LF07WBP-3P 概述
Miniature Waterproof Shielded Connectors 圆形连接器
LF07WBP-3P 数据手册
通过下载LF07WBP-3P数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Miniature Waterproof Shielded Connectors
LF Series
(Example : LF07)
Mated dimensions
8.9 mm max. (3 pos.)
36.4
Receptacle
Plug
Fig. 1
■Features
Shielding Connection - Plug
1. Ease of shielded termination and
connector assembly
Built-in shield
connection spring
All components are self-aligning and do not require
complex assembly tooling. The shield of the cable is
connected with the metal housing of the connector
using simple shielding clamp, supplied with the
connector. (Fig. 2)
Cable shielding connection clamp
Cable
2. Water and dust protected
The LF series is a rugged, waterproof connector
series that is IP67 and IP68 rated in the mated
condition.
Fig. 2
IP67 : Left in water at a depth of 1 m for 30 minutes
IP68 : Left in water at a depth of 2 m for 14 days
Short turn bayonet lock
3. Simplified assembly procedure
Mating:
Insert the plug, and then turn the locking collar clockwise,
No use of screws makes wiring and mounting easier.
as indicated by the coupling direction marking.
4. Bayonet lock
2
Short turn bayonet lock assures secure vibration
resistant mating of the connectors. (Fig. 3)
1
Plug
Coupling direction marking
Receptacle
Un-mating:
Locking collar
5. Acquired safety standard
4 pos. is 10A and meets safety standards (TÜV)
Also 3- and 4-pos. have acquired the UL standard.
Turn the locking collar counter-clockwise
then pull off the plug.
6. High current rating capacity
1
No. of contacts
Current rating
2
3
5A max.
4
10A max.
2A max.
Coupling direction marking
Fig. 3
6, 12 and 20
10A max.
2A max.
11
In cases where the application will demand a high level of reliability, such as automotive,
please contact a company representative for further information.
1
2018.7
④
LF Series●Miniature Waterproof Shielded Connectors
Product Specifications
■
125V AC, 175V DC (3 pos.)
125V AC, 125V DC (4 pos.)
Voltage rating
30V AC, 42V DC (6 pos. , 12pos. , 20pos.)
125V AC, 125V DC (11 pos. A to D)
30V AC, 42V DC (11 pos. 1 to 7)
5A max. (3 pos.)
Ratings
10A max. (4 pos.)
Current rating
2A max. (6 pos. , 12pos. , 20pos.)
10A(11 pos. A to D), 2A(11 pos. 1 to 7)
Operating temperature range
Storage temperature range
–25ç to +85ç
–10ç to +60ç
Item
1.Contact resistance
Specifications
Conditions
15mø max. (3, 6, 12, 20 pos.)
5mø max. (4 pos.)
5mø max. (A to D), 15mø max. (1 to 7)(11 pos.)
1A DC
500V DC (3, 4 pos.)
2.Insulation resistance 1000Mø min.
100V DC (6, 12, 20 pos.)
500V DC (A to D), 100V DC (1 to 7)(11pos.)
1250V AC/1 minute (3, 4 pos.)
3.Withstanding voltage No flashover or insulation breakdown.
300V AC/1 minute (6, 12, 20 pos.)
1250V AC(A to D),300V AC(1 to 7) / 1 minute(11pos.)
10
55
10Hz /cycle, single amplitude of
→
→
4.Vibration
5.Shock
No electrical discontinuity for 10µs max.
No electrical discontinuity for 10µs max
0.75mm 5 minutes / cycle, three directions,
10 cycles for each direction.
Acceleration of 490m/s2, duration of 11ms, three
directions, three times for each direction.
30mø max. (3, 6, 12, 20 pos.)
10mø max. (4 pos.)
10mø max.(A to D), 30mø max.(1 to 7)(11pos.)
6.Durability6.
ꢀ(Mating/un-mating)
1000 cycles
Temperature : -55ç
Room temperature
Room temperature
+85ç
→ →
→
7.Temperature cycle
8.Humidity
Insulation resistance : 100Mø min.
Time : 30
2 to 3
30
2 to 3 (minutes) 5 cycles
→
→
→
Insulation resistance : 10Mø min. (at high humidity condition)
Insulation resistance : 100Mø min. (at dry condition)
96 hours at temperature of 40ç and humidity
of 90% to 95%.
Complete dust protection. No water penetration
when submerged for 48 hours at the depth of 1.8 meter.
9.Water / dust protection When mated with corresponding connector.
Materials / Finish
■
Components
Body / back shell
Insulator
Material
Finish / Color
Nickel plated
Black
Remarks
––––––––––
UL94V-0
Zinc alloy
PPS
Copper alloy
Chloroprene rubber
PPS
Contacts
Selective Gold plated
––––––––––
––––––––––
UL94V-0
Packing
Black
Tightening collar
Brown
Product Number Structure
■
Refer to the chart below when determining the product specifications from the product number.
Please select from the product numbers listed in this catalog when placing orders.
LF 07 W B P
6 S (**)
*-
-
❸
❶
❷
❹
❺
❻
❼
❽
Series name
Shell size
: LF
1
2
6
No. of contacts
: 3, 4, 6, 11, 12, 20
P: Male contact
07
7 Contact type
10
13
S: Female contact
8 Other specifications :
Waterproof
Lock Mechanism B : Bayonet lock
Connector type
W : Waterproof type
3
4
5
A two-digit character is added to
indicate other specifications as needed.
P : Plug
R : Receptacle
J
: Jack
(* : Form change zoning symbols in an identical class)
2
LF Series●Miniature Waterproof Shielded Connectors
Plugs
■
B
(Representative example.)
Unit : mm
Part No.
HRS No.
No. of contacts ØA
3
B
ØC Weight
LF07WBP-3S(31)
LF07WBP-3P(31)
LF07WBP-6S(31)
LF07WBP-6P(31)
LF10WBP-4S(31)
LF10WBP-4P(31)
LF10WBP-12S(31) 136-0007-8 31
LF10WBP-12P(31) 136-0008-0 31
LF13WBP-20S
LF13WBP-20P
LF13WBP-11S
LF13WBP-11P
136-0003-7 31
136-0004-0 31
136-0001-1 31
136-0002-4 31
136-0005-2 31
136-0006-5 31
12.3 35.8
14.8 41.8
17.9 51.9
5
11g
6
4
17g
16g
7.3
8.7
12
20
11
136-0009-3
136-0010-2
136-0011-5
136-0012-8
29g
●
Lock ease type
B
(Representative example.)
Unit : mm
Part No.
HRS No.
No. of contacts ØA
B
ØC Weight
LF07WBPD-6S(31)
LF10WBPD-4S(31)
LF10WBPD-4P(31)
LF10WBPD-12S(31) 136-0015-6 31
LF10WBPD-12P(31) 136-0018-4 31
136-0020-6 31
136-0014-3 31
136-0017-1 31
6
14.3 35.8
5
12g
19g
4
16.8 41.8
7.3
12
3
LF Series●Miniature Waterproof Shielded Connectors
■Receptacles
●
Front panel mount type・Solder Type
C
D
E
F(HEX)
(Representative example.)
Unit : mm
Part No.
HRS No.
No. of contacts ØA
ØB
13
C
D
E
F
Weight
LF07WBR-3P
LF07WBR-3S
LF07WBR-6P
LF07WBR-6S
LF10WBR-4P
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF13WBR-20P
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
136-1003-2
136-1004-5
136-1001-7
136-1002-0
136-1005-8
136-1006-0
136-1007-3
136-1008-6
136-1009-9
136-1010-8
136-1011-0
136-1012-3
3
16.55
10.3
7.65 1M9∞0.75 11
7.75 M11∞0.75 13
7.75 M14∞0.75 17
4g
15.05
15.25
6
4
19.05
17.25
17.25
19.05
6g
12.8 15.3
15.9 18.3
5g
6g
9g
10g
9g
10g
12
20
11
●
Front panel mount type・Through hole Type
C
D
E
F(HEX)
(Representative example.)
Unit : mm
Weight
9g
Part No.
LF13WBR-20SD
HRS No.
No. of contacts ØA
20
ØB
C
D
E
F
136-1017-7
15.9 18.3 17.5 7.75 M14∞0.75 17
4
LF Series●Miniature Waterproof Shielded Connectors
■Receptacles
●
Rear panel mount type・Solder Type
D(HEX)
C
E
(Representative example.)
Unit : mm
Part No.
No. of contacts ØA
4
ØB
C
19.05
D
E
Weight
HRS No.
LF10WBRB-4P
LF10WBRB-12P
LF10WBRB-12S
LF13WBRB-20S
LF13WBRB-11S
136-1118-4
136-1013-6
136-1014-9
136-1018-0
136-1019-2
12.8
18.3
17 M14∞0.75 10g
12
17.25
20
15.9
11
21.5 19.25 20 M17∞0.75 16g
●
Rear panel mount type・ Through hole Type
C
D(HEX)
E
(Representative example.)
Unit : mm
Part No.
LF10WBRB-12PD
LF10WBRB-12SD
No. of contacts ØA
12 12.8
ØB
C
D
E
Weight
HRS No.
136-1015-1
136-1016-4
18.3 17.5
17 M14∞0.75 9g
■Jacks
C
(Representative example.)
Unit : mm
Part No.
No. of contacts ØA
3
ØB
C
ØD Weight
HRS No.
LF07WBJ-3P
LF07WBJ-3S
LF07WBJ-6P
LF07WBJ-6S
LF10WBJ-4P
LF10WBJ-4S
LF10WBJ-12P
LF10WBJ-12S
LF13WBJ-20P
LF13WBJ-20S
LF13WBJ-11P
LF13WBJ-11S
136-2003-8
136-2004-0
136-2001-2
136-2002-5
136-2005-3
136-2006-6
136-2007-9
136-2008-1
136-2009-4
136-2010-3
136-2011-6
136-2012-9
10.3 11.5 36.3
12.8 13.8 42.4
15.9 16.9 52.4
5
11g
16g
6
4
7.3
8.7
12
20
11
29g
30g
29g
30g
5
LF Series●Miniature Waterproof Shielded Connectors
■CAP
●
For Receptacles
B
(Representative example.)
Unit : mm
Part No.
Applicable connector
LF07WBR-6P
ØA
B
Weight
HRS No.
LF07WBR-6S
LF07WBR-C
136-3008-7
12.3
4g
LF07WBR-3P
LF07WBR-3S
LF10WBR-4P
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF10WBRB-4P
LF10WBRB-12P
LF10WBRB-12S
LF10WBRB-12PD
LF10WBRB-12SD
LF13WBR-20P
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
LF13WBR-20SD
LF13WBRB-20S
LF13WBRB-11S
LF10WBR-C
14.8
5g
136-3001-8
8.8
LF13WBR-C
17.9
7g
136-3003-3
6
LF Series●Miniature Waterproof Shielded Connectors
BApplicable tools
Unit : mm
Description
Part No.
HRS No. LF series Applicable cable dia.
HR10A-TC-02 150-0041-2
LF-TC-01 150-0234-6
5 (Note)
7.3 · 8.7
Manual cable
clamp crimp
(Representative example.)
Note : Applicable cable dia. is only 5mm for LF series.
BSolder termination fixture
(Representative example.)
(Representative example.)
Part No.
HRS No.
Applicable connectors
LF07BP-T01
LF07BJ-T01
LF10BP-T01
LF10BJ-T01
LF13BP-T01
LF13BJ-T01
150-0232-0
150-0233-3
150-0235-9
150-0236-1
150-0237-4
150-0238-7
LF07WBP-**
LF07WBJ-**
LF10WBP-**
LF10WBJ-**
LF13WBP-**
LF13WBJ-**
Note : It is applicable regard less of given
alphabets or Numbers shown at *.
Unit : mm
BPanel Cutout
Alignment guide
Shell size
B
Weight
0.7 to 2
A
LF07WBR-**
LF10WBR-**
LF13WBR-**
LF10WBRB-**
LF13WBRB-**
Ø9.05
Ø11.05
8.1
10.2
Ø14.05
13.1
B+0.05
0
Ø17.05 16.1
0.7 to 4.8
BContact position arrangement and specifications
Shell size
LF10
LF13
LF07
1
8
1
9
B
C
2
3
4
5
1
3
2
6
4
8
10
4
3
1
2
6
7
9 10
3
1
A
1
D
4
Contact arrangement
5
2
11 12 13 14 15
16 17 18 19
20
7
12 11
5
3
2
2
3
6
4
5
6
7
No. of contacts
3
6
4
12
11
20
4
7
Withstanding voltage
1250V AC
5A
300V AC
2A
1250V AC
10A
300V AC
2A
AC300V
AC1250V AC300V
4
10A
7
2A
Current rating
Insulation resistance
Contact resistance
2A
1000Mø
4
5mø
4
7
15mø
7
5mø
15mø
15mø
15mø
Solder pot inner diameter
1.7mm
0.8mm
0.8mm
1.15mm
0.8mm
Ø
Ø
0.8
1.7
Note 1 : The contact configuration as viewed from the female contact connector mating side.
Note 2 : The symbol indicates polarizing key position.
▼
Note 3 : Withstanding voltages are test voltage values.
7
LF Series●Miniature Waterproof Shielded Connectors
□Termination and Assembly Instructions
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.
Operation
Illustration
No.
Plug disassembly
Solder termination fixture
1
1
Plug
Insert the plug into securely held solder
termination fixture as shown.
1
Fixture Part No.
Applicable connector
LF07BP-T01 LF07WBP-6S,6P,3S,3P
LF10BP-T01 LF10WBP-4S,4P,12S,12P
LF13BP-T01 LF13WBP-20S,20P,11S,11P
Locking collar
Insertion direction
Loosen the backshell turning it counter
clockwise and remove it from the body/
insulator assembly.
2
Body / insulator assembly
Backshell
2
1
Note
Note Vice fixed ban
Vice
When removing, assembling and wiring, be
sure to use a solder termination fixture.
Directly fixing the locking collar in place with
a vice etc.. could lead to damage,
A
Retaining ring
A Detail view
Vice
deformation or lacuna of retaining ring.
Jack Disassembly
Solder termination fixture
Jack
Insert the jack into the securely held solder
termination fixture as shown.
1
Fixture Part No.
Applicable connector
LF07BJ-T01 LF07WBJ-6S,6P,3S,3P
LF10BJ-T01 LF10WBJ-4S,4P,12S,12P
LF13BJ-T01 LF13WBJ-20S,20P,11S,11P
Insertion direction
Loosen the backshell turning it
counterclockwise.
2
Body / insulator assembly
Backshell
2
Note
When removing, assembling and wiring, be
sure to use a solder termination fixture.
Directly fixing the body in place with a vice
etc.. could lead to damage or deformation.
Note Vice fixed ban
Vice
Vice
Backshell
Connector Assembly
1
2
Apply a coating of Loctite 7649
1
(Manufactured by Henkel Japan, Ltd,) primer
to the threaded sections of the backshell and
the tightening collar. Completely dry the
coated surfaces.
Threaded section
Threaded section
Notes
(1)
(2)
(3)
Drying time at room temperature is
approximately 30 to 70 seconds.
Ensure sufficient ventilation of the area at
time of drying.
Take necessary steps to protect the coated
surfaces from contamination.
Tightening collar
Strain relief collar
Backshell
Thread the tightening collar, strain relief collar,
seal bushing and the backshell over the cable
as illustrated.
2
Tightening collar
2
Note
Threading the components may not be
possible after the cable-end finishing process.
Gasket
Cable
Cable preparation end
8
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
Stripping dimensions
No.
Cable preparation
Strip the cable’s outer jacket to the dimensions
illustrated in the table 1.
Notes
1
3
1
A
Cable outer jacket
Table 1. Stripping Dimensions
No. of Conductors
3
A mm
Exercise caution not to damage the shielding
mesh.
Any damage to the cable’s outer jacket may
affect the waterproof performance of the
assembled connector.
(1)
8 to 9
6
4
12
13 to 14
14 to 15
22 to 23 (No.A to D)
23 to 24 (No.1 to 7)
23 to 24
(2)
Shielding mesh
11
20
Cable outer jacket
Shielding mesh
2
Fold back the shielding mesh over the cable’s
outer jacket assuring that it is uniform on its
diameter.
Wires
2
3
Shielding mesh
(Folded back)
4 to 5mm
Wires
Cable outer jacket
Stripping dimensions
Cable outer jacket
Strip the wires to the dimensions illustrated in
the Table 2.
Note
3
Table 2. Stripping Dimensions
Wires
B
No. of Conductors
3
B mm
2.5 0.5
When stripping the wires exercise caution not
to damage it’s insulation, folded over
shielding mesh or cable’s outer jacket.
It may cause deffects in insulation,
2
3
2
0.5
0.5
0.5
6
4
12
3
2
0.5 (No.A to D)
0.5 (No.1 to 7)
11
20
conduction, and waterproof performance.
Conductors
2
0.5
Soldering
4
Soldering conditions
1
Soldering iron tip temperature: 350 10ꢀ
Soldering time: within 5 sec.
Notes
Assure that the solder compound is
(1)
sufficiently melted on the soldering iron tip.
When applying, make sure that the solder will
flow correctly at all the contact surfaces
between the conductor and the contact.
(2)
– 1 6, 12, 11(No.1 to 7), 20 Conductors
2
(1)
C
Wire
– 1
2
Heat shrink tubing Dimensions
Table 3
Place a heat-shrink tubing (inside diameter of
1.1 mm min.) over every other wire.
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as shown.
After soldering, slide the heat shrink tubing
over the soldered joint and shrink it. The
tubing should touch the insulator as shown.
Insulator
Contact
No. of
No. of contacts
C mm
Conductors
6
1 to 6
1 to 9
10 to 12
1 to 4
4
4
6
6
4
4
6
(2)
(3)
12
Heat-shrink tubing
11
20
5 to 7
1 to 5,16 to 20
6 to 15
Insulator
Insulator wall
– 2 3, 4, 11(No.A to D) Conductors
2
– 2
2
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as illustrated.
(1)
Insulator
Wire insulation
Contact
Contact
When soldering, to maintain the insulation
between adjacent contacts. Make sure that
the wire’s insulation remains below the edge
of the insulator’s wall 0.5 mm min., as
illustrated.
(2)
Insulator wall
Wire insulation
0.5 mm min.
Solder
9
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
3 After the soldering, keep a distance of D
between the contact end and the cable’s
outer jacket as illustrated.
Cable outer jacket
3
D
4
Table 4. Wire Dimensions
No. of Conductors D mm
Note
3
6 to 7
The distance of D is required in order to
assure correct assembly of the backshell.
6
4
10 to 11
13 to 14
Shielding mesh
(Folded back)
12
11
20
18 to 19
Solder termination fixture
Crimping of the Shielding Clamp
5
1
2
After completion of the soldering operations
Body / insulator assembly
Soldered joints
1
carefully remove (holding on the locking collar)
the body/insulator assembly from the solder
termination fixture.
Note
Exercise caution not to damage or deform the
solder joints.
2
Wrap the folded over shielding mesh with 5 to
6mm wide copper tape to assure that it will
not become loose.
Cable outer jacket
Copper tape
Cable outer jacket
Wires
Apply the copper tape so that the shielding
mesh does not protrude from under it.
Note
After wrapping the copper tape, the tape
should overlap itself by 2mm max.
Shielding mesh
5 to 6mm
Copper tape
Insert the “U” shaped shielding clamp over the
copper tape as shown on the illustration.
It is critical that the overlap of the copper tape
is located inside the shielding clamp as shown
on the illustration.
3
3
Cable outer jacket
1 0.5mm
Copper tape
Ground clamp
Copper tape
Cable outer jacket
Note
When the end of the copper tape wrapping is
positioned at the open side of the ground
fitting, the end portion of the copper tape
wrapping will no longer be covered by the
ground fitting when the ground fitting is
crimped.
Wires
Shielding clamp
Shielding mesh
Overlap of the copper tape
4
Using commercially available pliers bend the
open ends of the shielding clamp as illustrated,
assuring that it stays in place. The dimension
of E. between opposing edges of the shielding
clamp is necessary to assure correct final
crimp.
4
Commercially
available pliers
E
Table 5
Shell size
LF07
E
5mm max.
LF10
7mm max.
Shielding clamp
LF13
Overlap of the copper tape
10
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
Forming cavity
No.
Both sides of the shielding clamp must be
Crimping tool
5
5
5
placed in the forming cavity of the tool
(as shown on the illustration) and crimped
over the cable by closing the tool completely.
Shielding clamp
diameter
Applicable
cable
Crimping tool Forming cavity
after crimping
diameter
5.3mm to
5.3
HR10A-TC-02
7.0
5mm
–––
5.5mm
–––
7.9mm to
8.1mm
7.9
LF-TC-01
7.3mm
8.7mm
9.1mm to
9.1
9.3mm
Connector Assembly
1
2
Locktite area
Wiring side 1 to 2 threaded portion
,
Place the body/insulator assembly in the
applicable solder termination fixture.
1
6
For plug assembly
Applicable connector
LF07WBP-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
Fixture Part No.
LF07BP-T01
LF10BP-T01
LF13BP-T01
For jack assembly
Fixture Part No.
LF07BJ-T01
Body/insulator assembly
Threaded section
Applicable connector
LF07WBJ-6S,6P,3S,3P
LF10WBJ-4S,4P,12S,12P
LF13WBJ-20S,20P,11S,11P
LF10BJ-T01
Backshell
LF13BJ-T01
Coat the thread section of the body/insulator
assembly with Loctite 263 compound
(manufactured by Henkel Japan, Ltd.) or
equivalent, tightening it with a torque
specified in the table 6.
2
Notes
Wrench width : D
(1)
The applied loctite should not protrude out further
than the wiring side 1 to 2 threaded section. If it
does, it may affect waterproof performance and
locking. Please remove any protruding loctite
with a cloth or cotton swab. etc.
It is critical that the cable itself will not turn or
twist during this operation.
It may cause breakage at the soldered area.
Table 6 (Recommend tightening torgue)
Shell size Tightening torque Wrench width
·
·
1N m to 1.5N m
10mm
13mm
16mm
LF07
LF10
LF13
(2)
·
·
1N m to 1.5N m
·
·
1.5N m to 2N m
3
4
Slide forward the gasket and insert it in
the backshell until fully seated.
3
4
,
Gasket
Slide forward the strain relief collar and insert
it in the backshell, making sure that the
opposing protrusions fit inside the
corresponding grooves, as shown on the
illustration.
Strain relief collar
Note
Protrusion
Tightening collar
Groove
It is critical that the protrusions are inside the
corresponding grooves.
It may cause breakage, when a tightening collar is assembled.
5
5 Verify that the Locktite 7649 primer
(or equivalent) on the threaded sections of the
backshell and tightening collar are dry.
Apply the Locktite 263 compound to the
tightening collar’s threaded section and attach
it to the backshell.
Threaded section
Tightening collar
11
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
Remove the connector from the solder
termination fixture, holding it by the locking
collar. Do not pull on the cable.
It may cause breakage.
6
6
6
Tightening collar
Wrench width
Recommended tightening torgue
Shell size Tightening torque Wrench width
·
·
0.8N m to 1N m
10mm
14mm
16mm
LF07
LF10
LF13
·
·
0.7N m to 1N m
·
·
1 N m to 1.5 N m
Confirmation of Waterproof Performance
After connector assembly procedure is completed,
compress air in to the connector from the mating
side under 17.6 kPa for 30 seconds check that no
air leaks out of the connector.
7
□Cable Specifications (Reference)
No. of contact
4 pos.
6 pos.
12 pos.
20 pos.
Ø0.16
11 pos.
Ø0.26 Ø0.16
3 pos.
Material
Tin plated soft copper wire
Ø0.16
Size (mm)
Ø0.26
Ø0.16
Ø0.18
Construction
Size (AWG)
Sectional area
Diameter (mm)
Diameter (mm)
Thickness (mm)
Material
20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia.
20 /Ø0.18 mm dia.
20 AWG
0.5
16 AWG
1.25
26 AWG
0.14
26 AWG
0.14
26 AWG
0.14
16 AWG 26 AWG
1.25
Ø1.5
0.14
Ø1.5
Ø0.48
Ø0.48
Ø0.48
Ø0.48
Ø0.98
Ø2.1 (Standard)
0.3
Ø0.88 (Standard) Ø0.9 (Standard)
Ø0.9 (Standard)
0.21
Ø2.1 (Standard) Ø0.95 (Standard)
Ø1.5 (Standard)
0.26
0.2
0.21
Tin plated soft copper wire
80% or more
0.3
0.24
Density
80% or more
Ø5.5
85%
Ø3.4
80% or more
Ø5.1
80% or more
Ø6.7
85%
Ø3.6
Diameter (mm)
Diameter (mm)
Ø4.2
Ø7.3 0.2
Ø5 0.2
Ø7.3 0.2
Ø8.7 0.2
Ø8.7 0.2
Ø5 0.2
Remarks : The cable satisfies required specifications for UL specification.
Notes
: The cable pull and twisting strength, waterproof tightness and other characteristics may differ, depending on the cable structure,
please confirm before the use.
®
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
+
+
TEL: 81-45-620-3526 Fax: 81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 07/2018. Contents are subject to change without notice for the purpose of improvements.
12
LF07WBP-3P 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
LF07WBP-3P(31) | HRS | 连接器类型:插头;安全规格:UL;传输规格:CAT5e;额定电流:5.0 A;(AC)额定电压:AC 125.0 V;(DC)额定电压:DC 175.0 V;PIN数:3;壳体尺寸 (mm):7 | 获取价格 | |
LF07WBP-3S | HRS | Circular Connector, 3 Contact(s), Zinc Alloy, Male, Crimp Terminal, Plug, | 获取价格 | |
LF07WBP-3S(31) | HRS | Circular Connector, | 获取价格 | |
LF07WBP-6P | HRS | Miniature Waterproof Shielded Connectors | 获取价格 | |
LF07WBP-6P(31) | HRS | Circular Connector, | 获取价格 | |
LF07WBP-6P-A(31) | HRS | 连接器类型:插头;安全规格:C-UL/CSA, UL;传输规格:CAT5e;额定电流:4.0 A;(AC)额定电压:AC 60.0 V;(DC)额定电压:DC 60.0 V;PIN数:6;壳体尺寸 | 获取价格 | |
LF07WBP-6S | HRS | Circular Connector, 6 Contact(s), Zinc Alloy, Male, Crimp Terminal, Plug, | 获取价格 | |
LF07WBP-6S(31) | HRS | Circular Connector, | 获取价格 | |
LF07WBP-6S-A(31) | HRS | 连接器类型:插头;安全规格:C-UL/CSA, UL;传输规格:CAT5e;额定电流:4.0 A;(AC)额定电压:AC 60.0 V;(DC)额定电压:DC 60.0 V;PIN数:6;壳体尺寸 | 获取价格 | |
LF07WBPD-6S | HRS | Miniature Waterproof Shielded Connectors | 获取价格 |
LF07WBP-3P 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6