HIF3-34CVFA [HRS]

Cover (HIF3B Series) against EMI (Electromagnetic Interference); 封面( HIF3B系列)对EMI(电磁干扰)
HIF3-34CVFA
型号: HIF3-34CVFA
厂家: HRS    HRS
描述:

Cover (HIF3B Series) against EMI (Electromagnetic Interference)
封面( HIF3B系列)对EMI(电磁干扰)

文件: 总5页 (文件大小:240K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Cover (HIF3B Series) against EMI (Electromagnetic Interference)  
Features  
1. Electromagnetic Shielding Effect  
Applications  
Peripheral and termination equipment, control machines, measuring  
instruments etc.  
This product enhances shielding effects with a metallic cover  
over the ribbon cable connector (HIF3B series).  
Ordering Information  
2. Screw Locking Mechanism  
The locking mechanism is designed in a stubborn and  
steady structure for the screw type.  
3. Assembling  
HIF 3 - * CVFA  
The ribbon cable connector (HIF3B series) can be easily  
assembled.  
q
w
e
q Series Name  
: HIF 3  
w Number of contacts : 10, 16, 20, 26, 30, 34, 40, 50, 64  
e CVFA  
: Cover case for EMI  
I/O Cable Termination  
Material  
Material  
Zinc alloy  
Finish  
Nickel plated  
As shown above, bend the shield knitted cord, wind  
the conductive tape 1 to 2 turns, and finish cable  
termination so as not to loosen the shield knitted cord.  
B45  
Cover  
Unit : mm  
D E  
Part Number  
HIF3-10CVFA  
HIF3-16CVFA  
HIF3-20CVFA  
HIF3-26CVFA  
HIF3-30CVFA  
HIF3-34CVFA  
HIF3-40CVFA  
HIF3-50CVFA  
HIF3-64CVFA  
CL No.  
Number of Contacts  
A
8.5  
7.8  
9.0  
10.0  
9.2  
B
C
612-0061-4  
612-0062-7  
612-0063-0  
612-0064-2  
612-0065-5  
612-0066-8  
612-0067-0  
612-0068-3  
612-0070-5  
10  
16  
20  
26  
30  
34  
40  
50  
64  
8.0 31.7  
7.8 34.9  
38.12 17.52  
41.32 25.14  
8.5 39.98 46.4 30.22  
9.5 47.6 54.02 37.84  
9.2 52.68 59.1 42.92  
11.0 10.0 57.76 64.18 48.0  
13.0 10.0 65.38 71.8 55.62  
14.5 10.0 78.08 84.5 68.32  
15.4 10.0 95.86 102.7 86.1  
B46  
Applicable Socket Connector  
Notes1 and 2: The number of polarizing guide and keys change according to products.  
Unit : mm  
Polarizing keyway  
One at center  
Part Number  
CL No.  
Number of Contacts  
A
B
C
D
Polarizing guide  
HIF3BA-10D-2.54R-CL(21) 610-0190-4-21  
HIF3BA-16D-2.54R-CL(21) 610-0192-0-21  
HIF3BA-20D-2.54R-CL(21) 610-0193-2-21  
HIF3BA-26D-2.54R-CL(21) 610-0194-5-21  
HIF3BA-30D-2.54R-CL(21) 610-0195-8-21  
HIF3BA-34D-2.54R-CL(21) 610-0196-0-21  
HIF3BA-40D-2.54R-CL(21) 610-0197-3-21  
HIF3BA-50D-2.54R-CL(21) 610-0198-6-21  
HIF3BB-50D-2.54R-CL(21) 610-0201-9-21  
HIF3BA-64D-2.54R-CL(21) 610-0200-6-21  
HIF3BB-64D-2.54R-CL(21) 610-0203-4-21  
10  
16  
20  
26  
30  
34  
40  
50  
50  
64  
64  
17.27 10.16 11.43 12.8  
24.89 17.78 19.05 20.42  
29.97 22.86 24.13 25.5  
37.59 30.48 31.75 33.12  
42.67 35.56 36.83 38.2  
47.75 40.64 41.91 43.28  
55.37 48.26 49.53 50.9  
68.07 60.96 62.23 63.6  
68.07 60.96 62.23 63.6  
85.85 78.74 80.01 81.38  
85.85 78.74 80.01 81.38  
One at center  
One on right and left sides, resp.  
One on right and left sides, resp.  
One at center  
One on right and left sides, resp  
One at center  
Pin Header  
The pin header applicable to the socket connector HIF series can wholly use the HIF3 series. It is recommended to  
use following products, considering positioning (protection of mating area) when the connector is engaged.  
(
)
In addition, when the connector is installed, the locking mechanism is removed. If needed, order the product 11  
according to the specification (unlock), as shown below.  
(
)
)
)
HIF3B *PA 2.54DS,DSA 11  
Note:  
(
(
)
HIF3BA *PA 2.54DS,DSA 11  
HIF3B *PA 2.54DS, DSA 11 is limited  
to number of contacts as follows:  
DSA-20, 30, 34, 40 contacts  
DSA-26, 50 contacts  
(
HIF3BB *PA 2.54DS,DSA 11  
B47  
Recommended Panel catouts  
Number of Contacts  
A
B
C
D
10  
16  
20  
26  
30  
34  
40  
50  
64  
18.52 31.7 10.16 21.8  
26.14 34.9 17.78 29.5  
31.22 39.98 22.86 34.5  
38.84 47.6 30.48 42.2  
43.92 52.68 35.56 47.2  
49.0 57.76 40.64 52.3  
56.62 65.38 48.26 59.9  
69.32 78.08 60.96 72.6  
87.1 95.86 78.74 90.4  
Right Angle Type  
HIF3B-*PA-DS(11) 3.45  
3BA  
3BB  
HIF  
-*PA-DS(11) 4.75  
B48  
Cover Assembling Procedures  
4
5
2
1
6
3
1
7
8
3
BAssembling Procedures  
1. Insert the connected connector (cable shield cable after termination process) 1 in the adapter metal 2, and  
connect the assembly to the cover A 3.  
2. Insert the cable unit 1 in the clamp slot of cover A 3, and mount the clamp metal 4. Then, tighten the unit by  
screws.  
3. Next, place the lock screw 5 in the right slot, and mount the cover B 7 so as not to bite the cable, and tighten the  
assembly by screws. At this time, check that no clearance is found between cover A and B.  
B49  

相关型号:

HIF3-40CV

Ribbon Cable connector Compliant with MIL Standard
HRS

HIF3-40CV(71)

Connector Accessory, Cover Item, ROHS COMPLIANT
HRS

HIF3-40CV(72)

COVER CASE CRIMPING SOCKET 40POS
HRS

HIF3-40CVFA

Cover (HIF3B Series) against EMI (Electromagnetic Interference)
HRS

HIF3-50CV

Ribbon Cable connector Compliant with MIL Standard
HRS

HIF3-50CVFA

Cover (HIF3B Series) against EMI (Electromagnetic Interference)
HRS

HIF3-60CV

Ribbon Cable connector Compliant with MIL Standard
HRS

HIF3-60CV(71)

Connector Accessory, Cover Item, ROHS COMPLIANT
HRS

HIF3-64CVFA

Cover (HIF3B Series) against EMI (Electromagnetic Interference)
HRS

HIF3-6PA-2.54DSA

Board Connector, 6 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Latch & Eject, Black Insulator, Receptacle
HRS

HIF3-6PA-2.54DSA(71)

Board Connector, 6 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, ROHS COMPLIANT
HRS

HIF3-C

Telecom and Datacom Connector, 10 Contact(s), Female, IDC Terminal, Socket
HRS