RTE-B1AD24 [IDEC]
Analog Timers;型号: | RTE-B1AD24 |
厂家: | IDEC Corporation |
描述: | Analog Timers |
文件: | 总7页 (文件大小:1131K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
RTE
Timers
RTE Series — AnalogTimers
Key features:
• 20 time ranges and 10 timing functions
• Time delays up to 600 hours
• Space-saving package
• High repeat accuracy of 0ꢀ2ꢁ
• ON and timing OUT LED indicators
• Standard 8- or 11-pin and 11-blade termination
• 2 form C delayed output contacts
• 10A Contact Rating
Certꢀ Noꢀ E9950913332316 (EMC, RTE)
Certꢀ Noꢀ BL960813332355 (LVD, RTE)
UL Listed
File Noꢀ E66043
General Specifications
Contact Ratings
Operation System
Solid state CMOS Circuit
2 Form C, DPDT
(Delay output)
Contact Configuration
Operation Type
Multi-Mode
Allowable Voltage /
Allowable Current
Time Range
0ꢀ1sec to 600 hours
240V AC, 30V DC / 10A
1800 cycles per hour
Pollution Degree
Over voltage category
2 (IE60664-1)
Maximum Permissible
Operating Frequency
III (IE60664-1)
AF20
AD24
D12
100-240V AC(50/60Hz)
Resistive
10A 240V AC, 30V DC
7A 240V AC, 30V DC
Rated Operational Voltage
Voltage Tolerance
24V AC(50/60Hz)/24V DC
Rated Inductive
12V DC
Load
Horse Power
AF20
AD24
D12
85-264V AC(50/60Hz)
1/6 HP 120V AC, 1/3 HP 240V AC
Rating
20ꢀ4-26ꢀ4V AC(50/60Hz)/21ꢀ6-26ꢀ4V DC
10ꢀ8-13ꢀ2V DC
Electrical
Life
500,000 opꢀ minimum (Resistive)
50,000,000 opꢀ minimum
Mechanical
Input off Voltage
Rated Voltage x10ꢁ minimum
-20 to +65ºC (without freezing)
-30 to +75ºC (without freezing)
35 to 85ꢁRH (without condensation)
80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)
100msec maximum
Ambient Operating Temperature
Ambient Storage and Transport Temperature
Relative Humidity
Atmospheric Pressure
Reset Time
Repeat Error
0ꢀ2ꢁ, 20msecꢂ
Voltage Error
0ꢀ2ꢁ, 20msecꢂ
Temperature Error
Setting Error
0ꢀ5ꢁ, 20msecꢂ
10ꢁ maximum
Insulation Resistance
100MΩ minimum (500V DC)
Between power and output terminals: 2000V AC, 1 minute
Between contacts of different poles: 2000V AC, 1 minute
Between contacts of the same pole:1000V AC, 1 minute
10 to 55Hz amplitude 0ꢀ5mm2 hours in each of 3 axes
Operating extremes: 98m/sec2 (10G)
Damage limits: 490m/sec2 (50G)
3 times in each of 3 axes
Dielectric Strength
Vibration Resistance
Shock Resistance
Degree of Protection
IP40 (enclosure) (IEC60529)
TYPE
RTE-P1, -B1
120V AC/60Hz 6ꢀ5VA
240V AC/60Hz 11ꢀ6VA
RTE-P2, -B2
6ꢀ6VA
AF20
Power Consumption
(Approx.)
11ꢀ6VA
24V AC 60Hz/DC
D12
3ꢀ4VA/1ꢀ7W
3ꢀ5VA/1ꢀ7W
1ꢀ6W
1ꢀ6W
Mounting Position
Dimensions
Free
RTE-P1, P2
RTE-B1, B2
40Hx 36W x 77ꢀ9D mm
40Hx 36W x 74ꢀ9D mm
ꢂFor the value of the error against a preset
time, whichever the largest, appliesꢀ
RTE-P1
87g
RTE-P2
89g
RTE-B1, -B2
85g
Weight (Approx.)
1705151136
www.IDEC.com
944
RTE
Timers
Part Numbering Guide
RTE series part numbers are composed of 4 part number codesꢀ When ordering a RTE series part, select one code from each categoryꢀ
Example: RTE-P1AF20
RTE
—
P
1
AF20
j Series
k Terminal
Style
l Function
Group
m Input Voltage
Part Numbers: RTE Series
Description
Part Number Code
Remarks
RTE series
Pin
RTE
P
For internal circuits, see next pageꢀ
j Series
Select one onlyꢀ
k Terminal Style
Blade
B
ON-delay, interval, cycle OFF, cycle ON
1
Each function group has different timing functionsꢀ
See page 940ꢀ
l Function Group
m Input Voltage
ON-delay, cycle OFF, cycle ON, signal ON/
OFF delay, OFF-delay, one-shot
2
100 to 240V AC(50/60Hz)
24V AC(50/60Hz)/24V DC
12V DC
AF20
AD24
D12
Part Numbers
Power Triggered
Start Input Triggered
Voltage
8-Pin
Blade
11-Pin
Blade
12V DC
RTE-P1D12
RTE-P1AD24
RTE-P1AF20
RTE-B1D12
RTE-B1AD24
RTE-B1AF20
RTE-P2D12
RTE-P2AD24
RTE-P2AF20
RTE-B2D12
RTE-B2AD24
RTE-B2AF20
24V AC/DC
100-240V AC
Time Range Determined by Time Range Selector and Dial Selector
Dial
Second
Minute
Hour
0 - 1
0 - 3
0 - 10
0 - 30
0 - 60
0ꢀ1 sec - 1 sec
1ꢀ2 sec - 1 min
1ꢀ2 min - 1 hr
12 min - 10 hr
0ꢀ1 sec - 3 sec
3ꢀ6 sec - 3 min
3ꢀ6 min - 3 hr
36 min - 30 hr
0ꢀ2 sec - 10 sec
12 sec - 10 min
12 min - 10 hr
2 hr - 100 hr
0ꢀ6 sec - 30 sec
36 sec - 30 min
36 min - 30 hr
6 hr - 300 hr
1ꢀ2 sec - 60 sec
1ꢀ2 min - 60 min
1ꢀ2 hr - 60 hr
12 hr - 600 hr
10 Hours
1705151136
800-262-IDEC (4332) • USA & Canada
945
RTE
Timers
Timing Diagrams
RTE-P1, -B1
RTE-P1
RTE-B1
1ꢀ RTE-B1: Do not apply voltage to terminals #2, #5 & #8ꢀ
1
3
6
2ꢀ IDEC sockets are as follows: RTE-P1: SR2P-06ꢂ pin type socket,
RTE-B1: SR3B-05ꢂ blade type socket, (ꢂ-may be followed by suffix
letter A,B,C or U)ꢀ
2
5
4
5
4
6
7
3
2
7
8
9
8
1
A
B
(~/+
)
(~/-)
(~/
+
)
(~/-)
A: ON-Delay 1 (power start)
Set timer for desired delay, apply power to coilꢀ Contacts transfer after preset time has elapsed, and
remain in transferred position until timer is resetꢀ Reset occurs with removal of powerꢀ
B: Interval (power start)
Set timer for desired delay, apply power to coilꢀ Contacts transfer immediately, and return to original
position after preset time has elapsedꢀ Reset occurs with removal of powerꢀ
Item
Terminal Number
Operation
Item
Terminal Number
Operation
(1) 2 - 7
(2) A - B
(1) 2 - 7
(2) A - B
Power
Power
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(NC)
(NO)
(NC)
(NO)
Delayed
Contact
Delayed
Contact
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
PWR
OUT
Indicator
Set Time
Indicator
Set Time
T
T
C: Cycle 1 (power start, OFF first)
D: Cycle 3 (power start, ON first)
Functions in same manner as Mode C, with the exception that first transfer of contacts occurs as soon
as power is appliesꢀ The ratio is 1:1ꢀ Time On = Time Off
Set timer for desired delay, apply power to coilꢀ First transfer of contacts occurs after preset delay has
elapsed, after the next elapse of preset delay contacts return to original positionꢀ The timer now cycles
between on and off as long as power is applied (duty ratio 1:1)ꢀ
Item
Terminal Number
Operation
Item
Power
Terminal Number
Operation
(1) 2 - 7
(2) A - B
(1) 2 - 7
(2) A - B
Power
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(1) 1 - 4, 5 - 8
(2) 1 - 7, 3 - 9
(NC)
(NO)
(NC)
(NO)
Delayed
Contact
Delayed
Contact
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
(1) 1 - 3, 6 - 8
(2) 4 - 7, 6 - 9
PWR
OUT
PWR
OUT
Indicator
Set Time
Indicator
Set Time
T
T
T
T
1705151136
www.IDEC.com
946
RTE
Timers
Timing Diagrams con’t
RTE-P2, -B2
RTE-P2
control
signal
RTE-B2
external
external
start
start
control
signal
1ꢀ RTE-P2: Do not apply voltage to terminals #5, #6 & #7ꢀ
2ꢀ RTE-B2: Do not apply voltage to terminals #2, #5 & #8ꢀ
3ꢀ IDEC sockets are as follows: RTE-P2: SR3P-05ꢂ pin type socket,
RTE-B2: SR3B-05ꢂ blade type socket, (ꢂ-may be followed by suffix
letter A,B,C or U)ꢀ
1
6
3
6
2
5
5
7
4
8
4
3
9
7
8
9
2
10
1
11
A
B
(~/+
)
(~/-)
(~/+
)
(~/-)
A: ON-Delay 2 (signal start)
When a preset time has elapsed after the start input turned on while power is on, the NO output
contact goes onꢀ
B: Cycle 2 (signal start, OFF first)
When the start input turns on while power is on, the output oscillates at a preset cycle (duty ratio 1:1),
starting while the NO contact offꢀ
Item
Terminal Number
Operation
Item
Terminal Number
Operation
(A) 2 - 10
(B) A - B
(A) 2 - 10
(B) A - B
Power
Power
(A) 5 - 6
(B) 2 - 5
(A) 5 - 6
(B) 2 - 5
Start
Start
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(NC)
(NO)
(NC)
(NO)
Delayed
Contact
Delayed
Contact
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
PWR
OUT
Indicator
Set Time
Indicator
Set Time
T
T
T
T
T
T
T
T
T
T
Ta
C: Cycle 4 (signal start, ON first)
When the start input turns on while power is on, the NO contact goes onꢀ The output oscillates at a
preset cycle (duty ratio 1:1)ꢀ
D: Signal ON/OFF-Delay
When the start input turns on while power is on, the NO output contact goes onꢀ When a preset time
has elapsed while the start input remains on, the output contact goes offꢀ When the start input turns
off, the NO contact goes on againꢀ When a preset time has elapsed after the start input turned off, the
NO contact goes offꢀ
Item
Terminal Number
Operation
(A) 2 - 10
(B) A - B
Power
Item
Terminal Number
Operation
(A) 5 - 6
(B) 2 - 5
(A) 2 - 10
(B) A - B
Start
Power
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 5 - 6
(B) 2 - 5
(NC)
(NO)
Start
Delayed
Contact
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(NC)
(NO)
Delayed
Contact
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
Indicator
Set Time
PWR
OUT
Indicator
Set Time
T
T
T
T
T
T
T
T
Ta
E: Signal OFF-Delay
T
T
Ta
T
T
Ta
When power is turned on while the start input is on, the NO output contact goes onꢀ When a preset
time has elapsed after the start input turned off, the NO output contact goes offꢀ
F: One-Shot (signal start)
When the start input turns on while power is on, the NO output contact goes onꢀ When a preset time
has elapsed, the NO output contact goes offꢀ
Item
Terminal Number
Operation
(A) 2 - 10
(B) A - B
Power
Item
Terminal Number
Operation
(A) 5 - 6
(B) 2 - 5
(A) 2 - 10
(B) A - B
Start
Power
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(A) 5 - 6
(B) 2 - 5
(NC)
(NO)
Start
Delayed
Contact
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
(A) 1 - 4, 8 - 11
(B) 1 - 7, 3 - 9
(NC)
(NO)
Delayed
Contact
(A) 1 - 3, 9 - 11
(B) 4 - 7, 6 - 9
PWR
OUT
Indicator
Set Time
PWR
OUT
Indicator
Set Time
T
Ta
T
Ta
1705151136
800-262-IDEC (4332) • USA & Canada
947
RTE
Timers
Temperature Derating Curves
Mounting B
Mounting A
10A
7A
7A
5A
Mounting A
Mounting B
Derating Curve
Derating Curve
Ambient Temperature65
50
ºC
ºC
Ambient Temperature65
50
ºC
ºC
Instructions
Installation of Hold-Down Springs
DIN Rail Mount Socket
Switch Settings
Insert the springs into the outer
slots with the projections
facing inside.
Insert the springs
into the slots.
l
k
j
jOperator Mode Selector
kScale Selector
lTime Range Selector
Socket SR2P-05
Hold-down Spring (sold separately)
SFA-203 (use two springs)
Socket SR2P-06
Hold-down Spring (sold separately)
SFA-202 (use two springs)
1ꢀ Turn the selectors securely using a flat screw-
driver 4mm wide (maximum)ꢀ
Note that incorrect setting may cause malfunc-
tionꢀ Do not turn the selectors beyond their limitsꢀ
2ꢀ Since changing the setting during timer operation
may cause malfunction, turn power off before
changingꢀ
Safety Precautions
Special expertise is required to use Electronic Timersꢀ
• Do not use the Electronic Timer for an emergency stop circuit or inter-
locking circuitꢀ If the Electronic Timer should fail, a machine malfunction,
breakdown, or accident may occurꢀ
• All Electronic Timers are manufactured under IDEC’s rigorous quality control
system, but users must add a backup or fail safe provision to the control
system when using the Electronic Timer in applications where heavy damage
or personal injury may occur should the Electronic Timer failꢀ
Caution
Caution notices are used where inattention might cause personal injury or dam-
age to equipmentꢀ
• Install the Electronic Timer according to instructions described in this catalogꢀ
• Make sure that the operating conditions are as described in the specifica-
tionsꢀ If you are uncertain about the specifications, contact IDEC in advanceꢀ
• The Electronic Timer is designed for installation in equipmentꢀ Do not install
the Electronic Timer outside equipmentꢀ
• In these directions, safety precautions are categorized in order of importance
under Warning and Cautionꢀ
• Install the Electronic Timer in environments described in the specificationsꢀ If
the Electronic Timer is used in places where it will be subjected to high-tem-
perature, high-humidity, condensation, corrosive gases, excessive vibrations,
or excessive shocks, then electrical shocks, fire hazard, or malfunction could
resultꢀ
Warnings
Warning notices are used to emphasize that improper operation may cause
severe personal injury or deathꢀ
• Use an IEC60127-approved fuse and circuit breaker on the power and output
line outside the Electronic Timerꢀ
• Turn power off to the Electronic timer before starting installation, removal,
wiring, maintenance, and inspection on the Electronic Timerꢀ
• Do not disassemble, repair, or modify the Electronic Timerꢀ
• Failure to turn power off may cause electrical shocks or fire hazardꢀ
• When disposing of the Electronic Timer, do so as industrial wasteꢀ
1705151136
www.IDEC.com
948
RTE
Timers
Accessories
DIN Rail Mounting Accessories
DIN Rail/Surface Mount Sockets and Hold-Down Springs
DIN Rail Mount Socket
Applicable Hold-Down Springs
Appearance Part Number
Style
Appearance
Use with Timers Part Number
11-Pin Screw Terminal
(dual tier)
SR3P-05
RTE-P2
SFA-203
11-Pin FingerSafe Socket
8-Pin Screw Terminal
SR3P-05C
SR2P-06
RTE-P1
8-Pin Fingersafe Socket
11-Blade Screw Terminal
SR2P-05C
SFA-202
RTE-B1
SR3B-05
RTE-B2
DIN Mounting Rail
Length 1000mm
—
BNDN1000
Panel Mounting Accessories
Flush Panel Mount Adapter and Sockets that use an Adapter
Accessory
Description
Appearance
Use with
Part No.
Adaptor for flush panel
mounting RTE timers
Panel Mount Adapter
All RTE timers
RTB-G01
8-pin screw terminal
11-pin screw terminal
RTE-P1
RTE-P2
SR6P-M08G
SR6P-M11G
(Shown: SR6P-M08G Wiring Socket Adapter)
Sockets for use with
Panel Mount Adapter
8-pin solder terminal
11-pin solder terminal
RTE-P1
RTE-P2
SR6P-S08
SR6P-S11
1705151136
800-262-IDEC (4332) • USA & Canada
949
RTE
Timers
Dimensions
13.0
77.9
36.0
13.7
RTE-P1 (8 pin) Terminal Style
RTE-P2 (11 pin)Terminal Style
7.3
RTE-B1/RTE-B2 (11 blade) Terminal Style
Panel Mount Adapter
RTE Timer, 8-Pin and 11-Pin with SR6P-S08 or SR6P-S11
98 maximum
Panel Thickness 0.8 to 5mm
Back Wiring Socket
48
11
61.2
RTE Timer, 8-Pin with SR6P-M08G
8-M3.5 Terminal Screw
44.6
Panel Thickness 0.8 to 5mm
3.5 max.
5.6 min.
ø3.6 min.
3
2
4
1
5
8
6
7
6.9 max.
7
9.8 x 3
80.5
RTE Timer, 11-Pin with SR6P-M11G
11-M3.5 Teminal Screws
45
16.7
5.8 min.
ø3.6 min.
3.5 max.
2
4
1
3
11
8
7
9
6
5
6.9 max.
10
30.5
7
92
8.5 x 4
1705151136
www.IDEC.com