltage, and  
VOUT = desired output voltage  
www.irf.com  
7
AFL2803R3S  
Mechanical Outlines  
Case X  
Case W  
Pin Variation of Case Y  
3.000  
2.760  
ø 0.128  
0.050  
0.050  
0.250  
0.250  
1.000  
1.000  
Ref  
1.260 1.500  
0.200 Typ  
Non-cum  
Pin  
ø 0.040  
Pin  
ø 0.040  
0.220  
2.500  
0.220  
0.525  
2.800  
2.975 max  
0.238 max  
0.42  
0.380  
Max  
0.380  
Max  
Case Y  
Case Z  
Pin Variation of Case Y  
1.150  
0.300  
ø 0.140  
0.25 typ  
0.050  
0.050  
0.250  
0.250  
1.000  
Ref  
1.500 1.750 2.00  
1.000  
Ref  
0.200 Typ  
Non-cum  
Pin  
ø 0.040  
Pin  
ø 0.040  
0.220  
0.220  
1.750  
2.500  
0.375  
0.36  
2.800  
2.975 max  
0.525  
0.238 max  
0.380  
Max  
0.380  
Max  
Tolerances, unless otherwise specified: .XX  
.XXX  
=
=
±0.010  
±0.005  
BERYLLIAWARNING: These converters are hermetically sealed; however they contain BeO substrates and should not be ground or subjected to any other  
operations including exposure to acids, which may produce Beryllium dust or fumes containing Beryllium  
8
www.irf.com  
AFL2803R3S  
Pin Designation  
Designation  
Pin #  
1
2
+ Input  
Input Return  
Case Ground  
Enable 1  
3
4
5
Sync Output  
Sync Input  
+ Output  
6
7
8
Output Return  
Sense Return  
+ Sense  
9
10  
11  
12  
Share  
Enable 2  
Standard Microcircuit Drawing Equivalence Table  
Standard Microcircuit  
Drawing Number  
5962-99552  
IR Standard  
Part Number  
AFL2803R3S  
www.irf.com  
9
AFL2803R3S  
Device Screening  
Requirement  
MIL-STD-883 Method No Suffix  
ES  
HB  
CH  
Temperature Range  
Element Evaluation  
Non-Destructive  
Bond Pull  
-20°C to +85°C -55°C to +125°C  
-55°C to +125°C -55°C to +125°C  
MIL-PRF-38534  
2023  
N/A  
N/A  
N/A  
N/A  
Class H  
N/A  
N/A  
N/A  
Internal Visual  
Temperature Cycle  
Constant Acceleration  
PIND  
2017  
1010  
Yes  
Cond B  
500 Gs  
N/A  
Yes  
Cond C  
3000 Gs  
N/A  
Yes  
Cond C  
3000 Gs  
N/A  
N/A  
N/A  
2001, Y1 Axis  
2020  
N/A  
Burn-In  
1015  
N/A  
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C  
Final Electrical  
( Group A )  
MIL-PRF-38534  
& Specification  
MIL-PRF-38534  
1014  
25°C  
25°C  
-55°C, +25°C,  
+125°C  
N/A  
-55°C, +25°C,  
+125°C  
10%  
PDA  
N/A  
Cond A  
N/A  
N/A  
Cond A, C  
N/A  
Seal, Fine and Gross  
Radiographic  
External Visual  
Cond A, C  
N/A  
Cond A, C  
N/A  
2012  
2009  
Yes  
Yes  
Yes  
Notes:  
 Best commercial practice  
‚ Sample tests at low and high temperatures  
ƒ -55°C to +105°C for AHE, ATO, ATW  
Part Numbering  
AFL 28 03R3 S  
X
/CH  
Screening Level  
Model  
(Please refer to Screening Table)  
No suffix, ES, HB, CH  
Input Voltage  
28 = 28V  
50 = 50V  
120 = 120V  
270 = 270V  
Case Style  
W, X, Y, Z  
Output  
S = Single  
Output Voltage  
03R3 = 3.3V  
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105  
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500  
Visit us at www.irf.com for sales contact information.  
Data and specifications subject to change without notice. 03/2007  
10  
www.irf.com  

相关型号:

AFL283R3SW

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SW-CH

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

AFL283R3SW-ES

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

AFL283R3SW-HB

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

AFL283R3SW/CH

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid,
INFINEON

AFL283R3SW/CHPBF

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SW/ES

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SW/ESPBF

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SW/HB

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SW/HBPBF

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SWPBF

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON

AFL283R3SX

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid
INFINEON