HS1L Interlock Switches with Solenoid
Suitable for large and heavy doors.
Same actuators as HS1E (locking strength 3000N) can be used.
Same dimensions and mounting
hole layouts as HS1E.
Size: 35 × 104 × 129mm
LED
Indicator
Door open, closed, and locked status can be
monitored for various applications.
Manual
Unlock Key
Straight Actuator
(Zinc Diecast)
L-shaped Actuator
Angle Adjustable
(vertical) Actuator
Energyꢀefficientꢀnewꢀsolenoidꢀunit.
Solenoid Current Consumption
Approx.
292 mA
%
32
Less
•ꢀManual unlock key and LED indicator are standard.
•ꢀManual unlock key allows for manual unlocking in the event of
power failure or maintenance.
200 mA
•ꢀIndicator has an independent circuit, and can be used for vari-
ous applications.
•ꢀTwo locking mechanisms to choose from—spring lock (un-
locked with energized solenoid) or solenoid lock (locked with
energized solenoid).
•ꢀM3 terminal screws for wiring.
•ꢀWide operating temperature range (–20 to +55°C).
HS1E
HS1L
Interlock Switch
with Solenoid
Interlock Switch
with Solenoid
*As of October 2009, according to IDEC research of plastic interlock switches with solenoid.
HS1L Interlock Switches with Solenoid
Specifications
Ratings
•ꢀContactꢀRatings
Rated Insulation Voltage (Ui)
Rated Operating Current (Ith)
Rated Operating Voltage (Ue)
ISO14119
IEC60947-5-1
EN60947-5-1 (TÜV approval)
GS-ET-19 (TÜV approval)
UL508 (UL listed)
300V
10A
125V
10A
5A
Applicable Standard
30V
10A
10A
8A
250V
6A
CSA C22.2 No. 14 (c-UL listed)
IEC60204-1/EN60204-1
(applicable standards for use)
Resistive Load (AC-12)
Inductive Load (AC-15)
Resistive Load (DC-12)
Inductive Load (DC-13)
Rated
AC
DC
3A
Operating
Current
(Ie)
Operating Temperature −20ꢀtoꢀ+55°Cꢀ(noꢀfreezing)
2.2A
1.1A
1.1A
0.6A
Relative Humidity
45 to 85% (no condensation)
4A
Storage Temperature
Pollution Degree
–40 to +80°C (no freezing)
•ꢀ Minimum applicable load (reference value): 3V AC/DC, 5mA
3
(Applicable range may vary with operating conditions and load types.)
•ꢀ TÜV rating: AC-15 3A/250V, DC-13 4A/30V
UL, c-UL rating: A300
Overvoltage Category
III
Impulse Withstand
Voltage
4.0kV
(between LED, solenoid and ground: 1.5 kV)
Pilot duty: AC 3A/250V
Pilot duty: DC 4A/30V
Contact Resistance
50mΩꢀmaximumꢀ(initialꢀvalue)
Between live and dead metal parts:
100MΩꢀminimumꢀ(500VꢀDCꢀmegger)
Between terminals of different poles:
100MΩꢀminimumꢀ(500VꢀDCꢀmegger)
•ꢀSolenoidꢀUnitꢀandꢀLEDꢀIndicator
Insulation Resistance
Spring Lock
Solenoid Lock
Lock Mechanism
Rated Operating
Voltage
24V DC (100% duty cycle)
Electric Shock
Protection
Class II (IEC 61140)
Rated Current
200 mA (initial value)
Degree of Protection
Shock Resistance
IP67 (IEC 60529)
Damage limits: 1000m/s2
Coil Resistance
Pickup Voltage
Dropout Voltage
120Ωꢀ(atꢀ20°C)
Rated voltage × 85% max. (at 20°C)
Rated voltage × 10% max. (at 20°C)
Operating extremes:
10 to 55Hz, amplitude 0.35mm
Damage limits: 30Hz, amplitude 1.5mm
Solenoid
Vibration Resistance
Maximum Continuous
Applicable Voltage
Rated voltage × 110%
Actuator Operating
Speed
0.05 to 1.0 m/s
Maximum Continuous
Applicable Time
Continuous
Class F
Direct Opening Travel
Direct Opening Force
11mm minimum
50N minimum
Insulation Class
Actuator Retention
Force when Locked
Rated Operating
Voltage
3000N minimum (GS-ET-19)
24V DC
Operating Frequency
Mechanical Durability
900 operations per hour
Rated Current
Light Source
10 mA
LED
1,000,000 operations minimum (GS-ET-19)
LED
100,000 operations minimum
(AC-15 3A/250V)
Illumination Color
Green (G), Red (R)
Electrical Durability
1,000,000 operations minimum
(24V AC/DC, 100mA)
(operating frequency 900 operations per hour)
Parts and Functions
Conditional Short-circuit 100A (250V) (Use 250V/10A fast acting type
Current
fuse for short-circuit protection.)
Contact
Mechanism (M3)
Weight (approx.)
450g (HS1L-DQ44)
Part Number Guide
Terminal
Block (M3)
HS1L-DQ44KMSRP-R
LED Color
G: Green
R: Red
Conduit Port Size
Blank: 1/2
Circuit Code
Main Circuit Monitor Circuit
R: 1NC+1NC
DQ: 1NC+1NC/
1NC+1NC
1NC/1NO, 2NC
1NO, 1NO
P:
M:
PG13.5
M20
DT: 1NC+1NC/
1NC+1NC
1NC, 1NC
Conduit Port
Housing Color
R: Red and Black
Solenoid Unit Voltage/
Lock Mechanism
4: 24V DC/Spring Lock
7Y: 24V DC/Solenoid Lock
Locking Strength
MS: 3000N
Manual Unlocking
Key
Actuator Entry Slots
(Two)
LED Rated Voltage
4: 24V DC
K: With key
•ꢀActuator
•ꢀAccessories
Description
Part Numbers
HS9Z-A1S
HS9Z-A2S
HS9Z-A3S
Description
Part Numbers
Straight Actuator
Key Wrench for TORX Screw (L-shaped)
Conduit Port Plug (Size: G1/2 only)
•ꢀPackage quantity: 1
HS9Z-T1
HS9Z-P1
L-shaped Actuator
Angle Adjustable (vertical) Actuator (for hinged door)
•ꢀPackage quantity: 1
•ꢀ Key Wrench for TORX Screw is supplied with the interlock switch.
2
HS1L Interlock Switches with Solenoid
Types
Manual
Unlocking
Key
Lock
Mechanism
Circuit
Code
Conduit
LED
ContactꢀConfiguration
Part Number
Port Size Indicator
Door Monitor
Lock Monitor
Red
G1/2
HS1L-R44KMSR-R
HS1L-R44KMSR-G
HS1L-R44KMSRP-R
HS1L-R44KMSRP-G
HS1L-R44KMSRM-R
HS1L-R44KMSRM-G
(Actuator Inserted) (Solenoid OFF)
LED
+
-
)
(
)
(
+
-
( )
A1
(
)
Green
X2
X1
A2
Main: 1NC+1NC
Door monitor: 1NO/1NC
Lock monitor: 2NC
Red
PG13.5
R
11
21
33
12
41
42
Main circuit:
Green
22
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
34
Red
M20
51
61
52
62
Green
Main: 1NC+1NC
1NC+1NC
Door monitor: 1NO
Lock monitor: 1NO
Red
G1/2
HS1L-DQ44KMSR-R
HS1L-DQ44KMSR-G
HS1L-DQ44KMSRP-R
HS1L-DQ44KMSRP-G
HS1L-DQ44KMSRM-R
HS1L-DQ44KMSRM-G
Green
Spring Lock
With
11
21
33
12
22
41
51
42
52
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
Red
PG13.5
DQ
DT
Green
34
63
64
Red
M20
Green
Main: 1NC+1NC
1NC+1NC
Door monitor: 1NC
Lock monitor: 1NC
Red
G1/2
HS1L-DT44KMSR-R
HS1L-DT44KMSR-G
HS1L-DT44KMSRP-R
HS1L-DT44KMSRP-G
HS1L-DT44KMSRM-R
HS1L-DT44KMSRM-G
Green
11
21
31
12
22
32
41
51
42
52
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
Red
Green
PG13.5
Red
Green
61
62
M20
Door Monitor
Lock Monitor
Red
G1/2
HS1L-R7Y4KMSR-R
HS1L-R7Y4KMSR-G
HS1L-R7Y4KMSRP-R
HS1L-R7Y4KMSRP-G
HS1L-R7Y4KMSRM-R
HS1L-R7Y4KMSRM-G
(Actuator Inserted) (Solenoid ON)
LED
+
-
)
(
)
(
+
-
( )
A1
(
)
X2
X1
A2
Green
Main: 1NC+1NC
Door monitor: 1NO/1NC
Lock monitor: 2NC
Red
PG13.5
R
11
21
33
12
22
34
41
42
Main circuit:
Green
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Red
M20
51
61
52
62
Green
Main: 1NC+1NC
1NC+1NC
Door monitor: 1NO
Lock monitor: 1NO
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
HS1L-DQ7Y4KMSR-R
HS1L-DQ7Y4KMSR-G
HS1L-DQ7Y4KMSRP-R
HS1L-DQ7Y4KMSRP-G
HS1L-DQ7Y4KMSRM-R
HS1L-DQ7Y4KMSRM-G
HS1L-DT7Y4KMSR-R
HS1L-DT7Y4KMSR-G
HS1L-DT7Y4KMSRP-R
HS1L-DT7Y4KMSRP-G
HS1L-DT7Y4KMSRM-R
HS1L-DT7Y4KMSRM-G
G1/2
Solenoid Lock
With
11
21
33
12
22
41
51
42
52
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
DQ
DT
PG13.5
34
63
64
M20
Main: 1NC+1NC
1NC+1NC
Door monitor: 1NC
Lock monitor: 1NC
G1/2
11
21
31
12
22
32
41
51
42
52
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
PG13.5
61
62
M20
•ꢀTheꢀcontactꢀconfigurationꢀshowsꢀtheꢀstatusꢀwhenꢀtheꢀactuatorꢀisꢀinsertedꢀandꢀtheꢀswitchꢀisꢀlocked.
•ꢀActuators are not supplied with the interlock switch and must be ordered separately.
Terminal Numbers
11-42: Main circuit
21:
22:
Main circuit or monitor circuit (door monitor)
Monitor circuit (door monitor)
31/33: Monitor circuit (door monitor)
32/34: Monitor circuit (door monitor)
62/64
X2 X1 A2
A1
61/63
32/34
51:
52:
Monitor circuit (lock monitor)
Main circuit or monitor circuit (lock monitor)
31/33
52
42
51
41
61/63: Monitor circuit (lock monitor)
62/64: Monitor circuit (lock monitor)
A1:
A2:
X1:
X2:
Solenoid (–)
Solenoid (+)
LED (–)
21
11
22
12
LED (+)
* There is no wiring between 22-51 with circuit code R.
3
HS1L Interlock Switches with Solenoid
Dimensions and Mounting Hole Layouts (mm)
•ꢀInterlock switch when using
L-shaped actuator (HS9Z-A2S)
•ꢀInterlock switch when using
straight actuator (HS9Z-A1S)
104
88
33
4
10
Actuator Cover
11.5
Actuator Cover
HS9Z-A2S Actuator
Rubber Bushing
±±.5
17.5
HS9Z-A1S Actuator
0.5
(3.5
)
19.2
22
Actuator Entry Slot
(51.3)
55.8
(Vertical to mounting panel)
Actuator mounting
reference position
21
44.7
61
Rubber Bushing
Actuator mounting
reference position
89
5
89
Actuator Entry Slot
36
(Horizontal to
mounting panel)
Slot Plug
∗ When using the actuator entry slot
(supplied with the switch)
(Note)
vertical to the mounting panel.
Interlock Switch Mounting Hole Layout
Note: Plug the unused actuator entry slot with the slot plug supplied with the interlock switch.
* Install the interlock switch using four mounting screws when using the actuator entry slot vertical to the mounting panel,
and three mounting screws when using the actuator entry slot horizontal to the mounting panel.
•ꢀStraight Actuator (HS9Z-A1S)
•ꢀL-shaped Actuator (HS9Z-A2S)
9
49.3
18.5
0.8
(45.1)
42.6
20.5
11.5
2-M5
11.5
Screws
0.8
2-M5 Screws
Actuator
Mounting Hole
Layout
Actuator Cover
(gray) (Note)
Actuator Mounting
Hole Layout
Actuator Cover
(gray) (Note)
When
mounted (8)
3
•ꢀAngle Adjustable (vertical) Actuator
(HS9Z-A3S)
Actuator Stop
Film (supplied
with the actuator)
18
Note:ꢀTheꢀactuatorꢀcoverꢀandꢀtheꢀactuatorꢀstopꢀfilmꢀareꢀsuppliedꢀwithꢀ
the actuator and used when adjusting the actuator position.
Remove them after the actuator position has been determined.
2-M6 Screws
5
2
Actuator Mounting
20
Door Hinge
Angle Adjustment Screw
(M3 hexagon sockethead bolt)
Hole Layout
30
Interlock
Switch
Interlock
Switch
Door Stop
Door Stop
•ꢀActuator Mounting Reference Position
Interlock
Switch
Actuator
Stop Film
Asꢀshownꢀinꢀtheꢀfigureꢀonꢀtheꢀright,ꢀtheꢀmountingꢀreferenceꢀ
position of the actuator, when inserted in the interlock switch, is
where the actuator stop placed on the actuator lightly touches the
interlock switch.
Acuator
Cover
HS9Z-A1S
Actuator
Acuator Cover
HS9Z-A2S
Actuator
HS9Z-A3S
Actuator
Note: After mounting the actuator, remove the actuator cover and
stopꢀfilm.
4
HS1L Interlock Switches with Solenoid
Circuit Diagrams and Operating Characteristics
•ꢀSpring Lock Type
Status 1
Status 2
Status 3
Status 4
Manual Unlock
•ꢀDoor Closed
•ꢀDoor Closed
•ꢀDoor Open
•ꢀDoor Open
•ꢀDoor Closed
Interlock Switch Status
•ꢀMachine ready to
•ꢀMachine cannot be
•ꢀMachine cannot be
operated
•ꢀMachine cannot be
operated
•ꢀMachine cannot be
operated
operate
operated
•ꢀSolenoid de-energized •ꢀSolenoid energized
•ꢀSolenoid energized
•ꢀSolenoid de-energized
•ꢀSolenoid de-energized
Door Status
UNLOCK
Unlock position
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
11
21
33
12
22
34
41
51
63
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
Circuit Diagram (HS1L-DQ4)
52
64
51
63
52
64
51
63
52
64
51
63
52
64
51
63
52
64
Closed (locked)
ON (closed)
Closed (unlocked)
OFF (open)
Open
Open
Closed (unlocked)
OFF (open)
Door
Main Circuit
11–42
HS1L-DQ4
Door Monitor Lock Monitor
OFF (open)
OFF (open)
OFF (open)
OFF (open)
(Actuator
inserted)
(Solenoid
OFF)
LED
Main Circuit
21–52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
(+)
X2
(–)
X1
(+)
(–)
A1
A2
Door Monitor
Circuit
(Door Open)
33–34
11
12
22
34
41
51
42
52
Main Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
ON (closed)
ON (closed)
ON (closed)
ON (closed)
21
33
63
64
Lock Monitor
Circuit
(unlocked) 63-64
OFF (open)
ON (closed)
ON (closed)
OFF (de-energized)
ON (energized)
ON (energized)
OFF (de-energized)
OFF (de-energized)
Solenoid Power A1-A2
•ꢀSolenoid Lock Type
Status 1
Status 2
Status 3
Status 4
Manual Unlock
•ꢀDoor Closed
•ꢀDoor Closed
•ꢀMachine ready to
operate
•ꢀDoor Closed
•ꢀMachine cannot be
operated
•ꢀDoor Open
•ꢀDoor Open
•ꢀMachine cannot be
operated
•ꢀMachine cannot be
operated
Interlock Switch Status
•ꢀMachine cannot be
operated
•ꢀSolenoid de-energized
to energized
•ꢀSolenoid energized
•ꢀSolenoid de-energized •ꢀSolenoid de-energized •ꢀSolenoid energized
Door Status
UNLOCK
Unlock position
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
(+)
A2
(–)
A1
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
11
21
33
12
22
34
41
42
Circuit Diagram (HS1L-DQ4)
51
63
52
64
51
63
52
64
51
63
52
64
51
63
52
64
51
63
52
64
Closed (locked)
ON (closed)
Closed (unlocked)
OFF (open)
Open
Open
Closed (unlocked)
OFF (open)
Door
Main Circuit
11–42
HS1L-DQ7Y
OFF (open)
OFF (open)
Lock Monitor
(Solenoid
ON)
Door Monitor
(Actuator
LED
Main Circuit
21–52
inserted)
(+)
X2
(–)
X1
(+)
A2
(–)
A1
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
Door Monitor
Circuit
(Door Open)
33–34
11
21
33
12
22
34
41
51
42
52
Main Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
63
64
Lock Monitor
Circuit
(unlocked) 63-64
OFF (open)
ON (energized)
(Note 2)
OFF to ON
(Note 1) (Note 2)
Solenoid Power A1-A2
ON (energized)
OFF (de-energized) OFF (de-energized)
Note 1: Do not attempt manual unlocking while the solenoid is energized.
Note 2: Do not energize the solenoid for a long period of time while the door is open or manually unlocked.
•ꢀOperation Characteristics (reference)
0 (Actuator insertion position)
4.2 (Locked position)
•ꢀ The operation characteristics show the contact status when the
actuator enters into the center of the entry slot.
7.0 10.0
30.0 (Approx. travel in mm)
Main Circuit
•ꢀ The circuit No. 12-41 and 22-51 are interconnected. Use circuits
11-42 and 21-52 for safety circuits (In HS1L-R type, circuit 12-41 is
interconnected.)
Door Monitor Circuit (Door open, NO)
Door Monitor Circuit (Door closed,NC
Lock Monitor Circuit (Unlocked, NO)
Lock Monitor Circuit (Locked, NC)
Contacts ON (closed)
Contacts OFF (open)
)
5
HS1L Interlock Switches with Solenoid
Safety Precautions
!
•ꢀInꢀorderꢀtoꢀavoidꢀelectricꢀshockꢀorꢀfire,ꢀturnꢀpowerꢀoffꢀbeforeꢀ
installation, removal, wiring, maintenance, or inspection of the
interlock switch.
•ꢀIf relays are used in the circuit between the interlock switch
and the load, consider the danger, and use safety relays,
since welded or sticking contacts of standard relays may in-
validate the functions of the interlock switch. Perform a risk
assessmentꢀandꢀestablishꢀaꢀsafetyꢀcircuitꢀwhichꢀsatisfiesꢀtheꢀ
requirement of the safety category.
•ꢀDo not place a PLC in the circuit between the interlock switch
and the load. Safety security can be endangered in the event
of a malfunction of the PLC.
•ꢀDo not disassemble or modify the interlock switch, otherwise
the switch may fail or an accident may occur.
•ꢀDo not install the actuator in a location where someone may
come in contact with it as injury may occur.
•ꢀInstall the actuator where it does not touch anyone when the
door is opened/closed as injury may occur.
•ꢀThe solenoid lock type is locked when energized, and un-
locked when de-energized. When energization is interrupted
due to wire disconnection or other failures, the interlock switch
may be unlocked causing possible danger to the operators.
Solenoid lock type must not be used in applications where
locking is required for safety. Perform a risk assessment and
determine whether a solenoid lock type is appropriate.
•ꢀIn order to prevent the interlock switch and actuator from be-
ing removed without authorization, it is recommended to in-
stall an one-way screw or a screw that needs a special tool for
removal. Welding or rivets are also recommended.
Instructions
•ꢀRegardless of door types, do not use the interlock switch as
a door stop. Install a mechanical door stop at the end of the
door to protect the interlock switch from excessive force.
•ꢀMake sure that no force is applied on the actuator, otherwise
the actuator may not unlock properly.
When using HS9Z-A2S Actuator
•ꢀWhen the door hinge is on the extension line of the interlock
switch surface:
•ꢀDo not apply excessive shock to the interlock switch when
opening or closing the door. A shock to the interlock switch ex-
ceeding 1,000m/s2 may cause damage to the interlock switch.
•ꢀIf the operating atmosphere is contaminated, use a protective
cover to prevent the entry of foreign objects into the interlock
switch through the actuator entry slots. Entry of foreign ob-
jects into the interlock switch may affect the mechanism of the
interlock switch and cause it to fail.
Door Hinge
Door Hinge
•ꢀWhen the door hinge is on the extension line of the actuator
mounting surface:
•ꢀPlug the unused actuator entry slot using the slot plug sup-
plied with the interlock switch.
•ꢀDo not store the interlock switches in a dusty, humid, or or-
ganic-gas atmosphere, or where the switches are exposed to
direct sunlight.
Door Hinge
Door Hinge
•ꢀUse proprietary actuators only. The interlock switch may be
damaged if other actuators are used, .
When using HS9Z-A3S Actuator
•ꢀWhen the door hinge is on the extension line of the interlock
switch surface: 50mm
•ꢀWhen the door hinge is on the extension line of the actuator
mounting surface: 80mm
•ꢀThe actuator retention force is 3000N. Do not apply a load
higher than the rated value. When a higher load is expected,
provide an additional system consisting of another interlock
switch without lock (such as the HS5D interlock switch) or a
sensor to detect door opening and stop the machine.
•ꢀRegardless of the door, do not use the interlock switch as a
door lock. Install a separate lock using a latch or other device.
•ꢀWhile the solenoid is energized, the interlock switch tempera-
ture rises approximately 40°C above the ambient tempera-
ture (to approximately 95°C while the ambient temperature is
55°C). To prevent burns, do not touch. If cables might come
into contact with the interlock switch, use heat-resistant ca-
bles.
Door Hinge
Door Hinge
Actuator Angle Adjustment
•ꢀUsing the angle adjustment screw, the actuator angle can
be adjusted (refer to the dimensional drawing on page 4).
Adjustable angle: 0 to 20°
•ꢀThe interlock switch solenoid has polarity. Be sure of the cor-
rect polarity when wiring.
•ꢀThe larger the adjusted angle of the actuator, the smaller the
applicable radius of the door opening. After installing the actu-
ator, open the door. Then adjust the actuator so that its edge
can be inserted properly into the actuator entry slot of the in-
terlock switch.
•ꢀAfter adjusting the actuator angle, apply Loctite to the adjust-
ment screw so that the screw will not move.
Minimum Radius of Hinged Door
When using the interlock switch for a hinged door, refer to
the minimum radius of doors as shown below. For doors with
a small minimum radius, use actuators with adjustable angle
(HS9Z-A3S).
Note: The following values apply when the actuator does not interfere with
the interlock switch when opening and closing the door. Because de-
viation or dislocation of hinged door may occur in actual applications,
make sure of the correct operation before installation.
6
HS1L Interlock Switches with Solenoid
Instructions
•ꢀUnlocking from the back of interlock switch
Insert the tip of a small screwdriver into the oblong hole on the
back of the interlock switch, and tilt toward the center of the
switch until the actuator is unlocked.
Mounting Examples
Installꢀtheꢀinterlockꢀswitchꢀandꢀactuatorꢀreferringꢀtoꢀtheꢀfiguresꢀ
below.
Application on Slinding Doors
Note: Provide a hole on the mounting panel for unlocking from
the back. When making a hole in the panel, take water-
proof characteristics into consideration.
Door
Interlock Switch
2.6
HS9Z-A1S
Latch
Door Stop
Application on Hinged Doors
Safety Precautions
Before manually unlocking the interlock switch, make sure that
the machine has come to a complete stop. Manual unlocking
during operation may unlock the interlock switch before the ma-
chine stops, and the function of interlock switch with solenoid
is lost.
On the solenoid lock type, manual unlocking is provided for the
situation where the switch cannot be unlocked even though the
solenoid has turned off. Do not attempt manual unlocking while
the solenoid is energized.
Door
Interlock Switch
Latch
HS9Z-A2S
HS9Z-A1S
For Manual Unlocking
Spring lock type
The HS1L allows manual unlocking of the actuator to pre-check
proper door movement before wiring or turning power on, as
well as for emergency use such as in the case of a power fail-
ure.
Cover Opening and Closing Precautions
•ꢀWhen opening the cover before wiring, make sure to open
onlyꢀtheꢀcoverꢀshownꢀtheꢀfollowingꢀfigure.ꢀRemovingꢀunneces-
sary screws may cause a failure of the interlock switch.
Solenoid lock type
•ꢀUse HS9Z-T1 key wrench for TORX screw when removing
and installing the cover.
•ꢀMake sure that no foreign objects such as dust, water, or oil
enter the interlock switch when wiring.
The solenoid lock type interlock switch normally does not need
to be manually unlocked. However, only when the interlock
switch would not release the actuator even though the solenoid
is de-energized, the interlock switch can be unlocked manually.
Unlock the interlock switch manually only when the solenoid is
de-energized. Do not unlock the interlock switch manually when
the solenoid is energized.
HS9Z-T1
L-shaped wrench
(supplied with the switch)
T20
Lid
Using manual unlock key
•ꢀWhen locking or unlocking the interlock switch manually, turn
the key fully using the manual unlock key supplied with the
interlock switch.
•ꢀUsing the interlock switch with the key not fully turned (less
than 90°) may cause damage to the interlock switch or op-
eration failure. When manually unlocked, the interlock switch
will keep the main circuit disconnected and the door unlocked.
Main circuit and lock monitor circuit remain open.
•ꢀDo not leave the manual unlock key attached to the interlock
switch during operation. This is dangerous and does not satis-
fy safety standard requirements, because the interlock switch
can always be unlocked while the machine is in operation.
Applicable Crimping Terminal
Approx.
3.2 min.
ø
4 mm
Wire
Applicable
Crimping
Terminal
Insulation Tube
4.2 min.
Manual unlocking key
(supplied with the switch)
•ꢀUse an insulation tube on the crimping terminal.
UNLOCK
UNLOCK
•ꢀWhen using stranded wires, make sure that loose wires do
not cause a short circuit. Also, do not solder the terminal to
prevent loose wires.
Manual Unlocking Position
Normal Position
Applicable Crimping Terminal
N0.5-3 / FN0.5 (JST)
N1.25-MS3 (JST)
Applicable Wire
0.2 to 0.5mm2
0.25 to 1.65mm2
0.25 to 1.65mm2
V1.25-YS3A (JST)
Applicable Wire Size
•ꢀ0.5 to 1.5mm2
Applicable Cable Glands
Use IP67 cable glands.
7
HS1L Interlock Switches with Solenoid
Instructions
G1/2, PG13.5, M20
•ꢀTerminal:
•ꢀCable gland:
•ꢀActuators
HS9Z-A1S/A2S: 2.7 to 3.3 N·m (two M5 screws) (Note)
HS9Z-A3S: 4.5 to 5.5 N·m (two M6 screws) (Note)
0.6 to 0.8 N·m (M3 screws)
2.7 to 3.3 N·m
9 mm max.
When Using Flexible Conduit (Example)
Flexible conduit example: VF-03 (Nihon Flex)
Note:The above recommended tightening torque of the mounting
screws are the values when using hex socket head bolts. When
other screws are used and tightened to a smaller torque, make
sure that the screws do not become loose after mounting.
Conduit Port Size Plastic Cable Gland
Metal Cable Gland
G1/2
PG13.5
M20
–
–
–
RLC-103 (Nihon Flex)
•ꢀWire Length Inside the Interlock Switch
RBC-103PG13.5 (Nihon Flex)
RLC-103EC20 (Nihon Flex)
Through Conduit Port
Screw Terminal No.
➀
➁
11
21
95 ± 2
85 ± 2
60 ± 2
75 ± 2
50 ± 2
65 ± 2
45 ± 2
55 ± 2
35 ± 2
45 ± 2
50 ± 2
60 ± 2
70 ± 2
80 ± 2
45 ± 2
35 ± 2
70 ± 2
35 ± 2
60 ± 2
95 ± 2
70 ± 2
85 ± 2
60 ± 2
75 ± 2
45 ± 2
40 ± 2
35 ± 2
35 ± 2
When Using Multi-core Cables (Example)
Flexible conduit example: VF-03 (Nihon Flex)
22
Conduit Port Size
Plastic Cable Gland
Metal Cable Gland
31/33
32/34
42
SCS-10
(Seiwa Electric)
ALS-16
(Nihon Flex)
G1/2
ST13.5
ABS-PG13.5
(Nihon Flex)
ALS-EC20
(Nihon Flex)
PG13.5
M20
51
Wire Length
L1 (mm)
(K-MECS)
52
ST-M20X1.5
(K-MECS) (Note)
61/63
62/64
A1
•ꢀDifferent cable glands are used depending on the cable sheath exter-
nalꢀdiameter.ꢀWhenꢀpurchasingꢀaꢀcableꢀgland,ꢀconfirmꢀthatꢀtheꢀcableꢀ
gland is applicable to the external diameter of the cable sheath.
Note: When using the ST-M20X1.5 cable gland, use with a gasket
(GPM20, K-MECS).
A2
X1
X2
7 ± 1
Wire Stripping Length: L2 (mm)
Conduit Port Opening
•ꢀMake an opening for wiring by breaking one of the conduit-
port knockouts on the interlock switch housing using a
screwdriver.
➀
Connector
•ꢀBefore opening the conduit port, remove the cable gland
62/64
X2
X1 A2
A1
locking ring inside the interlock switch.
61/63
32/34
31/33
•ꢀWhen breaking the conduit port, take care not to damage the
contact block or other parts inside the interlock switch.
•ꢀCracks or burrs on the conduit entry may affect the water
resistance of the interlock switch.
•ꢀIf a different conduit port is used, cover the unused opening
with an optional plug (part number: HS9Z-P1).
52
42
51
41
➁
21
11
22
12
Interlock
Switch
•ꢀ Recommended Tightening Torque
•ꢀHS1L interlock switch: 3.2 to 3.8 N·m (four M5 screws) (Note)
Note:
HS1L-R
•ꢀLid:
0.9 to 1.1 N·m (M4 screws)
Do not remove the wire between terminals 12-41, because these
terminals are interconnected for safety circuit input. Use terminals
11-42 for safety circuit inputs. (GS-ET-19)
Plug (HS9Z-P1)
HS1L-DQ and HS1L-DT
Do not remove the wires between terminals 12-41 and 22-51, be-
cause these terminals are interconnected for safety circuit inputs.
Use terminals 11-42 and 21-52 for safety circuit inputs. (GS-ET-19)
ø26
G1/2
Specifications and other descriptions in this catalog are subject to change without notice.
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: marketing@idec.co.jp
IDEC IZUMI (H.K.) CO., LTD.
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: info@hk.idec.com
IDEC ELECTRONICS LIMITED
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: sales@uk.idec.com
IDEC CORPORATION (USA)
Tel: +1-408-747-0550 / (800) 262-IDEC (4332)
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: opencontact@idec.com
IDEC TAIWAN CORPORATION
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: service@tw.idec.com
IDEC ELEKTROTECHNIK GmbH
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: service@idec.de
IDEC CANADA LIMITED
Tel: +1-905-890-8561, Toll Free: (888) 317-4332
Fax: +1-905-890-8562
IDEC IZUMI ASIA PTE. LTD.
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: info@sg.idec.com
IDEC (SHANGHAI) CORPORATION
Tel: +86-21-5353-1000, Fax: +86-21-5353-1263
E-mail: idec@cn.idec.com
E-mail: sales@ca.idec.com
IDEC AUSTRALIA PTY. LTD.
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332
Fax: +61-3-9763-3255
IDEC (BEIJING) CORPORATION
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119
IDEC (SHENZHEN) CORPORATION
E-mail: sales@au.idec.com
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
www.IDEC.com
Cat. No. EP1286-0-1 Updated October 2010 PDF only