LF07-WBJ-4S [HRS]

Miniature Waterproof Shielded Connectors; 微型防水连接器屏蔽
LF07-WBJ-4S
型号: LF07-WBJ-4S
厂家: HRS    HRS
描述:

Miniature Waterproof Shielded Connectors
微型防水连接器屏蔽

连接器
文件: 总11页 (文件大小:346K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
NEW  
Miniature Waterproof Shielded Connectors  
LF Series  
Mated dimensions  
8.9 mm max. (3 pos.)  
36.4  
Receptacle  
Plug  
Short turn bayonet lock  
Mating:  
Insert the plug, and then turn the locking collar clockwise,  
as indicated by the coupling direction marking.  
Features  
1. Ease of shielded termination and connector  
Plug  
assembly  
Coupling direction marking  
Receptacle  
Un-mating:  
Locking collar  
All components are self-aligning and do not require complex  
assembly tooling. The shield of the cable is connected with the  
metal housing of the connector using simple shielding clamp,  
supplied with the connector.  
Turn the locking collar counter-clockwise  
than pull off the plug.  
2. Water and dust protected  
IP67 protection rating. Complete protection against dust  
penetration and against water penetration when mated  
assembly is submerged at the depth of 1.8 meter for 48 hours.  
Coupling direction marking  
Shielding Connection - Plug  
Built-in shield  
3. Bayonet lock  
Short turn bayonet lock assures secure vibration resistant  
mating of the connectors.  
4. High current rating capacity  
connection spring  
Cable shielding connection clamp  
Number of contacts  
Current rating  
Cable  
3
5A max.  
4
10A max.  
2A max.  
6, 12 and 20  
10A max.  
2A max.  
11  
5. RoHS compliant  
All components and materials comply with the requirements of  
the EU Directive 2002/95/EC.  
Applications  
Sensors, robots, injection molding machines, NC, factory  
automation equipment, surveying instruments, measuring  
instruments, medical equipment, surveillance cameras and  
base stations.  
2008.5  
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Product Specifications  
125V AC, 175V DC (3 pos.)  
125V AC, 125V DC (4 pos.)  
30V AC, 42V DC (6 pos. , 12pos. , 20pos.)  
125V AC, DC (11 pos. A to D)  
30V AC, 42V DC (11 pos. 1 to 7)  
5A max. (3 pos.)  
10A max. (4 pos.)  
2A max. (6 pos. , 12pos. , 20pos.)  
10A(11 pos. A to D), 2A(11 pos. 1 to 7)  
Voltage rating  
Rating  
Current rating  
Operating temperature range  
Storage temperature range  
25ç to +85ç (Note 1)  
25ç to +85ç (Note 2)  
Item  
Specification  
Conditions  
15 mø max. (3, 6, 12, 20 pos.)  
15 mø max. (4 pos.)  
15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.)  
11.Contact resistance  
1A DC  
500V DC (3, 4 pos.)  
12.Insulation resistance  
13.Withstanding voltage  
1000 Mø min.  
100V DC (6, 12, 20 pos.)  
500V DC (A to D), 100V DC (1 to 7)(11pos.)  
1250V AC/one minute (3, 4 pos.)  
300V AC/one minute (6, 12, 20 pos.)  
1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.)  
No flashover or insulation breakdown.  
No electrical discontinuity for 10μs max.  
No electrical discontinuity for 10μs max.  
Frequency: 10 to 500Hz, single amplitude of 0.75mm,  
14.Vibration  
15.Shock  
2
acceleration of 98 m/s for 3 hours in 3 axis.  
2
Acceleration of 490m/s , 11ms duration,  
sine half-wave waveform, 3 cycles in each of the 3 axis.  
30 mø max.  
10 mø max.  
(3, 6, 12, 20 pos.)  
(4 pos.)  
16.Durability  
1000 cycles  
16.(Mating/un-mating)  
10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.)  
Temperature: -55ç Room temperature +125ç Room temperature  
Time: 30 10 to 15 30 10 to 15 (minutes) 5 cycles  
17.Temperature cycle  
Insulation resistance: 100 Mø min.  
Insulation resistance: 110 Mø min. (When temperature high)  
Insulation resistance: 100 Mø min. (Dray state)  
96 hours at temperature of 40ç and humidity of 90% to 95%.  
18.Humidity  
Complete dust protection. No water penetration  
19.Water / dust protection  
When mated with corresponding connector.  
when submerged for 48 hours at the depth of 1.8 meter.  
Note 1: Includes temperature rise caused by the current flow.  
Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature range  
and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation.  
Materials / Finish  
Components  
Body / back shell  
Insulator  
Material  
Zinc alloy  
Finish / Color  
Nickel plated  
Black  
Remarks  
––––––––––  
UL94V-0  
––––––––––  
––––––––––  
PPS  
Contacts  
Copper alloy  
Chloroprene rubber  
Gold plated  
Black  
Gasket  
Ordering Information  
Series name  
: LF  
1
2
Shell size  
07  
10  
13  
Waterproof  
W : Waterproof type  
B : Bayonet lock  
P : Plug  
3
4
5
-
-
LF 07 W B P 6 S  
Lock Mechanism  
Connector type  
1
2
3
4
5
6
7
R : Receptacle  
J : Jack  
Number of contacts  
Contact type  
: 3, 4, 6, 11, 12, 20  
P : Male contact  
S : Female contact  
6
7
2
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Plugs  
B
(Shown one example)  
Unit:mm  
Part number  
LF07WBP-3S  
LF07WBP-3P  
LF07WBP-6S  
LF07WBP-6P  
LF10WBP-4S  
LF10WBP-4P  
LF10WBP-12S  
LF10WBP-12P  
LF13WBP-20S  
LF13WBP-20P  
LF13WBP-11S  
LF13WBP-11P  
CL No.  
Contact Number of contacts  
ØA  
B
ØC  
5
Weight RoHS  
136-0003-7  
136-0004-0  
136-0001-1  
136-0002-4  
136-0005-2  
136-0006-5  
136-0007-8  
136-0008-0  
136-0009-3  
136-0010-2  
136-0011-5  
136-0012-8  
Female  
3
Male  
12.3  
35.3  
11g  
Female  
6
Male  
Female  
4
Male  
14.8  
17.9  
41.8  
51.9  
7.3  
8.7  
17g  
29g  
YES  
Female  
12  
Male  
Female  
20  
Male  
Female  
11  
Male  
Receptacles  
C
D
E
F(HEX)  
(Shown one example)  
Unit:mm  
Part number  
LF07WBR-3P  
LF07WBR-3S  
LF07WBR-6P  
LF07WBR-6S  
LF10WBR-4P  
LF10WBR-4S  
LF10WBR-12P  
LF10WBR-12S  
LF13WBR-20P  
LF13WBR-20S  
LF13WBR-11P  
LF13WBR-11S  
CL No.  
Contact Number of contacts  
ØA  
ØB  
13  
C
D
E
F
Weight RoHS  
136-1003-2  
136-1004-5  
136-1001-7  
136-1002-0  
136-1005-8  
136-1006-0  
136-1007-3  
136-1008-6  
136-1009-9  
136-1010-8  
136-1011-0  
136-1012-3  
Male  
3
6
4
15.15  
Female  
10.3  
7.65 1M9∞0.75  
7.75 M11∞0.75  
11  
4g  
Male  
15.05  
15.25  
Female  
Male  
19.05  
17.25  
6g  
Female  
12.8  
15.9  
15.3  
18.3  
13  
17  
YES  
5g  
Male  
12  
Female  
6g  
9g  
Male  
20  
10g  
9g  
Female  
19.05 7.75  
M14∞0.75  
Male  
11  
10g  
Female  
Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.)  
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Jacks  
C
(Shown one example)  
Unit:mm  
Part number  
LF07WBJ-3P  
LF07WBJ-3S  
LF07WBJ-6P  
LF07WBJ-6S  
LF10WBJ-4P  
LF10WBJ-4S  
LF10WBJ-12P  
LF10WBJ-12S  
LF13WBJ-20P  
LF13WBJ-20S  
LF13WBJ-11P  
LF13WBJ-11S  
CL No.  
Contact Number of contacts  
ØA  
ØB  
C
ØD  
5.0  
Weight RoHS  
136-2003-8  
136-2004-0  
136-2001-2  
136-2002-5  
136-2005-3  
136-2006-6  
136-2007-9  
136-2008-1  
136-2009-4  
136-2010-3  
136-2011-6  
136-2012-9  
Male  
3
Female  
10.3  
11.5  
36.3  
11g  
Male  
6
Female  
Male  
4
Female  
12.8  
15.9  
13.8  
16.9  
42.4  
52.4  
7.3  
8.7  
16g  
YES  
Male  
12  
Female  
Male  
29g  
30g  
29g  
30g  
20  
Female  
Male  
11  
Female  
4
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Applicable tools  
Unit:mm  
Description  
Part number  
CL No.  
LF series Applicable cable dia.  
5 (Note)  
HR10A-TC-02 150-0041-2  
Manual cable clamp crimp  
LF-TC-01  
150-0234-6  
7.3 · 8.7  
Note: Applicable cable dia. is only 5mm for LF series.  
Solder termination fixture  
Part number  
CL No.  
Applicable connectors  
LF07BP-T01  
LF07BJ-T01  
LF10BP-T01  
LF10BJ-T01  
LF13BP-T01  
LF13BJ-T01  
150-0232-0  
150-0233-3  
150-0235-9  
150-0236-1  
150-0237-4  
150-0238-7  
LF07WBP-6S,6P,3S,3P  
LF07WBJ-6S,6P,3S,3P  
LF10WBP-4S,4P,12S,12P  
LF10WBJ-4S,4P,12S,12P  
LF13WBP-20S,20P,11S,11P  
LF13WBJ-20S,20P,11S,11P  
Panel Cutout  
Alignment guide  
unit (mm)  
Shell size  
LF07  
A
B
Panel thickness  
Ø9.05  
Ø11.05  
Ø14.05  
8.1  
0.5 to 2  
0.7 to 2  
0.7 to 2  
LF10  
10.2  
13.1  
LF13  
B+0.05  
0
Contact position arrangement and specifications  
Shell size  
LF07  
LF10  
LF13  
1
8
1
9
B
C
2
3
4
5
1
3
6
4
2
8
10  
4
3
1
2
6
7
9 10  
3
1
A
D
Contact configuration  
5
2
11 12 13 14 15  
16 17 18 19  
20  
3
7
12 11  
2
3
2
1
4
6
4
5
5
6
7
Number of contacts  
Withstanding voltage  
Current rating  
3
6
4
12  
11  
20  
4
7
1250V AC  
5A  
300V AC  
2A  
1250V AC  
10A  
300V AC  
2A  
AC300V  
2A  
AC1250V  
4
10A  
AC300V  
7
2A  
Insulation resistance  
Contact resistance  
Solder pot inner diameter  
1000Mø  
15mø  
1000Mø  
5mø  
1000Mø  
15mø  
1000Mø  
1000Mø  
4mø  
4
7
15mø  
7
5mø  
4
1.15mm  
0.8mm  
1.7mm  
0.8mm  
0.8mm  
Ø
Ø
1.7  
0.8  
Note 1: The contact configuration as viewed from the female contact connector mating side.  
Note 2: The symbol indicates polarizing key position.  
Note 3: Withstanding voltages are test voltage values.  
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Termination and Assembly Instructions  
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.  
Operation  
Illustration  
No.  
Plug disassembly  
Solder termination fixture  
1
1
Plug  
Insert the plug into securely held solder  
termination fixture as shown.  
1
Fixture Part No.  
Applicable connector  
LF07BP-T01 LF07WBP-6S,6P,3S,3P  
LF10BP-T01 LF10WBP-4S,4P,12S,12P  
LF13BP-T01 LF13WBP-20S,20P,11S,11P  
Locking collar  
Insertion direction  
Body / insulator assembly  
Backshell  
Loosen the backshell turning it counter  
clockwise and remove it from the body/  
insulator assembly.  
2
2
Solder termination fixture  
Jack  
Jack Disassembly  
1
2
Insert the jack into the securely held solder  
termination fixture as shown.  
1
Fixture Part No.  
Applicable connector  
LF07BJ-T01 LF07WBJ-6S,6P,3S,3P  
LF10BJ-T01 LF10WBJ-4S,4P,12S,12P  
LF13BJ-T01 LF13WBJ-20S,20P,11S,11P  
Insertion direction  
Body / insulator assembly  
Loosen the backshell turning it  
counterclockwise.  
2
Backshell  
Connector Assembly  
Backshell  
1
2
Apply a coating of Loctite 7649  
1
(Manufactured by Henckel Japan, Ltd,)  
primer to the threaded sections of the  
backshell and the tightening collar.  
Completely dry the coated surfaces.  
Note  
Threaded section  
Threaded section  
(1)  
(2)  
(3)  
Drying time at room temperature is  
approximately 30 to 70 seconds.  
Ensure sufficient ventilation of the area at  
time of drying.  
Take necessary steps to protect the coated  
surfaces from contamination.  
Tightening collar  
6
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Operation  
Illustration  
No.  
Thread the tightening collar, strain relief collar,  
seal bushing and the backshell over the cable  
as illustrated.  
2
2
2
Strain relief collar  
Tightening collar  
Backshell  
Cable  
Seal bushing  
Cable preparation end  
Cable preparation  
A
1
3
Cable outer jacket  
Strip the cable’s outer jacket to the dimensions  
illustrated in the table 1.  
1
Shielding mesh  
Table 1. Stripping Dimensions  
Note  
(1)  
(2)  
Exercise caution not to damage the shielding  
mesh.  
Any damage to the cable’s outer jacket may  
affect the waterproof performance of the  
assembled connector.  
Number of Conductors  
3
A mm  
8 to 9  
6
4
12  
13 to 14  
14 to 15  
22 to 23 (No.A to D)  
23 to 24 (No.1 to 7)  
23 to 24  
11  
20  
Fold back the shielding mesh over the cable’s  
outer jacket assuring that it is uniform on its  
diameter.  
2
2
Shielding mesh  
Cable outer jacket  
Wires  
Shielding mesh  
(Folded back)  
4 to 5mm  
Wires  
Cable outer jacket  
Stripping dimensions  
Wires  
3
Strip the wires to the dimensions illustrated in  
the Table 2.  
3
Cable outer jacket  
B
Note  
When stripping the wires exercise caution not  
to damage it’s insulation, folded over  
shielding mesh or cable’s outer jacket.  
Conductors  
Table 2. Stripping Dimensions  
Number of Conductors  
3
B mm  
2.5 0.5  
2
3
2
0.5  
0.5  
0.5  
6
4
12  
3
2
0.5 (No.A to D)  
0.5 (No.1 to 7)  
11  
20  
2
0.5  
7
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Operation  
Illustration  
No.  
Soldering  
4
Soldering conditions  
1
Soldering iron tip temperature: 350 10ç  
Soldering time: within 5 sec.  
Note  
(1)  
Assure that the solder compound is  
sufficiently melted on the soldering iron tip.  
When applying, make sure that the solder will  
flow correctly at all the contact surfaces  
between the conductor and the contact.  
(2)  
Cmm  
– 1  
– 1 6, 12, 20, 11(No.1~7) Conductors  
2
2
Wire  
Insulator  
(1)  
Place a heat-shrink tubing (inside diameter of  
1.1 mm min.) over every other wire.  
Perform the soldering of the contact and the  
conductor, with the wire’s insulation touching  
the contact as shown.  
After soldering, slide the heat shrink tubing  
over the soldered joint and shrink it. The  
tubing should touch the insulator as shown.  
Contact  
(2)  
(3)  
Table 3  
Number of  
Conductors  
Number of  
contacts  
C mm  
6
1 to 6  
1 to 9  
10 to 12  
1 to 5,16 to 20  
6 to 15  
4
4
6
4
6
6
4
12  
Heat-shrink tubing  
20  
11  
1 to 4  
5 to 7  
Insulator  
– 2 3, 4, 11(No.A~D) Conductors  
2
(1)  
– 2  
2
Insulator wall  
Perform the soldering of the contact and the  
conductor, with the wire’s insulation touching  
the contact as illustrated.  
(2)  
When soldering, to maintain the insulation  
between adjacent contacts. Make sure that  
the wire’s insulation remains below the edge  
of the insulator’s wall 0.5 mm min., as  
illustrated.  
Contact  
Insulator wall  
Insulator  
Wire insulation  
Contact  
Wire insulation  
Solder  
0.5 mm min.  
3
Cable outer jacket  
3
After the soldering, keep a distance of D  
between the contact end and the cable’s  
outer jacket as illustrated.  
D
Note  
Shielding mesh  
(Folded back)  
The distance of D is required in order to  
assure correct assembly of the backshell.  
Table 4. Wire Dimensions  
Number of Conductors  
D mm  
3
6
6 to 7  
4
10 to 11  
13 to 14  
12  
11  
20  
18 to 19  
8
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Operation  
Illustration  
No.  
Crimping of the Shielding Clamp  
1
5
Solder termination fixture  
After completion of the soldering operations  
carefully remove (holding on the locking collar)  
the body/insulator assembly from the solder  
termination fixture.  
1
Body / insulator assembly  
Note  
Soldered joints  
Exercise caution not to damage or deform the  
solder joints.  
Cable outer jacket  
Copper tape  
2
2
Wrap the folded over shielding mesh with 5 to  
6 mm wide copper tape to assure that it will  
not become loose.  
Cable outer jacket  
Wires  
Apply the copper tape so that the shielding  
mesh does not protrude from under it.  
Note  
Shielding mesh  
5 to 6mm  
Copper tape  
After wrapping the copper tape, the tape  
should overlap itself by 2 mm max.  
Insert the “U” shaped shielding clamp over the  
copper tape as shown on the illustration.  
It is critical that the overlap of the copper tape  
is located inside the shielding clamp as shown  
on the illustration.  
3
3
Cable outer jacket  
1 0.5mm  
Copper tape  
Ground clamp  
Copper tape  
Cable outer jacket  
Note  
When the end of the copper tape wrapping is  
positioned at the open side of the ground  
fitting, the end portion of the copper tape  
wrapping will no longer be covered by the  
ground fitting when the ground fitting is  
crimped.  
Wires  
Shielding clamp  
Shielding mesh  
Overlap of the copper tape  
4
Using commercially available pliers bend the  
open ends of the shielding clamp as illustrated,  
assuring that it stays in place. The dimension  
of E. between opposing edges of the shielding  
clamp is necessary to assure correct final  
crimp.  
4
Commercially  
available pliers  
E
Table 5  
Shell size  
E
Shielding clamp  
Overlap of the copper tape  
LF07  
LF10  
LF13  
5mm max.  
7mm max.  
9
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Operation  
Illustration  
No.  
Crimping tool  
Both sides of the shielding clamp must be  
placed in the forming cavity of the tool  
(as shown on the illustration) and crimped  
over the cable by closing the tool completely.  
5
5
5
Forming cavity  
Applicable cable  
diameter  
Shielding clamp  
Crimping tool Forming cavity  
diameter after crimping  
5.3mm to  
5.5mm  
5mm  
–––  
5.3  
HR10A-TC-02  
7.0  
–––  
7.9mm to  
8.1mm  
9.1mm to  
9.3mm  
7.3mm  
8.7mm  
7.9  
LF-TC-01  
9.1  
Connector Assembly  
1
2
6
,
Place the body/insulator assembly in the  
applicable solder termination fixture.  
For plug assembly  
1
2
Threaded section  
Backshell  
Applicable connector  
LF07WBP-6S,6P,3S,3P  
LF10WBP-4S,4P,12S,12P  
LF13WBP-20S,20P,11S,11P  
Fixture Part No.  
LF07BP-T01  
LF10BP-T01  
LF13BP-T01  
For jack assembly  
Fixture Part No.  
LF07BJ-T01  
Applicable connector  
LF07WBJ-6S,6P,3S,3P  
LF10WBJ-4S,4P,12S,12P  
LF13WBJ-20S,20P,11S,11P  
LF10BJ-T01  
LF13BJ-T01  
Coat the thread section of the body/insulator  
assembly with Loctite 271 compound  
(manufactured by Henckel Japan, Ltd.) or  
equivalent, tightening it with a torque  
specified in the table 6.  
Wrench width : D  
Table 6  
Shell size Tightening torque Wrench width  
·
·
1N m~1.5N m  
10mm  
13mm  
16mm  
LF07  
LF10  
LF13  
Note  
·
·
1N m~1.5N m  
It is critical that the cable itself will not turn or  
twist during this operation.  
·
·
1.5N m~2N m  
3
4
Slide forward the seal bushing and insert it in  
the backshell until fully seated.  
3
4
,
Seal bushing  
Strain relief collar  
Slide forward the strain relief collar and insert  
it in the backshell, making sure that the  
opposing protrusions fit inside the  
corresponding grooves, as shown on the  
illustration.  
Protrusion  
Tightening collar  
Groove  
Note  
It is critical that the protrusions are inside the  
corresponding grooves.  
5
5 Verify that the Locktite 7649 primer  
(or equivalent) on the threaded sections of the  
backshell and tightening collar are dry.  
Apply the Locktite 271 compound to the  
tightening collar’s threaded section and attach  
it to the backshell.  
Threaded section  
Tightening collar  
10  
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.  
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.  
LF SeriesMiniature Waterproof Shielded Connectors  
Operation  
Illustration  
No.  
6
6
Remove the connector from the solder  
termination fixture, holding it by the locking  
collar. Do not pull on the cable.  
Tightening collar  
Wrench width  
6
Shell size Tightening torque Wrench width  
·
·
0.8N m~1N m  
10mm  
13mm  
16mm  
LF07  
LF10  
LF13  
·
·
0.7N m~1N m  
·
·
1 N m~1.5 N m  
1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter.  
2. Consult HRS representative when using different cables.  
Cable Specifications (Reference)  
No. of contact  
Material  
3 pos.  
Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire  
Ø0.18 Ø0.26 Ø0.16 Ø0.16 Ø0.16  
4 pos.  
6 pos.  
12 pos.  
20 pos.  
11 pos.  
Soft copper wire Soft copper wire  
Size (mm)  
Ø0.26  
Ø0.16  
Construction  
Size (AWG)  
20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia.  
AWG #20  
AWG #16  
1.25  
AWG #26  
–––––––  
Ø0.48  
AWG #26  
0.14  
AWG #26  
0.14  
AWG #16 AWG #26  
Sectional area –––––––  
Diameter (mm) Ø0.98  
1.25  
Ø1.5  
0.14  
Ø1.5  
Ø0.48  
Ø0.48  
Ø0.48  
Diameter (mm) Ø1.5 (Standard)  
Thickness (mm) 0.26  
Ø2.1 (Standard)  
0.3  
Ø0.88 (Standard) Ø0.9 (Standard)  
0.2 0.21  
Ø0.9 (Standard)  
0.21  
Ø2.1 (Standard) Ø0.95 (Standard)  
0.3  
0.235  
Material  
Density  
Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire  
85%  
80%  
Ø5.5  
85%  
Ø3.4  
80%  
Ø4.2  
80%  
Ø5.1  
80%  
Ø6.7  
Diameter (mm) Ø3.6  
Diameter (mm) Ø5 0.2  
Ø7.3 0.2  
Ø5 0.2  
Ø7.3 0.2  
Ø8.7 0.2  
Ø8.7 0.2  
11  

相关型号:

LF07-WBJ-6P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBJ-6S

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-11P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-11S

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-12P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-12S

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-20P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-20S

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-3P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-3S

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-4P

Miniature Waterproof Shielded Connectors
HRS

LF07-WBP-4S

Miniature Waterproof Shielded Connectors
HRS