G7555A [HP]

SureGuide CRISPR Libraries;
G7555A
型号: G7555A
厂家: HEWLETT-PACKARD    HEWLETT-PACKARD
描述:

SureGuide CRISPR Libraries

文件: 总2页 (文件大小:210K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SureGuide CRISPR Libraries  
GeCKOv2 Catalog Libraries  
Benefits  
SureGuide CRISPR Libraries  
SureGuide Catalog CRISPR Libraries  
Agilent’s pooled libraries come in a variety of formats designed to suit your unique  
experimental requirements. Pooled libraries require both uniform representation  
and high fidelity to reduce screening, improve analysis and speed your time to  
results. All of our libraries, whether standard, genome-wide content or fully  
customized pools, are synthesized on our industry-leading DNA manufacturing  
system, so you can be sure of getting the same quality and consistency out  
of every assay. Our CRISPR libraries are also one of the few licensed solutions  
for conducting research with pooled guide libraries, making sure that you have  
not only the best libraries available but the freedom to use them for the research  
you’ve designed.  
Exome-wide knock-down screening -  
Validated guides targeting all known  
genes  
Highest quality, sequence-verified  
GeCKOv2 libraries  
Lentiviral, ready-to-package plasmid  
libraries  
Human and mouse libraries - Common  
model organisms/cell lines for genome-  
wide screening  
Catalog Ready-to-Package Plasmid Library  
Agilent’s catalog CRISPR guide libraries target all exonic sequences in the human  
and mouse genome and are ideal for genome-wide functional screening. These  
libraries contain content developed by and licensed by a well known research  
institute. In comparison to other GeCKO libraries, Agilent’s GeCKO libraries  
contain fewer missed guides and more uniform representation across the  
library (Table 1). Both the mouse and human GeCKO libraries come as plasmids,  
with a puromycin selection marker and a GFP reporter, that can be used to  
generate high-titers of lentiviral particles.  
Full flexibility to develop your research  
applications  
Integration of SureGuide CRISPR library in Genomics Assay Workflow  
OLS Library  
PCR amplify  
Clone into  
viral vector  
Transform  
E. coli host  
Isolate  
plasmid DNA  
Transfect  
packaging line  
Isolate viral  
supernatant  
Catalog Ready-to-Package Library  
Custom Ready-to-Clone Library  
Custom Ready-to-Amplify Library  
Figure 1. Agilent offers CRISPR libraries in a variety of formats, from plasmid libraries to unamplified oligo pools.  
GeCKO Libraries  
Guide Representation Comparison with Competitor Libraries  
Species  
Human  
19,050  
Mouse  
20,611  
Missed  
Guides  
90th/10th  
percentile percentile  
95th/5th  
99.5th/0.5th  
percentile  
Genes targeted  
Agilent option 1  
1
1
2.32  
2.47  
2.38  
1.99  
8.73  
5.29  
6.00  
3.04  
3.38  
6.72  
11.06  
9.83  
Targeting constructs per gene  
miRNA targeted  
6
6
Agilent option 2  
1,864  
1,175  
Agilent option 3  
1
3.19  
Targeting constructs  
per miRNA  
Agilent option 4  
1
2.64  
8.30  
4
4
GeCKO (Broad)  
?
16.00  
9.83  
NA  
Control (nontargeting) sgRNA  
Total sgRNA constructs  
Viral plasmid vector  
1,000  
1,000  
GeCKO (Competitor)  
GeCKO (Competitor) expanded  
39  
204  
68.40  
333.00  
123,411  
130,209  
11.95  
Single and dual vector.lentiCRISPRv2  
and lenitGuide-Puro  
Table 2. With <.01% missed guides, you can be sure the guides in your library  
will be present in your delivered library. The uniformity of our libraries has an  
average 90/10 ratio of 2.29, which is less than half that of our competitor’s  
libraries (5.29).  
Table 1. The GeCKOv2 library contains experimentally validated CRISPR  
guides targeting all human or mouse genes.  
Instructions to order GeCKOv2 Libraries  
GeCKOv2 libraries are available for both mouse (G7554A) and human (G7555A) applications. Table 1 provides a summary of  
the libraries including the number of guides per gene, non-coding targets, and control sequences. Kits also include a control  
appropriate for the organism the library is designed for. If you require additional information, including the sequences of each  
component of the library please contact your local Agilent representative or technical support.  
Ordering Information  
SureGuide GeCKOv2  
CRISPR Libraries  
SureGuide Amplified Custom  
CRISPR Libraries  
SureGuide Unamplified Custom  
CRISPR Libraries  
G7553A - Human  
G7554A - Mouse  
Part Numbers  
G7555A - Human (hU6 promoter)  
G7555B - Any species  
Library Format  
Delivery  
Ready-to-package plasmid library  
Lentivirus  
Ready-to-clone amplified DNA library  
Designed for lentivirus, user choice  
Up to 60,000  
Ready-to-amplify DNA library  
Users choice  
Number of Guides  
Human - 123,411; Mouse - 130,209  
Up to 100,000  
Amplification, cloning, viral packaging,  
delivery, screening  
User Supplies  
Sequence Verified  
Quantity  
Lentivirus packaging, delivery, screening  
Yes  
Cloning, viral packaging, delivery screening  
No  
No  
10 pmol of linear, unamplified, pooled  
library  
200 ug of plasmid DNA split into A and B libraries 125 ng of linear, amplified, pooled library  
Also Included  
Custom Design Input  
Control  
N/A  
N/A  
Amplification kit  
None  
Mal1-C  
Up to 50 nt sequence for each guide  
User designed  
Complete sequence up to 200 nt  
User designed  
www.agilent.com/genomics/CRISPR  
For Research Use Only. Not for use in diagnostic procedures.  
This information is subject to change without notice.  
PR7000-0245  
© Agilent Technologies, Inc. 2017  
Published in the USA, September, 2017  
5991-7347EN  

相关型号:

G7555B

SureGuide CRISPR Libraries
HP

G75XB

T-1-3/4 Double Height, Right-Angle LED Assembly
IDEA

G76-010-05H-AGGA-H

Interface Connectors for Cradle
MITSUMI

G760A

Fan Speed PWM Controller
ETC

G760AF

Switching Regulator, Voltage-mode, 0.35A, PDSO8, SOP-8
GMT

G761

Fan Speed Controller with Linear or PWM Mode
GMT

G762

Fan Speed Controller with Linear or PWM Mode
GMT

G763

Fan Speed Controller with Linear or PWM Mode
GMT

G764

Fan Speed Controller with Linear or PWM Mode
GMT

G766

Remote Temperature Sensor with SMBus Serial Interface
ETC

G767

Remote/Local Temperature Sensor with SMBus Serial Interface
GMT

G767F

Remote/Local Temperature Sensor with SMBus Serial Interface
GMT