26PCFFH2G [HONEYWELL]
Peizoresistive Sensor, Gage, 0Psi Min, 100Psi Max, 0-100mV, Rectangular, Through Hole Mount;型号: | 26PCFFH2G |
厂家: | Honeywell |
描述: | Peizoresistive Sensor, Gage, 0Psi Min, 100Psi Max, 0-100mV, Rectangular, Through Hole Mount 传感器 换能器 |
文件: | 总19页 (文件大小:2841K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Miniature Low Pressure Sensors
26PC Series, Compensated/Unamplified
1 psi to 250 psi
Datasheet
Miniature Low Pressure Sensors
The 26PC Series Miniature Pressure Sensors are small, cost-effective devices intended for use with wet or dry media.
These sensors feature proven sensing technology that uses a specialized piezoresistive micromachined sensing element
to offer high performance, reliability, and accuracy. Each sensor contains four active piezoresistors that form a Wheatstone
bridge. When pressure is applied, the resistance changes and the sensor provides a milliVolt output signal that is
proportional to the input pressure.
The low power 26PC sensors are designed to accommodate pressures from 1 psi to 250 psi and have an operating
temperature range of -40 ºC to 85 ºC [-40 ºF to 185 ºF].
These sensors can accommodate a variety of wet and dry media that are compatible with polyphthalamide (PPA) plastics
and media seals specified in the Nomenclature and Order Guide (see Figure 2). The 26PC sensors are RoHS compliant.
They are designed and manufactured according to ISO 9001 standards.
What makes our sensors better?
26PCXXJ6G
• Wet/Wet capability (i.e., liquids on both ports)
•ꢀ Selectable seals available to match media used
26PCXXH6D
•ꢀ Higher pressure ranges for use in high pressure applications
•ꢀ Wide variety of pressure port types
•ꢀ Available in both SIP and DIP packages
26PCXXK2G
For all available configurations, see Table 4.
MINIATURE • WET/WET CApAbIlITy • SElECTAblE SEAlS
sensing.honeywell.com
2
Features
and Benefits
One sensor does the work of two!
TꢀUꢁ wꢁT/wꢁT DꢂffꢁꢀꢁꢃTꢂꢄꢅ ꢆꢁDꢂꢄ SꢁꢃSꢂꢃG
Provides liquid sensing in differential applications
wꢂDꢁ ꢇPꢁꢀꢄTꢂꢃG TꢁꢆPꢁꢀꢄTUꢀꢁ ꢀꢄꢃGꢁ ꢇf -40 ºC Tꢇ 85 ºC
[-40 ºf Tꢇ 185 ºf]
Allows use in a wide variety of applications
By matching pressure ranges to the application, we optimize
resolution and improve system accuracy.
VꢄꢀꢂꢁTy ꢇf PꢀꢁSSUꢀꢁ ꢀꢄꢃGꢁS wꢂTHꢂꢃ 1 PSꢂ Tꢇ 250 PSꢂ
Provides flexibility in customers’ pneumatic designs
ꢄbSꢇꢅUTꢁ, DꢂffꢁꢀꢁꢃTꢂꢄꢅ, ꢄꢃD GꢄGꢁ ꢆꢁꢄSUꢀꢁꢆꢁꢃT TyPꢁS
Allows customers to choose the sensor that fits their application
Gives customers greater system flexibility in their designs.
VꢄꢀꢂꢁTy ꢇf PꢀꢁSSUꢀꢁ PꢇꢀT TyPꢁS ꢄꢃD ꢅꢁꢄD TꢁꢀꢆꢂꢃꢄTꢂꢇꢃS
Provides application flexibility
ꢄꢅSꢇ ꢄVꢄꢂꢅꢄbꢅꢁ ꢂꢃ SꢆT ꢄꢃD fꢅꢇw-THꢀꢇUGH PꢄCKꢄGꢁ
STyꢅꢁS
Provides added design flexibility
sensing.honeywell.com
3
Potential Applications
ꢆꢁDꢂCꢄꢅ
ꢇXyGꢁꢃ CꢇꢃꢁꢃTꢀꢄTꢇꢀS
May be used to measure the sieve bed pressure to optimize system performance
DꢁꢃTꢄꢅ CHꢄꢂꢀS
May be used to control the pneumatic pressure in the various dental instruments
HꢁꢆꢇDꢂꢄꢅySꢂS
May be used to monitor the correct pressure to help ensure optimum blood
filtration
ꢂꢃDUSTꢀꢂꢄꢅ
wꢄTꢁꢀ CꢇꢃTꢀꢇꢅ VꢄꢅVꢁS
May be used to monitor the water consumption in homes and buildings
ꢂꢀꢀꢂGꢄTꢂꢇꢃ ꢁQUꢂPꢆꢁꢃT
May be used to control the water pressure and flow being delivered
fꢂꢅTꢁꢀ ꢆꢇꢃꢂTꢇꢀꢂꢃG
May be used to detect when the filters are clogged and need to be replaced
PꢀꢁSSUꢀꢁ VꢄꢅVꢁS
May be used to measure and control pressure in industrial processes
ꢄꢂꢀ CꢇꢆPꢀꢁSSꢇꢀS
May be used to control the pressure being delivered to the end user equipment
bꢀꢁꢄTHꢄꢅꢂzꢁꢀS
May be used to measure the exhalation pressure to ensure proper breath analysis
sensing.honeywell.com
4
26PC Series, Compensated/Unamplified
Taꢈle 1. ꢄꢈsolute ꢆaximum ꢀatings1
Characteristic
Supply voltage
Input resistance
Output resistance
Time response
ꢆin.
2.5
5.5
1.5
–
Tꢉp.
10
ꢆax.
16
Unit
Vdc
ꢃote
–
–
–
2
7.5
2.5
–
11.5
3
kOhm
kOhm
ms
1
1Absolute maximum ratings are the extreme limits the device will withstand without damage.
2Time required for the output to increase from 10% to 90% of span in response to a step change in input pressure from the specified min. to max.
operating pressure.
Taꢈle 2. Technical Speciꢊications
Characteristic
Parameter
Operating temperature range:
without EPDM seals
with EPDM seals
-40 °C to 85 °C [-40 °F to 185 °F]
-20 °C to 85 °C [-4 °F to 185 °F]
Compensated temperature range
0 °C to 50 °C [32 °F to 122 °F]
-55 °C to 100 °C [-67 °F to 212 °F]
315 °C [599 °F] max./10 s max.
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
Storage temperature range
Soldering terminal temperature/time
Vibration
Shock
Life
1 million cycles min.
sensing.honeywell.com
5
Miniature Low Pressure Sensors
Taꢈle 3. Perꢊormance Characteristics (Vcc =10.00 0.01 Vdc; Ta = 25 °C [77 °f])
0 psi to
1 psi
0 psi to
5 psi
0 psi to
15 psi
0 psi to
30 psi
0 psi to
100 psi
0 psi to
250 psi
Characteristic
Unit
ꢃote
Tꢉp.
ꢆax.
16.7
Tꢉp.
ꢆax.
50
Tꢉp.
ꢆax.
100
Tꢉp.
ꢆax.
100
Tꢉp.
ꢆax.
100
2.0
Tꢉp.
ꢆax.
Span
–
–
2
–
–
3
–
–
3
–
–
3
–
–
3
–
–
150 7
mV
mV
1
2
Null offset
0 1.5
0 1.5
0 1.5
0 1.5
0
0 2.0
Linearity (Best
Fit Straight Line,
P2>P1)
0.25
0.5
0.5
0.4
0.5
1.0
0.5
0.25
0.5
0.5
0.1
0.2
0.4
1.0
0.5
0.6
2.0
1.5
0.5
1.0
0.5
0.7
%span
mV
3
4
5
Null shift
(0 °C to 25 °C,
25 °C to 50 °C)
1.0
2.0
1.0
1.5
1.0
1.5
0.75
0.75
1.5
1.5
2.0
1.5
Span shift
(0 °C to 25 °C,
25 °C to 50 °C)
1.0
0.75
%span
Repeatability
and hysteresis
0.5
–
–
0.2
–
–
0.2
–
–
0.2
–
–
0.2
–
–
0.2
–
–
mV
psi
6
7
Overpressure
20
20
45
60
200
500
1Span is the algebraic difference between the output signal measured at the upper and lower limits of the operating pressure range, where
Port 2 (P2)>Port 1 (P1).
2The output signal obtained when zero pressure is applied to all available ports.
3The maximum deviation of product output from a straight line fitted to the output measured over the specified operating pressure range, calculated
according to BFSL. The straight line is fitted along a set of points that minimizes the sum of the square of the deviations of each of the points (“least-
squares” method).
4The maximum deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at a reference
temperature of 25 °C.
5The maximum deviation in span due to changes in temperature over the compensated temperature range, relative to full-scale span measured at a
reference temperature of 25 °C.
6Repeatability is the maximum difference between the output readings when the same pressure is applied consecutively, under the same operating
conditions, with pressure approaching from the same direction within the specified operating pressure range. Hysteresis is the maximum difference
between output readings when the same pressure is applied consecutively, under the same operating conditions, with pressure approaching from
opposite directions within the specified operating pressure range.
7Overpressure is the maximum pressure that may safely be applied to the product for it to remain in specification once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature range.
figure 1. Circuit Diagram
Sꢉmꢈol
Vcc
Description
supply
Output “A” increases as P2 pressure increases.
Output “B” deceases as P2 pressure increases.
OUTPUT A
GROUND
OUTPUT B
bridge positive output
ground
PIN 1
VCC
PIN 2
OUTPUT
A
PIN 4
OUTPUT
B
bridge negative output
PIN 3
GROUND
sensing.honeywell.com
6
26PC Series, Compensated/Unamplified
figure 2. ꢃomenclature and ꢇrder Guide1, 4
For example, a 26PCBEJ6G catalog listing defines a 26PC Series Miniature Low Pressure Sensor, Compensated/Unamplified,
5 psi pressure range, EPDM seal material, needle pressure port type, 1 x 4 SIP, 15,2 mm [0.60 in] long termination configuration, with
normal polarity output and gage pressure measurement type.
6G
26PC
B
E
J
Termination Configuration,
Output, Pressure
Product Series Pressure Range
Seal Material
fluorosilicone
F
Pressure Port Type
Straight
Measurement Type
26PC Series
Miniature Low
Pressure Sensors,
Compensated/
Unamplified
1 psi
A
A
1 x 4 SIP, 15,2 mm [0.60 in] long,
normal polarity, differential
6D
B
5 psi
E
EPDM
B
C
Barbed
1 x 4 SIP, 15,2 mm [0.60 in] long,
normal polarity, gage
6G
1G
15 psi
30 psi
neoprene2
Luer
C
D
F
N
1 x 4 SIP, 10,2 mm [0.40 in] long,
normal polarity, gage
Modular
D
H
I
M5 thread port
90° (opposite Pin 1)
Needle
100 psi
250 psi
2G 2 x 2 DIP, normal polarity, gage
G
J
90° (toward Pin 1)
K
M
1/4-28 thread
Manifold mount
Long barbed
S
T
1Every combination may not be possible. Contact customer service.
2Available in 1 psi, 5 psi and 15 psi pressure ranges only.
3Absolute pressure sensors require pressure port types A or D.
sensing.honeywell.com
7
Miniature Low Pressure Sensors
Taꢈle 4. ꢄll ꢄvailaꢈle Standard Conꢊigurations (See figure 2.)
Termination Conꢊiguration, ꢇutput, Pressure ꢆeasurement Tꢉpe
6D
6G
1G
2G
ꢄ
N/A
Straight
b
barꢈed
C
ꢅuer
D
N/A
ꢆodular
H
ꢆ5
Thread
ꢂ
90°
(ꢇpposite
Pin 1)
N/A
N/A
N/A
N/A
J
ꢃeedle
K
90°
(Toꢋard
Pin 1)
ꢆ
1/4-28
Thread
S
ꢆaniꢊold
ꢆount
T
ꢅong
barꢈed
N/A
sensing.honeywell.com
8
26PC Series, Compensated/Unamplified
figure 3. ꢆounting Dimensions (for ꢀeꢊerence ꢇnlꢉ: mm/[in].)
26PCXXꢄ6G
26PCXXꢄ6D
12,7
[0.5]
2X 6,4 DIA.
2X 1,9 DIA.
[0.07]
[0.25]
12,7
[0.5]
1,9 DIA.
[0.07]
8,0
[0.32]
8,0
[0.32]
2X 6,4 DIA.
[0.25]
4
3
2 1
6,4 DIA.
[0.25]
4
3
2 1
15,2
[0.60]
15,2
[0.60]
4X 1,0
4X 0,5
[0.02]
[0.04
]
4X 1,0
[0.04]
2X 2,5
4X 0,5
[0.02]
3X 2,5
[0.10]
2X 5,1 DIA.
[0.20]
[0.10]
2,5
2
PORT
3X 2,5
[0.10]
[0.10]
5,1 DIA.
[0.20]
PORT 2
21,7
[0.85]
21,7
[0.85]
2X 4,5
[0.18]
0,4
4,5
[0.02]
[0.18]
9,0
[0.35]
0,4
[0.02]
9,0
[0.35]
1,7
[0.07]
34,4
1,7
[1.35]
[0.07]
1
PORT
PORT 1
26PCXXꢄ2G
26PCXXb6D
12,7
[0.5]
8,0
[0.32]
4
3
2 1
12,7
[0.5]
1,9 DIA.
[0.07]
15,2
3
2
4
1
[0.60]
8,0
[0.32]
4X 1,0
[0.04]
6,4 DIA.
[0.25]
PORT 2
4X 0,5
[0.02]
5,1 DIA.
[0.20]
2,5
3X 2,5
[0.10]
3,2 DIA.
[0.13]
[0.10]
PORT 2
4,7 DIA.
[0.19]
8,9
21,7
[0.35]
[0.85]
20,4
[0.80]
5,6
3,6
[0.22]
[0.14]
27,8
4,1 DIA.
[0.16]
[1.10]
0,4
9,0
[0.02]
9,0
[0.35]
[0.35]
2,1
4,4
1,6
[0.06]
[0.17]
[0.08]
4X 1,0
33,1
4X 0,5
[0.02]
4X 0,4
[0.02]
2X 8
[0.31]
[1.30]
[0.04]
2X 5
[0.20]
6,4 DIA.
PORT 1
[0.25]
PORT 1
5,0 DIA.
[0.20]
sensing.honeywell.com
9
Miniature Low Pressure Sensors
figure 3. ꢆounting Dimensions (continued)
26PCXXb6G
26PCXXb1G
12,7
2,0 DIA.
[0.5]
[0.08]
12,7
[0.5]
2,0 DIA.
[0.08]
8,0
[0.32]
8,0
[0.32]
4
3
2 1
4
3
2 1
15,2
10,2
[0.60]
[0.40]
4X 1,0
[0.04]
4X 1,0
[0.04]
4X 0,5
[0.02]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
3X 2,5
2,5
[0.10]
[0.10]
3,2 DIA.
[0.13]
3,2 DIA.
[0.13]
PORT 2
4,7 DIA.
[0.19]
PORT 2
4,7 DIA.
[0.19]
20,4
[0.80]
5,6
3,6
20,4
[0.80]
5,6
3,6
[0.22]
[0.14]
[0.22]
[0.14]
4,1 DIA.
[0.16]
4,1 DIA.
[0.16]
0,4
0,4
9,0
[0.35]
[0.02]
[0.02]
9,0
[0.35]
1,6
[0.06]
1,6
[0.06]
PORT 1
PORT 1
26PCXXb2G
26PCXXC6D
12,7
[0.5]
8,0
[0.32]
4
3
2 1
12,7
[0.5]
2,0 DIA.
15,2
3
2
4
[0.08]
[0.60]
8,0
[0.32]
4X 1,0
4X 0,5
[0.02]
1
3,2 DIA.
[0.13]
[0.04]
PORT 2
2,5
4,7 DIA.
[0.19]
3X 2,5
4,6 DIA.
[0.18]
[0.10]
[0.10]
20,4
[0.80]
PORT 2
5,6
3,6
3,9 DIA.
[0.15]
[0.22]
[0.14]
9,7
26,5
[1.04]
[0.38]
31,3
[1.23]
9,0
[0.35]
0,4
2,0
[0.02]
[0.08]
9,0
[0.35]
4,4
1,7
[0.07]
[0.17]
4X 0,4
[0.02]
4X 0,5
[0.02]
4X 1,0
[0.04]
2X 8
2X 5
[0.31]
[0.20]
6,4 DIA.
[0.25]
PORT 1
PORT 1
5,0 DIA.
[0.20]
sensing.honeywell.com
10
26PC Series, Compensated/Unamplified
figure 3. ꢆounting Dimensions (continued)
26PCXXC6G
26PCXXC1G
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
1,2 DIA.
[0.05]
[0.32]
8,0
4
3
2
1
[0.32]
15,2
4
3
2
1
[0.60]
10,2
[0.40]
4X 1,0
4X 1,0
4X 0,5
[0.02]
[0.04]
4X 0,5
[0.02]
[0.04]
2,5
2,5
3,9 DIA.
[0.15]
3X 2,5
3X 2,5
[0.10]
3,9 DIA.
[0.15]
[0.10]
[0.10]
[0.10]
PORT 2
PORT 2
4,6 DIA.
[0.18]
4,6 DIA.
[0.18]
18,7
18,7
[0.74]
0,4
[0.74]
0,4
[0.02]
[0.02]
9,0
9,0
[0.35]
[0.35]
1,7
[0.07]
1,7
[0.07]
PORT 1
PORT 1
26PCXXC2G
26PCXXD6D
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
12,7
[0.5]
4
3
2
1
1,2 DIA.
[0.05]
3
2
4
1
15,2
8,0
[0.60]
[0.32]
3,9 DIA.
4X 1,0
4X 0,5
[0.02]
[0.15]
[0.04]
PORT 2
4,6 DIA.
2,5
[0.18]
3X 2,5
[0.10]
[0.10]
24,8
PORT 2
[0.98]
18,7
0,4
[0.74]
[0.02]
9,0
[0.35]
9,0
[0.35]
4,4
1,7
[0.07]
[0.17]
21,7
[0.85]
4X 0,4
4X 1,0
[0.04]
4X 0,5
[0.02]
[
]
0.02
6,4 DIA.
[0.25]
2X 8
PORT 1
2X 5
[0.31]
[0.20]
5,0 DIA.
[0.20]
PORT 1
sensing.honeywell.com
11
Miniature Low Pressure Sensors
figure 3. ꢆounting Dimensions (continued)
26PCXXD6G
26PCXXD2G
12,7
1,2 DIA.
[0.5]
[0.05]
8,0
12,7
[0.5]
[0.32]
3
2
4
1
1,2 DIA.
[0.05]
4
3 2 1
8,0
[0.32]
15,2
[0.60]
PORT 2
4X 1,0
[0.04]
4X 0,5
[0.02]
9,0
0,59
2,0
2,5
[0.35]
[15.1]
3X 2,5
[0.08]
[0.10]
[0.10]
PORT 2
0,4
4X 1,0
[0.04]
4X 0,5
[0.02]
[0.02]
4X 0,4
[0.02]
9,0
[0.35]
2X 5
2X 8
[0.20]
[0.31]
1,7
PORT 1
[0.07]
PORT 1
26PCXXH6D
26PCXXH6G
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
1,2 DIA.
8,0
[0.05]
[0.32]
8,0
4
3
2 1
[0.32]
15,2
4
3
2
1
[0.60]
15,2
[0.60]
4X 1,0
4X 0,5
[0.02]
[0.04]
2,5
4X 1,0
3X 2,5
[0.10]
4X 0,5
[0.02]
[0.10]
[0.04]
7,3 DIA
[0.29]
PORT 2
M5 X 0,8
2,5
3X 2,5
[0.10]
[0.10]
7,3 DIA.
[0.29]
1,1
PORT 2
[0.4]
3,6
[0.4]
M5 X 0,8
1,1
[0.4]
21,7
[0.85]
3,6
[0.4]
0,4
[0.02]
9,0
21,7
[0.85]
[0.35]
0,4
[0.02]
9,0
4,4
1,7
[0.07]
[0.35]
[0.17]
34,4
[1.35]
6,4 DIA.
[0.25]
1,7
[0.07]
5,0 DIA.
[0.20]
PORT 1
PORT 1
sensing.honeywell.com
12
26PC Series, Compensated/Unamplified
figure 3. ꢆounting Dimensions (continued)
26PCXXH1G
26PCXXH2G
12,7
[0.5]
12,7
[0.5]
1,2 DIA.
[0.05]
3
2
4
1
1,2 DIA.
[0.05]
8,0
8,0
[0.32]
[0.32]
4
3
2 1
7,3 DIA.
[0.29]
10,2
PORT 2
[0.40]
M5 X 0,8
4X 1,0
1,1
4X 0,5
[0.02]
[0.04]
[0.4]
27,8
2,5
3,6
[1.09]
[0.10]
3X 2,5
[0.10]
[0.4]
PORT 2
21,7
[0.85]
M5 X 0,8
1,1
9,0
[0.4]
[0.35]
3,6
[0.4]
21,7
[0.85]
0,4
4X 1,0
[0.04]
4X 0,5
4X 0,4
[0.02]
[0.02]
9,0
[0.02]
[0.35]
2X 5
2X 8
[0.20]
[0.31]
1,7
[0.07]
PORT 1
PORT 1
5,1 DIA.
[0.20]
26PCXXꢂ6D
26PCXXꢂ6G
5,1 DIA.
[0.20]
6,4 DIA.
[0.25]
6,4 DIA.
[0.25]
4,1
[0.16]
4,1
[0.16]
36,2
[1.43]
8,0
36,2
[0.32]
[1.43]
8,0
[0.32]
4
3
2
1
15,2
4
3
2 1
[0.60]
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
2,5
3X 2,5
4X 1,0
[0.04]
[0.10]
[0.10]
4X 0,5
[0.02]
PORT 2
7,0
2,9
1,6
2,5
3X 2,5
[0.28]
[0.11]
[0.06]
[0.10]
[0.10]
1,6
PORT 2
7,0
2,9
1,6
[0.06]
14,5
[0.57]
0,4
[0.28]
[0.11]
[0.06]
[0.02]
9,0
2,0 DIA.
[0.08]
[0.35]
1,6
[0.06]
14,5
[0.57]
0,4
27,2
[1.07]
1,7
[0.07]
[0.02]
9,0
2,0 DIA.
[0.08]
[0.35]
4,4
[0.17]
6,4 DIA.
1,7
[0.07]
[0.25]
PORT 1
5,0 DIA.
[0.20]
PORT 1
sensing.honeywell.com
13
Miniature Low Pressure Sensors
figure 3. ꢆounting Dimensions (continued)
12,7
0,6 DIA.
[0.02]
26PCXXJ6D
26PCXXJ6G
[0.5]
8,0
12,7
[0.5]
0,6 DIA.
[0.02]
[0.32]
4
3
2 1
8,0
[0.32]
15,2
[0.60]
4
3
2 1
15,2
[0.60]
4X 1,0
4X 0,5
[0.04]
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
1,9 DIA.
[0.07]
4X 1,0
4X 0,5
[0.04]
PORT 2
[0.02]
2,5
6,4 DIA.
3X 2,5
[0.10]
1,9 DIA.
[0.07]
[0.10]
[0.25]
PORT 2
22,1
[0.87]
6,4 DIA.
[0.25]
22,1
[0.87]
0,4
[0.02]
9,0
[0.35]
0,4
[0.02]
4,4
9,0
[0.35]
1,6
[0.06]
[0.17]
34,8
[1.37]
1,6
[0.06]
6,4 DIA.
[0.25]
PORT 1
5,0 DIA.
[0.20]
PORT 1
26PCXXJ2G
26PCXXK6D
8,0
[0.315]
21,0
[0.83]
12,7
[0.5]
4,1
[0.16]
15,2
[0.60]
3
2
4
1
0,6 DIA.
[0.02]
8,0
[0.32]
4X 1,0
4X 0,5
[0.02]
[0.04]
2,5
1,9 DIA.
[0.07]
3X 2,5
[0.10]
6,4 DIA.
[0.10]
PORT 2
[0.25]
7,0
2,9
1,6
6,4 DIA.
[0.25]
5,1 DIA.
[0.28]
[0.11]
[0.06]
[0.20]
PORT 2
22,1
[0.87]
28,2
1,6
[1.11]
[0.06]
14,5
0,4
[0.57]
[0.02]
9,0
2,0 DIA
[0.08]
[0.35]
9,0
[0.35]
27,2
[1.07]
1,7
[0.07]
4,4
[0.17]
6,4 DIA.
[0.25]
4X 1,0
[0.04]
4X 0,5
[0.02]
4X 0,4
[0.02]
2X 8
[0.31]
PORT 1
3 2 1
5,0 DIA.
[0.20]
2X 5
4
[0.20]
PORT 1
sensing.honeywell.com
14
26PC Series, Compensated/Unamplified
figure 3. ꢆounting Dimensions (continued)
26PCXXK6G
26PCXXK2G
12,7
[0.5]
8,0
8,0
[0.315]
[0.32]
21,0
[0.83]
4,1
4,1
[0.16]
[0.16]
21,0
[0.83]
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
7,0
2,9
1,6
[0.28]
[0.11]
[0.06]
2,5
3X 2,5
PORT 2
[0.10]
6,4 DIA.
[0.25]
[0.10]
1,6
7,0
2,9
1,6
[0.06]
14,5
[0.57]
5,1 DIA.
[0.20]
[0.28]
[0.11]
[0.06]
9,0
PORT 2
[0.35]
1,6
[0.06]
14,5
0,4
20,6
[0.81]
[0.57]
[0.02]
9,0
2,0 DIA.
[0.08]
[0.35]
4X 1,0
[0.04]
4X 0,4
[0.02]
2X 8
[0.31]
4X 0,5
[0.02]
1,7
2X 5
4
3
2 1
[0.07]
[0.20]
5,0 DIA.
[0.20]
PORT 1
6,4 DIA
[0.25]
PORT 1
2
1
4
3
12,7
[0.5]
26PCXꢆ6D
26PCXXꢆ6G
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
1, 2 DIA.
[0.05]
[0.32]
8,0
4
3
2 1
[0.32]
15,2
4
3
2
1
[0.60]
15,2
[0.60]
4X 1,0
4X 0,5
[0.04]
[0.02]
2,5
3X 2,5
4X 1,0
[0.10]
[0.10]
4X 0,5
[0.04]
[0.02]
PORT 2
¼-28 UNF
2,5
9,1 DIA.
[0.36]
3X 2,5
[0.10]
[0.10]
1,8
PORT2
¼-28UNF
9, 1 DIA.
[0.36]
[0.07]
3,6
[0.4]
1,8
3,2
7,1 DIA.
[0.30]
[0.07]
[0.13]
24,0
3,6
[0.4]
[0.94]
0,4
[0.02]
9,0
7, 1 DIA.
[0.30]
3,2
[0.35]
24,0
[0.13]
[0.94]
0,4
4,4
[0.02]
9,0
[0.35]
1,7
[0.07]
[0.17]
36,7
[1.44]
6,4 DIA.
[0.25]
1,7
[0.07]
PORT 1
5,0 DIA.
[0.20]
PORT1
sensing.honeywell.com
15
Miniature Low Pressure Sensors
figure 3. ꢆounting Dimensions (continued)
26PCXXꢆ1G
26PCXXꢆ2G
12,7
1,2 DIA.
[0.5]
[0.05]
12,7
[0.5]
8,0
[0.32]
3
2
4
1
1,2 DIA.
[0.05]
4
3 2 1
8,0
[0.32]
10,2
[0.40]
9,1 DIA.
[0.36]
4X 1,0
[0.04]
PORT 2
¼-28 UNF
4X 0,5
[0.02]
2,5
24,0
[0.94]
[0.10]
3X 2,5
[0.10]
1,8
[0.07]
3,6
PORT 2
[0.4]
M5 X 0,8
1,1
7,1 DIA.
[0.30]
3,2
[0.4]
[0.13]
3,6
[0.4]
9,0
[0.35]
21,7
[0.85]
0,4
[0.02]
9,0
[0.35]
4X 1,0
[0.04]
4X 0,5
[0.02]
4X 0,4
[
0.02]
1,7
[0.07]
2X 5
2X 8
[0.20]
[0.31]
PORT 1
PORT 1
26PCXXS6D
26PCXXS6G
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
1,2 DIA.
0.05]
[0.32]
[
8,0
[0.32]
6,3 DIA.
[0.25]
4
3
2 1
15,2
6,3 DIA.
[0.25]
4
3
2
1
[0.60]
15,2
[0.60]
4X 1,0
4X 0,5
[0.02]
[0.04]
2,5
4X 1,0
3X 2,5
[0.10]
4X 0,5
[0.02]
[0.04]
[0.10]
9,1 DIA.
[0.36]
PORT 2
2,5
[0.10]
3X 2,5
[0.10]
9,1 DIA.
[0.36]
PORT
2
1,3
13,9
[0.05]
0,4
[0.55]
[0.02]
9,0
1,3
[0.35]
13,9
[0.05]
0,4
[0.02]
[0.55]
9,0
[0.35]
4,4
1,7
[0.07]
[0.17]
26,54
[1.04]
1,7
[0.07]
6,4 DIA.
[0.25]
PORT 1
5,0 DIA.
[0.20]
PORT
1
sensing.honeywell.com
16
26PC Series, Compensated/Unamplified
figure 3. ꢆounting Dimensions (continued)
26PCXXS1G
26PCXXS2G
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
3
2
4
1
1,2 DIA.
[0.05]
[0.32]
8,0
6,3 DIA.
[0.25]
4
3
2 1
[0.32]
10,2
[0.40]
6,3 DIA.
[0.25]
PORT 2
9,1 DIA.
[0.36]
4X 1,0
[0.04]
4X 0,5
[0.02]
1,3
2,5
13,9
[0.55]
3X 2,5
9,1 DIA.
[0.36]
[0.05]
[0.10]
[0.10]
9,0
6,3 DIA.
[0.25]
PORT 2
[0.35]
1,3
5,1 DIA.
[0.20]
[
0.05]
13,9
[0.55]
0,4
4X 1,0
[0.04]
2X 5
[0.20]
PORT 1
4X 0,5
[0.02]
9,0
4X 0,4
[0.02]
[0.02]
[0.35]
2X 8
[0.31]
1,7
[0.07]
PORT 1
26PCXXT6D
26PCXXT6G
12,7
[0.5]
12,7
[0.5]
8,0
8,0
[0.32]
[0.32]
4
3 2 1
4
3
2 1
15,2
[0.60]
15,2
[0.60]
4X 1,0
4X 0,5
[0.02]
3X 2,5
[0.10]
[0.04]
4X 1,0
[0.04]
2,5
4X 0,5
[0.02]
[0.10]
3,2 DIA.
[0.13]
PORT 2
2,5
3X 2,5
[0.10]
4,7 DIA.
[0.10]
3,2 DIA.
[0.13]
[0.19]
PORT 2
1,8
4,7 DIA.
[0.19]
[0.07]
28,0
[1.10]
1,8
4,1 DIA.
[0.16]
[0.07]
28,0
[1.10]
11,2
[0.44]
4,1 DIA.
[0.16]
40,7
[1.60]
11,2
0,4
[0.44]
[0.02]
9,0
[0.35]
0,4
4,4
[0.02]
1,6
[0.06]
9,0
[0.35]
[0.17]
1,6
[0.06]
6,4 DIA.
[0.25]
PORT 1
5,0 DIA.
[0.20]
PORT 1
sensing.honeywell.com
17
Miniature Low Pressure Sensors
figure 3. ꢆounting Dimensions (continued)
26PCXXT2G
12,7
[0.5]
3
2
4
1
8,0
[0.32]
1,2 DIA.
[0.057]
3,2 DIA.
[0.13]
PORT 2
4,7 DIA.
[0.19]
1,8
[0.07]
28,0
[1.10]
4,1 DIA.
[0.16]
11,2
[0.44]
9,0
[0.35]
4X 1,0
[0.04]
4X 0,5
[0.02]
4X 0,4
[0.02]
2X 5
2X 8
[0.20]
[0.31]
PORT 1
sensing.honeywell.com
18
ꢄDDꢂTꢂꢇꢃꢄꢅ ꢂꢃfꢇꢀꢆꢄTꢂꢇꢃ
wꢄꢀꢃꢂꢃG
The following associated literature is available at sensing.honeywell.com:
PꢁꢀSꢇꢃꢄꢅ ꢂꢃJUꢀy
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀProductꢀLineꢀGuide
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
•ꢀProductꢀRangeꢀGuide
•ꢀProductꢀInstallationꢀInstructions
•ꢀApplication-SpecificꢀInformation
•ꢀTechnicalꢀNotes
failure to complꢉ ꢋith these instructions could result in
death or serious injurꢉ.
wꢄꢀꢃꢂꢃG
ꢆꢂSUSꢁ ꢇf DꢇCUꢆꢁꢃTꢄTꢂꢇꢃ
•ꢀ Theꢀinformationꢀpresentedꢀinꢀthisꢀproductꢀsheetꢀisꢀforꢀ
reference only. Do not use this document as a product
installation guide.
•ꢀ Completeꢀinstallation,ꢀoperation,ꢀandꢀmaintenanceꢀ
information is provided in the instructions supplied with each
product.
failure to complꢉ ꢋith these instructions could result in
death or serious injurꢉ.
wꢄꢀꢀꢄꢃTy/ꢀꢁꢆꢁDy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items it finds defective. The ꢊoregoing is ꢈuꢉer’s sole
remedꢉ and is in lieu oꢊ all other ꢋarranties, expressed or
implied, including those oꢊ merchantaꢈilitꢉ and ꢊitness ꢊor
a particular purpose. ꢂn no event shall Honeꢉꢋell ꢈe liaꢈle
ꢊor consequential, special, or indirect damages.
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
32307741-A-EN IL50
May 2015
© 2015 Honeywell International Inc. All rights reserved.
相关型号:
26PCFFM2G
Peizoresistive Sensor, Gage, 0Psi Min, 100Psi Max, 0-100mV, Rectangular, Through Hole Mount
HONEYWELL
©2020 ICPDF网 联系我们和版权申明