600882 [HP]
Real-Time PCR System;型号: | 600882 |
厂家: | HEWLETT-PACKARD |
描述: | Real-Time PCR System PC |
文件: | 总2页 (文件大小:309K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AriaMx
Real-Time PCR System
SPEED
PRECISION
AGILITY
Specifications Table
Feature
Description
Excitation Source
Detection Sources
Optical Cartridges
8 dye specific LEDs per optical module
8 photodiodes
SYBR/FAM
HEX
ROX
CY3
CY5
ATTO425
6 slots, swappable optical modules
Dye Selection
Excitation and Emission
Reaction Volume
Chemistries Supported
Thermal System
10μL to 30μL
SYBR, Probe, HRM
Six Peltiers made from two ceramic plates with semi-conductor elements, 96-well
Thermal System
25.0 – 99.9°C
Heating: 6.0°C/sec
Temperature Range
Cooling: 3.0°C/sec (Median), 2.5°C/sec (Average)
Accuracy: 0.2°C or better atꢀtypical annealing, amplification, and denaturation temperatures
integrated quantitative PCR amplification,
detection, and data analysis system. Now
with innovative modular optics which can be
changed out in one easy step, the instrument
provides the flexibility to scale up over time,
as needed.
Dynamic Range
Experiment Types
9
Quantitative PCR with dye, Quantitative PCR with probe, Allele Discrimination with HRM,
Allele Discrimination with probe, Comparative Quantitation, User Defined
Uniformity
Data Acquisition Time
Cq Uniformity
Electrical Power (input)
Operating Environment
Weight
0.4°C
<3 seconds for all
Cq St Dev <0.20 at fast cycling (5s 95°C/10s 60°C)
100 – 240VAC, 50/60Hz, 1100VA
20 – 30°C, 20 – 80% non-condensing humidity, 7500 feet, max altitude
50 lbs. (23 kg)
The latest design combines a state-of-the-
art thermal cycler, an advanced optical
system with LED excitation source, and data
analysis software. Continuing the tradition of
intuitive software, the instrument now has a
touchscreen so plates and analytics can be
started with the touch of a finger.
Dimensions
Sample Containers
Warranty
19.7” W x 18.1“ D x 16.5” H (50cm x 46cm x 42cm)
96-well plates, strip tubes; 0.2mL tubes
• 1-year warranty is standard with the instrument
• 5-year warranty and service packages available
• Thermal, physical, interactive (sensors) tests
• Extended: 125 performance points tested in 30 minutes
• Start-up: 59 performance points tested in ~1 minute
• Optional bypass of both features
Onboard Analytics
Services (upon request) • Installation and familiarization
• Standard and Enhanced Preventative Maintenance
• Additional year warranty (+1 increments, up to 5 years coverage)
• Return-to-Agilent Instrument Exchange Program
• Thermal block verification
With enhanced performance, the software
provides results capturing RDML information
required for publishing under the miQE
guidelines. Simultaneously, the software is
equipped to export images and raw data
in multiple formats, allowing results to be
viewed in common programs.
Operating System
• Windows 7 and 10
MS Office Compatibility • Microsoft 2010 and 2013 compatible
Run Modes
• Stand alone
• PC connected
• LAN connected to PC (more than 20 instruments can be connected and monitored remotely)
• USB connected, external devices
For more firmware and software features, see next page.
|
AriaMx Real-Time PCR System
Specifications Table (con’t)
Feature
Description
Free software including LIMS connectivity
Software
Optical Module Calibration
and Cleaning
• All channels can be tested and calibrated
• All attributes of optical channels are calibrated at the factory – LED light output, light path, mirror, and photodiode
• Optical modules can be cleaned in lab without Agilent technician or sending back to factory
Selected Applications
• Quantitative and qualitative gene expression analysis
• miRNA analysis
• NGS library quantification
• 2-6 channel multiplex ability
• Genetic mapping
• HRM analysis (including genotyping, mutational
analysis, and class IV SNP detection)
• Pathogen quantification
• Genetic fingerprinting
Ordering Information
Category
Part #
Description
Quantity
1
Base Instrumentation
Optical Cartridges
(*Use part numbers to upgrade
post instrument purchase)
G8830A
AriaMx Real-Time PCR System
SYBR/FAM Optical Cartridge
ROX Optical Cartridge
Option 101 (G8830-67001*)
Option 102 (G8830-67002*)
Option 103 (G8830-67003*)
Option 104 (G8830-67004*)
Option 105 (G8830-67005*)
Option 106 (G8830-67006*)
1/pack
1/pack
1/pack
1/pack
1/pack
1/pack
HEX Optical Cartridge
CY3 Optical Cartridge
CY5 Optical Cartridge
ATTO425 Optical Cartridge
Software Upgrade and PC
Option 300
Option 400
Option 650
Electronic Tracking of HRM software
HRM analysis software upgrade
AriaMx PC Kit
1
1
1
(with instrument)
AriaMx Software Upgrade
G5380AA
G5381AA
401490
401491
401494
401492
401493
401425
401427
600880
Electronic Tracking of the HRM software
HRM analysis software upgrade only
AriaMx 96-well plates, skirted and low profile
AriaMx 96-well plates, skirted and rigid
AriaMx 96-well plates, non skirted low profile
AriaMx adhesive plate seals
AriaMx low profile strip tubes for PCR and qPCR applications, without caps
AriaMx Strip caps for PCR and qPCR applications
AriaMx Optical Strip Caps
Brilliant III Ultra-Fast qPCR Master Mix
Brilliant III SYBR Ultra-Fast qPCR Master Mix
AriaMx SYBR Qualification Plate
Brilliant Multiplex qPCR Master Mix
Brilliant HRM Ultra-Fast Loci Master Mix
AriaMx HRM Calibration Kit
1
1
(post instrument purchase)
Plastics
1 x 25/pack
1 x 25/pack
1 x 25/pack
1 x 25 plates
8/strip x 120/box
8/strip x 120/box
Box of 60
400 rxns
400 rxns
1 plate/pack
200 rxns
200 rxns
1 x 96-well plate
1
Reagents
PROBE
SYBR 600882
5190-7708
MULTIPLEX 600553
HRM
5190-7827
5190-7702
600906*
600907*
5190-9370
Starter Packs
AriaMx SYBR Green Starter Pack
AriaMx qRT-PCR Starter Pack
Brilliant HRM Ultra fast Starter Pack
(Includes cDNA synthesis kits*
and recommended plastics)
1
1
FOR MORE INFORMATION
Useful Tools and Web Links
qpcr@agilent.com | www.agilent.com/genomics/ariamx
qPCR Decision Tree
For Americas, call 800.227.9770 or for other regions,
consult www.agilent.com/genomics/contactus
Determine which qPCR reagents or enzymes best serve
your needs by visiting www.agilent.com/genomics/
qpcrdecisiontree
PR7000-0130
For Research Use Only. Not for use in diagnostic procedures.
© Agilent Technologies, Inc., 2017
Published in USA, July 8, 2016
Software Updates
Ensure your software is the most current version
by visiting
5991-5711EN
www.agilent.com/genomics/ariamxsoftware
For a virtual demo, visit
www.agilent.com/genomics/ariamxvideos
For a live demo, call your Agilent sales representative.
|
相关型号:
©2020 ICPDF网 联系我们和版权申明