HRFC-R2 [HRS]

FC Type Fiber Optic Connectors; FC型光纤连接器
HRFC-R2
型号: HRFC-R2
厂家: HRS    HRS
描述:

FC Type Fiber Optic Connectors
FC型光纤连接器

光纤 连接器 光纤连接器 光纤FC连接器
文件: 总8页 (文件大小:341K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FC Type Fiber Optic Connectors  
HRFC Series  
Features  
1. JIS, IEC standards compliantand and fully intermateable with NTT's FC products.  
JIC C 5970 (F01 type fiber optic connectors).  
IEC 61754-13  
2. Two types of plug frames  
Conventional cutout key ring types and molded key ring types are available.  
Important Notice  
Plug key width : 2.1mm  
Adapter key width : 2.2mm  
Applications  
Public communications lines, CATV, Test equipment, etc.  
47  
Product Specifications  
Ratings  
Operating temperature range  
-25°C to +70°C  
Storage temperature range  
-25°C to +70°C  
Item  
Test Method (IEC 61300)  
Specifications  
(SM)  
(GI)  
Wavelength 1310nm (LD)  
0.5dB max. (PC, AdPC, APC)  
0.3dB max. (PC)  
Insertion Loss  
Return Loss  
Wavelength 1310nm (LED)  
(SM)  
(GI)  
22dB min.(PC) 40dB min.(AdPC) 60dB min. (APC)  
22dB min. (PC)  
Wavelength 1310nm (LD)  
Extract Zirconia gauge 2.499 ±0.0005 mm  
dia from split sleeve.  
Copper alloy split sleeve  
Zirconia split sleeve  
2N to 5.9N  
2N to 3.9N  
Ferrule withdrawal  
Cable retention  
(Straight pull)  
1) Insertion loss fluctuation after test: 0.2dB max.  
2) No visible damage, dislocation of clamp or cable.  
98N tensile load for minute.  
1000 times  
Durability  
(cycles, mating/un-mating)  
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,  
2 hours in each of the 3 axis.  
Vibration  
Acceleration of 981 m/s2, 6 ms duration,  
Shock  
sin half-wave waveform, 10 cycles in each of the 3 axis.  
1) Insertion loss fluctuation after test: 0.2dB max.  
2) No visible damage, cracks or part dislocation.  
Humidity  
(Temperature/ humidity- cycles)  
-10°C to 65°C, humidity: 90% to 96% 20 cycles  
-40°C to +70°C 42 cycles  
(Complies with Telcordia standard GR-326-CORE)  
Change of temperature  
Dry heat  
Cold  
960 hours at 85°C  
960 hours at -25°C  
Salt mist  
48 hours in a 5% concentration of salt mist  
No significant corrosion.  
Materials  
Part  
Plug housing  
Spring  
Material  
Brass, Stainless steel or Zinc alloy  
Stainless steel  
Zirconia  
Ferrule  
Adapter  
Brass  
Split sleeve  
Receptacle  
Attenuator housing  
Copper alloy  
Brass  
Stainless steel  
48  
FC products  
For 2 mm cable,  
Molded keying ring type  
Cutout keying ring type  
Cutout keying ring type  
Cutout keying ring type  
Plug Housing  
Key width 2.1mm  
For 3 mm cable,  
Molded keying ring type  
For 0.9 mm fiber,  
Molded keying ring type  
Single mode  
Multi mode  
Ferrule  
Adapter  
Key width 2.2mm  
Standard type  
Round type  
FC to SC  
Solid Body type  
HRFC-type  
Connector  
Flange type  
FC to SC  
Conversion adapter  
Receptacle  
Dust cap  
Fixed type  
Attenuator  
Single mode  
GI  
Variable type  
Single mode  
Terminator  
49  
Molded keying ring type (Key width 2.1mm)  
52.8  
For 2mm cable  
Part Number  
CL No.  
Boot color  
Polishing type  
PC  
HRFC-P8-H2(21)  
HRFC-P8-L2(21)  
HRFC-P8-G2(21)  
701-0075-3-21  
701-0077-9-21  
701-2001-8-21  
Blue  
Light purple  
Green  
AdPC  
APC  
52.8  
For 3mm cable  
Part Number  
CL No.  
Boot color  
Blue  
Polishing type  
PC  
HRFC-P8-H3(21)  
HRFC-P8-L3(21)  
HRFC-P8-G3(21)  
701-0074-0-21  
701-0078-1-21  
701-2002-0-21  
Light purple  
Green  
AdPC  
APC  
For 0.9mm fiber  
30.8  
Part Number  
CL No.  
Boot color  
Blue  
Polishing type  
PC  
HRFC-P15-H(21)  
HRFC-P15-L(21)  
HRFC-P15-G(21)  
701-0114-3-21  
701-0115-6-21  
701-2004-6-21  
Light purple  
Green  
AdPC  
APC  
Tool  
Crimp tool  
Part Number  
HSC-T3  
CL No.  
Applicable connector  
HRFC-P8-H2,L2,G2,  
HRFC-P8-H3,L3,G3,  
704-0287-0  
<Locations>  
(1)2mm Jacket crimping: section A  
3mm Jacket crimping: section C  
(2)KevlarTM crimping: section B  
50  
Cutout keying ring type (Key width 2.1mm)  
For 2mm cable  
37.8  
Part Number  
CL No.  
HRFC-P1-H(04)  
701-0001-7-04  
For 3mm cable  
37.8  
Part Number  
HRFC-P1-H  
CLNo.  
701-0001-7  
For 0.9mm fiber  
27.8  
Part Number  
HRFC-P6-H  
CL No.  
701-0041-1  
51  
Adapters (Key width 2.2mm)  
Solid Body type  
15  
9.5  
15  
4
M8∞0.75  
M8∞0.75  
BPanel Cutout  
+0.5  
0
Ø9  
2-M20.4  
+0.2  
0
or 2-Ø2.4  
13.4 0.1  
Board thiekness : 16mm  
Part Number  
HRFC-PA11-G1  
HRFC-PA11-D1  
CL No.  
Split sleeve  
Copper alloy  
Zirconia  
Remarks  
701-0071-2  
701-0106-5  
(Note)  
Note:Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to  
the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged.  
Standard Body type  
15  
4
15  
BPanel Cutout  
Ø9+0.5  
9.5  
0
2--M8∞0.75  
2--M2∞0.4  
or 2--Ø2.4 +0.2  
0
Ø2.2  
13.4 0.1  
Ø4 Countersink depth 1.5  
Board thiekness : 16mm  
Mark  
Part Number  
CL No  
Split sleeve  
Remarks  
HRFC-PA1-G1(02)  
HRFC-PA1-D1(02)  
701-0014-9-02  
701-0089-8-02  
FC-AP Copper alloy  
FC-AA Zirconia  
(Note)  
Note:Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to  
the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged.  
15  
2
Flange type  
BPanel Cutout  
Ø9+0.5  
2--M8∞0.75  
0
2--M2∞0.4  
or 2--Ø2.4 +0.2  
0
2- Ø2.2  
2--Ø4 Countersink depth 1.5  
13.4 0.1  
Part Number  
HRFC-PA4-G1  
HRFC-PA4-D1  
CL No.  
Split sleeve  
Copper alloy  
Zirconia  
Remarks  
(Note)  
701-0068-8  
701-0112-8  
Note:Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to  
the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged.  
Round type  
15  
2-M 8×0.75  
Part Number  
HRFC-A2-SF(01)  
HRFC-A2-SF-D1  
CL No.  
701-0039-0-01  
-----  
Split sleeve  
Copper alloy  
Zirconia  
Remarks  
(Note)  
Note:Please take utmost care when inserting FC plug into a FC adapter. When applying excessive force to  
the FC plug or inserting in an odd angle, the zirconia sleeve within the adapter might be dameged.  
52  
Conversion adapters  
BPanel Cutout  
FC / SC  
21.2  
5.5 3.5 12.2  
Ø9+0.5  
0
2--M8∞0.75  
2--M2∞0.4  
or 2--Ø2.4 +0.2  
0
13.4 0.1  
9
13.4  
Board thiekness : 16mm  
Split sleeve  
Part Number  
CL No.  
Copper alloy  
HSCJ-HRFCJ-B(51)  
704-0021-3-51  
FC / SC  
13.7  
9
12.8  
(3.9)  
32  
Part Number  
CL No.  
701-0065-0-51  
HRFCP-HSCJ-1AS(51) 701-0108-0-51  
HRFCP-HSCJ-2(51) 701-0085-7-51  
HRFCP-HSCJ-2AS(51) 701-0109-3-51  
Split sleeve  
Copper alloy  
Polishing type Fiber type  
PC  
HRFCP-HSCJ-1(51)  
GI-50/125  
AdPC  
PC  
SM-9.5/125  
AdPC  
FC / SC  
M8∞0.75  
7.4  
9.4  
21  
27.9  
(1.8)  
Part Number  
CL No.  
Split sleeve  
Copper alloy  
Polishing type Fiber type  
(
)
HSCP-HRFCJ-1 51  
704-0203-0-51  
704-0288-3-51  
704-0204-3-51  
704-0289-6-51  
PC  
GI-50/125  
AdPC  
(
)
)
HSCP-HRFCJ-1AS 51  
(
)
HSCP-HRFCJ-2 51  
PC  
SM-9.5/125  
AdPC  
(
HSCP-HRFCJ-2AS 51  
BPanel Cutout  
9
M15  
Ø9+0.5  
0
3
5.5  
Receptacle  
M9.5  
4--M2∞0.4  
or 4--Ø2.4 +0.2  
M8∞0.75  
0
4-Ø2.2  
Ø4 Countersink depth 1.5  
9.5 0.1  
Part Number  
HRFC-R1  
HRFC-R2  
HRS No.  
Remarks  
MM  
701-0016-4  
701-0023-0  
SM  
53  
Ferrule  
Same as SC ferrules  
Refer to page 33 for details.  
Dust Cap  
Part Number  
HRFC-C1  
CL No.  
701-0019-2  
54  

相关型号:

HRFC-R2(40)

Fiber Optic FC Connector
HRS

HRFC-R2(41)

Fiber Optic FC Connector
HRS

HRFC-SP1-F1A-L

Fiber Optic FC Connector, 9.5/125um, Single Mode, Simplex
HRS

HRFC-SP2-F1A-L

Fiber Optic FC Connector, 9.5/125um, Single Mode, Simplex
HRS

HRFC-SP2-F3A-L

Interconnection Device
HRS

HRFC-SP2-F3B-L

Interconnection Device
HRS

HRFC-SP2-F3P-L

Interconnection Device
HRS

HRFC-SP2-F3Q-L

Interconnection Device
HRS

HRFC-SP72-F3P-1M(51)

Interconnection Device
HRS

HRFC-SP72-F3P-2M(52)

Interconnection Device
HRS

HRFC-SP72-F3P-3M(53)

Interconnection Device
HRS

HRFC-TM-P1

Optical Terminators
HRS