HF161F-W/12-HT [HONGFA]

SOLAR RELAY;
HF161F-W/12-HT
型号: HF161F-W/12-HT
厂家: HONGFA TECHNOLOGY    HONGFA TECHNOLOGY
描述:

SOLAR RELAY

文件: 总3页 (文件大小:590K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HF161F-W  
SOLAR RELAY  
Features  
31A switching capacity  
Applicable to inverter used for photovoltaic power  
generation systems  
File No.:E134517  
Ideal for UPS  
1.5mm contact gap (compliant to European Photovoltaic  
Standard VDE0126)  
V
D E  
1.8mm contact gap (compliant to IEC 62109-2-2011)  
The clearance distance between contact and coil is bigger  
than 6.4mm, the creepage distance is bigger than 8mm.  
(special code 477:7.5mm)  
File No.:40031410  
Low coil holding voltage contributes to saving energy of  
equipment.  
File No.:CQC10002050943  
CQC18002203499  
UL insulation system: Class F  
RoHS compliant  
CONTACT DATA  
CHARACTERISTICS  
Insulation resistance  
1.8mm  
1A  
2.0mm  
1000M (at 500VDC)  
4500VAC 1min  
2500VAC 1min  
10kV (1.2/50µs)  
20ms max.  
Contact gap  
1.5mm  
2.3mm  
Between coil & contacts  
Contact arrangement  
Dielectric  
strength  
1)  
Between open contacts  
Contact resistance  
100m (1A 6VDC)  
Surge voltage (between coil & contacts)  
Operate time (at rated. volt.)  
Release time (at rated. volt.)  
Contact material  
Contact rating  
AgSnO2  
Resistive:  
Resistive:  
Resistive:  
26A 250VAC  
Inductive:  
31A 250VAC  
(cosø=0.8)  
0.1s:10s  
26A 250VAC  
26A 250VAC  
10ms max.  
Resistive:  
26A 250VAC  
Inductive:  
Inductive:  
33A 250VAC  
31A 250VAC  
95K max. (Contact load current 31A,  
rated voltage excitation, at 60oC)  
(cosø=0.8)  
(cosø=0.8)  
Temperature rise  
(at rated. volt.)  
0.1s:10s  
0.1s:10s  
Max. switching voltage  
Max. switching current  
277VAC  
70K max. (Contact load current 31A,  
80% of rated voltage excitation, at 85oC)  
33A  
31A  
26A  
31A  
196m/s2  
980m/s2  
Functional  
Destructive  
Shock  
resistance  
Max. switching power  
Mechanical endurance  
7750VA 8250VA  
7750VA  
7202VA  
6
5
1 x 10 OPS 1 x 105OPS  
5
1 x 10 OPS 1 x 10 OPS  
10Hz to 55Hz 1.5mm DA  
Vibration resistance  
HT type:  
HT type:  
HT type:  
3 x 104OPS  
(26A 250VAC  
Resistive  
HT type:  
3 x 104OPS  
(26A 250VAC  
Resistive  
Room temp.  
1.5s on 1.5s off)  
3 x 104OPS  
3 x 104OPS  
-40oC to 85oC  
(Apply holding voltage to coil, which  
is 45% to 80% that of rated voltage)  
(26A 250VAC (26A 250VAC  
Electrical endurance  
Resistive  
75  
Resistive  
75  
Ambient temperature  
75  
1.5s on 1.5s off) 1.5s on 1.5s off)  
1.5s on 1.5s off)  
Notes: 1)The data shown above are initial values.  
Humidity  
5% to 85% RH  
PCB  
Termination  
Unit weight  
Construction  
COIL  
Approx. 21g  
Flux proofed  
Coil power  
Approx. 1.4W  
35% to 120%UN (at 23  
45% to 80%UN (at 85  
)
)
Holding voltage  
Notes: The data shown above are initial values.  
Notes: 1)The coil holding voltage is the voltage of coil after being applied  
rated voltage for 100ms  
SAFETY APPROVAL RATINGS  
2)The relay col does not allow applied more than maximum of  
holding voltage values for a long time (Eg: 120% Un at 23  
80% Un at 85 ) , prevent overheating burned.  
;
26A 277VAC at 75  
AgSnO2  
UL/CUL  
at 23  
COIL DATA  
22A 277VAC at 85  
Pick-up Drop-out  
Voltage Voltage  
Max.  
Voltage  
VDC *  
Nominal  
Voltage  
VDC  
Coil  
Resistance  
26A 277VAC at 75  
22A 277VAC at 85  
31A 250VAC cosØ =0.8 0.1s:10s  
33A 250VAC cosØ =0.8 0.1s:10s (477)  
2)  
VDC  
VDC  
min.  
VDE  
AgSnO2  
1)  
1)  
max.  
9
12  
18  
24  
6.3  
0.9  
10.8  
14.4  
21.6  
28.8  
58 x (1 10%)  
103 x (1 10%)  
230 x (1 10%)  
410 x (1 10%)  
Notes: 1) All values unspecified are at room temperature.  
2) Only typical loads are listed above. Other load specifications  
can be available upon request.  
8.4  
1.2  
1.8  
2.4  
12.6  
16.8  
Notes:1)The data shown above are initial values.  
2)*Maximum voltage refers to the maximum voltage which relay  
coil could endure in a short period of time.  
HONGFA RELAY  
ISO9001ISO/TS16949ISO14001OHSAS18001IECQ QC 080000 CERTIFIED  
2019 Rev. 1.00  
285  
ORDERING INFORMATION  
T
HF161F-W /  
12  
-H  
(XXX)  
Type  
Coil voltage  
9, 12, 18, 24VDC  
H: 1 Form A  
T: AgSnO2  
Contact arrangement  
Contact matcrial  
Special code3)  
XXX: Customer special requirement  
Nil: Standard  
Notes: 1) Water cleaning or surface process is not suggested after the flux-proofed relays are assembled on PCB.  
2) Flux-proofed relays can not be used in the environment with pollutants like H2S, SO2, NO2, dust, etc.  
3) The customer special requirement express as special code after evaluating by Hongfa. e.g. (414) stands for product with coil  
terminal of 1.4X0.4; e.g. (477) stands for Contact gap: 1.8mm.(456) stands for Contact gap: 2.0mm.(704)stands for Contact gap: 2.3mm.  
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT  
Unit: mm  
Outline Dimensions  
Standard type  
30.4±0.3  
15.9 ±0.3  
+0.2  
-0.05  
2- (0.8 ±0.3 )x(1.5 ±0.3  
)
2xØ 0.7  
(414) special code version  
30.4±0.3  
15.9±0.3  
2-(0.8±0.3 )x(1.5 ±0.3  
)
+0.2  
-0.05  
+0.2  
x
0.4-0.05  
2-1.4  
286  
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT  
Unit: mm  
PCB Layout(Bottom view)  
Standard type  
(414) special code version  
27.6±0.1  
12 ±0.05  
22 ±0.1  
Wiring Diagram  
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be ±0.2mm; outline dimension 1mm  
and 5mm, tolerance should be ±0.3mm; outline dimension 5mm, tolerance should be ±0.4mm.  
2) The tolerance without indicating for PCB layout is always ±0.1mm.  
CHARACTERISTIC CURVES  
ENDURANCE CURVE  
MAXIMUM SWITCHING POWER  
500  
100  
50  
AC Resistive Load  
100  
50  
10  
5
250VAC  
Resistive Load  
1
0.5  
10  
0.1  
0
2
4
6
8
10 12 14 16 18 20 22 24 26  
1
10  
20 30  
100 200 300  
1000  
Contact Current (A)  
Contact Voltage (V)  
Test conditions:  
at 75 , 1.5s on 1.5s off.  
Disclaimer  
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to  
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s  
responsibility to determine which product should be used only.  
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.  
287  

相关型号:

HF161F-W/18-HT

SOLAR RELAY
HONGFA

HF161F-W/24-HT

SOLAR RELAY
HONGFA

HF161F-W/9-HT

SOLAR RELAY
HONGFA

HF161F-W_V01

SOLAR RELAY
HONGFA

HF161F/12-HT

MINIATURE HIGH POWER RELAY
HONGFA

HF161F/24-HT

MINIATURE HIGH POWER RELAY
HONGFA

HF161F/48-HT

MINIATURE HIGH POWER RELAY
HONGFA

HF161F/5-HT

MINIATURE HIGH POWER RELAY
HONGFA

HF162F

SUBMINIATURE INTERMEDIATE POWER RELAY
HONGFA

HF162F-E12-H

SUBMINIATURE INTERMEDIATE POWER RELAY
HONGFA

HF162F-E18-H

SUBMINIATURE INTERMEDIATE POWER RELAY
HONGFA

HF162F-E24-H

SUBMINIATURE INTERMEDIATE POWER RELAY
HONGFA