SMARTSTART-HAC-C [IDEC]
IDEC SmartRelay;型号: | SMARTSTART-HAC-C |
厂家: | IDEC Corporation |
描述: | IDEC SmartRelay |
文件: | 总14页 (文件大小:615K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Features..............................................H-2
Selection Guide..................................H-3
Function Blocks.................................H-4
Specifications ....................................H-5
Connection Diagrams .....................H-10
Dimensions.......................................H-12
General Information ......................H-13
Section
Programming
• WindLGC. . . . . . . . . . . . . . . . . . .H-14
H
for more information on this product family visit
www.idec.com/smartrelay
Additional Web Resources
• New and updated product information
• Downloadable software demos & upgrades
• Part configuration tool & cross reference
• Online stock check & ordering
• IDEC field sales & distributor search
• Online literature request
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
Features
IDEC SmartRelay
IDEC SmartRelay
IDEC SmartRelay –the smart and expandable solution
Get smart with the fully programmable IDEC
SmartRelay, a compact, expandable CPU that can
replace multiple timers, relays and counters. Each
CPU houses a real-time clock and calendar, and
supports optional expansion I/O modules to
enhance your control and monitoring applications.
Program and edit using either the "smart" on-
board selection buttons and display interface, or
our even "smarter" software, WindLGC. The IDEC
SmartRelay is the ideal solution for managing
automatic lighting, access control, watering sys-
tems, pump control, or ventilation systems in fac-
tory or home automation.
HIghlights of the FL1C series
• 32-bit processor
• 130 connectable blocks
• 4 new function blocks
• 4 x12 backlight display
• Timer and counter frequency up to 2KHz
• Online monitor
• Ladder programming
• Invert of inputs saves NOT function blocks
LCD Display Panel
Display up to 48 characters as a
text message. Monitor any of the 8
basic or 26 special function blocks,
or confirm the status of the program
for troubleshooting.
Digital/Analog Inputs
(6 Digital plus 2 Digital or Analog)
Multiple inputs provide direct communication
with pushbuttons, sensors, switches, etc.
(2kHz max. on I5 and I6). (Common use I/O for
digital and analog: I7 and I8 on FL1C-H12RCE,
FL1C-B12RCE, FL1C-H12SND.) Expandable up
to 24 digital inputs.
H
Operational Control Buttons
Easy programming interface uses
only six buttons. No tools necessary.
Cursor keys can also be configured as
inputs.
Multifunction Interface
A multifunction interface makes it easy to
insert and remove the memory cartridge
that controls the circuit program. It also
supports the PC interface cable for upload-
ing and downloading data from WindLGC.
Other Key Features
• Password protection
• Daylight savings time
Digital Outputs
• UL/c-UL listed, IEC61131/VDE0631,
EMC Compliant, C-tick listed
• FM approved for Class 1, Div 2 Class
1, Zone 2 hazardous locations.
Use the outputs to control lights,
small-sized motors and solenoid
valves up to 10A. Expandable up
to 16 digital outputs.
Other Characteristics
Memory Cartridge
FL1C-PM3 is a memory cartridge
with know-how protection. Not
only is it possible to save your
program, but also to protect it
from unintended modification,
copying or deletion.
Expansion Modules
Operational Buttons
Text Display
Optional expansion I/O mod-
ules allow you to add digital
Use the selection buttons for
easy confirmation or modifi-
cation of the circuit being
displayed. The cursor keys
can be configured as inputs.
It can display messages with
background lighting up to 48
characters long from a
selection of 97 character
types.
®
input, output and LONWORKS
AS-Interface communication
modules as well as analog
inputs to your system. Just
snap-on and go – no special
software or cables required.
/
Not required for operation.
H-2
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
Selection Guide
Part Numbers
Base Module Part Number
Part Number
FL1C-H12RCE
FL1C-B12RCE
FL1C-H12SND
FL1C-H12RCA
FL1C-B12RCA
FL1C-H12RCC
FL1C-B12RCC
Rated Voltage
12/24V DC
24V DC
Input Signal
Input Type
Output Signal
With Display With Clock
Input/Output
Yes
—
DC
Relay Output
Yes
—
PNP
I7and I8 are used
for digital/analog
Transistor Source Output
Yes
Yes
—
8/4
24V AC/DC
PNP/NPN
PNP
AC/DC
Relay Output
Yes
Yes
—
100-240V AC/DC
Expansion Module Part Number
Part No.
Module
Power Voltage
Input
Output
Total I/O
FL1B-M08B2R2
FL1B-M08B1S2
FL1B-M08C2R2
FL1B-M08D2R2
FL1B-J2B2
12/24V DC
DC input
DC input
AC/DC input
AC/DC input
Analog input
–
Relay output
8 (4 in/4 out)
8 (4 in/4 out)
8 (4 in/4 out)
8 (4 in/4 out)
2 (2 in/0 out)
–
24V DC
Transistor output
Combination I/O Module
100-240V AC/DC
24V AC/DC
12/24V DC
24V AC/DC
Relay output
Relay output
Analog Input Module
–
–
_
®
FL1B-CL1C12
FL1B-CAS2
LONWORKS Communication Module*
AS-Interface Communication Module* 30V DC
_
_
* For more information see Section M, Communications & Networking.
H
Starter Kit Part Number
Part Number
Description
SMARTSTART-BAC-C
SMARTSTART-BDC-C
SMARTSTART-HAC-C
SMARTSTART-HDC-C
FL1C-B12RCC, WindLGC software, and programming cable
FL1C-B12RCE, WindLGC software, programming cable, and simulator switch
FL1C-H12RCC, WindLGC software, and programming cable
FL1C-H12RCE, WindLGC software, programming cable, and simulator switch
Accessories
Part Number
Description
Note
FL1C-PM3
Memory Cartridge
Memory cartridge with know-how protection
CD w/Online Manual
FL9Y-LP1CDW
FL1A-PC1
Programming Software: WindLGC Ver. 4
PC Interface Cable
Connection of SmartRelay to PC
BAA1000
35MM DIN Rail
Mounting Clips
Aluminum, 1m/3.28ft
BNDN1000
BNL6
MT-101
Memory Cartridge Removal Tool
Direct Mounting Slides
8pt simulator switch
FL1B-PSP1
FL1B-Y1371-SW8
FL9Y-B827
FC4A-USB
used with 12, 24V DC base module only
FL1C user’s manual
USB/RS232 converter
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-3
Function Blocks
IDEC SmartRelay
Function Blocks
General Function Blocks
Special Function Blocks
• On-delay
1
2
3
4
• AND
• Operating hours counter
R
&
R
En
Trg
Par
En
Ral
Trg
Q
h
Q
Q
Series connection of
normally open contacts
Mi
Mn
Q
Q
Q
Q
Ral
Par
T
OT
Q
• Off-delay
• Asynchronous pulse generator
Trg
R
Trg
R
Par
• AND (Edge)
EN
En
Inv
AND
Q
1
2
3
4
I1
I2
I3
Inv
Q
T
TH
TL
&
Par
• On-/Off-delay
I4
Q
• Random generator
Trg
Trg
Par
Cycle
1
2
3
4
5
6
7
8
9
10
Trg
Q
Q
Edge detection with
edge evaluation (pos. edge)
En
Q
Q
Q
TH
TL
Par
T
Starts
TH
TL
• Retentive on-delay
Trg
R
Q
• Frequency trigger
• NAND
Trg
R
Fre
fa=5Hz
fa=3Hz
Q
Q
Fre
Par
1
2
3
4
G T
-
Q
1s
1s
&
T
T
Par
Q
• Latching relay
Parallel connection of
normally closed contacts
• Analog trigger
RS
S
R
Q
S
1000
SW
SW
A/1 or
R
Ax
0
Q
Q
Par
Par
A/2
Q
• NAND (Edge)
• Current impulse relay
NAND
Trg
Trg
• Analog comparator
I1
I2
I3
1000
1
S
R
Par
S
R
Q
Q
Q
A/1
0
&
2
3
4
1000
RS
I4
Ax
Ay
Par
Q
A/2
0
Q
1000
200
0
Cycle
1
2
3
4
5
6
7
8
9
10
H
• Interval time-delay relay/
Pulse output
A/1-A/2
Edge detection with
edge evaluation (pos. edge)
Q -200
tor ?=200
Trg
Trg
Q
• Stairwell light switch
Par
T
• OR
Trg
Trg
Par
• Edge-triggered interval
time-delay relay
Q
1
Q
1
1
T
T
Starts
2
3
4
1s
Q
Q
Q
Q
15s
Trg
Trg
Parallel connection of
normally open contacts
R
Q
Q
• Dual-function switch
Q
Par
Trg
T
Trg
R
Par
TL
TL
TStarts
Q
TIL
T1
T
Q
Q
• Seven-day time switch
• NOR
Sa
12
Su
12 20
1
SaꢀSu
No1
ONꢀ12:00
20
No1
No2
No3
OFF 20:00
2
3
4
Su
• Message texts
ONꢀ 8:00
No2
Q
8
22
Series connection of
normally closed contacts
OFF 22:00
En
P
Par
12 20
8
20
• Twelve-month time switch
MM.DDt
Fed. Mar. Apr.
MM
DD
No 02.25
• Softkey
No 04.15
Q
Q
Q
• XOR
No
EN
25
25
En
Switch
Q
=
1
Q
Par
• Up/down counter
1
2
R
Cnt
R
Cnt
Double changeover contact
• Analog amplifier
Dir
Dir
3
2
Par
1
Par
Ax
0
Q
Q
Q
Par
• NOT
• Analog differential trigger
o
n
• Shift register
1
OFF=On+?
1
AX
Q
Ax
In
Trg
In
Connection of closed contact
Trg
Q
Q
Q
Par
OFF=On+?
Dir
Dir
AX
Q
S1
S2
S3
S4
S5
S6
S7
S8
0
0
0
0
1
1
0
0
1
0
0
0
0
1
1
0
0
1
0
0
0
0
1
1
1
0
1
0
0
0
0
1
1
1
0
1
0
0
0
0
0
1
1
0
1
0
0
0
1
1
0
1
0
0
0
1
Par
S4=Q (Example)
• Analog value monitoring
En
Ax
Par
En
Aen+?
Aen
AeAn-?X
Shift Up
Shift Down
Q
H-4
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
Specifications
Specifications
Item
Specifications
Compliant Standards
Dimensions (W x H x D)
Weight
72 x 90 x 55 mm
Approx. 190g
—
—
Horizontal
Vertical
0 to +55°C
Operating
temperature
Cold: IEC60068-2-1
Hot: IEC60068-2-2
0 to +55°C
Storage temperature
Relative humidity
Pressure
-40 to +70°C
—
10 to 85%
IEC60068-2-30
795 to 1080 hPa
Free from corrosive gases
IP20
—
—
Corrosion immunity
Degree of protection
5 to 9Hz (amplitude: 3.2mm)
9 to 150Hz (acceleration: 10m/s )
Vibration resistance
IEC60068-2-6
2
2
Shock resistance
Dropping
IEC60068-2-27
IEC60068-2-31
IEC60068-2-32
EN55011
150 m/s
50 mm (Drop height)
Free fall (packaged)
Emission
1 m
Class B Group 1
—
Emitted interference
EN50081-2, EN50082-2
8kV Air Discharge
6kV Contact Discharge
Electrostatic discharge
IEC61000-4-2
Electromagnetic fields
Burst pulses
10V/m
IEC61000-4-3
IEC61000-4-4
2KV (Supply and Signal Lines)
H
0.5kV(Power Lines): Symmetrical
1kV (Power Lines): Asymmetrical
Energy carriers single pulse (surge)
Communication cable
IEC61000-4-5
—
2
2 x 1.5 mm ,
1 x 0.5 to 2.5 mm
2
Base Module Specifications
FL1C-H12RCE
FL1C-H12SND
FL1C-H12RCA
FL1C-B12RCA
24V AC/DC
FL1C-H12RCC
Base Module Part Number
FL1C-B12RCE
–
FL1C-B12RCC
Rated voltage
12/24V DC
24V DC
100-240V AC/DC
20.4V-26.4V AC
20.4V-28.8V DC
85-265 AC
Allowable Voltage Range
Rated Frequency
10.8-28.8V DC
—
20.4-28.8V DC
—
100-253 V DC
47-63Hz
50/60Hz (47-63Hz)
10-40 mA (100V AC)
10-25 mA (240V AC)
5-25mA (100V DC)
5-15mA (240V DC)
30-140 mA (12V DC)
20-75 mA (24V DC)
40-110 mA (24V AC)
20-75 mA (24V DC)
Input Current
30-55 mA (24V DC)
—
Allowable Momentary
Power Interruption
2 ms (12V DC)
5 ms (24V DC)
10 ms (100V AC)
20 ms (240V AC)
5 ms
1.1-4.6W (100V AC)
2.4-6.0W (240V AC)
0.5-2.9W (100V DC)
1.2-3.6W (240V DC)
0.3-1.7W (12V DC)
0.4-1.8W (24V DC)
0.9-2.7W (24V AC)
0.4 to1.8W (24V DC)
Power Consumption
0.7-1.3W (24V DC)
Reverse Polarity Protection
Backup Duration
Yes
Yes
—
—
—
80h at 25°C
2s / day maximum
80h at 25°C
2s / day maximum
80h at 25°C
2s / day maximum
Clock Accuracy
—
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-5
Specifications
IDEC SmartRelay
Specifications con’t
FL1C-H12RCE
FL1C-B12RCE
DC
FL1C-H12SND
FL1C-H12RCA
FL1C-B12RCA
AC/DC
FL1C-H12RCC
FL1C-B12RCC
AC/DC
Base Module Part Number
–
Input Signal
DC
Input Points
8 (I1-I8)
8 (I1-I8)
8 (I1 - I8)
—
8 (I1-I8)
—
Analog Input Points
Fast Inputs
2 (I7, I8)*
2 (I7, I8)*
2 (I5, I6) Max 2KHz**
2 (I5, I6) Max 2 KHz**
—
—
0 to10V DC (maximum
0 to 10V DC (maximum
rated voltage: 28.8V DC)
Analog Input Voltage Range
Rated Input Voltage
—
—
rated voltage: 28.8V DC)
12/24V DC
24V DC
24V AC/DC
100-240V AC/DC
85-253V AC, 100-253 VDC
0-26.4V AC
0-28.8V DC
Allowable Voltage Range
10.8-28.8V DC
20.4-28.8V DC
Isolation
Not Isolated
< 5V DC
Not Isolated
< 5V DC
Not Isolated
< 5V AC/DC
> 12V AC/DC
Not Isolated
Turn OFF Voltage
< 40V AC, < 30 VDC
> 79V AC, > 79VDC
Turn ON Voltage
Operating
Range
> 8V DC
> 8V DC
< 1.0 mA (I1-I6)
< 0.05 mA (I7-I8)
< 1.0 mA (I1-I6)
< 0.05 mA (I7-I8)
Turn OFF Current
< 1.0 mA
> 2.5 mA
< 0.03 mA
> 0.08 mA
> 1.5 mA (I1-I6)
> 0.1 mA (I7-I8)
> 1.5 mA (I1-I6)
> 0.1 mA (I7-I8)
Turn ON Current
1.5ms (Typ.) (I1-14)
<1.0ms (I5, I6)
300ms Typ. (I7, I8)
1.5ms (Typ.) (I1-14)
<1.0ms (I5, I6)
300ms Typ. (I7, I8)
Turn ON Time
1.5 ms (Typ.)
50 ms (Typ.)
Turn OFF Time
Wire Length
1.5ms (Typ.)
100m
1.5 ms (Typ.)
100m
15 ms (Typ.)
100m
50 ms (Typ.)
100m
Transistor Source Out-
put
H
Output Signal
Relay Output
Relay Output
Relay Output
Output Type
Isolation
4NO contacts
Isolated
4 points
4NO contacts
Isolated
4NO contacts
Isolated
Not Isolated
Dielectric Strength (between power/ 2,500V AC/1 minute
2,500V AC/1 minute
500V DC/1 minute
2,500V AC/1 minute
500V DC/1 minute
—
input terminal and output terminals)
500V DC/1 minute
Ext. power supply
20.4-28.8V DC
Output Voltage
—
—
—
Resistive Load
Resistive Load
Resistive Load
10A at 12/24V AC/DC
10A at 100/120V AC
10A at 230/240V AC
Inductive Load
10A at 12/24V AC/DC
10A at 100/120V AC/DC
10A at 230/240V AC/DC
Inductive Load
10A at 12/24V AC/DC
10A at 100/120V AC
10A at 230/240V AC
Inductive Load
Maximum Load Current
0.3A
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V
2A at 12/24V AC/DC
3A at 100/120V AC/DC
3A at 230/240V AC/DC
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V AC
External fuse
16A maximum
Internal current
External fuse
16A maximum
External fuse
16A maximum
Short Circuit Protection
Minimum Switching Load
Initial Contact Resistance
limiting circuit: 1A
10 mA, 12V DC
—
—
10 mA, 12V DC
10 mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
100 mΩ maximum
(at 1A, 24V DC)
100 mΩ maximum
(at 1A, 24V DC)
10,000,000 operations
10,000,000 operations
min (no load, 10Hz)
10,000,000 operations
Mechanical Life
Electrical Life
—
—
minimum (no load, 10Hz)
minimum (no load, 10Hz)
100,000 operations mini-
mum (rated load 10A,
1,800 operations/hour)
100,000 operations min
(rated load 10A, 1,800
operations/hour)
100,000 operations mini-
mum (rated load 10A,
1,800 operations/hour)
Mechanical Load
Electrical Load
10 Hz
—
—
10 Hz
—
10 Hz
—
10 Hz
10 Hz
0.5 Hz
Resistive Load/Lamp Load
Inductive Load
2 Hz
0.5 Hz
2 Hz
0.5 Hz
2 Hz
0.5 Hz
* Input terminals 17 and 18 are used for digital and analog inputs.
** When selecting frequency trigger function.
H-6
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
Specifications
Specifications con’t
Combination I/O Module
FL1B-M08B1S2 FL1B-M08D2R2
Analog Input Module
FL1B-J2B2
12/24V DC
10.8-15.6V DC
20.4-28.8V DC
Expansion I/O Part Number
FL1B-M08B2R2
12/24V DC
FL1B-M08C2R2
100-240V AC/DC
85-265V AC
100-253V DC
Rated voltage
24V DC
20.4-28.8V DC
—
24V AC/DC
20.4V-26.4V AC
20.4V-28.8V DC
Allowable Voltage Range
Rated Frequency
10.8-28.8V DC
—
47-63Hz
50/60Hz (47-63Hz)
—
10-30 mA (100V AC)
10-20 mA (240V AC)
5-15mA (100V DC)
5-10mA (240V DC)
10 ms (100V AC)
20 ms (240V AC)
30-140 mA (12V DC)
22-75 mA (24V DC)
40-110 mA (24V AC)
20-75 mA (24V DC)
Input Current
30-45 mA (24V DC)
—
25-50mA
Allowable Momentary
Power Interruption
2 ms (12V DC)
5 ms (24V DC)
5 ms
5 ms
1.1-3.5W (100V AC)
2.4-4.8W (240V AC)
0.5-1.8W (100V DC)
1.2-2.4W (240V DC)
0.3-1.7W (12V DC)
0.4-1.8W (24V DC)
0.9-2.7W (24V AC)
0.4 to 1.8W (24V DC)
0.3-0.6W (12V DC)
0.6-1.2W (24V DC)
Power Consumption
0.8-1.1W (24V DC)
Reverse Polarity Protection
Input Signal
Input Points
Yes
DC
4
Yes
DC
4
—
AC/DC
4
—
AC/DC
4
Yes
Analog
—
Analog Input Points
—
—
—
—
2
76 kΩ (0-10V DC)
Input Impedance
—
—
—
—
—
—
155-250 Ω (0-20mA DC)
0-10V DC (28.8V max)
0-20mA (40mA max)
Analog Input Range
Digital Resolution
Rated Input Voltage
—
12/24V DC
—
24V DC
—
10 bits (0-1000)
—
24V AC/DC
100-240V AC/DC
10.8-15.6V DC
0-26.4V AC
85-253V AC
Allowable Voltage Range
Isolation
20.4-28.8V DC
Not Isolated
< 5V DC
—
20.4-28.8V DC
0-28.8V DC
100-253V DC
Not Isolated
Not Isolated
< 5V AC/DC
Isolated
< 40V AC
< 30V DC
> 79V AC
> 79V DC
< 0.3 mA
> 0.08 mA
50 ms (Typ.)
50 ms (Typ.)
Not Isolated
—
Turn OFF Voltage < 5V DC
Turn ON Voltage > 8V DC
Operating
Range
H
> 8V DC
> 12V AC/DC
—
Turn OFF Current < 1.0 mA
Turn ON Current > 1.5 mA
< 1.0 mA
> 1.5 mA
1.5 ms
< 1.0 mA
> 2.5 mA
1.5 ms (Typ.)
15 ms (Typ.)
—
—
—
—
Turn ON Time
Turn OFF Time
1.5ms
1.5ms
1.5 ms
Analog Value Conversion
Interval
—
—
—
50ms
10m (twisted-pair
shielded cable)
Wire Length
100m
100m
100m
100m
Transistor Source
Output
Output Signal
Relay Output
Relay Output
Relay Output
—
Output Type
Isolation
4NO contacts
Isolated
4 points
Not Isolated
4NO contacts
Isolated
4NO contacts
Isolated
—
—
Dielectric Strength
2,500V AC/1 minute
500V DC/1 minute
2,500V AC/1 minute
500V DC/1 minute
2,500V AC/1 minute
500V DC/1 minute
2,500V AC/1 minute
500V DC/1 minute
(between power/ input termi-
nal and output terminals)
—
—
Ext. power supply
20.4-28.8V DC
Output Voltage
—
—
—
Resistive Load
Resistive Load
Resistive Load
10A at 12/24V AC/DC
10A at 100/120V AC
10A at 230/240V AC
Inductive Load
5A at 12/24V AC/DC
10A at 12/24V AC/DC
5A at 100/120V AC/DC 10A at 100/120V AC
5A at 230/240V AC/DC 10A at 230/240V AC
Maximum Load Current
0.3A
—
Inductive Load
2A at 12/24V AC/DC
Inductive Load
2A at 12/24V AC/DC
2A at 12/24V AC/DC
3A at 100/120V AC
3A at 230/240V
3A at 100/120V AC/DC 3A at 100/120V AC
3A at 230/240V AC/DC 3A at 230/240V AC
External fuse required Internal current
External fuse
External fuse
Short Circuit Protection
Minimum Switching Load
Initial Contact Resistance
—
—
—
16A max
limiting resistor: 1A
—
16A maximum
16A maximum
10 mA, 12V DC
10 mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
10,000,000 operations
min (no load, 10Hz)
100,000 operations mini- 100,000 operations
mum (rated load 1,800 (rated resistive load
operations/hour)
10 mA, 12V DC
100 mΩ maximum
(at 1A, 24V DC)
10,000,000 operations
(no load)
100 mΩ maximum
—
—
(at 1A, 24V DC)
10,000,000 operations
(no load)
Mechanical Life
Electrical Life
—
—
100,000 operations
(rated resistive load
1,800 operations/hr)
—
1,800 operations/hr)
Mechanical Load
Electrical Load
Resistive Load/Lamp Load
Inductive Load
10Hz
—
2Hz
—
10 Hz
—
2 Hz
0.5 Hz
10Hz
—
2Hz
—
—
—
—
10Hz
10Hz
0.5Hz
0.5Hz
0.5Hz
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-7
Specifications
IDEC SmartRelay
Specifications con’t
Operating Temperature
0 to 55°C (no freezing)
Operating Humidity
Storage Temperature
Storage Humidity
10 to 85% RH (no condensation)
–40 to +70°C (no freezing)
10 to 85% RH (no condensation)
24V AC/DC
Rated Power Voltage
Allowable Voltage Range
Current Draw
20.4 to 26.4V AC, 20.4 to 28.8V DC
33 mA max.
500V DC, 1 minute
(between power terminal and dead parts)
Dielectric Strength
10 MΩ minimum
Insulation Resistance
Electrostatic
(500V DC megger between power terminal and dead parts)
8 kV air discharge
6 kV contact discharge
Discharge
EMC
Burst Pulses
2 kV (power terminal)
5 to 9 Hz, amplitude 3.5 mm
9 to 150 Hz, 9.8 m/s
Vibration Resistance
2
2
Shock Resistance
Dimensions
150 m/s
35.5W × 90H × 58D mm
DIN rail or panel surface
IP20
Mounting Style
Degree of Protection
Terminal Style
Weight
Screw-cage clamp terminal
85g
H
®
Communication System
Transceiver
LON system
FTT-10A
Topology
Bus topology, free topology
78 kbps
Transmission Rate
Neuron Chip
TMPN3120FE5M (Toshiba)
20 MHz
CPU Clock Frequency
Bus topology: 1400m
(only FTT-10A transceiver, using Level 4 AWG22 cable)
Free topology: 500m total, 400m between nodes
(when using Level 4 AWG22 cable)
Transmission Distance
SNVT_obj_request: (Quantity 1)
SNVT_switch: (Quantity 14)
Request object mode
Switch light, alarm, window
contact, free inputs/outputs
Input
Network
Variable
SNVT_occupancy: (Quantity 2)
SNVT_temp_p: (Quantity 1)
SNVT_lux: (Quantity 1)
Occupancy
Room temperature (°C)
Brightness - lighting level (lux)
Position (%)
SNVT_lev_percent: (Quantity 6)
SNVT_obj_status: (Quantity 1)
Output object status
Switch light, alarm, window
contact, free inputs/outputs
SNVT_switch: (Quantity 8)
SNVT_occupancy: (Quantity 2)
SNVT_tod_event: (Quantity 2)
Output
Network
Variable
Occupancy
Scheduler program
Just current state
Configuration
Property
SCPTmaxSendTime:
Send heartbeat (Q5 to Q16)
H-8
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
Specifications
Specifications con’t
Operating Temperature
Storage Temperature
Relative Humidity
0 to 55°C
–40 to +70°C
10 to 85% (no condensation)
30 VDC (26.5VDC to 31.6VDC)
Yes
Rated As-interface Voltage
Reverse Polarity Protection
Current Draw
70 mA max.
Electrostatic
Discharge
8 kV air discharge (IEC61000-4-2)
4 kV contact discharge
Electromagnetic filed
EMC
Filed strength 10V/m (IEC61000-4-3)
First Transient
Burst Pulse
1kV (criteria A) (IEC61000-4-4)
1kV (criteria B)
Radiated Emission
Class A (EN55011)
5 to 9 Hz, amplitude 3.5 mm
9 to 150 Hz, 9.8 m/s
Vibration Resistance
2
2
Shock Resistance
Slave type
147 m/s 11ms (X, Y, Z each direction 3 times)
Standard slave
I/O code 7
I/D code F
I/D2 code F
Profile
Degree of Protection
Terminal Style
Applicable wire
Instruction
IP20
Screw terminal (tightening torque: max. 0.5Nm)
2
0.5 to 1.5mm
H
on a 35mm mounting rail according to DIN EN50022/wall mounting
Dimensions
36W × 90H × 58D mm
Weight
75g
Logic Assignments
IDEC SmartRelay System
AS-Interface System
Inputs:
In
Output data bits:
D0
D1
I
n+1
I
D2
n+2
I
D3
n+3
Outputs:
Input data bits:
Q
D0
D1
D2
D3
n
Q
n+1
Q
2
n+
Q
n+3
“n” depends on the plug-in position of the expansion module relative to the IDEC SmartRelay CPU. It indicates the number of
the input or output in the IDEC SmartRelay program code.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-9
General Information
IDEC SmartRelay
Connection Diagrams
Inputs (CPU)
FL1C-H12RCE/-B12RCE/H12SND
The inputs of these devices are
non-isolated and therefore require
the same reference potential
(ground) as the power supply.
With the FL1B-H12RCE/-B12RCE
and FL1B-H12SND you can tap
the analog signal between the
supply voltage and ground
L+ M I1 I2 I3 I4
I5 I6 I7 I8
Input 8xDC
FL1C-H12RCC/-B12RCC
The inputs of these devices are
arranged in 2 groups with 4
inputs each. Different phases are
only possible between, but not
within the blocks.
L
N
I1 I2 I3 I4
I5 I6 I7 I8
H
Input 8xAC/DC
Current safety regulations (VDE 0110, ... and IEC 61131-2, ... as well as UL and CSA)
do not permit the connection of different phases to one input group (I1-4 or I5-8) of an
AC model or on the inputs of one digit al module.
FL1C-H12RCA/-B12RCA
PNP
Sensor Sensor
NPN
Sensor Sensor
–
+
–
+
+
+
–
NPN
PNP
PNP
NPN
–
24V
DC
24V
DC
0V
+V
FL1C-H12RCA
FL1C-H12RCA
H-10
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
General Information
Connection Diagrams con’t
Outputs
Connecting the load to the FL1C-*12R**:
Protection with automatic circuit beaker (max. 16A) if desired
Connecting the load to a IDEC SmartRelay
with transistor outputs (FL1C-H12SND):
H
Analog Input Expansion Module
FL1B-J2B2
Grounding terminal
for connecting
ground and shielding
of the analog
measuring line
Ground
Cable shielding
DIN rail
Voltage
measurement
Current
measurement
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-11
General Information
IDEC SmartRelay
Dimensions
Base Module
Expansion Module
L1
N
I1
I2
I3
I4
I5
I6
I7
I8
L+
M
11 12 13 14
RUN/STOP
1
2
1
2
Q1
Q2
1
2
1
2
Q3
Q4
Q1
Q2
Q3
Q4
53mm
36mm
55
72
®
LONWORKS /AS-Interface Communication Module
58
53
35.5
L+
M
24VAC/DC
RUN/STOP
H
X
3
2
4
FL1B-CL1C12
Service
A
B
LON
Mounting Hole Layout
53mm
35.5mm
CPU Module
Expansion Module
Expansion Module
Expansion Module
2-ø4
Mounting Holes
35.5mm
H-12
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC SmartRelay
General Information
General Information
Maximum Setup
• Maximum Setup of IDEC SmartRelay Without Analog
Inputs FL1C-H12RCA/B12RCA/H12RCC/B12RCC
(CPU, 4 digital modules and 4 analog modules)
• Maximum Setup of IDEC SmartRelay With Analog
Inputs FL1C-H12RCE/B12RCE/H12SND
(CPU, 4 digital modules and 3 analog modules)
I1. . . . . . . . I8 I9...I12
I13...I16
I17...I20
I21...I24
I1.....I6, I7, I8 I9...I12
AI1, AI2
I13...I16
I17...I20
I21...I24
AI1, AI2 AI3, AI4 AI5, AI6 A17, A18
FL1B-M08 FL1B-M08 FL1B-M08 FL1B-M08 J2B2 J2B2 J2B2 J2B2
Q5...Q8 Q9...Q12 Q13...Q16
AI3, AI4 AI5, AI6 AI7, AI8
FL1B-
FL1B-
FL1B-
FL1B-
M08B2R2 FL1B-
J2B2
CPU
Q1,,,Q4
CPU
Q1,,,Q4
M08B2R2 M08B2R2 M08B2R2
FL1B-
J2B2
FL1B-
J2B2
Q5...Q8
Q9...Q12
Q13...Q16
• High-speed/Optimal Communication Performance
For optimal and high-speed communication performance between the IDEC SmartRelay and the various modules, we recommend you install the digital
modules first, then the analog modules (see example above).
Setup With Different Voltage Classes
• Rules
Digital modules can only be connected to devices of the same voltage class.
• Overview: Connecting an expansion module to IDEC SmartRelay
Expansion Modules
CPU
M08B2R2 M08B1S2 M08D2R2 M08C2R2
J2B2
AS-i/LON
FL1C-H12RCE
FL1C-H12SND
FL1C-H12RCA
FL1C-H12RCC
FL1C-B12RCE
FL1C-B12RCA
FL1C-B12RCC
X
X
X
–
X
X
–
X
X
X
–
X
X
–
X
X
X
–
X
X
–
–
–
–
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
H
• Overview: Connecting an additional expansion module to an expansion module
Additional Expansion Modules
Expansion Module
M08B2R2 M08B1S2 M08D2R2 M08C2R2
J2B2
CAS2
CL1C12
FL1B-M08B2R2
X
X
X
–
X
X
–
X
X
X
–
X
X
–
X
X
X
–
X
X
–
–
–
–
X
–
–
–
X
X
X
X
X
X
–
X
X
X
X
X
–
–
X
X
X
X
X
–
–
FL1B-M08B1S2
FL1B-M08D2R2
FL1B-M08C2R2
FL1B-J2B2
FL1B-CAS2 AS-Interface
FL1B-CL1C12 LONWORKS
®
I/O Configuration with LONWORKS Communication Module
Module Combination and Allocation Numbers
®
1. Maximum number of I/O points using LONWORKS communication module
FL1C-H12RCC
FL1B-CL1C12
Digital Input:I
1
2
3
4
5
6
7
8
9
1
5
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Analog Input:AI
Digital Output:Q
2
6
3
7
4
8
5
9
6
7
8
1
2
3
4
10 11 12 13 14 15 16
2. Using analog inputs on the base module
®
1. The LONWORKS communication module can
be used with any base module and expansion I/
O module.
FL1C-H12RCE
FL1B-CL1C12
Digital Input:I
1
1
1
2
2
2
3
4
5
6
6
7
7
8
8
9
3
5
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Analog Input:AI
Digital Output:Q
4
6
5
7
6
8
7
9
8
®
2. The LONWORKS communication module must
3
4
10 11 12 13 14 15 16
be mounted at the right-most position of the
row.
3. I/O numbers are automatically allocated start-
ing with the base module.
3. Using expansion I/O modules
FL1C-H12RCE
FL1B-M08B2R2
FL1B-CL1C12
Digital Input:I
1
1
1
2
2
2
3
4
5
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
Analog Input:AI
Digital Output:Q
3
4
5
9
6
7
8
3
4
5
6
7
8
10 11 12 13 14 15 16
FL1B-J2B2
®
Base module, LONWORKS communication module, Combination I/O module, Analog input module
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
H-13
Programming Software
IDEC SmartRelay
WindLGC Programming Software
WindLGC is the exclusive programming software for the IDEC
SmartRelay using Windows®. Edit, save, and print out your
programs.
WindLGC Ver. 4 Features:
• Ladder programming
• Online Monitor
• Program Comparison
• Time Simulation
• Simplified connection of the functions
• Programs can be saved in PDF or JPG format
Just click the function blocks you need and link function blocks for
easy wiring. Devise complicated circuits using the convenient func-
tions of WindLGC.
WindLGC system requirements:
To configure IDEC SmartRelay FL1C series, you must upgrade to
WindLGC version 4.0.
• OS: Windows95/98/ME/NT/2000/XP
• Monitor Recommendation: Display
more than 800 x 600 dots and 256 col-
ors
• CPU recommendation: Pentium
266MHz or higher
• Memory: 64MB or more
Free download service, if upgrading
from WindLGC Version 3 to Version 4,
available at www.idec.com/usa
• RAM recommendation: 128MB
• Hard disk space: 90MB or more for
installing WindLGC software.
H
Program Comparison
Simulation Mode/Online Monitor
Ladder Programming
H-14
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
相关型号:
©2020 ICPDF网 联系我们和版权申明