2CPSA2A3B [HONEYWELL]

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount;
2CPSA2A3B
型号: 2CPSA2A3B
厂家: Honeywell    Honeywell
描述:

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount

开关
文件: 总15页 (文件大小:1911K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MICRO SWITCH Cable-Pull Safety Switches  
004785  
CPS Series  
Issue 4  
Datasheet  
FEATURES  
• Direct opening action of NC (Normally Closed) contacts  
• 2CPS: 2NO/2NC, 1NO/3NC, or 4NC contact configurations  
• 1CPS: 1NO/1NC, 2NO/2NC, 1NO/3NC, or 4NC contact  
configurations  
• Typical cable span of 76 m [250 ft] in an environment with  
a temperature change of 17 ꢀC [ 30 ꢀꢁ]. Longer spans  
are possible depending upon temperature change and  
installation  
• Choice of three actuator configurations (2CPS)  
• Removable contact block version available (2CPS)  
• J-hook turnbuckle included (2CPS)  
• Large wiring cavity with straight-through wiring  
• Models avaliable without broken cable, slack-cable detection  
• 24 Vdc or 120 Vac bright, multi-cluster high-intensity LED  
status indicator light available on 2CPS. Single LED on 1CPS  
• Gold-plated contacts are standard on 2CPS, available on  
1CPS  
DESCRIPTION  
Honeywell’s MICRO SWITCH CPS Series Cable-Pull Safety  
Switches provide a readily accessible emergency stop signal, a  
cost-effective means compared to using multiple emergency  
stop push-buttons. The CPS Series Cable Pull Safety Switch’s  
internal mechanism latches on both slackened cable (push)  
and pulled cable.  
• Electrostatic, epoxy-coated, die-cast zinc housing  
• Optional hardware packets available  
The 1CPS is intended for use in applications where the cable  
span is 76 m [250 ft] or shorter. It is an economical solution for  
shorter runs or zone protection typical to automated systems.  
The 2CPS Series is intended for use in very long cable runs of  
152 m [500 ft] or shorter, such as long conveyor lines found in  
warehouses.  
POTENTIAL INDUSTRIAL APPLICATIONS  
• Long conveyor systems found in warehouses and  
distribution centers  
• Conveyor systems with a high amount of vibration  
• Conveyor systems that experience wide temperature swings  
• Long conveyor systems where easy-through wiring, or highly  
visible trip status, is required  
• Perimeter guarding in hose-down conditions  
• Packaging equipment  
• Assembly lines  
A line in the midpoint of the cable tension window indicates  
proper cable tension, providing easy set-up. The direct opening  
switch contacts are held closed when the actuating cable is  
under proper tension and the reset knob is set to the RUN  
position. When the actuating cable is pulled, slackened, or  
broken, a cam positively opens the NC (Normally Closed)  
switch contacts. The snap-action operation causes the switch  
contacts to change state and mechanically latch almost  
simultaneously when the cable is pulled, slackened, or broken.  
The NC switch contacts remain open until the CPS is reset by  
properly tensioning the cable and manually rotating the reset  
knob.  
VALUE TO CUSTOMERS  
• Cost-effective means of providing an emergency stop signal  
compared to multiple emergency stop push buttons  
• Capability enhances productivity by minimizing nuisance  
stops due to variations in temperature, stretch of cable over  
time, or other application variables  
• Direct opening of normally closed contacts when cable is  
actuated  
When the direct opening switch contacts open, the auxiliary  
contacts also actuate (open contacts close). The auxiliary  
contacts are electrically isolated from the direct-opening  
switch contacts. These NO (Normally Open) contacts may be  
used for monitoring or signaling.  
PORTFOLIO  
The CPS Series is the largest switch in Honeywell’s MICRO  
SWITCH line of safety switches. ꢁor more details on the  
extensive line of Honeywell safety switches, click here.  
DIFFERENTIATION  
• Internal mechanism latches on both slackened cable (push)  
and pulled cable  
Sensing and Internet of Things  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 1. Specifications  
Characteristic  
Parameter  
Description  
cable-pull safety switches  
1NO/1NC direct acting  
2NO/2NC direct acting  
1NO/3NC direct acting  
4NC direct acting  
Switching options  
Sealing  
IP67, NEMA 1, 4, 12, 13  
Contacts  
silver, gold plated over silver  
Conduit/Connectors  
1/2 NPT, PG 13.5, 20 mm, Pꢁ 1/2; Brad Harrison 10-pin conductor  
ꢁorce to maintain actuation shaft 1CPS & 2CPS: 25 lb*  
Actuation shaft operating force  
Operating temperature  
Storage temperature  
1CPS & 2CPS: 40 lb*  
-40 ꢀC to 80 ꢀC [-40 ꢀꢁ to 176 ꢀꢁ]  
1CPS: -40 ꢀC to 85 ꢀC [-40 ꢀꢁ to 185 ꢀꢁ]  
Mechanical endurance  
Rated thermal current (Ith)  
1 million operations  
10 A  
Rated impulse withstand (Uimp  
Rated insulation voltage (Ui)  
Useable gold-plated current  
Pollution degree  
)
2500 V  
300 V  
1 mA to 50 mA, 60 Vdc max./125 Vdc max.  
3
Conditional short circuit current  
1000 A  
Short circuit protective device  
(type/maximum rating)  
Class J fuse (10 A/600 V)  
Shock  
15 g per IEC 68-2-27  
Vibration  
Approvals  
10 Hz to 500 Hz, 5 g per IEC 68-2-6  
UL, CSA, CE, SIL  
• UL Listed per ꢁile E37138 against UL508  
• CSA Certified per ꢁile 57323 against CSA C22.2 No. 14  
• CE mark: The CPS complies with Low Voltage Directive 2006/95/EC; Machinery Directive  
2006/42/EC only as the directives relate to the components being used in a safety function; EN  
60947-1; EN 60947-5-1; EN 60947-5-5  
Standards  
• SIL: MCTꢁ (Mechanical Life): >1,000,000 cycles with single-sided confidence limit of 100 %.  
MCTꢁ (Electrical Life): >25,000 cycles with single-sided confidence limit of 87.5 %.  
Highest SIL Capability: SIL3 (HꢁT:1), IEC 61508-2: 2010. Proof Test Interval: 1 Year  
* Incline measures, and not typical for manual trip  
Table 2. Electrical Ratings  
ac  
dc  
A300  
Ue  
AC15  
Ie  
Q300  
Ue  
DC13  
Ie  
Volts  
Amps  
Volts  
24  
Amps  
2.8  
6
3
120  
125  
250  
0.55  
0.27  
240  
Ith = 10 A  
2
sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Figure 1. 1CPS Product Nomenclature and Order Guide  
1CPS  
A
-N  
A
1
Conduit  
Without  
Broken  
Cable  
Indicator-Pilot  
Light Code  
Basic Switch  
Code  
Switch Type  
1NO/1NC direct acting  
1NO/1NC direct acting, gold contacts  
Switch 1: 1NO/1NC  
1CPS Series  
Single-Head  
Cable-Pull  
Switch 1: 1NO/1NC  
Switch 2: None  
1/2 NPT  
PG 13.5  
20 mm  
PF 1/2  
24 Vdc LED  
A
B
C
D
1
2
3
4
5
6
7
8
A
Detection  
Switch 2: None  
2NO/2NC direct acting  
Switch 1: 1NO/1NC  
Switch 2: 1NO/1NC  
1NO/3NC direct acting  
Switch 1: 1NO/1NC  
Switch 2: 2NC  
2NO/2NC direct acting, gold contacts  
Switch 1: 1NO/1NC  
Switch 2: 1NO/1NC  
1NO/3NC direct acting, gold contacts  
Switch 1: 1NO/1NC  
Switch 2: 2NC  
120 Vac LED  
B
Safety Switch  
4NC direct acting  
Switch 1: 2NC  
Switch 2: 2NC  
4NC direct acting, gold contacts  
Switch 1: 2NC  
Switch 2: 2NC  
NOTE: Not all combinations of model code are available.  
Please contact your Honeywell provider/representative for assistance.  
Figure 2. 2CPS Product Nomenclature and Order Guide  
2CPS  
A
1
A
A
1
Conduit  
Contact  
Mounting Code  
Indicator-Pilot  
Light Code  
Actuation  
Code  
Basic Switch  
Code  
2NO/2NC, direct acting  
Switch 1: 1NO/1NC  
Switch 2: 1NO/1NC  
Switch Type  
2CPS Series  
Dual-Head  
Cable-Pull  
Standard: contact  
block mounted  
to housing  
24 Vdc LED  
Maintained,  
both sides  
1/2 NPT  
PG 13.5  
20 mm  
PF 1/2  
A
B
C
D
A
cluster  
1
2
3
4
5
61  
A
B
D
1
Removeable:  
contact blocks  
with receptacles  
1NO/3NC, direct acting  
Switch 1: 1NO/1NC  
Switch 2: 2NC  
120 Vac LED  
cluster  
Maintained, left side  
No actuation, right side  
B
2
Safety Switch  
4NC, direct acting  
Switch 1: 2NC  
Switch 2: 2NC  
Maintained, right side  
No actuation, left side  
Maintained, both sides  
w/o broken cable detection  
Maintained, left side  
NOTE: Not all combinations of model code are available.  
Please contact your Honeywell provider/representative for assistance.  
No actuation, right side  
w/o broken cable detection  
Maintained, right side  
No actuation, left side  
w/o broken cable detection  
1 Not valid on 4NC switches  
Sensing and Internet of Things  
3
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 3. Circuitry Charts  
TEMPERATUREꢀSPAN DISTANCE APPLICATION  
Circuitry  
Chart  
INFORMATION  
Cable-pull switches featuring broken cable detection require  
1NO/1NC  
pre-tensioning in order to enable the RUN condition.  
The relative expansion or contraction of the steel actuating  
cable when the ambient temperature increases or decreases  
must be taken into account when pre-tensioning a cable pull  
switch.  
2NO/2NC  
The change in cable length with change in temperature can  
cause significant nuisance shut downs on longer runs.  
Install the system when the temperature is at the mid point of  
the extremes. If a warehouse has a low temperature of 15.6 ꢀC  
[60 ꢀꢁ]and a high of 32.2 ꢀC [90 ꢀꢁ], set up the system at the  
midpoint 23.9 ꢀC [75 ꢀꢁ].  
1NO/3NC  
4NC  
Use an endspring or another CPS at the opposite end of the  
cable span to double the temperature tolerance and to meet  
the requirements of EN 418.  
Figure 3. Total Temperature Variation vs. Cable Span  
Distance  
Table 4. 1CPS Contact Blocks  
 = grounding screw  
4
sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 5. 2CPS Contact Blocks  
Removable Contact Blocks with  
Contact Block Mounted to Housing  
Heavy-Duty Wiring Receptacles  
A = grounding screw  
A = grounding screw  
2NO/2NC  
2NO/2NC  
1NO/3NC  
1NO/3NC  
4NC  
Sensing and Internet of Things  
5
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 6. 1CPS With Broken Cable Detection Order Guide  
Bar Chart  
Catalog  
Listing  
Contact  
Material  
Conduit Switching ¢ Contact Closed | ¨ Contact Open  
Notes  
1CPSA1  
1CPSA1A  
1CPSA1B  
1CPSA5  
1CPSC1  
1CPSC1A  
1CPSC5  
1CPSA2  
1CPSA2A  
1CPSA2B  
1CPSA6  
1CPSA6A  
1CPSA6B  
1CPSC2  
1CPSC2A  
1CPSC2B  
1CPSC6  
1CPSC6A  
1CPSA3  
1CPSA3A  
1/2 in NPT 1NO/1NC  
1/2 in NPT 1NO/1NC  
silver alloy  
silver alloy  
silver alloy  
gold-plated  
silver alloy  
silver alloy  
gold-plated  
silver alloy  
silver alloy  
silver alloy  
gold-plated  
gold-plated  
gold-plated  
silver alloy  
silver alloy  
silver alloy  
gold-plated  
gold-plated  
silver alloy  
silver alloy  
ü
9,9  
9,9  
0
[0.39]  
[0.39]  
12,7  
[0.5]  
Left 21-22  
Switch 13-14  
7,9  
3,8  
3,8  
7,9  
12,7  
1/2 in NPT 1NO/1NC  
1/2 in NPT 1NO/1NC  
ü
[0.31] [0.15] [0.15] [0.31]  
[0.5]  
20 mm  
20 mm  
20 mm  
1NO/1NC  
1NO/1NC  
1NO/1NC  
Proper  
Slackened  
cable  
Pulled  
cable  
cable  
ü
ü
ü
ü
tension  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
ü
0
9,9  
[0.39]  
9,9  
[0.39]  
12,7  
[0.5]  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
[0.31] [0.15] [0.15] [0.31]  
Left 21-22  
Switch 13-14  
Right 21-22  
Switch 13-14  
20 mm  
20 mm  
20 mm  
20 mm  
20 mm  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
Proper  
cable  
Slackened  
cable  
Pulled  
cable  
tension  
ü
ü
ü
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
10-pin Brad  
Harrison con-  
nector; actuator  
to right  
1CPSA3A-ꢁ01 1/2 in NPT 1NO/3NC  
1CPSA3A-ꢁ02 1/2 in NPT 1NO/3NC  
silver alloy  
silver alloy  
0
9,9  
[0.39]  
9,9  
[0.39]  
12,7  
[0.5]  
Left 21-22  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
[0.31] [0.15] [0.15] [0.31]  
10-pin Brad  
Harrison con-  
nector; actuator  
to left  
Switch 13-14  
Right 11-12  
Switch 21-22  
ü
ü
Proper  
1CPSA3B  
1CPSA7  
1CPSC3  
1CPSC3A  
1CPSC7  
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
silver alloy  
gold-plated  
silver alloy  
silver alloy  
gold-plated  
ü
cable  
Slackened  
cable  
Pulled  
cable  
tension  
20 mm  
20 mm  
20 mm  
1NO/3NC  
1NO/3NC  
1NO/3NC  
1CPSA4  
1CPSA4B  
1CPSA8  
1CPSC4  
1/2 in NPT 4NC  
1/2 in NPT 4NC  
1/2 in NPT 4NC  
silver alloy  
silver alloy  
gold-plated  
silver alloy  
0
9,9  
9,9  
[0.39]  
[0.39]  
12,7  
[0.5]  
Left 11-12  
Switch 21-22  
Right 11-12  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
ü
[0.31] [0.15] [0.15] [0.31]  
Switch 21-22  
20 mm  
20 mm  
4NC  
4NC  
Proper  
cable  
Pulled  
cable  
Slackened  
cable  
1CPSC8  
gold-plated  
tension  
6
sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 7. 1CPS Without Broken Cable Detection Order Guide  
Bar Chart  
Catalog  
Listing  
Contact  
Material  
Conduit Switching ¢ Contact Closed | ¨ Contact Open  
Notes  
9,9  
[0.39]  
1CPSA1-N  
1/2 in NPT 1NO/1NC  
silver alloy  
silver alloy  
7,9  
[0.31]  
12,7  
[0.5]  
0
Left 21-22  
Switch 13-14  
1CPSA1A-N  
1/2 in NPT 1NO/1NC  
ü
Pulled  
1CPSA1B-N  
1CPSA2-N  
1/2 in NPT 1NO/1NC  
1/2 in NPT 2NO/2NC  
cable  
silver alloy  
silver alloy  
ü
ü
9,9  
[0.39]  
7,9  
12,7  
[0.5]  
0
[0.31]  
Left 21-22  
Switch 13-14  
Right 21-22  
1CPSA2B-N  
1/2 in NPT 2NO/2NC  
silver alloy  
Switch 13-14  
Pulled  
cable  
9,9  
[0.39]  
7,9  
[0.31]  
12,7  
[0.5]  
0
Left 11-12  
Switch 21-22  
Right 11-12  
1CPSA4B-N  
1/2 in NPT 4NC  
silver alloy  
ü
Switch 21-22  
Pulled  
cable  
Sensing and Internet of Things  
7
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide  
Bar Chart  
¢ Contact Closed  
¨ Contact Open  
Catalog Listing  
Notes  
2CPSA1A1  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Both  
Both  
24  
Vdcdc  
2CPSA1A1A  
10-pin Brad  
24 Vdc Harrison  
connector  
2CPSA1A1A-ꢁW 1/2 in NPT 2NO/2NC  
ü
ü
Both  
Both  
120  
Vac  
2CPSA1A1B  
1/2 in NPT 2NO/2NC  
2CPSA1A2  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Left only  
Left only  
2CPSA1A2A  
24 Vdc  
10-pin Brad  
24 Vdc Harrison  
connector  
2CPSA1A2A-ꢁW 1/2 in NPT 2NO/2NC  
ü
Left only  
120  
Vac  
2CPSA1A2B  
1/2 in NPT 2NO/2NC  
ü
Left only  
2CPSA1A3  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Right only  
2CPSA1A3A  
Right only 24 Vdc  
10-pin Brad  
Right only 24 Vdc Harrison  
connector  
2CPSA1A3A-ꢁW 1/2 in NPT 2NO/2NC  
ü
ü
0
9,9  
9,9  
[0.39]  
[0.39]  
12,7  
[0.5]  
Left 21-22  
Switch 13-14  
Right 21-22  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
[0.31] [0.15] [0.15] [0.31]  
120  
Right only  
Vac  
2CPSA1A3B  
1/2 in NPT 2NO/2NC  
2CPSA2A1  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Both  
Switch 13-14  
Proper  
2CPSA2A1A  
Both  
24 Vdc  
cable  
Slackened  
cable  
Pulled  
cable  
tension  
120  
Vac  
2CPSA2A1B  
1/2 in NPT 2NO/2NC  
ü
Both  
2CPSA2A2  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Left only  
Left only  
2CPSA2A2A  
24 Vdc  
120  
Vac  
2CPSA2A2B  
1/2 in NPT 2NO/2NC  
ü
Left only  
2CPSA2A3  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
Right only  
2CPSA2A3A  
Right only 24 Vdc  
120  
Right only  
Vac  
2CPSA2A3B  
1/2 in NPT 2NO/2NC  
ü
2CPSC1A1  
2CPSC1A1A  
2CPSC1A2  
2CPSC1A2A  
2CPSC1A3  
2CPSC1A3A  
2CPSC2A1A  
20 mm  
20 mm  
20 mm  
20 mm  
20 mm  
20 mm  
20 mm  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
2NO/2NC  
ü
ü
ü
ü
ü
ü
Both  
Both  
24 Vdc  
24 Vdc  
Left only  
Left only  
Right only  
Right only 24 Vdc  
Both 24 Vdc  
ü
8
sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide, continued  
Bar Chart  
¢ Contact Closed  
¨ Contact Open  
Catalog Listing  
2CPSA1B1  
Notes  
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
ü
ü
Both  
Both  
2CPSA1B1A  
24 Vdc  
10-pin Brad  
24 Vdc Harrison  
connector  
2CPSA1B1A-ꢁ01 1/2 in NPT 1NO/3NC  
ü
ü
Both  
Both  
120  
Vac  
2CPSA1B1B  
1/2 in NPT 1NO/3NC  
120  
Vac  
2CPSA1B2  
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
ü
ü
Left only  
Left only  
2CPSA1B2A  
24 Vdc  
0
9,9  
[0.39]  
9,9  
[0.39]  
10-pin Brad  
24 Vdc Harrison  
connector  
12,7  
[0.5]  
Left 21-22  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
2CPSA1B2A-ꢁ01 1/2 in NPT 1NO/3NC  
ü
Left only  
[0.31] [0.15] [0.15] [0.31]  
Switch 13-14  
Right 11-12  
Switch 21-22  
120  
Vac  
2CPSA1B2B  
1/2 in NPT 1NO/3NC  
ü
Left only  
Proper  
cable  
tension  
2CPSA1B3  
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
ü
ü
Right only  
Slackened  
cable  
Pulled  
cable  
2CPSA1B3A  
Right only 24 Vdc  
10-pin Brad  
Right only 24 Vdc Harrison  
connector  
2CPSA1B3A-ꢁ01 1/2 in NPT 1NO/3NC  
ü
ü
120  
Right only  
Vac  
2CPSA1B3B  
1/2 in NPT 1NO/3NC  
2CPSA2B1  
1/2 in NPT 1NO/3NC  
1/2 in NPT 1NO/3NC  
ü
ü
Both  
2CPSA2B1A  
Both  
24 Vdc  
120  
Vac  
2CPSA2B1B  
2CPSC1D1A  
1/2 in NPT 1NO/3NC  
ü
Both  
0
9,9  
[0.39]  
9,9  
[0.39]  
12,7  
[0.5]  
Left 11-12  
Switch 21-22  
Right 11-12  
7,9  
3,8  
3,8  
7,9  
12,7  
[0.5]  
[0.31] [0.15] [0.15] [0.31]  
20 mm  
4NC  
ü
Both  
24 Vdc  
Switch 21-22  
Proper  
cable  
Pulled  
cable  
Slackened  
cable  
tension  
Sensing and Internet of Things  
9
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 9. 2CPS Without Broken Cable Detection and With Silver Alloy Contacts Order Guide  
Bar Chart  
¢ Contact Closed  
Catalog Listing  
2CPSA1A4  
¨ Contact Open  
Notes  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
1/2 in NPT 2NO/2NC  
ü
ü
ü
ü
Both  
2CPSA1A4B  
2CPSA1A5B  
2CPSA1A6B  
2CPSA2A4A  
2CPSA2A4B  
Both  
120 Vac  
120 Vac  
9,9  
[0.39]  
7,9  
Left only  
12,7  
[0.5]  
0
[0.31]  
Left 21-22  
Switch 13-14  
Right 21-22  
Switch 13-14  
Right only 120 Vac  
ü
ü
Both  
Both  
24 Vdc  
120 Vac  
Pulled  
cable  
No turnbuck-  
les included  
2CPSC1A4-ꢁ02  
20 mm  
2NO/2NC  
ü
Both  
10 sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Figure 4. 1CPS Dimensional Drawing  
172,72 mm [6.8 in]  
152,4 mm [6.0 in]  
Indicator version only  
6,6 mm  
[0.26 in]  
81,28 mm [3.2 in]  
33,02 mm  
88,9 mm [1.3 in]  
[3.5 in]  
12,7 mm  
[0.5 in]  
99,1 mm  
[3.9 in]  
76,2 mm  
[3.0 in]  
4 X Ø 7,37 mm  
[4 X Ø 0.29 in]  
53,34 mm  
[2.1 in]  
117,25 mm [4.616 in]  
approx. at full travel  
56,8 mm  
[2.24 in]  
50,82 mm  
[2.001 in]  
3X 25,4 mm  
[3X 1.0 in]  
65,2 mm  
[2.57 in]  
25,4 mm  
[1.0 in]  
3X conduit thread  
4X mounting pad  
Sensing and Internet of Things 11  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Figure 5. 2CPS Dimensional Drawing  
40,39 mm  
[1.59 in]  
84,07 mm  
[3.31 in]  
66,8 mm  
[2.63 in]  
92,89 mm  
[3.66 in]  
323,85 mm [12.75 in] approx. at actuation  
152,4 mm [6.0 in]  
52,07 mm  
40,39 mm  
[1.59 in]  
[2.05 in]  
Manual reset button  
12,7 mm  
19,05 mm  
[0.75 in]  
2X 7,11 mm [0.28 in]  
[0.5 in]  
18,29 mm [0.72 in]  
34,93 mm [1.375 in]  
81,3 mm  
[3.2 in]  
2X 7,11 mm  
[0.28 in]  
2X 9,14 mm [0.36 in]  
2X mounting pad  
152,4 mm  
[6 in]  
104,78 mm [4.125 in]  
Indicator version only  
2X 31,75 mm [1.25 in]  
12,7 mm [0.5 in]  
3X conduit thread  
57,15 mm  
[2.25 in]  
2X mounting pad  
2X 6,9 mm [0.27 in]  
139,7 mm [5.50 in]  
3X 12,46 mm [0.845 in]  
12 sensing.honeywell.com  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Figure 6. 1CPS Application Information  
Figure 7. 2CPS Application Information  
Sensing and Internet of Things 13  
MICRO SWITCH Cable-Pull Safety Switches, CPS Series  
Table 10. Accessories/Hardware Packets  
Catalog Listing  
CLSZC1  
Accessory  
Cable - 7,6 m [25 ft] length  
Cable - 15,2 m [50 ft] length  
Cable - 30,5 m [100 ft] length  
Cable - 45,7 m [150 ft] length  
Cable - 61 m [200 ft] length  
Cable - 76,2 m [250 ft] length  
CLSZC2  
CLSZC3  
CLSZC4  
CLSZC5  
CLSZC7  
(2) Thimbles  
(2) Low-profile duplex cable clamps  
CLSZTC  
CLSZ1S  
CPSZ1E  
CPSZ1S  
(1) Draw-bar endspring  
M6 x 1 x 60 mm eyebolt  
(1) Draw-bar endspring  
(1) J-hook turnbuckle with lock nuts  
(2) Thimbles  
(2) Low-profile duplex cable clamps  
CPSZK1  
(16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers]  
European hardware packet  
(1) J-hook turnbuckle with lock nuts  
CPSZK2  
(2) Thimbles  
(2) Stainless steel cable clamps  
(16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers]  
CPSZTB  
J-hook turnbuckle with lock nuts (included with 2CPS)  
Multi-cluster LED accessory - 24 Vdc (conduit mount)  
Multi-cluster LED accessory - 120 Vac (conduit mount)  
Mounting bracket (to be used with 1CPS or 2CPS)  
CPSLED24  
CPSLED120  
CPS-BRACKET  
Figure 8. CPSLED Dimensional Drawing  
Figure 9. CPS-Bracket  
14 sensing.honeywell.com  
m WARNING  
ADDITIONAL MATERIALS  
RISK TO LIFE OR PROPERTY  
The following associated literature is available on the Honeywell  
web site at sensing.honeywell.com:  
Never use this product for an application involving serious  
risk to life or property without ensuring that the system as a  
whole has been designed to address the risks, and that this  
product is properly rated and installed for the intended use  
within the overall system.  
Product line guide  
Product part listing/nomenclature tree  
Product range guide  
Failure to comply with these instructions could result in  
death or serious injury.  
CPS troubleshooting guide  
Electromechanical safety switch product selection guide  
Application note: MICRO SWITCH switches in conveyor  
applications  
m WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship during the appli-  
cable warranty period. Honeywell’s standard product warranty  
applies unless agreed to otherwise by Honeywell in writing;  
please refer to your order acknowledgement or consult your  
local sales office for specific warranty details. If warranted  
goods are returned to Honeywell during the period of coverage,  
Honeywell will repair or replace, at its option, without charge  
those items that Honeywell, in its sole discretion, finds defec-  
tive. The foregoing is buyer’s sole remedy and is in lieu of all  
other warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
For more information  
While Honeywell may provide application assistance personally,  
through our literature and the Honeywell web site, it is buyer’s  
sole responsibility to determine the suitability of the product in  
the application.  
Honeywell Sensing and Internet of  
Things services its customers through a  
worldwide network of sales offices and  
distributors. ꢁor application assistance,  
current specifications, pricing or the  
nearest Authorized Distributor, visit  
sensing.honeywell.com or call:  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this writing.  
However, Honeywell assumes no responsibility for its use.  
Asia Pacific  
Europe  
+65 6355-2828  
+44 (0) 1698 481481  
+1-800-537-6945  
USA/Canada  
Honeywell Sensing and Internet of Things  
9680 Old Bailes Road  
ꢁort Mill, SC 29707  
004785-4-EN | 4 | 12/17  
© 2017 Honeywell International Inc. All rights reserved.  
www. honeywell.com  

相关型号:

2CPSA2A4A

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL

2CPSA2A4B

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL

2CPSA2A6A

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL

2CPSA2A6B

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL

2CPSA2B1

Safety Door Switch, 4PST, Momentary, 0.05A, 60VDC, Wire Terminal, Panel Mount
HONEYWELL

2CPSA2B1A

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount
HONEYWELL

2CPSA2B1B

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount
HONEYWELL

2CPSA2B2

Snap Acting/Limit Switch
HONEYWELL

2CPSA2B2B

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Connector Terminal, Panel Mount
HONEYWELL

2CPSA2B3

Snap Acting/Limit Switch
HONEYWELL

2CPSA2B4A

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL

2CPSA2B4B

Snap Acting/Limit Switch, 4PST, Momentary, 2.8A, 24VDC, Screw Terminal, Panel Mount
HONEYWELL