HFD42/6-L13SR [HONGFA]

SUBMINIATURE SIGNAL RELAY;
HFD42/6-L13SR
型号: HFD42/6-L13SR
厂家: HONGFA TECHNOLOGY    HONGFA TECHNOLOGY
描述:

SUBMINIATURE SIGNAL RELAY

文件: 总5页 (文件大小:865K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SUBMINIATURE SIGNAL RELAY  
HFD42  
Features  
Offers excellent board space savings  
Surge withstand voltage up to 2500V,  
meets FCC Part 68 and Telecordia  
Meets EN60950/EN41003  
SMT and DIP types available  
High load capacity 2A  
File No.:E133481  
Low power consumption  
Single side stable and latching type available  
File No.:R50317623  
RoHS compliant  
CHARACTERISTICS  
CONTACT DATA  
2C  
Insulation resistance  
1000M (at 500VDC)  
1500VAC 1min  
750VAC 1min  
Contact arrangement  
Contact resistance  
Contact material  
Between coil & contacts  
100m max. (at 10mA 30mVDC)  
Dielectric  
strength  
AgNi + Au plated  
Between open contacts  
Between contact sets  
1A 30VDC  
0.5A 125VAC  
2A 30VDC  
1800VAC 1min  
Contact rating  
(Res. load)  
Surge withstand voltage  
Between open contacts (10/160µs)  
Between coil & contacts (2/10µs)  
1500V(FCC part 68)  
2500V (Telecordia)  
1A 125VAC  
Max. switching current  
Max. switching voltage  
Max. switching power  
Min. applicable load  
Mechanical endurance  
4A  
250VAC / 220VDC  
125VA / 120W  
10mV 10µA  
Operate time (Set time)  
Release time (Reset time)  
Ambient temperature  
Humidity  
3ms max.  
3ms max.  
-40 to 85  
1 x 108OPS  
5% to 85% RH  
10Hz to 55Hz 3.3mm DA  
10Hz to 55Hz 5.0mm DA  
735m/s2  
1 x 105OPS( 1A 30VDC,  
Resistive load, at 85oC, 1s on 9s off)  
1 x 105OPS( 0.5A 125VAC,  
Functional  
Destructive  
Functional  
Destructive  
Vibration  
resistance  
Electrical endurance  
Resistive load, at 85oC, 1s on 9s off)  
Shock  
resistance  
980m/s2  
Termination  
Unit weight  
DIP, SMT  
COIL  
Approx. 1.1g  
Single side stable: 140mW230mW  
1 coil latching: 100mW120mW  
Moisture sensitivity levels (Only for  
SMT type, JEDEC-STD-020)  
Construction  
Coil power  
MSL3  
Plastic sealed  
SAFETY APPROVAL RATINGS  
Notes: 1) The data shown above are initial values.  
1A 30VDC 85  
0.5A 125VAC 85  
2A 30VDC 85  
1A 125VAC 85  
0.5A 125VAC 85  
1A 30VDC 85  
2A 30VDC 85  
1A 125VAC 85  
UL/CUL  
TÜV  
Notes: 1) All values unspecified are at room temperature.  
2) Only typical loads are listed above. Other load specifications  
can be available upon request.  
HONGFA RELAY  
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED  
2019 Rev. 1.00  
95  
COIL DATA  
at 23  
Single side stable  
Pick-up  
Voltage  
VDC  
Drop-out  
Voltage  
VDC  
Coil  
Resistance  
Nominal  
Voltage  
VDC  
Max.  
Voltage  
VDC  
Coil  
Code  
max.  
min.  
HFD42/1.5  
1.5  
2.4  
3
1.13  
1.8  
0.15  
0.24  
0.3  
16 x (1 10%)  
41 x (1 10%)  
2.2  
3.6  
HFD42/2.4  
HFD42/3  
HFD42/4.5  
HFD42/5  
HFD42/6  
HFD42/9  
HFD42/12  
HFD42/24  
2.25  
3.38  
3.75  
4.5  
64.3 x (1 10%)  
145 x (1 10%)  
178 x (1 10%)  
257 x (1 10%)  
579 x (1 10%)  
1028 x (1 10%)  
2504 x (1 10%)  
4.5  
4.5  
5
0.45  
0.5  
6.7  
7.5  
6
0.6  
9.0  
9
6.75  
9
0.9  
13.5  
18.0  
36.0  
12  
24  
1.2  
18  
2.4  
Notes: 1) Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.  
1 coil latching  
Set  
Voltage  
VDC  
Reset  
Voltage  
VDC  
Coil  
Resistance  
Nominal  
Voltage  
VDC  
Max.  
Voltage  
VDC  
Coil  
Code  
max.  
max.  
1.5  
2.4  
3
1.13  
1.8  
1.13  
1.8  
22.5 x (1 10%)  
58 x (1 10%)  
3.0  
4.8  
HFD42/1.5-L  
HFD42/2.4-L  
HFD42/3-L  
HFD42/4.5-L  
HFD42/5-L  
HFD42/6-L  
HFD42/9-L  
HFD42/12-L  
HFD42/24-L  
2.25  
3.38  
3.75  
4.5  
2.25  
3.38  
3.75  
4.5  
90 x (1 10%)  
6.0  
4.5  
5
203 x (1 10%)  
250 x (1 10%)  
360 x (1 10%)  
810 x (1 10%)  
1440 x (1 10%)  
2880 x (1 10%)  
9.0  
10.0  
12.0  
18.0  
24.0  
36.0  
6
9
6.75  
9
6.75  
9
12  
24  
18  
18  
Notes: 1) When user's requirements can't be found in the above table,special order allowed.  
2) In case 5V of transistor drive circuit, it is recommended to use 4.5V type relay, and 3V to use 2.4V type relay.  
ORDERING INFORMATION  
S
(XXX)  
3
HFD42 / 24  
-L1  
R
Type  
Coil voltage  
Sort  
1.5, 2.4, 3, 4.5, 6, 9, 12, 24VDC  
L1: 1 coil latching  
Nil: Single side stable  
Contact material 3: AgNi+Gold plated  
Terminal type  
Packing style  
S: Standard SMT  
R: Tape and reel packing (Only for SMT type)1)  
S1: Short terminal SMT  
Nil: DIP  
Nil: Tube packing(Only for DIP type)  
Special code2)  
XXX: Customer special requirement  
Nil: Standard  
Notes: 1) R type (tape and reel) packing is moisture-proof which meets requirement of MSL-3. Please choose R type packing for SMT products.  
For R type, the letter "R" will only be printed on packing tag but not on relay cover. Tube packing is normally not available for SMT  
products unless specially requested by customer. But please note that tube packing is not moisture-proof so please bake the products  
before use according to description of Notice 10 herewith. In addition, tube packaging will be adopted when the ordering quantity of R  
type is equal to or less than 100 pieces unless otherwise specified.  
2) The customer special requirement express as special code after evaluating by Hongfa.  
96  
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT  
Unit: mm  
Outline Dimensions  
PCB Layout  
(Bottom view)  
10.6  
5.7  
2.2 2.2  
3.2  
DIP type  
8-Ø0.85  
1.5  
10.6  
5.7  
3.2  
2.2 2.2  
Standard  
SMT type  
0.8  
1.5  
7.4  
5.7  
10.6  
3.2  
2.2 2.2  
Short terminal  
SMT type  
0.8  
5.7  
1.5  
Wiring Diagram  
(Bottom view)  
Single side stable  
1 coil latching  
1
2
3
4
1
2
3
4
5
8
7
6
5
8
7
6
Orientation mark  
Orientation mark  
No energized condition  
Reset condition  
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be ±0.2mm; outline dimension 1mm  
and 5mm, tolerance should be ±0.3mm; outline dimension 5mm, tolerance should be ±0.4mm.  
2) The tolerance without indicating for PCB layout is always ±0.1mm.  
3) The width of the gridding is 2.5mm.  
97  
TAPE PACKING  
Unit: mm  
Direction of Relay Insertion  
I
Reel  
4:1  
Orientation mark  
Cover tape  
Feed direction  
Embossed  
carrier tape  
Notes: 1) Packing: 500pcs/reel, 4 reels/carton.  
2) MOQ for reel packing is 500pcs.  
I
adhesive tape  
Cover tape  
adhesive tape  
Cover tape  
Feed direction  
during customer usage  
at least 5 empty  
relay positions  
at least 5 empty  
relay positions  
Reel Dimensions  
1
29.4  
24.4  
0.2  
13  
0.3  
1.6  
2
3-R1  
21  
0.5  
Tape Dimensions  
4
A-A  
B-B  
1.5  
2
0.05  
B
0.5  
3
A
A
2
0.2  
7.7  
12  
10.1  
B
98  
TAPE PACKING  
Unit: mm  
Tape Dimensions (S1 type: Short terminal SMT)  
4
A-A  
B-B  
1.5  
2
B
0.05  
0.5  
3
A
A
2
0.2  
6
12  
B
10.1  
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be ±0.2mm; outline dimension 1mm  
and 5mm, tolerance should be ±0.3mm; outline dimension 5mm, tolerance should be ±0.4mm.  
2) The tolerance without indicating for PCB layout is always ±0.1mm.  
3) The width of the gridding is 2.54mm.  
CHARACTERISTIC CURVES  
REFLOW WELDING,TEMPERATURE  
MAXIMUM SWITCHING POWER  
ENDURANCE CURVE  
ON PCB BOARD  
RECOMMENDED WELDING TEMPERATURE  
1000V  
Temperature  
(
)
500  
AC Resistive Load  
125V  
30VDC  
Resistive Load  
Soldering  
100V  
max.245  
220  
100  
50  
max. 3 /s  
DC Resistive Load  
30V  
180  
150  
Preheating  
max. 6 /s  
10V  
10  
125VAC Resistive Load  
Time(s)  
max. 60  
max. 100  
10mV  
1
max. 100  
100mA  
1A  
10A  
10uA  
0
1
2
3
max. 280  
Contact Current  
Contact Current (A)  
Test conditions:  
Resistive load, at 40oC, 1s on 9s off.  
Notice  
1) This relay is highly sensitive polarized relay, if correct polarity is not applied to the coil terminals, the relay does not operate properly.  
2) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage.  
3) Relay is on the “reset” status when being released from stock, with the consideration of shock risen from transit and relay mounting, it should  
be changed to the “set” status when application(connecting to the power supply). Please reset the relay to “set” or “reset” status on request.  
4) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached the  
rated voltage. Regarding latching relay, in order to maintain the "set" or "reset" status, impulse width of the rated voltage applied to coil should  
be more than 5 times of "set" or "reset" time.  
5) The relay may be damaged because of falling or when shocking conditions exceed the requirement.  
6) For SMT products, validation with real application should be done before your series production, if the reflow-soldering temperature curve is out  
of our recommendation. Generally, two-time reflow-soldering is not recommended for the relay. However, if two-time reflow-soldering is required,  
a 60-min. interval should be guaranteed and a validation should be done before production.  
7) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.  
8) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 40oC after welding, then clean it and deal with coating, remarkably  
the temperature of solvents should also be controlled below 40oC.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like  
gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment.  
9) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay".  
10) Relays packaged in moisture barrier bags meet MSL-3 requirements. The relays should be stored at ambient conditions of 30and 60%  
RH after they are removed from their packaging, and should be used within 168 hours. If the relays cannot be used within 168 hours, please  
repack them or store them in a drying oven at 25℃±5, 10% RH. Otherwise, relays may be subjected to a soldering test to check their  
performance, or they may be used after keeping them in an oven for 72 hours at with 50℃±5, 30% RH.  
Disclaimer  
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to  
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s  
responsibility to determine which product should be used only.  
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.  
99  

相关型号:

HFD42/9-L13S1R

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD42/9-L13SR

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD43

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/1.5-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/12-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/2.4-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/24-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/3-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/4.5-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/5-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/6-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA

HFD43/9-LSR

1GHz SUBMINIATURE HIGH-FREQUENCY RELAY
HONGFA