BZV6-2RN2 [HONEYWELL]

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 10.34mm, Screw Terminal, Steel Roller Lever Plunger Actuator, Panel Mount-threaded,;
BZV6-2RN2
型号: BZV6-2RN2
厂家: Honeywell    Honeywell
描述:

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 10.34mm, Screw Terminal, Steel Roller Lever Plunger Actuator, Panel Mount-threaded,

开关 光电二极管
文件: 总26页 (文件大小:2817K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MICRO SWITCH™  
Medium-Duty Limit Switches  
E6/V6 Series  
Datasheet  
MICRO SWITCH™ E6/V6 Series  
Medium-Duty Limit Switches  
Honeywell MICRO SWITCH™ E6/V6 Series medium-duty limit switches are designed for a wide variety of indoor and  
outdoor applications. Typical applications include equipment for commercial, industrial, transportation, and agriculture  
industries. The electrostatic applied epoxy coating to the zinc housings enhance the durability of the product in most  
environments. The E6/V6 family of switches incorporates the Honeywell MICRO SWITCH™ BZ switch element which  
has the reliable snap-spring mechanism with more than 60 years of proven service.  
The sealed (actuators with boots) E6/V6 Series switches are preferred for applications where there could be  
exposure to liquid and/or particulate environments. The general purpose (actuators without boot seals) E6/V6 Series  
switches are ideal for applications where there will not be exposure to liquid or dust environments.  
The compact size of these limit switches permits installation where there is limited space available on equipment.  
Most SPDT (Single Pole Double Throw) E6/V6 catalog listings are certified to UL, CSA, and CE while the DPDT  
(Double Pole Double Throw) E6/V6 catalog listings are certified to UL and CSA.  
What makes our switches better?  
Designed with MICRO SWITCH™ BZ, BM, or DT basic switches  
to deliver precise switching of electrical and mechanical operating  
characteristics  
High capacity (22 A) available with BME6 Series switch  
Small footprint with easy access to wiring terminals  
Available in a configuration suited to the application with variety of  
actuators, circuitries, connectivities, and mounting options  
HIGH PERFORMANCE • DURABILITY  
CUSTOMIZATION • EASY TO INSTALL  
sensing.honeywell.com  
2
DESIGNED FOR DEMANDING ENVIRONMENTS AND  
APPLICATIONS  
Features  
and Benefits  
MICRO SWITCH™ E6/V6 Series switches feature an electrostatic epoxy coated  
zinc housing for durability in most indoor and outdoor environments, and a wide  
variety of actuators to solve most application requirements.  
Side and flange mounting options  
RELIABLY HANDLES ELECTRICAL LOADS  
The E6/V6 Series are available with SPDT contacts with momentary or maintained  
action, or DPDT contacts with momentary action. These switches also offer gold-  
plated switch contacts for logic-level circuits and silver alloy contacts for power  
duty circuits. The internal ground screw is provided to meet electrical codes as  
required.  
DESIGN FLEXIBILITY  
These limit switches are offered with multiple connectivity options: three different  
conduit offerings, four-pin “mini” style connector, pre-wired 16-gage four-  
conductor cable, pigtail with three-pin Deutsch connector.  
GLOBAL APPROVALS  
E6/V6 Series switches are UL, CSA, and CE certified for most SPDT catalog  
listings. The DPDT catalog listings are UL and CSA certified.  
LOW TEMPERATURE OPTIONS  
The E6/V6 Series’ standard temperature range is -32 °C to 71 °C [-25 °F to  
160 °F] with an optional -40 °C [-40 °F] low temperature.  
sensing.honeywell.com  
3
Figure 1. MICRO SWITCH™ E6 Side Mount and V6 Flange Mount with Features and Options  
Stainless steel roller  
Wide choice of actuators and  
operating characteristics  
Diaphragm boot seal  
for long life  
Single or double pole switches  
Rugged zinc housing and cover are phosphate treated and  
epoxy coated for environmental durability  
Multiple conduit options  
for ease of  
connectivity  
Popular 25,4 mm [1 in] mounting pattern  
Terminal screws of switch easily  
accessed with cover removed  
Captive cover screws (2)  
Internal ground screw provided in cover  
Cover with one-piece molded insulator seal  
Figure 1A. E6 Side mount with boot sealed actuator (typical)  
Wide choice of actuator styles and  
operating characteristics  
Hardened steel plunger for long life  
Single or double pole switches  
Rugged zinc housing and cover phosphate  
treated and electrostatic epoxy coated  
for environmental durability  
Multiple conduit options  
for ease  
of connectivity  
Terminal screws of switch easily  
accessed with cover removed  
Captive cover screws (2)  
Internal ground screw provided in cover  
Optional ꢀange base mounting  
Cover with one-piece molded insulator seal  
Figure 1B. V6 Flange mount without boot sealed actuator (typical)  
sensing.honeywell.com  
4
Potential Applications  
INDUSTRIAL  
Packaging equipment (balers, door interlocks)  
• Air curtains (control of air movement)  
• Conveyors (diverters, gates)  
TRANSPORTATION  
• Construction machinery and equipment (door and panel interlocks)  
Rail maintenance equipment (door and panel interlocks, position sensing)  
• Agricultural equipment (grain handling)  
Table 1. Specifications  
Characteristic  
Parameter  
top pin plunger (with and without boot seal)  
top roller plunger, parallel with long axis of switch (with and without boot seal)  
cross roller plunger, perpendicular with long axis of switch (with and without boot seal)  
manually operated (with boot seal)  
Actuators  
roller arm, adjustable (with and without boot seal)  
one-way roller lever (with boot seal)  
low-force rod lever (with and without boot seal)  
wobble (with boot seal)  
manual reset switches: top pin plunger, top roller plunger, adjustable roller arm, wobble  
Housing material  
Termination  
electrostatic epoxy coated zinc die-cast  
see table 2 below  
actuator with boot seal: NEMA 1, 3, 4, IP66  
actuator without seal boot: NEMA 1, IP40  
Sealing  
SPDT (snap-action contacts, 1NO/1NC)  
SPDT-DB (double break snap-action contacts, 1NO/1NC)  
DPDT (snap-action contacts, 2NO/2NC)  
Switching options  
Mechanical endurance  
Electrical endurance  
up to five million cycles for BZx6 and BMx6 switches; up to two million cycles for DTx6 switches  
up to 50K cycles at full rated load  
-32 °C to 71 °C [-25 °F to 160 °F] (standard)  
-40 °C to 71 °C [-40 °F to 160 °F] (optional low temperature)  
Operating temperature  
Agency approvals  
UL, CSA, CE  
Table 2. Terminations  
Catalog Listing Suffixes  
Description  
none  
S
0.5 - 14 NPT conduit thread  
0.5 - 14 NPSM conduit thread  
M20 - 1,5 mm conduit thread  
four-pin “mini” style connector  
M
R
F1  
F3  
305 mm [12 in] pigtail STOW-A, three conductor, 16-gage cable with three-pin Deutsch connector  
914 mm [36 in] 16-gage, four-conductor STO, PVC jacketed cable  
sensing.honeywell.com  
5
E6/V6 Series  
Table 3. Electrical Ratings  
Rating Code  
UL, CSA Rating  
CE Rating  
15 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;  
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;  
EN60947-5-1, IEC60947-5-1  
AC15, B300  
A
B
C
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc  
10 A @ 125 Vac, 250 Vac  
0.3 A @ 125 Vdc, 0.15 A @ 250 Vdc  
15 A @125 Vac, 250 Vac or 480 Vac;  
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;  
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc  
EN60947-5-1, IEC60947-5-1  
AC15, B300  
8 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;  
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;  
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc  
EN60947-5-1, IEC60947-5-1  
AC15, B300  
D
E
F
10 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;  
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;  
EN60947-5-1, IEC60947-5-1  
AC15, B300  
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc  
15 A @125 Vac, 250 Vac or 480 Vac;  
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;  
1.0 A @ 125 Vdc, 0.5 A @ 250 Vdc  
EN60947-5-1, IEC60947-5-1  
AC15, B300  
22 A @125 Vac, 250 Vac or 480 Vac;  
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;  
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc  
G
H
IEC 61058-1  
1A, 250 Vac  
1A @ 125 Vac (Gold-plated contacts)  
Table 4. CE Electrical Rating, EN60947-5-1, IEC 60947-5-1  
Designation &  
Continuous  
Current (A)  
Vac  
Amps Make  
Amps Break  
VA Rating Make  
VA Rating Break  
Category  
AC15, B300  
AC15, B300  
120  
240  
30  
15  
3.0  
1.5  
5
5
3600  
3600  
360  
360  
Table 5. Switching  
SPDT  
DPDT  
SPDT-DB  
NC  
NO  
C
NC  
NO  
NC  
NO  
NC  
NO  
C
NC  
NO  
C
sensing.honeywell.com  
6
MICRO SWITCH™ Medium-Duty Limit Switches  
PRODUCT NOMENCLATURE  
BZ  
E6  
2
R
N
Additional  
Modifications  
Actuator  
Internal Basic  
Switch Construction  
Enclosure  
Type  
Plunger  
Type  
Modifications3  
Switch Type  
Contact  
BZ Series  
Basic Switch  
SPDT, 15 A  
For use with “X” actuator,  
0.5-14 NPT  
Standard  
(Single-break)  
Pin plunger  
maintained contact2  
R
N
Q
conduit thread  
Side mount  
Seal boot  
E6  
V6  
(blank)  
(blank)  
(blank)  
Pre-leaded, 3 ft  
cable, conduit  
area epoxy sealed  
Maintained  
Double-break  
(BZ basic switch only)  
Flange mount  
Standard  
No seal boot  
contact with  
C3  
2
A
X
reset plunger2  
12-inch pigtail  
DT Series  
Basic Switch  
DPDT, 10 A  
Adjustable  
Special2  
cable with 3-pin  
Deutsch connect.  
7
2
F1  
F3  
roller lever  
Epoxy sealed,  
3 ft of cable  
Manual, palm  
button  
NOTE:  
4
1. Not all combinations of model codes are available.  
Contact your Honeywell rep or distributor for assistance.  
2. BZ Series only.  
3. More than one actuator modification may be permissible.  
For example, BZE6-2RN8034 is a roller plunger with low temperature seals.  
Epoxy sealed,  
5 ft of cable  
BM Series  
Basic Switch  
SPDT, 22 A  
#8 mounting  
screws  
7
F5  
F6  
Epoxy sealed,  
6 ft of cable  
8
Roller plunger  
80  
Epoxy sealed,  
4-pin “mini style”  
connector  
Coil spring  
wobble stick  
FR  
R
18  
One-way  
roller lever  
4-pin “mini style”  
connector  
28  
1/4-14 NPSM  
conduit threads  
Low temp.  
34  
S
M20 x 1,5 mm  
conduit thread  
Rod  
lever  
M
62  
72 Gold-contact  
switch  
722  
Cross  
roller plunger  
81  
sensing.honeywell.com  
7
E6/V6 Series  
Table 6. Order Guide • E6 Series Switches, Side Mount with Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
A,  
2,50 to 6,67 43,66 0,76  
[9 to 24] [1.719 0.030] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZE6-2RN  
12 in. pigtail, 3  
wire STO cable w/  
Deutsch connector  
BZ, E,  
SPDT 10 A  
2,50 to 6,67 43,66 0,76  
[9 to 24] [1.719 0.030] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZE6-2RN-F1  
Epoxy sealed with  
36 in. 4 wire STO  
cable  
BZ,  
SPDT 10 A  
E,  
2,50 to 6,67 43,66 0,76  
[9 to 24] [1.719 0.030] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZE6-2RN-F3  
BZ, A,  
SPDT 15 A  
2,50 to 6,67 43,66 0,76  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
M20-1,5 conduit  
thread  
BZE6-2RN-M  
BZE6-2RN-R  
BZE6-2RN-S  
BZE6-2RN7  
BZE6-2RN34  
BZE6-2RN72  
[9 to 24] [1.719 0.030] [0.078]  
2,50 to 6,67 43,66 0,76 1,98  
[9 to 24] [1.719 0.030] [0.078]  
2,50 to 6,67 43,66 0,76 1,98  
[9 to 24] [1.719 0.030] [0.078]  
2,50 to 6,67 43,66 0,76 1,98  
[9 to 24] [1.719 0.030] [0.078]  
2,50 to 6,67 43,66 0,76 1,98  
[9 to 24] [1.719 0.030] [0.078]  
2,50 to 6,67 43,66 0,76 1,98  
[9 to 24] [1.719 0.030] [0.078]  
BZ,  
SPDT  
D,  
8 A  
5,56  
[0.219]  
0,05  
[0.002]  
4-pin "mini" style  
connector  
BZ,  
A,  
5,56  
[0.219]  
0,05  
[0.002]  
0.5-14 NPSM  
conduit thread  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
5,56  
[0.219]  
0,05  
[0.002]  
#8 mounting screws  
Pin Plunger  
5,56  
[0.219]  
0,05  
[0.002]  
Low temperature  
-40 °C [-40 °F]  
BZ,  
SPDT  
H,  
1 A  
5,56  
[0.219]  
0,05  
[0.002]  
Gold-plated  
contacts  
BZ,  
SPDT,  
Double 15 A  
break  
F,  
2,50 to 6,67 43,66 0,76  
[9 to 24] [1.719 0.030] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
Recommended for  
dc applications  
BZE6-2AN  
BM,  
SPDT 22 A  
DT, B,  
DPDT 10 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
DT, B,  
DPDT 10 A  
G,  
2,50 to 6,67 43,66 0,76  
[9 to 24] [1.719 0.030] [0.078]  
7,23 to 16,4 46,02 0,76 2,80  
[26 to 59] [1.812 0.030] [0.110]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
Higher current ac  
applications  
BME6-2RN  
DTE6-2RN  
3,17  
[0.125]  
1,52  
[0.060]  
Double pole  
applications  
2,50 to 6,67  
[9 to24]  
56,7 1,14  
[2.232 0.045] [0.078]  
56,7 1,14 1,98  
[2.232 0.045] [0.078]  
59,6 1,0 2,80  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZE6-2RN80  
BZE6-2RN8034  
DTE6-2RN80  
2,50 to 6,67  
[9 to24]  
5,56  
[0.219]  
0,05  
[0.002]  
Low temperature  
-40 °C [-40 °F]  
5,56 to 13,3  
3,17  
[0.125]  
1,52  
[0.060]  
Double pole  
applications  
[20 to 48] [2.345 0.040] [0.110]  
Low temp. -40 °C  
[-40 °F], M20 -1,5  
[0.060] conduit, Double pole  
applications  
Inline Roller Plunger  
DTE6-  
2RN8034-M  
DT,  
B,  
5,56 to 13,3  
[20 to 48] [2.345 0.040] [0.110]  
59,6 1,0  
2,80  
3,17  
[0.125]  
1,52  
DPDT 10 A  
BZ,  
SPDT 15 A  
A,  
2,50 to 6,67  
[9 to24]  
56,7 1,14  
[2.232 0.045] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZE6-2RN81  
Cross Roller  
Plunger  
sensing.honeywell.com  
8
MICRO SWITCH™ Medium-Duty Limit Switches  
Table 6, continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
A,  
2,78 to 5,57  
[10 to 20]  
71,42 Ref  
[2.812]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
BZE6-2RN2  
BZE6-2RN2-S  
BZE6-2RN234  
BZE6-2RN272  
DTE6-2RN2  
2,78 to 5,57  
[10 to 20]  
71,42 Ref  
[2.812]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
0.5-14 NPSM  
conduit thread  
2,78 to 5,57  
[10 to 20]  
71,42 Ref  
[2.812]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
Low temperature  
-40 °C [-40 °F]  
BZ,  
SPDT  
H,  
1 A  
2,78 to 5,57  
[10 to 20]  
71,42 Ref  
[2.812]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
Gold-plated  
contacts  
Roller Lever  
DT,  
B,  
2,78 to 8,35  
[10 to 30]  
69,44 Ref  
[2.734]  
6,76  
[0.266]  
5,56  
[0.219]  
4,19  
[0.165]  
Double pole  
applications  
DPDT 10 A  
BZ, A,  
SPDT 15 A  
2,22 to 5,56  
[8 to 20]  
5,94  
[0.234]  
5,56  
[0.219]  
0,15  
[0.006]  
BZE6-2RN28  
BZE6-2RN28-S  
DTE6-2RN28  
-
-
-
BZ,  
A,  
2,22 to 5,56  
[8 to 20]  
5,94  
[0.234]  
5,56  
[0.219]  
0,15  
[0.006]  
0.5-14 NPSM  
conduit thread  
SPDT 15 A  
DT,  
B,  
5,56 to10  
[20 to 36]  
7,92  
[0.312]  
5,56  
[0.219]  
4,19  
[0.165]  
Double pole  
applications  
One-way Roller  
Lever  
DPDT 10 A  
BZ,  
SPDT 15 A  
A,  
0,83 to 1,95  
[3 to 7]  
18,24  
[0.718]  
21,29  
[838]  
5,82  
[0.229]  
BZE6-2RN62  
-
Low-force Rod  
Lever  
1,95 N max.  
[7.0 oz  
BZ,  
SPDT 15 A  
A,  
BZE6-2RN18  
-
-
15°  
15°  
20° Ref  
20° Ref  
-
-
max.]  
1,95 N max.  
[7.0 oz  
BZ,  
SPDT  
H,  
1 A  
Gold-plated  
contacts  
BZE6-2RN1872  
max.]  
Coil-spring Wobble  
Manual Palm Button  
BZ,  
SPDT 15 A  
A,  
2,78 to 5,57  
[10 to 20]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
BZE6-2RN4  
80,0 Ref [3.15]  
sensing.honeywell.com  
9
E6/V6 Series  
Table 6. continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
A,  
1,67 to 5,56 43,64 0,76  
1,98  
5,56  
[0.219]  
Reset position:  
53,19 [2.094] max.  
BZE6-RNX1  
NA  
NA  
[6 to 20]  
[1.718 0.030] [0.078]  
Pin Plunger w  
Manual Reset  
56,70 1,14  
1,98  
BZ,  
SPDT 15 A  
A,  
5,85 to 15,57  
[21 to 56]  
4,75  
[0.187]  
Reset position:  
53,19 [2.094] max.  
BZE6-RN80X2  
[2.232  
[0.078]  
0.045]  
Inline roller plunger  
w/ manual reset  
Reset position:  
50,40 1,14  
[1.984 0.045]  
BZ,  
A,  
4,45 N max.  
71,42 Ref  
[2.812 in.]  
4,83  
[0.188]  
5,56  
[0.219]  
BZE6-RN2X1  
NA  
SPDT 15 A [16 oz max.]  
Roller Lever w/  
Manual Reset  
Reset position:  
50,40 1,14  
[1.984 0.045]  
BZ,  
A,  
1,95 N max.  
BZE6-RN18X1  
-
15°  
20° Ref  
NA  
SPDT 15 A [7.0 oz max.]  
Coil Spring Wobble  
w/ Manual Reset  
sensing.honeywell.com  
10  
MICRO SWITCH™ Medium-Duty Limit Switches  
DIMENSIONS  
Figure 2.Top pin plunger, side mount with boot seal  
Figure 3.Top roller plunger, side mount with boot seal  
Ø 8,44 mm  
[Ø 0.33 in]  
ref. 2,0 mm  
[ref. 0.08 in]  
23,4 mm  
[0.92 in]  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
1/2-14 NPT  
Threads  
56,64 mm  
[2.23 in]  
43,7 mm OP  
[1.72 in OP]  
1/2-14 NPT  
Threads  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
22,6 mm  
[1.00 in]  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
77,2 mm  
[3.04 in]  
25,4 mm  
[1.00 in]  
25,4 mm [1.00 in]  
21,1 mm  
[0.83 in]  
69,6 mm  
[2.74 in]  
21,1 mm  
[0.83 in]  
Figure 4. Cross roller plunger, side mount with boot seal  
Figure 5. Roller lever, adjustable, side mount with boot seal  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
39,6 mm  
roller  
[1.57 in]  
18,3 mm  
[0.72 in]  
56,64 mm  
1/2-14 NPT  
[2.23 in]  
23,1 mm  
[0.91 in]  
Threads  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
25,4 mm  
22,6 mm  
[1.00 in]  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm [1.00 in]  
69,6 mm [2.74 in]  
Figure 7. Rod lever, side mount with boot seal  
Figure 6. One-way roller lever, side mount with boot seal  
152,4 mm [6.0 in]  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
18,3 mm  
[0.72 in]  
roller  
18,3 mm  
[0.72 in]  
32,26 mm  
[1.27 in]  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
22,6 mm  
[1.00 in]  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
25,4 mm [1.00 in]  
69,6 mm [2.74 in]  
25,4 mm  
77,2 mm [3.04 in]  
[1.00 in]  
sensing.honeywell.com  
11  
E6/V6 Series  
Figure 8. Manual palm button, side mount with boot seal  
Figure 9. Coil wobble, side mount with boot seal  
Ø 7,11 mm [Ø 0.28 in]  
36,58 mm [1.44 in]  
38,1 mm  
18,3 mm  
[0.72 in]  
[1.50 in]  
108,97 mm  
[4.29 in]  
31,75 mm  
[1.25 in]  
149,35 mm  
[5.88 in]  
1/2-14 NPT  
Threads  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
25,4 mm  
22,6 mm  
[1.00 in]  
25,4 mm  
22,6 mm  
[0.89 in]  
[1.00 in]  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm [1.00 in]  
69,6 mm [2.74 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
77,2 mm [3.04 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
Figure 10.Top pin plunger, reset, side mount with boot seal  
Figure 11.Top roller plunger, reset, side mount with boot seal  
Ø 8,44 mm  
[Ø 0.33 in]  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
56,64 mm  
[2.23 in]  
1/2-14 NPT  
Threads  
1/2-14 NPT  
Threads  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
25,4 mm  
[1.00 in]  
25,4 mm  
25,4 mm  
[1.00 in]  
[1.00 in]  
[1.00 in]  
69,6 mm [2.74 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
77,2 mm [3.04 in]  
Figure 12. Roller lever plunger, reset, side mount with boot seal Figure 13. Coil wobble plunger, reset, side mount with boot seal  
Ø 7,11 mm [Ø 0.28 in]  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
39,6 mm  
roller  
[1.57 in]  
18,3 mm  
[0.72 in]  
108,97 mm  
[4.29 in]  
23,1 mm  
[0.91 in]  
149,35 mm  
[5.88 in]  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
1/2-14 NPT  
Threads  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
sensing.honeywell.com  
12  
MICRO SWITCH™ Medium-Duty Limit Switches  
Table 7. Order Guide • E6 Series Switches, Side Mount without Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
A,  
2,50 to 3,61  
[9 to 13]  
38,1 0,76  
[1.5 0.030]  
38,1 0,76  
[1.5 0.030]  
38,1 0,76  
[1.5 0.030]  
38,1 0,76  
[1.5 0.030]  
38,1 0,76  
[1.5 0.030]  
0,38  
[0.015]  
0,38  
[0.015]  
0,38  
[0.015]  
0,38  
[0.015]  
0,38  
5,56  
[0.219]  
5,56  
[0.219]  
5,56  
[0.219]  
5,56  
[0.219]  
5,56  
[0.219]  
2,24  
[0.088]  
3,56  
[0.140]  
3,56  
[0.140]  
3,56  
[0.140]  
3,56  
[0.140]  
3,56  
[0.140]  
3,56  
[0.140]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
1,52  
[0.060]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
BZE6-2RQ  
BZE6-2RQ-S  
BZE6-2RQ7  
BZE6-2RQ72  
BME6-2RQ  
2,50 to 3,61  
[9 to 13]  
0.5-14 NPSM  
conduit thread  
2,50 to 3,61  
[9 to 13]  
#8 mounting screws  
BZ,  
SPDT  
BM,  
H,  
1 A  
G,  
2,50 to 3,61  
[9 to 13]  
Gold-plated  
contacts  
Pin Plunger  
2,50 to 3,61  
[9 to 13]  
Higher current ac  
applications  
Double pole  
applications  
SPDT 22 A  
DT, B,  
DPDT 10 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
[0.015]  
3,81  
5,56 to 11,12 47,88 0,76  
[20 to 40]  
2,50 to 3,61 49,61 1,14  
[9 to 13] [1.953 0.045] [0.015]  
2,50 to 3,61 49,61 1,14 0,38  
[9 to 13] [1.953 0.045] [0.015]  
2,50 to 3,61 49,61 1,14 0,38  
[9 to 13] [1.953 0.045] [0.015]  
2,50 to 3,61 49,61 1,14 0,38  
[9 to 13] [1.953 0.045] [0.015]  
2,50 to 3,61 49,61 1,14 0,38  
[9 to 13] [1.953 0.045] [0.015]  
2,50 to 3,61 49,61 1,14 0,38  
[1.953 0.045] [0.015]  
DTE6-2RQ  
[1.885 0.030] [0.150]  
0,38  
BZE6-2RQ8  
BZE6-2RQ8-S  
BZE6-2RQ8722  
BZE6-2RQ81  
BZE6-2RQ81-S  
BME6-2RQ81  
0.5-14 NPSM  
conduit thread  
Gold-plated  
contacts  
BZ,  
SPDT  
BZ,  
H,  
1 A  
A,  
Inline Roller Plunger  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
BM, G,  
SPDT 22 A  
0.5-14 NPSM  
conduit thread  
Higher current ac  
applications  
[9 to 13]  
6,67 to  
13,34  
Cross Roller  
Plunger  
DT,  
B,  
49,61 1,14  
[1.953 0.045] [0.141]  
3,58  
3,18  
[0.125]  
1,52  
[0.060]  
Double pole  
applications  
DTE6-2RQ81  
DPDT 10 A  
[24 to 48]  
2,78 to 5,00  
[10 to 18]  
2,78 to 5,00  
[10 to 18]  
2,78 to 5,57  
[10 to 20]  
BZ,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
DT, B,  
DPDT 10 A  
A,  
61,11 Ref  
[2.406]  
4,83  
[0.188]  
4,83  
[0.188]  
6,76  
5,56  
[0.219]  
5,56  
[0.219]  
5,56  
0,15  
[0.006]  
0,15  
[0.006]  
4,19  
BZE6-2RQ2  
BZE6-2RQ2-S  
DTE6-2RQ2  
61,11 Ref  
[2.406]  
0.5-14 NPSM  
conduit thread  
Double pole  
applications  
69,44 Ref  
[2.734]  
Roller Lever  
[0.266]  
[0.219]  
[0.165]  
BZ,  
SPDT 15 A  
A,  
2,22 to 5,00  
[8 to 18]  
5,94  
[0.234]  
5,56  
[0.219]  
0,15  
[0.006]  
BZE6-2RQ28  
-
One-way Roller  
Lever  
BZ,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
DT, B,  
DPDT 10 A  
A,  
0,56 to 1,39  
[2 to 5]  
18,24  
[0.718]  
18,24  
[0.718]  
27,94  
21,29  
[0.838]  
21,29  
[0.838]  
21,29  
5,82  
[0.229]  
5,82  
[0.229]  
14,22  
[0.560]  
BZE6-2RQ62  
BZE6-2RQ62-S  
DTE6-2RQ62  
-
-
-
0,56 to 1,39  
[2 to 5]  
0.5-14 NPSM  
conduit thread  
Double pole  
applications  
1,39 to 3,34  
[5 to 12]  
Low-force Rod  
Lever  
[1,100]  
[0.838]  
sensing.honeywell.com  
13  
E6/V6 Series  
Table 7, continued. Order Guide • E6 Series Switches, Side Mount without Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
A,  
2,78 to 5,00  
[10 to 18]  
5,56  
[0.219]  
0,15  
[0.006]  
BZE6-2RQ4  
BZE6-RQX2  
-
-
Manual Palm Button  
BZ,  
SPDT 15 A  
A,  
1,67 to 2,64  
[6 to 9.5]  
38,1 0,76  
[1.5 0.030]  
0,30  
[0.012]  
4,75  
[0.187]  
Reset position:  
46,84 [1.844] max.  
NA  
NA  
Pin Plunger w  
Manual Reset  
BZ,  
SPDT 15 A  
A,  
1,47 to 2,64 51,18 1,14  
[6 to 9.5]  
0,30  
3,56  
[0.140]  
Reset position:  
46,84 [1.844] max.  
BZE6-RQ8X2  
[2.015 0.045] [0.012]  
Inline Roller Plunger  
w/ Manual Reset  
BZ,  
SPDT 15 A  
A,  
1,47 to 2,64 51,18 1,14  
0,30  
3,56  
[0.140]  
Reset position:  
46,84 [1.844] max.  
BZE6-RQ81X2  
NA  
[6 to 9.5]  
[2.015 0.045] [0.012]  
Cross Roller  
Plunger w/ Manual  
Reset  
3,34  
approx.  
[12 oz ]  
BZ,  
SPDT 15 A  
A,  
61,11 Ref  
[2.406]  
4,83  
[0.188]  
5,56  
[0.219]  
Reset position:  
46,84 [1.844] max.  
BZE6-RQ2X2  
NA  
Roller Lever w/  
Manual Reset  
sensing.honeywell.com  
14  
MICRO SWITCH™ Medium-Duty Limit Switches  
DIMENSIONS  
Figure 14.Top pin plunger, side mount  
Figure 15.Top roller plunger, side mount  
Ø 8,44 mm  
[Ø 0.33 in]  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
23,4 mm  
[0.92 in]  
1/2-14 NPT  
Threads  
49,61 mm  
[1.95 in]  
1/2-14 NPT  
Threads  
38,1 mm  
[1.50 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm [1.00 in]  
77,2 mm  
[3.04 in]  
25,4 mm  
[1.00 in]  
69,6 mm  
[2.74 in]  
25,4 mm  
[1.00 in]  
77,2 mm [3.04 in]  
Figure 17. Roller lever, adjustable, side mount  
Figure 16. Cross roller plunger, side mount  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
39,6 mm  
roller  
[1.57 in]  
roller  
49,61 mm  
[1.95 in]  
1/2-14 NPT  
Threads  
18,3 mm  
[0.72 in]  
23,1 mm  
[0.91 in]  
1/2-14 NPT  
42,9 mm  
25,4 mm  
[1.00 in]  
Threads  
[1.69 in]  
22,6 mm  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
25,4 mm  
22,6 mm  
[1.00 in]  
[0.89 in]  
25,4 mm [1.00 in]  
69,6 mm [2.74 in]  
25,4 mm  
[1.00 in]  
77,2 mm [3.04 in]  
Figure 18. One-way roller lever, side mount  
Figure 19. Rod lever, side mount  
152,4 mm [6.0 in]  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
roller  
18,3 mm  
[0.72 in]  
18,3 mm  
[0.72 in]  
32,26 mm  
[1.27 in]  
1/2-14 NPT  
Threads  
42,93 mm  
[1.69 in]  
42,93 mm  
[1.69 in]  
1/2-14 NPT  
Threads  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
sensing.honeywell.com  
15  
E6/V6 Series  
Figure 20. Manual palm button, side mount  
Figure 21.Top pin plunger, reset, side mount  
Ø 8,44 mm  
[Ø 0.33 in]  
38,1 mm  
[1.50 in]  
18,3 mm  
[0.72 in]  
1/2-14 NPT  
Threads  
31,75 mm  
[1.25 in]  
1/2-14 NPT  
Threads  
42,93 mm  
[1.69 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
25,4 mm [1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
77,2 mm [3.04 in]  
Figure 22. Roller plunger, reset, side mount  
Figure 23. Cross roller plunger, reset, side mount  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
1/2-14 NPT  
Threads  
49,61 mm  
[1.95 in]  
1/2-14 NPT  
Threads  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
Figure 24. Roller lever, reset, side mount  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
roller  
39,6 mm  
[1.57 in]  
18,3 mm  
[0.72 in]  
23,1 mm  
[0.91 in]  
1/2-14 NPT  
Threads  
42,9 mm  
[1.69 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
sensing.honeywell.com  
16  
MICRO SWITCH™ Medium-Duty Limit Switches  
Table 8. Order Guide • V6 Series Switches, Flange Mount with Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
BZ, A,  
SPDT 15 A  
DT, B,  
DPDT 10 A  
A,  
2,50 to 6,67 69,09 1,52  
[9 to 24] [2.720 0.060] [0.078]  
2,50 to 6,67 69,09 1,52 1,98  
[9 to 24] [2.720 0.060] [0.078]  
2,50 to 6,67 69,09 1,52 1,98  
[9 to 24] [2.720 0.060] [0.078]  
7,23 to 16,4 71,42 0,76 2,79  
[26 to 59] [2.812 0.030] [0.110]  
1,98  
5,56  
[0.219]  
5,56  
[0.219]  
5,56  
[0.219]  
3,18  
[0.125]  
0,05  
[0.002]  
0,05  
[0.002]  
0,05  
[0.002]  
1,52  
[0.060]  
BZV6-2RN  
BZV6-2RN-S  
BZV6-2RN34  
DTV6-2RN  
0.5-14 NPSM  
conduit thread  
Low temperature  
-40 °C [-40 °F]  
Double pole  
Pin plunger  
applications  
BZ,  
SPDT 15 A  
A,  
2,50 to 6,67 82,09 1,14  
[9 to24] [3.232 0.045] [0.078]  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
BZV6-2RN80  
BZV6-2RN81  
Inline Roller Plunger  
BZ,  
SPDT 15 A  
A,  
2,50 to 6,67 82,09 1,14  
1,98  
5,56  
[0.219]  
0,05  
[0.002]  
[9 to24]  
[3.232 0.045] [0.078]  
Cross Roller  
Plunger  
BZ,  
SPDT 15 A  
A,  
2,78 to 5,57  
[10 to 20]  
96,82 Ref  
[3.812]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
BZV6-2RN2  
DTV6-2RN2  
DT,  
B,  
2,78 to 8,35  
[10 to 30]  
94,84 Ref  
[3.734]  
6,76  
[0.266]  
5,56  
[0.219]  
4,19  
[0.165]  
Double pole  
applications  
DPDT 10 A  
Roller Lever  
BZ,  
SPDT 15 A  
A,  
2,22 to 5,56  
[8 to 20]  
5,94  
[0.234]  
5,56  
[0.219]  
0,15  
[0.006]  
BZV6-2RN28  
BZV6-2RN62  
-
-
One-way Roller  
Lever  
BZ,  
SPDT 15 A  
A,  
0,83 to 1,95  
[3 to 7]  
18,24  
[0.718]  
21,29  
[0.838]  
5,82  
[0.229]  
Low-force Rod  
Lever  
sensing.honeywell.com  
17  
E6/V6 Series  
Table 8, continued. Order Guide • V6 Series Switches, Flange Mount with Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
A,  
1,95 N. max.  
BZV6-2RN18  
-
15°  
20° Ref  
-
SPDT 15 A [7.0 oz max.]  
Coil-spring Wobble  
BZ,  
SPDT 15 A  
A,  
2,78 to 5,57  
[10 to 20]  
105,56 Ref.  
[4.156]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
BZV6-2RN4  
Manual Palm Button  
BZ,  
SPDT 15 A  
A,  
1,67 to 5,56 69,09 1,52  
[6 to 20]  
1,98  
4,78  
[0.188]  
Reset position:  
26,97 [1.062] max.  
BZV6-RNX1  
NA  
[2.720 0.060] [0.078]  
Pin Plunger w  
Manual Reset  
sensing.honeywell.com  
18  
MICRO SWITCH™ Medium-Duty Limit Switches  
DIMENSIONS  
Figure 25.Top pin plunger, flange mount with boot seal  
Figure 26.Top roller plunger, flange mount with boot seal  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
2,0 mm  
[0.08 in]  
Ø 8,44 mm  
[Ø 0.33 in]  
82,04 mm  
[3.23 in]  
1/2-14 NPT  
Threads  
1/2-14 NPT  
Threads  
69,1 mm  
[2.72 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
44,4 mm  
[1.75 in]  
44,4 mm  
[1.75 in]  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
10,7 mm  
[0.42 in]  
3,3 mm  
[0.13 in]  
25,4 mm  
[1.00 in]  
41,4 mm [1.63 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
69,6 mm  
[2.74 in]  
54,1 mm [2.13 in]  
54,1 mm [2.13 in]  
Figure 27. Cross roller plunger, flange mount with boot seal  
Figure 28. Roller lever adjustable, flange mount with boot seal  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
roller  
39,6 mm  
roller  
[1.57 in]  
56,64 mm  
[2.23 in]  
18,3 mm  
[0.72 in]  
1/2-14 NPT  
23,1 mm  
[0.91 in]  
Threads  
2X Ø 4,37 mm  
[Ø 0.172 in]  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
77,2 mm [3.04 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
54,1 mm [2.13 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
54,1 mm [2.13 in]  
Figure 30. Rod lever, flange mount with boot seal  
Figure 29. One-way roller lever, flange mount with boot seal  
152,4 mm [6.0 in]  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
18,3 mm  
[0.72 in]  
roller  
18,3 mm  
[0.72 in]  
32,26 mm  
[1.27 in]  
53,1 mm  
1/2-14 NPT  
[2.09 in]  
53,1 mm  
[2.09 in]  
Threads  
1/2-14 NPT  
Threads  
2X Ø 4,37 mm  
[Ø 0.172 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
22,6 mm  
[1.00 in]  
[0.89 in]  
10,7 mm  
[0.42 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
3,3 mm  
[0.13 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
41,4 mm [1.63 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
77,2 mm [3.04 in]  
54,1 mm [2.13 in]  
54,1 mm [2.13 in]  
sensing.honeywell.com  
19  
E6/V6 Series  
Figure 31. Manual palm button, flange mount with boot seal  
Figure 32. Coil wobble, flange mount with boot seal  
Ø 7,11 mm [Ø 0.28 in]  
38,1 mm  
18,3 mm  
[0.72 in]  
[1.50 in]  
108,97 mm  
[4.29 in]  
31,75 mm  
[1.25 in]  
149,35 mm  
[5.88 in]  
1/2-14 NPT  
Threads  
53,1 mm  
[2.09 in]  
1/2-14 NPT  
Threads  
2X Ø 4,37 mm  
[Ø 0.172 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
25,4 mm  
[1.00 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
3,3 mm  
[0.13 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
41,4 mm [1.63 in]  
54,1 mm [2.13 in]  
54,1 mm [2.13 in]  
Figure 33.Top pin plunger, reset, flange mount with boot seal  
Ø 8,44 mm  
[Ø 0.33 in]  
10,7 mm  
[0.42 in]  
1/2-14 NPT  
Threads  
2X Ø 4,37 mm  
[Ø 0.172 in]  
22,6 mm  
[0.89 in]  
3,3 mm  
[0.13 in]  
25,4 mm  
25,4 mm  
[1.00 in]  
[1.00 in]  
69,6 mm [2.74 in]  
41,4 mm [1.63 in]  
77,2 mm [3.04 in]  
54,1 mm [2.13 in]  
sensing.honeywell.com  
20  
MICRO SWITCH™ Medium-Duty Limit Switches  
Table 9. Order Guide • V6 Series Switches, Flange Mount without Boot Seal  
For catalog listings not shown, please contact your Honeywell distributor or representative.  
Catalog Listing  
Comments  
BZ,  
SPDT 15 A  
A,  
2,50 to 3,61 63,50 1,14  
[9 to 13] [2.50 0.045]  
0,38  
[0.015]  
5,56  
[0.219]  
0,05  
[0.002]  
BZV6-2RQ  
Pin plunger  
BZ,  
SPDT 15 A  
A,  
2,50 to 3,61 75,01 1,52  
[9 to 13]  
0,38  
3,56  
[0.140]  
0,05  
[0.002]  
BZV6-2RQ8  
[2.953 0.060] [0.015]  
Inline Roller Plunger  
BZ,  
SPDT 15 A  
A,  
2,50 to 3,61 75,01 1,52  
0,38  
3,56  
[0.140]  
0,05  
[0.002]  
BZV6-2RQ81  
[9 to 13]  
[2.953 0.060] [0.015]  
Cross Roller  
Plunger  
BZ,  
SPDT 15 A  
A,  
2,78 to 5,00  
[10 to 18]  
86,51 Ref  
[3.406]  
4,83  
[0.188]  
5,56  
[0.219]  
0,15  
[0.006]  
BZV6-2RQ2  
Roller Lever  
BZ,  
SPDT 15 A  
A,  
0,56 to 1,39  
[2 to 5]  
18,24  
[0.718]  
21,29  
[0.838]  
5,82  
[0.229]  
BZV6-2RQ62  
-
Low-force Rod  
Lever  
sensing.honeywell.com  
21  
E6/V6 Series  
DIMENSIONS  
Figure 34.Top pin plunger, flange mount  
Figure 35.Top roller plunger, flange mount  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
roller  
Ø 8,44 mm  
[Ø 0.33 in]  
74,93 mm  
[2.95 in]  
1/2-14 NPT  
Threads  
1/2-14 NPT  
Threads  
63,5 mm  
[2.50 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
44,4 mm  
44,4 mm  
[1.75 in]  
[1.75 in]  
22,6 mm  
[0.89 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm  
[2.74 in]  
3,3 mm  
[0.13 in]  
3,3 mm  
[0.13 in]  
41,4 mm [1.63 in]  
41,4 mm [1.63 in]  
54,1 mm [2.13 in]  
54,1 mm [2.13 in]  
Figure 36. Cross roller plunger, flange mount  
Figure 37. Roller lever adjustable, flange mount  
Ø 19,0 mm [0.75 in] x  
6,4 mm [0.25 in] W  
Ø12,7 mm [0.50 in] x  
4,6 mm [0.18 in] W  
39,6 mm  
roller  
roller  
[1.57 in]  
18,3 mm  
[0.72 in]  
74,9 mm  
[2.95 in]  
1/2-14 NPT  
Threads  
23,1 mm  
[0.91 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
44,4 mm  
[1.75 in]  
22,6 mm  
[0.89 in]  
1/2-14 NPT  
Threads  
42,9 mm  
[1.69 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
3,3 mm  
[0.13 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
41,4 mm [1.63 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
54,1 mm [2.13 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
3,3 mm  
[0.13 in]  
Figure 38. Rod lever, flange mount  
41,4 mm [1.63 in]  
152,4 mm [6.0 in]  
54,1 mm [2.13 in]  
18,3 mm  
[0.72 in]  
1/2-14 NPT  
Threads  
42,93 mm  
[1.69 in]  
2X Ø 4,37 mm  
[Ø 0.172 in]  
25,4 mm  
[1.00 in]  
22,6 mm  
[0.89 in]  
25,4 mm  
[1.00 in]  
10,7 mm  
[0.42 in]  
3,3 mm  
[0.13 in]  
69,6 mm [2.74 in]  
77,2 mm [3.04 in]  
41,4 mm [1.63 in]  
54,1 mm [2.13 in]  
sensing.honeywell.com  
22  
MICRO SWITCH™ Medium-Duty Limit Switches  
E6/V6 REPLACEMENT PARTS  
The metal bottom cover includes the insulator seal and two cover screws  
The plunger seal boot includes the plunger seal and retaining hardware  
The hardware packet includes mounting hardware and seal boot as noted in the tables  
Table 10. Actuator with Boot Seal Replacement Parts  
Plunger Seal  
Boot1  
Internal Basic  
Switch  
Cat. Listing  
Bottom Cover  
Hardware Packet  
Actuator  
BZE6-2RN  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA13-E6  
3PA13-E6  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
10PA2  
1PA2*  
1PA2*  
1PA46*2  
1PA2*  
1PA47  
1PA13*  
1PA13*  
-
BZ-2RQ77**  
BZ-2RQ77**  
BZ-2RN730**  
BZ-2RQ7722**  
BZ-2RN784  
BZ-2RN702**  
BZ-2RN702**  
BZ-2R-A2  
Integral to internal basic switch  
BZV6-2RN  
Integral to internal basic switch  
BZE6-2RN7  
BZE6-2RN72  
BZE6-2RN80  
BZE6-2RN2  
BZV6-2RN2  
BZE6-2RN18  
BZV6-2RN18  
DTE6-2RN  
Integral to internal basic switch  
Integral to internal basic switch  
Integral to internal basic switch  
6PA2*  
6PA2*  
6PA1953  
6PA1953  
8PA14  
8PA14  
6PA2*  
-
BZ-2R-A2  
1PA2  
1PA2  
-
DT-2R3-A7  
DT-2R3-A7  
DT-2R3-A7  
DT-2R3-A7  
DTV6-2RN  
DTE6-2RN2  
DTV6-2RN2  
-
6PA2*  
*Includes plunger seal boot  
**Includes hardware packet  
1. To order replacement low temperature plunger boot seal (switch code 34), specify 10PA1  
2. 1PA46 hardware packet cannot be ordered separately. When BZ-2RN730 internal basic switch is ordered, the 1PA46 hardware packet  
is included with internal basic switch.  
3. To order replacement wobble actuator including internal threaded bushing, specify 6PA188-F  
Table 11. Actuator without Boot Seal Replacement Parts  
Cat. Listing  
Bottom Cover  
Hardware Packet  
Internal Basic Switch  
Actuator  
BZE6-2RQ  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
3PA13-E6  
3PA14-V6  
1PA1  
1PA1  
BZ-2RQ66  
BZ-2RQ66  
Integral to internal basic switch  
Integral to internal basic switch  
Integral to internal basic switch  
Integral to internal basic switch  
Integral to internal basic switch  
Integral to internal basic switch  
6PA1  
BZV6-2RQ  
BZE6-2RQ8  
BZV6-2RQ8  
BZE6-2RQ81  
BZV6-2RQ81  
BZE6-2RQ2  
BZV6-2RQ2  
1PA19  
1PA19  
1PA19  
1PA19  
1PA3  
BZ-2RQ784**  
BZ-2RQ784**  
BZ-2RQ785**  
BZ-2RQ785**  
BZ-2RQ68**  
BZ-2RQ68**  
1PA3  
6PA1  
**Includes hardware packet  
sensing.honeywell.com  
23  
E6/V6 Series  
This Honeywell datasheet supports the following MICRO SWITCH™ E6/V6 Series Limit Switch Listings  
BZE6-2RN4  
BZE6-2RN7  
BZE6-2RN80  
BZE6-2RQ2  
BZE6-RN80X2  
BZE6-2AQ  
BZE6-2AQ8T  
BZE6-2GN  
BZE6-2RN  
BZE6-2RN72-S  
BZE6-2RN7-S  
BZE6-2RN8  
BZE6-3YNP  
BZE6-3YNT  
BZE6-3YQ9  
BZE6-3YQT  
BZE6-7RN  
BZE6-7RN18  
BZE6-7RN1812  
BZE6-7RN51  
BZE6-7RN8051  
BZE6-7RNT  
BZE6-7RQ8  
BZE6-7RQ9  
BZE6-7RQ9T  
BZE6-RN  
BZE6-RN18X1  
BZE6-RN18X2  
BZE6-RN18X3  
BZE6-RN2X1  
BZE6-RNX1  
BZE6-RNX12  
BZE6-RNX17  
BZE6-RQ  
BZV6-2RQ2  
BZV6-2RQ39  
BZV6-2RQ62  
BZV6-2RQ8  
BZV6-2RQ81  
BZV6-2RQ9  
BZV6-7RN  
BZV6-7RN2T  
BZV6-RNX1  
10PA1  
BZE6-2RN8034  
BZE6-2RN81  
BZE6-2RN-C  
BZE6-2RN-F1  
BZE6-2RN-F3  
BZE6-2RN-F6  
BZE6-2RN-FR  
BZE6-2RN-M  
BZE6-2RN-R  
BZE6-2RN-S  
BZE6-2RQ  
BZE6-2RQ125  
BZE6-2RQ136  
BZE6-2RQ165  
BZE6-2RQ168  
BZE6-2RQ219  
BZE6-2RQ241  
BZE6-2RQ28  
BZE6-2RQ2-S  
BZE6-2RQ4  
BZE6-2RN18  
BZE6-2RN1809-5  
BZE6-2RN1810  
BZE6-2RN1812  
BZE6-2RN183  
BZE6-2RN185  
BZE6-2RN185-WP  
BZE6-2RN187  
BZE6-2RN1872  
BZE6-2RN18721  
BZE6-2RN18-C3  
BZE6-2RN19  
BZE6-2RN191-S  
BZE6-2RN193  
BZE6-2RN196-F5  
BZE6-2RN2  
BZE6-2RN221  
BZE6-2RN224  
BZE6-2RN234  
BZE6-2RN272  
BZE6-2RN28  
BZE6-2RN281  
BZE6-2RN28-S  
BZE6-2RN2-F3  
BZE6-2RN2-F6  
BZE6-2RN2-S  
BZE6-2RN2-TW  
BZE6-2RN34  
BZE6-2RN37  
BZE6-2RN39  
BZE6-2RN5  
10PA2  
19PA22-E6  
3PA13-E6  
3PA14-V6  
6PA140-E6  
6PA147-E6  
6PA148-E6  
6PA187-E6  
BME6-2RN  
BME6-2RN2  
BME6-2RN373  
BME6-2RQ  
BME6-2RQ171  
BME6-2RQ173  
BME6-2RQ273  
BME6-2RQ81  
DTE6-2RN  
DTE6-2RN2  
DTE6-2RN28  
DTE6-2RN281  
DTE6-2RN4  
DTE6-2RN80  
DTE6-2RN8034-M  
DTE6-2RQ  
BZE6-RQ2  
BZE6-2RQ5  
BZE6-RQ2X2  
BZE6-RQ71  
BZE6-RQ81X2  
BZE6-RQ8X2  
BZE6-RQ8X4  
BZE6-RQ9  
BZE6-2RQ62  
BZE6-2RQ62-S  
BZE6-2RQ7  
BZE6-2RQ72  
BZE6-2RQ8  
BZE6-2RQ81  
BZE6-2RQ814  
BZE6-2RQ81-S  
BZE6-2RQ841-BP  
BZE6-2RQ8722  
BZE6-2RQ8-S  
BZE6-2RQ9  
BZE6-2RQ9-S  
BZE6-2RQ-S  
BZE6-3RN  
BZE6-RQX2  
BZV6-2RN  
BZV6-2RN18  
BZV6-2RN2  
BZV6-2RN28  
BZV6-2RN34  
BZV6-2RN4  
BZV6-2RN62  
BZV6-2RN80  
BZV6-2RN81  
BZV6-2RN-C  
BZV6-2RN-S  
BZV6-2RQ  
DTE6-2RQ2  
DTE6-2RQ62  
DTE6-2RQ81  
DTE6-2RQ9  
DTV6-2RN  
DTV6-2RN2  
DTV6-2RN4  
HSE6-3RNT2  
BZE6-3RN18150-C  
BZE6-3RN2153  
BZE6-3YN2  
BZE6-2RN51  
BZE6-2RN62  
BZE6-2RN72  
sensing.honeywell.com  
24  
MICRO SWITCH™ Medium-Duty Limit Switches  
ADDITIONAL INFORMATION  
WARNING  
The following associated literature is available on the Honeywell web  
PERSONAL INJURY  
site at sensing.honeywell.com:  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
• Product installation instructions  
• Product range guide  
• Product nomenclature tree  
Failure to comply with these instructions could result in  
death or serious injury.  
• Product application-specific information  
– Limit and enclosed switch reference standards  
– Application note: Machine tool application guide  
– Application note: Industrial machinery switch guide  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywells standard  
product warranty applies unless agreed to otherwise by Honeywell  
in writing; please refer to your order acknowledgement or consult  
your local sales office for specific warranty details. If warranted  
goods are returned to Honeywell during the period of coverage,  
Honeywell will repair or replace, at its option, without charge those  
items it finds defective. The foregoing is buyer’s sole remedy  
and is in lieu of all other warranties, expressed or implied,  
including those of merchantability and fitness for a particu-  
lar purpose. In no event shall Honeywell be liable for conse-  
quential, special, or indirect damages.  
While we provide application assistance personally, through our  
literature and the Honeywell website, it is up to the customer to  
determine the suitability of the product in the application.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this printing.  
However, we assume no responsibility for its use.  
sensing.honeywell.com  
25  
Find out more  
Honeywell serves its customers  
through a worldwide network  
of sales offices, representatives  
and distributors. For application  
assistance, current specifications,  
pricing or name of the nearest  
Authorized Distributor, contact  
your local sales office.  
To learn more about Honeywell’s  
sensing and control products,  
call +1-815-235-6847 or  
1-800-537-6945,  
visit sensing.honeywell.com,  
or e-mail inquiries to  
info.sc@honeywell.com  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
Golden Valley, MN 55422  
honeywell.com  
002383-2-EN IL50 GLO  
December 2014  
Copyright © 2014 Honeywell International Inc. All rights reserved.  

相关型号:

BZV6-2RN28

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 11.5mm, Screw Terminal, Steel Roller Lever Plunger Actuator, Panel Mount-threaded,
HONEYWELL

BZV6-2RN80

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 7.54mm, Screw Terminal, Steel Roller Plunger Actuator, Panel Mount,
HONEYWELL

BZV6-2RN81

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 7.54mm, Screw Terminal, Steel Roller Plunger Actuator, Panel Mount
HONEYWELL

BZV6-2RQ39

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 250VDC, 3.28mm, Wire Terminal, Long Bar Actuator, Panel Mount
HONEYWELL

BZV6-2RQ81

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 3.96mm, Screw Terminal, Steel Roller Actuator, Panel Mount-threaded
HONEYWELL

BZV6-7RN

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 7.54mm, Screw Terminal, Steel Plunger Actuator, Panel Mount
HONEYWELL

BZV6-7RN2T

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 250VDC, 8.55mm, Wire Terminal, Top Roller Arm Actuator, Panel Mount
HONEYWELL

BZV6-RNX1

Snap Acting/Limit Switch, SPDT, Momentary, 0.5A, 125VDC, 6.76mm, Screw Terminal, Steel Plunger Actuator, Panel Mount-threaded,
HONEYWELL

BZV60-B10

10V, 0.5W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE
NXP

BZV60-B11

11V, 0.5W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE
NXP

BZV60-B12

12V, 0.5W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE
NXP

BZV60-B13

13V, 0.5W, SILICON, UNIDIRECTIONAL VOLTAGE REGULATOR DIODE