Universal input AC-DC Medical and ITE application open frame  
internal switching power supplies convection-cooled  
200-250 Watts dual output HICM250 series  
Features  
6x4 inch Compact size  
Very High Efficiency up to 90%  
200-250W Convection/300W Forced-cooled  
U-Bracket or Box format optional  
Medical and ITE application  
Class I construction  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
90-264VAC  
Efficiency  
Typical 90-92% (depending on model)  
90-110KHz (depending on model)  
IEC60601-1 and IEC60950-1  
LLC circuit  
47-63Hz  
Switching Frequency  
Dielectric Withstand  
Circuit Topology  
Transient Response  
Typical 2-2.45A at 115VAC  
Typical 1-1.2A at 230VAC  
Typical 18.6A rms at 230VAC  
Typical 0.97 at 230VAC  
B-S connector  
Inrush Current  
Power Factor  
Output voltage returns in less than  
0.01-0.2mS for a 25% load change  
Available  
(depending on model)  
Input Connector  
Power OK  
Earth Leakage Current Less than 0.15mA  
Remote ON/OFF  
Power Density  
Construction  
Available  
5.3-6.6W / Cubic Inch  
Output  
Output Connector  
Line Regulation  
Load Regulation  
Total Regulation  
Noise & Ripple  
Adjustability  
B-S connector  
U-Bracket and Box format optional  
Typical 0.1%  
Environmental  
Operating Temperature  
(Refer to the derating chart)  
Storage Temperature  
Cooling  
Typical ±1%  
-25°C to +70°C derate with  
derating  
Typical ±2%  
Typical 1% peak to peak  
Available at V1  
27-30mS min. at 230VAC  
-30°C to +85°C  
Convection-cooled: 200-250W  
Forced-cooled: 300W with 15CFM  
10-95% RH, non-condensing  
5-95% RH  
Hold-up Time  
Protection  
Over Voltage  
Over Load  
Operating Humidity  
Storage Humidity  
Safety/EMC  
Emissions (conducted)  
Harmonic Current  
Safety Standard  
Built-in (Latch)  
Typical set about 140-175% of  
rating output wattage  
Installed by NTC  
CISPR EN55011 & EN55032 Class B  
IEC61000-3-2  
(depending on model)  
Over Temperature  
IEC60601-1/IEC60950-1Class I  
Notes:  
(1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.  
(2) Load regulation is measured at 115VAC or 230VAC in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).  
(3) The power supply is considered a component installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.  
(4) Due to requests in market and advances in technology, specifications subject to change without notice.  
Version  
0 Edited on April 14 2017  
-1-  
Output voltage & current rating chart  
Single Output  
V1 @  
Stand-by Output  
Model No.  
(Model no. for example  
Typ.  
Max.  
(Forced-cooled)  
Min.  
Volt.  
Typ.  
Volt.  
Please refer to note 1 & 2)  
(Convection-cooled)  
HICM250-D120E-C1B  
HICM250-D120E-C1U  
HICM250-D190E-C1B  
HICM250-D190E-C1U  
HICM250-D240E-C1B  
HICM250-D240E-C1U  
HICM250-D560E-C1B  
0A  
0A  
0A  
0A  
0A  
0A  
0A  
0A  
16.5A  
12V  
12V  
19V  
19V  
24V  
24V  
56V  
56V  
24.6A  
24.6A  
15.5A  
15.5A  
12.3A  
12.3A  
5.3A  
1A  
1A  
1A  
1A  
1A  
1A  
1A  
1A  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
5V  
18.5A  
10.3A  
11.6A  
10.2A  
10.2A  
4.4A  
HICM250-D560E-C1U  
4.4A  
5.3A  
Symbol: “OVP” built-in “@” Adjustable  
Notes: (1) Please add suffix to model number to define type: add “-B” for enclosure (metal box) version, and “-U” for U-Bracket version.  
For example: HICM250-D120E-C1B is for Class I and Metal Box version; HICM250-D120E-C1U is for Class I and U-bracket version.  
(2) Other output voltages are available. Please contact sales for details.  
(3) 15CFM fan-cooling is required if the output wattage is 300Watt.  
Mechanical Dimensions (Note: All dimensions are in mm[inch])  
Derating Chart  
Pin assignment  
Assignment  
AC-Line  
Pin No.  
CNT1-L  
CNT1-N  
CNT1-G  
CNT2-3,4  
AC-Neutral  
AC-Ground  
V1  
DC COM  
V2  
CNT2-1,2, CNT4-2, CNT5-2  
CNT2-5  
CNT4-1  
CNT5-1  
Power OK  
NoteS:  
(1) 15 CFM fan cooling is required if total output power is 300W.  
(2) The 100% load is 250W at convection-cooled.  
Derate output power by 20% for Metal Box version at 12V & 19V.  
Derate output power by 10% for U-Bracket version at 12V & 19V.  
Remote ON/OFF  
Notes:  
Remote ON/OFF: CNT5-1 &CNT5-2 must be shorted to switch on the output.  
Version  
0 Edited on April 14 2017  
-2-  

相关型号:

HICM250-D240E-C1B

6x4 inch Compact size
HITRON

HICM250-D240E-C1U

6x4 inch Compact size
HITRON

HICM250-D560E-C1B

6x4 inch Compact size
HITRON

HICM250-D560E-C1U

6x4 inch Compact size
HITRON

HICM50G

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S033700

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S050700

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S120416

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S150340

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S240210

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S360140

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON

HICM50G-S480105

UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
HITRON