280-046P4-21WAZ2NP [GLENAIR]
D Type Connector;型号: | 280-046P4-21WAZ2NP |
厂家: | Glenair |
描述: | D Type Connector |
文件: | 总2页 (文件大小:248K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
series 28
HiPer-D Combo Connectors
280-046P combo cable pin connectors with standard mounting flange,
crimp termination
Combo HiPer-D pin connectors feature size #20 signal contacts and size #8 power
or coax contacts. Size #8 contacts are ordered separately. The HiPer-D features a
rugged machined aluminum shell, waterproof sealing and optional ground springs for
improved resistance to electromagnetic interference. Size #20 contacts are packaged
with connector. Terminate contacts with crimp tools purchased separately. Glass-
reinforced thermoset epoxy insulators, copper alloy retention clips. Fluorosilicone face
seal and rear grommet meet IPꢀ7 immersion requirement. 1000 VAC, 7.5 Amps (#20),
up to 40 Amps with size #8 power contacts.
Ordering Information
280-046P
Contact Arrangements
Contact Size and Qty
Shell Size-
Sample Part Number
Basic Part Number
3-5W5 MT
G
P
Contact Arr.
#20
#8
2
1
3
2
1
5
4
3
2
1
8
6
5
4
3
2
7
4
2
1
1-2W2
280-046P
1-5W1
4
2-3W3
Shell Sizeꢀ
Contact Arrangement
Contact Arrangements are shown in the
adjacent table
2-7W2
5
2-11W1
3-5W5
10
ME = Electroless Nickel (RoHS)
MT = Nickel-PTFE (RoHS)
3-9W4
5
JF = Cadmium with Yellow Chromate
Z2 = Gold (RoHS)
3-13W3
3-17W2
3-21W1
4-8W8
10
15
20
Shell Finish
C
Z1 = Passivated Stainless Steel (RoHS)
G = Supplied with EMI Ground Spring
N = No Ground Spring
4-13W6
4-17W5
4-21WA4
4-25W3
4-27W2
5-24W7
5-36W4
5-43W2
5-47W1
7
Ground Spring
12
17
22
25
17
32
41
46
N = No Hardware (Through-Hole)
P = #4-40 Female Jackpost
L = Jackscrew, Hex Head, Low Profile
K = Jackscrew, Slot Head, Extended Length
S = Screwlock, Male, Hex Head, Low Profile
T = Screwlock, Male, Slot Head, Extended Length
Mating Hardware
Specifications
Mating Hardware
Current Rating
Test Voltage
Insulation Resistance
#20 7.5 AMPS, #8 40 AMPS
1000 VAC RMS
5000 megohms minimum
N
P
S
Thru-Hole
Female Jackpost Captive Screwlock,
Hex Head
No Hardware
Operating Temperature -65° C. to +200° C.
#4-40 UNC-2A
NUT AND
Ingress Protection
Shock
IP 67
300 g.
43.92 g.
RETAINER
#4-40 UNC-2A
T
LOCKWASHER
Vibration, Random
.115/.125
(2.92/3.18)
#4-40 UNC-2B
Materials and Finishes
Aluminum alloy
L
K
Shell
Contacts
Insulators
Captive Jackscrew, Slot-Head Extended Slot-Head Extended
Copper alloy, 50 microinches gold
Thermoset epoxy
Hex Head
Jackscrew
Captive Screwlock
EMI Spring
Retention Clips
Grommet, Face Seal
Hardware
Copper alloy, nickel plated
Copper alloy
Fluorosilicone rubber
300 series stainless steel
1.1 (28)
MAX
1.1 (28)
MAX
RETAINER
RETAINER
RETAINER
#4-40 UNC-2A
#4-40 UNC-2A
#4-40 UNC-2A
C-6
© 2013 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324
series 28
HiPer-D Combo Connectors
280-046P combo cable pin connectors with standard mounting flange,
crimp termination
ꢁꢂꢃ-ꢃꢄꢅP DIMENSIONS
OPTIONAL SEALING BOOT
SUPPLIED WITH CONTACT OR
ORDERED SEPARATELY
1.129 (28.68)
(REF)
A
Ø .120 (3.05)
C
D
TYP
.435
(11.05)
.049
F
REF .134
(3.40)
R
(1.24)
E
A5
A4
A3
A2
A1
A1
A2
A3
A4
A5
G
B
C
BACKSHELL
MOUNTING
GROOVE
.262 ± .005
(6.65 ± 0.13)
OPTIONAL GROUND
SPRING 2 PLCS
10°
TYP
10°
TYP
Dimensions
A
B
C Basic
D
E
F Max.
G Max.
Shell
in
mm
in
mm
in
mm
in
mm
Size ± .015 ± 0.38 ± .015 ± 0.38 in.
mm ± .005 ± 0.13 ± .005 ± 0.13 in.
mm
in.
mm
1.213 30.81
1.541 39.14
2.088 53.04
2.729 69.32
2.635 66.93
.494 12.55
.984 24.99 .726 18.44 .389 9.88 .769 19.53
.432 10.97
.432 10.97
.432 10.97
.432 10.97
.544 13.82
1
2
3
4
5
.494 12.55 1.312 33.32 1.054 26.77
.494 12.55 1.852 47.04 1.594 40.49
.494 12.55 2.500 63.50 2.242 56.95
.605 15.37 2.406 61.11 2.139 54.33
.389 9.88 1.093 27.76
.389 9.88 1.635 41.53
.389 9.88 2.282 57.96
.501 12.73 2.188 55.58
NOTES
1. See About Series 28 HiPer-D Shell Plating Options for additional shell material and finish options. Glenair offers the industry’s
widest selection of plating options with no minimum order quantities or setup charges.
2. For panel cutouts, refer to Panel Cutouts and Printed Circuit Board Footprints.
3. Connectors are supplied with size #20 crimp contacts per M39029. Contacts are not installed. Refer to HiPer-D Contacts and Tools
section for contact part numbers, specifications, crimp tool information, and insertion/extraction tools.
4. Size 8 contacts are ordered separately. Refer to HiPer-D Contacts and Tools section for contact ordering information, specifications,
crimp tool information, and insertion/extraction tools.
5. Combo HiPer-D connectors meet the applicable requirements of MIL-DTL-24308 and are intermateable with standard non-
environmental D Subminiature connectors with corresponding contact arrangements and type. Size 8 contacts from other
manufacturers cannot be installed in HiPer-D connectors.
ꢀ. Additional electrical, mechanical and environmental specifications are listed in HiPer-D Product Specification.
C-ꢁ
© 2013 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324
相关型号:
©2020 ICPDF网 联系我们和版权申明