HIH-4602-A/C Series
Humidity Sensors
DESCRIPTION
The HIH-4602-A contains an integral thermistor, while the HIH-
4602-C contains an integral precision RTD.
HIH-4602-A/C Series Relative Humidity (RH) sensors combine
both relative humidity and temperature sensing in a TO-5
housing with a hydrophobic sintered stainless steel filter.
Factory calibration data supplied with each sensor allows
individually matched downstream electronics and ±±.5 %RH
total accuracy.
The laser-trimmed, thermoset polymer capacitive sensing
elements have on-chip integrated signal conditioning.
The temperature sensor is thermally connected with the RH
sensor making the HIH-4602-A/C often ideal for measuring
dew point and other absolute moisture terms.
FEATURES
POTENTIAL APPLICATIONS
•
•
•
•
•
•
•
Near linear voltage output vs %RH
Laser-trimmed interchangeability
Enhanced accuracy, fast response
Chemically resistant
Stable, low drift performance
Built-in static protection
•
•
•
•
•
Refrigeration
Drying
Meteorology
Battery-powered systems
OEM (Original Equipment Manufacturer) assemblies
Often ideal for dew point and absolute moisture
measurements
•
TO-5 housing
HIH-4602-A/C Series
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter
Minimum
Typical
Maximum
Unit
Specific
Note
–
Interchangeability (first order curve)
0% RH to 59% RH
60% RH to 100% RH
Accuracy (best fit straight line)
Hysterisis
Repeatability
Settling time
Response time (1/e in slow moving air)
Stability (at 50% RH in one year)
Voltage supply
–
-5
-8
-3.5
–
–
–
–
5
8
+3.5
–
–
% RH
% RH
% RH
% RH
% RH
ms
–
–
–
–
1
±
±0.5
–
–
–
–
–
–
70
–
–
–
50
±1.2
–
s
–
–
–
% RH
Vdc
µA
–
4
–
5.8
500
–
–
Current supply
Output voltage temp. coefficient at 50% RH, 5 V
Voltage output (1st order curve fit)
200
-4
–
–
mV/ºC
–
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC
True RH = (sensor RH)/(1.0546-0.00216T), T in ºC
Temperature compensation
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Specific Notes:
1. Device is calibrated at 5 Vdc and 25 ºC.
2. Non-condensing environment.
-40[-40]
0
-50[-58]
See Figure 1.
See Figure 1.
–
85[185]
100
125[257]
ºC[ºF]
% RH
ºC[ºF]
% RH
–
2
–
2
See Figure 2.
General Notes:
•
•
Sensor is ratiometric to supply voltage.
Extended exposure to >90% RH causes a reversible shift of
±% RH.
•
Sensor is light sensitive. For best performance, shield sensor
from bright light.
FACTORY CALIBRATION DATA
HIH-4602 Sensors are supplied with a calibration and data
printout. See Table 2.
TABLE 3. HIH-4602-A NTC THERMISTOR TEMPERATURE
SPECIFICTIONS
Rb = 100 kOhm ±5% at 25 ºC
TABLE 2. EXAMPLE DATA PRINTOUT
Beta = 4250, 25 ºC to 85 ºC
Model
Channel
Wafer
MRP
HIH-4602-C
92
0±0996M
±±7±1±
1/T = a + b(Ln R) + c(Ln R) ^ ±, T in degrees K
Temp. ºC
Resistance
±51000
±±590
Low
0
Mid
50
100
Calculated values at 5 V
High
5569
VOUT at 0% RH
0.826 V
±.198 V
a = 0.00082808±
b = 0.000208691
c = 8.0812E-08
VOUT at 75.±% RH
Linear output for ±.5% RH
accuracy at 25 °C
Zero offset
Slope
0.826 V
±1.48± mV/%RH
(VOUT - zero offset)/slope
(VOUT - 0.826)/0.0±15
TABLE 4. HIH-4602-C RTD TEMPERATURE SENSOR
SPECIFICATIONS
RH
Thin film platinum RTD – Class 2B (Ro: ±0.25%)
DIN EN 60571 (PER IEC 751)
TCR = ±750 ppm/ºC
Ratiometric response for
0% RH to 100% RH
VOUT
VSUPPLY (0.1652 to 0.7952)
1000 Ohm at 0 ºC [±2 ºF]
2
www.honeywell.com/sensing
Humidity Sensors
FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.)
FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment.)
Honeywell Sensing and Control
±
HIH-4602-A/C Series
FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.)
4
3.5
3
2.5
2
Sensor Response
Sensor Response
Best Linear Fit
1.5
1
0.5
0
20
40
60
80
100
Relative Humidity (%RH)
FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.)
4.5
4
3.5
3
2.5
2
0 C
70 C
1.5
1
0.5
0
0
10
20
30
40
50
60
70
80
90
100
Relative Humidity (%)
4
www.honeywell.com/sensing
Humidity Sensors
FIGURE 5. HIH-4602-A/C 1MOUNTING DIMENSIONS (For reference only. mm/[in])
1. Case ground
2. Vdc out
±. (-) Power or ground
4. (+) Vdc supply
5., 6. HIH-4602-A thermistor for temperature compensation
5., 6. HIH-4602-C RTD for temperature compensation
FIGURE 6. RH SENSOR CONSTRUCTION
Sensor construction consists of a planar capacitor with a second polymer layer to protect against dirt, dust, oils and other hazards.
Honeywell Sensing and Control
5
HIH-4602-A/C Series
FIGURE 7. TYPICAL APPLICATION CIRCUIT
ORDER GUIDE
Catalog Listing
HIH-4602-A
Description
Monolithic IC humidity sensor with integral thermistor in TO-5 can
Monolithic IC humidity sensor with integral precision RTD in TO-5 can
HIH-4602-C
FURTHER HUMIDITY SENSOR INFORMATION
See the following associated literature at www.honeywell.com/sensing:
• Product installation instructions
• Application sheets:
–
–
–
–
Humidity Sensor Performance Characteristics
Humidity Sensor Theory and Behavior
Humidity Sensor Moisture and Psychrometrics
Thermoset Polymer-based Capacitive Sensors
6
www.honeywell.com/sensing
Humidity Sensors
THIS PAGE INTENTIONALLY LEFT BLANK..
Honeywell Sensing and Control
7
WARNING
MISUSE OF DOCUMENTATION
WARNING
PERSONAL INJURY
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
•
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6±55-2828
+65 6445-±0±± Fax
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
+1-±05-805-8188
+1-±05-88±-8257 Fax
+1-800-5±7-6945
Europe
Latin America
USA/Canada
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
+1-815-2±5-6847
+1-815-2±5-6545 Fax
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
009022-1-EN IL50 GLO Printed in USA
January 2007
© 2007 Honeywell International Inc. All rights reserved.
Minneapolis, MN 55422
www.honeywell.com/sensing
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00247/img/page/HIH-4602-L_1497959_files/HIH-4602-L_1497959_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00247/img/page/HIH-4602-L_1497959_files/HIH-4602-L_1497959_2.jpg)
HIH-4602-L-CP
HIH-4602 Series monolithic IC humidity sensor in TO-5 can, calibration and data printout
HONEYWELL
![](http://pdffile.icpdf.com/pdf1/p00135/img/page/HIH10_747006_files/HIH10_747006_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00135/img/page/HIH10_747006_files/HIH10_747006_2.jpg)
HIH100
AUTO-RANGING INPUT AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES
HITRON
![](http://pdffile.icpdf.com/pdf1/p00135/img/page/HIH10_747006_files/HIH10_747006_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00135/img/page/HIH10_747006_files/HIH10_747006_2.jpg)
HIH100-10
AUTO-RANGING INPUT AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES
HITRON
©2020 ICPDF网 联系我们和版权申明