4GH523M [FUJI]

Power/Signal Relay, 5PST, Momentary, 24VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount;
4GH523M
型号: 4GH523M
厂家: FUJI ELECTRIC    FUJI ELECTRIC
描述:

Power/Signal Relay, 5PST, Momentary, 24VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount

文件: 总4页 (文件大小:253K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
"ORANGE LINE" INDUSTRIAL RELAY  
Features and Ratings  
FEATURES  
NEW SH SERIES EXPANDABLE INDUSTRIAL RELAY  
APPLICATIONS (U.S. Catalog No.4SH and 4GH Series)  
High contact reliability that accommodates electronic devices.  
All contacts are bifurcated, providing high contact reliability  
(minimum operational voltage and current: 5V and 3mA DC)  
and enabling direct input to an electronic control circuit.  
A wide variety of optional units.  
In addition to an auxiliary contact block (two or four poles),  
many function units such as a coil surge suppression unit and  
terminal covers can be installed on standard industrial relays.  
This allows for flexibility and easy modification in the field.  
Snap-on mounting on an IEC or DIN rail.  
industrial relays. In addition to the mounting holes needed for  
the compatibility, mounting holes based on the IEC Standard  
are also provided.  
All models can be mounted on an IEC or DIN Standard  
35mm rail.  
Meets International Standards.  
Terminal numbers conforming to IEC Standards.  
Terminal numbers are based on IEC Standards.  
New design.  
The SH Series industrial relays conform to the following  
International Standards: IEC, NEMA, BS and VDE. They are  
also UL, CSA, BV and Lloyd approved.  
Compatible with conventional models.  
The arc extinguishing cover is ivory colored with orange  
accents, providing a new look to the conventional industrial  
relay.  
SH Series industrial relays are compatible with the  
discontinued Fuji SRCa50-3/X, SRCa50-3F/X, and SRC50-05/X  
AC OPERATED INDUSTRIAL RELAYS  
DC OPERATED INDUSTRIAL RELAYS  
U.S. Catalog No.  
Aux. Contact  
Fuji Type  
U.S. Catalog No.  
Aux. Contact  
Fuji Type  
4SH440#  
4SH431#  
4SH422#  
4NO  
3NO+1NC  
2NO+2NC  
4GH440#  
4GH431#  
4GH422#  
4NO  
3NO+1NC  
2NO+2NC  
SH-4  
4 POLE  
SH-4/G  
4 POLE  
4SH880#  
4SH871#  
4SH862#  
4SH853#  
4SH844#  
8NO  
4GH880#  
4GH871#  
4GH862#  
4GH853#  
4GH844#  
8NO  
7NO+1NC  
6NO+2NC  
5NO+3NC  
4NO+4NC  
7NO+1NC  
6NO+2NC  
5NO+3NC  
4NO+4NC  
SH-4  
8 POLE  
SH-4/G  
8 POLE  
4SH550#  
4SH541#  
4SH532#  
4SH523#  
4SH514#  
4SH505#  
5NO  
4GH550#  
4GH541#  
4GH532#  
4GH523#  
4GH514#  
4GH505#  
5NO  
4NO+1NC  
3NO+2NC  
2NO+3NC  
1NO+4NC  
5NC  
4NO+1NC  
3NO+2NC  
2NO+3NC  
1NO+4NC  
5NC  
SH-5  
5 POLE  
SH-5/G  
5 POLE  
EXPLANATION OF PART NUMBER SYSTEM  
4 S H 4 2 2 #  
APPROVAL  
4=UL Listed  
JIS Approved  
COIL VOLTAGE  
OPERATION  
S=AC Coil  
G=DC Coil  
Select code from chart on next page  
For AC: use Table 1  
For DC: use Table 2  
QUANTITY OF N.C. AUX. CONTACTS  
QUANTITY OF N.O. AUX. CONTACTS  
TOTAL NUMBER OF CONTACTS  
DESCRIPTION  
H=Industrial Relay  
"ORANGE LINE" INDUSTRIAL RELAY  
Coil and Operating Characteristics, and Performance Data  
AVAILABLE COILS  
TABLE 1: AC Coils  
TABLE 2: DC Coils  
Code Letter  
AC coil 60Hz  
AC coil 50Hz  
Code Letter  
DC coil  
E
F
2426V  
4852V  
24V  
48V  
T
M
N
1
R
2
S
12V  
24V  
A
100110V  
100V  
48V  
100V  
110V  
200V  
220V  
1
G
B
110120V  
120 –130V  
200220V  
100110V  
110 120V  
200V  
2
220240V  
200220V  
4
5
440480V  
550600V  
415440V  
500650V  
COIL CHARACTERISTICS  
Power Consumption  
Pick-Up Voltage (V)  
Drop-Out Voltage (V)  
Watt Loss (W)  
Inrush (VA) Sealed (VA)  
200V, 50Hz.  
220V, 60Hz.  
200V, 50Hz.  
220V, 60Hz.  
74–100  
200V, 50Hz.  
2.7  
220V, 60Hz.  
95  
9
108–128  
120–144  
62–90  
2.8  
OPERATING CHARACTERISTICS  
Pick-Up Time (m sec.)  
Drop-Out Time (m sec.)  
Coil Type  
Voltage  
Frequency (Hz)  
No Contact  
NC Contact  
OFF  
NO Contact  
OFF  
NC Contact  
ON  
ON  
AC  
DC  
200V AC  
200V DC  
50  
9–20  
5–15  
5–15  
9–20  
45–50  
35–40  
20–25  
20–30  
RATINGS UL File No. E44592, CSA File No. LR20479  
Rated Operational Current (A)  
Code  
Continuous  
Current (A)  
AC  
Volts  
DC  
Break  
Make  
Make  
Break  
AC  
DC  
Q300  
Volts  
10  
120  
240  
480  
600  
60  
30  
15  
12  
6
125  
250  
0.55  
0.27  
0.55  
0.27  
A600  
3
1.5  
1.2  
PERFORMANCE DATA (AC11) Life Expectancy (Conforming to JIS C4531, JEM1230)  
Electrical Life (Operations)  
Operating Cycles  
Per Hour  
Mechnical Life  
(Operations)  
AC11  
AC13  
DC11, 14  
220V  
440V  
220V  
440V  
24V~220V  
1,800  
10 Million  
500,000  
500,000  
250,000  
250,000  
500,000  
"ORANGE LINE" INDUS TRIAL RELAY  
Co m b in a t io n s a n d Co n t a c t Arra n g e m e n t s  
COMBINATION OF INDUSTRIAL RELAY AND AUXILIARY CONTACT BLOCK  
The standard type industrial relays can be used with a com bination of the auxiliary contact blocks shown below.  
Auxiliary Contact Block  
Front Mounting  
Industrial Relay  
Side Mounting  
Type  
Contact  
SZ-A40  
4NO  
SZ-A31  
3NO + 1NC 2NO + 2NC  
SZ-A22  
SZ-A20  
2NO  
SZ-A11  
1NO + 1NC  
SZ-A02  
2NC  
SZ-AL+SZ-AR  
2NO + 2NC 1NO + 1NC 1NO + 1NC  
SZ-AL  
SZ-AR  
(U.S. Cat. No.) Arrangem ent  
SH-4  
(4SH4)  
4NO  
8NO  
7NO + 1NC 6NO + 2NC  
6NO  
5NO + 1NC 4NO + 2NC 6NO + 2NC 5NO + 1NC 5NO + 1NC  
3NO + 1NC 7NO + 1NC 6NO + 2NC 5NO + 3NC 5NO + 1NC 4NO + 2NC 3NO + 3NC 5NO + 3NC 4NO + 2NC 4NO + 2NC  
2NO + 2NC 6NO + 2NC 5NO + 3NC 4NO + 4NC 4NO + 2NC 3NO + 3NC 2NO + 4NC 4NO + 4NC 3NO + 3NC 3NO + 3NC  
SH-4/G  
(4GH4)  
SH-5  
(4SH5)  
5NO  
9NO  
8NO + 1NC 7NO + 2NC  
7NO  
6NO + 1NC 5NO + 2NC 7NO + 2NC 6NO + 1NC 6NO + 1NC  
4NO + 1NC 8NO + 1NC 7NO + 2NC 6NO + 3NC 6NO + 1NC 5NO + 2NC 4NO + 3NC 6NO + 3NC 5NO + 2NC 5NO + 2NC  
3NO + 2NC 7NO + 2NC 6NO + 3NC 5NO + 4NC 5NO + 2NC 4NO + 3NC 3NO + 4NC 5NO + 4NC 4NO + 3NC 4NO + 3NC  
SH-5/G  
(4GH5)  
2NO + 3NC 6NO + 3NC 5NO + 4NC  
4NO + 3NC 3NO + 4NC  
3NO + 4NC 3NO + 4NC  
1NO + 4NC 5NO + 4NC  
5NC 4NO + 5NC  
3NO + 4NC  
2NO + 5NC  
Note: Auxiliary contact blocks cannot be m ounted both front m ounting and side m ounting at the sam e tim e.  
CONTACT ARRANGEMENT  
Contact Arrangem ent  
NO NC  
Contact Arrangem ent  
U.S.  
Catalog  
No.  
U.S.  
Catalog  
No.  
Fuji  
Type  
Fuji  
Type  
NO NC  
4SH440#  
4GH440#  
SH-4  
4-Pole  
4SH550#  
4GH550#  
SH-5  
5-Pole  
4NO  
5NO  
SH-4/G  
4-Pole  
SH-5/G  
5-Pole  
4SH431#  
4GH431#  
4SH541#  
4GH541#  
3NO + 1NC  
2NO + 2NC  
8NO  
4NO + 1NC  
3NO + 2NC  
2NO + 3NC  
1NO + 4NC  
5NC  
4SH422#  
4GH422#  
4SH532#  
4GH532#  
*
4SH880#  
4GH880#  
SH-4  
4SH523#  
4GH523#  
8-Pole  
SH-4/G  
8-Pole  
4SH871#  
4GH871#  
4SH514#  
4GH514#  
7NO + 1NC  
6NO + 2NC  
5NO + 3NC  
4NO + 4NC  
4SH862#  
4GH862#  
4SH505#  
4GH505#  
*Note: 8 pole units are m ade from standard 4 pole fram es  
with 4 pole Aux. contacts added. The 5 available  
configurations are m ade as follows:  
4SH853#  
4GH853#  
4_H880# (8NO, no NC) = 4_H440# Base + SZ-A40 Aux.  
4_H871# (7NO + 1 NC) = 4_H440# Base + SZ-A31 Aux.  
4_H862# (6NO + 2 NC) = 4_H440# Base + SZ-A22 Aux.  
4_H853# (5NO + 3 NC) = 4_H422# Base + SZ-A31 Aux.  
4_H844# (4NO + 4 NC) = 4_H422# Base + SZ-A22 Aux.  
4SH844#  
4GH844#  
"ORANGE LINE" INDUS TRIAL RELAY  
Dim e n s io n s  
DIMENSIONS: m m (inches)  
Notes: Panel Drilling -  
Use the two m ounting holes on a diagonal line to m ount a relay.  
Mounting holes indicated by are com patible with those of SRC type.  
Mounting holes indicated by conform to IEC Standards.  

相关型号:

4GH523N

Power/Signal Relay, 5PST, Momentary, 48VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH523R

Power/Signal Relay, 5PST, Momentary, 110VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH523S

Power/Signal Relay, 5PST, Momentary, 220VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH523T

Power/Signal Relay, 5PST, Momentary, 12VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH5321

Power/Signal Relay, 5PST, Momentary, 100VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH5322

Power/Signal Relay, 5PST, Momentary, 200VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH532M

Power/Signal Relay, 5PST, Momentary, 24VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH532N

Power/Signal Relay, 5PST, Momentary, 48VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH532R

Power/Signal Relay, 5PST, Momentary, 110VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH532S

Power/Signal Relay, 5PST, Momentary, 220VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH532T

Power/Signal Relay, 5PST, Momentary, 12VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI

4GH5411

Power/Signal Relay, 5PST, Momentary, 100VDC (Coil), 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
FUJI