RUUH-SH-124D [GOODSKY]
General Purpose Relay;型号: | RUUH-SH-124D |
厂家: | GOODSKY |
描述: | General Purpose Relay |
文件: | 总2页 (文件大小:357K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
RUUH/RUDH
MAIN FEATURE
1. High switching current up to 15A in small size.
2. UL, CUL & TÜV safety standard approval.
3. UL Class F insulation available.
4. Highly adapt to harsh condition with high
temperature and vibration.
5. Halogen Free series available.
6. Comply with RoHS and REACH regulations.
CONTACT RATING
Load Type
RUDH (DM/DB)
12A 120 VAC
12A 24 VDC
10A 250 VAC
12A
RUDH (D)
12A 120 VAC
12A 24 VDC
10A 250 VAC
12A
RUUH (DM/DB)
15A 120VAC
15A 30VDC
-
RUUH (D)
15A 120VAC
15A 30VDC
-
Rated Load (Resistive)
Rated Carrying Current
Max. Allowable Voltage
Max. Allowable Current
Max. Allowable Power Force
15A
15A
AC 250V
DC 110V
12A
AC 250V
DC 110V
12A
AC 250V
DC 110V
15A
AC 250V
DC 110V
15A
2500VA
2500VA
1800VA
360W
1800VA
360W
288W
288W
Ag Alloy
Ag Alloy
SPDT
Ag Alloy
SPST
Ag Alloy
SPDT
Contact Material
Contact Form
SPST
APPLICATION
Vibration:
Destruction
10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
......................
......................
Domestic Appliances, Office Machines, Audio
Equipment, Coffeepot, Control Units, etc.
Malfunction
10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
PERFORMANCE (AT INITIAL VALUE)
Shock:
Destruction ...................... 1,000 m/S2
Contact Resistance..............100m Max.@1A,6VDC
Operate Time........................15mSec. Max.
Release Time .......................5 mSec. Max.
Dielectric Strength:
...................... 100 m/S2
Malfunction
Life Expectancy:
Mechanical ...................... 107 Operations at No
Load condition
10 Operations at
Between Coil & Contact.......1,500VAC at 50/60 Hz
for one minute
5
..........................
Electrical
Rated Resistive Load
Weight ............................. About 12.2 g
Between Contacts ................750VAC at 50/60 Hz
for one minute
2,000VAC (Special spec)
Surge Strength .....................3,000V (between Coil
& Contact 1.2x50μSec.)
SAFETY STANDARD & FILE NUMBER
Insulation Resistance...........100 Mega Min. at
500VDC
Max. On/Off Switching:
Electrical ...............................6 Cycles per Minute
Mechanical............................300 Cycles per Minute
Temperature Range.............-30 +70°C
Humidity Range....................45 85% RH.
Coil Temperature Rise.........35°C Max.
RUDH:
UL & C-UL ....................... E141060
TÜV ................................ R09352326
RUUH
NIL
72
RUUH/RUDH
COIL SPECIFICATION (AT 20°C)
Power
Consumption
(W)
Maximum
Allowable
Nominal
Nominal
Coil Resistance
Pull-In Voltage
(VDC)
Drop-Out
Voltage (VDC)
Coil Sensitivity
Voltage (VDC) Current (mA)
(Ω±10%)
Voltage (VDC)
3
6
9
12
24
48
150
75
50
37.5
18.7
10.7
20
80
180
320
1,280
4,500
75%
Maximum
5%
Minimum
RUUH
RUDH
Abt. 0.45
Abt. 0.51
130%
80% Max.
ORDERING INFORMATION
RUDH - SS -
1
12
D
M
F
Insulation System:
Contact Form:
Nil: Standard Class
F: Class F (for RUDH only)
Nil: One Form C
M: One Form A
B: One Form B
Coil Type:
Coil Voltage:
D: Standard DC
03: 3V, 06: 6V, 09: 9V, 12: 12V, 24: 24V, 48: 48V
Number of Pole:
Type of Sealing:
1: One Pole
SS: RT II Flux Proofed
SH: RT III Wash Tight
RUDH
Type:
RUUH
CLASSIFICATION
RUDH / RUUH
Model
Contact Form
Flux Proofed
Wash Tight
1C
1A
1B
RUDH / RUUH -SS-1
RUDH / RUUH-SH-1
D
D
RUDH / RUUH - SS-1
RUDH / RUUH - SH-1
DM RUDH / RUUH -SS-1
DM RUDH / RUUH -SH-1
DB
DB
DIMENSION ( ≤ 5mm ± 0.2mm, > 5mm ± 0.3mm, the tolerance of PCB thru hole: +0.1mm)
Bottom View
P.C.B Layout
Bottom View
V.01EZ
www.goodsky.com.tw
73
相关型号:
©2020 ICPDF网 联系我们和版权申明