KA78M08I [FAIRCHILD]

Fixed Positive Standard Regulator, 8VBIPolar, PSFM3, TO-220, 3 PIN;
KA78M08I
型号: KA78M08I
厂家: FAIRCHILD SEMICONDUCTOR    FAIRCHILD SEMICONDUCTOR
描述:

Fixed Positive Standard Regulator, 8VBIPolar, PSFM3, TO-220, 3 PIN

局域网 输出元件 调节器
文件: 总18页 (文件大小:101K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
www.fairchildsemi.com  
MC78MXX (LM78MXX) (KA78MXX)  
3-Terminal 0.5A Positive Voltage Regulators  
Features  
Description  
• Output Current up to 0.5A  
• Output Voltages of 5, 6, 8, 10, 12, 15, 18, 20, 24V  
• Thermal Overload Protection  
The MC78MXX (LM78MXX) (KA78MXX) series of three-  
terminal positive regulators are available in the TO-220/  
D-PAK package with several fixed output voltages making it  
useful in a wide range of applications.  
• Short Circuit Protection  
• Output Transistor SOA Protection  
• Industrial and commercial temperature range  
TO-220  
D-PAK  
1. Input 2. GND 3. Output  
Rev. 1.0.0  
©2000 Fairchild Semiconductor Corporation  
MC78MXX (LM78MXX) (KA78MXX)  
Internal Block Diagram  
2
MC78MXX (LM78MXX) (KA78MXX)  
Absolute Maximum Ratings (Ta=+25°C, Unless otherwise specified)  
Parameter  
Symbol  
Value  
Unit  
Input Voltage (for V = 5V to 18V)  
V
V
35  
40  
V
V
O
I
I
(for V = 24V)  
O
Thermal Resistance Junction-Cases  
Thermal Resistance Junction-Air  
R
5
°C/W  
°C/W  
JC  
JA  
θ
R
65  
θ
Operating Temperature Range KA78MXXI/RI  
KA78MXX/R  
T
OPR  
-40~ + 125  
0~ + 125  
°C  
°C  
Storage Temperature Range  
T
-65~ + 150  
°C  
STG  
KA78M05/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =10V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
4.8  
Typ.  
Max.  
5.2  
Units  
Output Voltage  
V
O
T =+25°C  
5
5
V
J
I
= 5 to 350mA  
4.75  
5.25  
O
V = 7 to 20V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V  
V  
I
= 200mA  
V = 7 to 25V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
I
T =+25°C  
J
V = 8 to 25V  
I
-
I
I
= 5mA to 0.5A, T =+25°C  
-
100  
50  
O
O
O
J
= 5mA to 200mA, T =+25 °C  
-
4.0  
-
J
I
T =+25°C  
6
mA  
mA  
Q
J
Quiescent Current  
Change  
I  
I
= 5mA to 350mA  
= 200mA  
0.5  
0.8  
Q
O
I
-
O
V = 8 to 25V  
I
Output Voltage Drift  
V/T  
I
= 5mA  
-
- 0.5  
-
mV/°C  
O
T = 0 to +125°C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
40  
-
-
-
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
62  
O
V = 8 to 18V  
I
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25°C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
I
T =+25°C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
I
T =+25°C  
J
PK  
NOTE:  
1. T  
T
<
MIN  
T
<
J MAX  
KA78MXX/Rl: T  
KA78MXX/R: T  
= -40 C, T  
= +125 C  
°
°
MIN  
MAX  
= +125 C  
MAX  
= 0 C, T  
°
°
MIN  
2. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
3
MC78MXX (LM78MXX) (KA78MXX)  
KA78M06/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =11V, unless otherwise specified, C = 0.33mF, C =0.1mF)(  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
5.75  
5.7  
Typ.  
Max.  
6.25  
6.3  
Units  
°
Output Voltage  
V
O
TJ=+25 C  
6
6
V
I
= 5 to 350mA  
O
V = 8 to 21V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 8 to 25V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 9 to 25V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
120  
60  
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.0  
-
J
°
I
T =+25 C  
6
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 9 to 25V  
I
°
mV/ C  
Output Voltage Drift  
V/ T  
I
= 5mA  
-
- 0.5  
-
O
°
T = 0 to +125 C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
45  
-
-
-
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
59  
O
V = 9 to 19V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T =+25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
KA78MXX/R: T  
= -40°C  
= 0°C  
MIN  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
4
MC78MXX (LM78MXX) (KA78MXX)  
KA78M08/I/R/RI ELECTRICAL CHARACTERISTICS  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =14V, unless otherwise specified, C =0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
7.7  
Typ.  
Max.  
Units  
°
Output Voltage  
V
O
T =+25 C  
8
8
8.3  
8.4  
V
J
I
= 5 to 350mA  
7.6  
O
V = 10.5 to 23V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 10.5 to 25V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 11 to 25V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
160  
80  
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.0  
-
J
°
I
T =+25 C  
6
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 10.5 to 25V  
I
°
mV/ C  
Output Voltage Drift  
RR  
I
= 5mA  
-
- 0.5  
-
O
°
T = 0 to +125 C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
52  
-
-
-
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
56  
O
V = 9 to 19V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C,I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T =+25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T =+25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
5
MC78MXX (LM78MXX) (KA78MXX)  
KA78M10/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =17V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
9.6  
Typ.  
10  
Max.  
Units  
°
Output Voltage  
V
O
T = +25 C  
10.4  
10.5  
V
J
I
= 5 to 350mA  
9.5  
10  
O
V = 12.5 to 25V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 12.5 to 25V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 13 to 25V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
200  
100  
6
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.1  
-
J
°
I
T =+25 C  
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 12.5 to 25V  
I
°
Output Voltage Drift  
V/ T  
I
= 5mA  
-
- 0.5  
-
mV/ C  
O
°
T = 0 to +125 C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
65  
-
-
-
mV/V  
N
O
RR  
f = 120Hz, I = 300mA  
55  
dB  
O
V = 13 to 23V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T =+25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
6
MC78MXX (LM78MXX) (KA78MXX)  
KA78M12/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T 125°C, I =350mA, V =19V, unless otherwise specified, C =0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
11.5  
11.5  
Typ.  
12  
Max.  
12.5  
12.6  
Units  
°
Output Voltage  
V
O
T =+25 C  
V
J
I
= 5 to 350mA  
12  
O
V = 14.5 to 27V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 14.5 to 30V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 16 to 30V  
I
-
-
O
V
°
I
I
= 5mA to 0.5A, T =+25 C  
240  
120  
6
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
J
°
I
T =+25 C  
4.1  
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 14.5 to 30V  
I
°
mV/ C  
Output Voltage Drift  
V/ T  
I
= 5mA  
-
- 0.5  
75  
-
O
J
°
T = 0 to +125 C  
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
-
-
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
55  
O
V = 15 to 25V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T = +25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
7
MC78MXX (LM78MXX) (KA78MXX)  
KA78M15/I/R/RI ELECTRICAL CHARACTERISTICS  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =23V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
14.4  
Typ.  
15  
Max.  
15.6  
Units  
°
Output Voltage  
V
O
T =+25 C  
V
J
I
= 5 to 350mA  
14.25  
15  
15.75  
O
V = 17.5 to 30V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 17.5 to 30V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 20 to 30V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
300  
150  
6
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.1  
-
J
°
I
T =+25 C  
mA  
mA  
Q
J
Quiescent Current Change  
I
Q
I
= 5mA to 350mA  
0.5  
0.8  
O
I
= 200mA  
-
O
V = 17.5 to 30V  
I
°
mV/ C  
Output Voltage Drift  
V/ T  
I
= 5mA  
-
- 1  
-
-
O
J
°
T = 0 to +125 C  
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
100  
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
54  
O
V = 18.5 to 28.5V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T = + 25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
8
MC78MXX (LM78MXX) (KA78MXX)  
KA78M18/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =26V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
17.3  
17.1  
Typ.  
18  
Max.  
18.7  
18.9  
Units  
°
Output Voltage  
V
O
T =+25 C  
V
J
I
= 5 to 350mA  
18  
O
V = 20.5 to 33V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 21 to 33V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
I
°
T =+25 C  
V = 24 to 33V  
I
-
J
∆ Ο  
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
360  
180  
6
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.2  
-
J
°
I
T =+25 C  
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 21 to 33V  
I
°
mV/ C  
Output Voltage Drift  
V/ T  
I
=5mA  
-
-1.1  
100  
-
O
J
°
T =0 to 125 C  
µ
Output Noise Voltage  
Ripple Rejection  
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
f=10Hz to 100KHz  
-
-
-
-
-
V/V  
dB  
V
N
O
RR  
f=120Hz, I =300mA  
53  
-
O
°
V
T =+25 C, I =500mA  
2
D
J
O
°
I
T =+25 C, V =35V  
-
300  
700  
mA  
mA  
SC  
J
I
°
I
T =+25 C  
-
PK  
J
NOTE:  
1. T  
:
MIN  
KA78MXX/R: T  
KA78MXX/R: T  
= -40°C  
= 0°C  
MIN  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
9
MC78MXX (LM78MXX) (KA78MXX)  
KA78M20/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =29V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
19.2  
19  
Typ.  
20  
Max.  
Units  
°
Output Voltage  
V
O
T = +25 C  
20.8  
21  
V
J
I
= 5 to 350mA  
20  
O
V = 23 to 35V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 23 to 35V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 24 to 35V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
400  
200  
6
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.2  
-
J
°
I
T =+25 C  
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 23 to 35V  
I
°
mV/ C  
Output Voltage Drift  
V/ T  
I
= 5mA  
-
-1.1  
-
O
°
T = 0 to +125 C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
110  
-
-
-
mV/V  
dB  
N
O
RR  
f = 120Hz, I = 300mA  
53  
O
V = 24 to 34V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T = +25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
10  
MC78MXX (LM78MXX) (KA78MXX)  
KA78M24/I/R/RI Electrical Characteristics  
(Refer to the test circuits, T  
T +125°C, I =350mA, V =33V, unless otherwise specified, C = 0.33mF, C =0.1mF)  
MIN  
J
O
I
I
O
Parameter  
Symbol  
Conditions  
Min.  
23  
Typ.  
24  
Max.  
25  
Units  
°
Output Voltage  
V
O
T =+25 C  
V
J
I
= 5 to 350mA  
22.8  
24  
25.2  
O
V = 27 to 38V  
I
Line Regulation  
Load Regulation  
Quiescent Current  
V
I
= 200mA V = 27 to 38V  
-
-
-
-
-
-
-
-
100  
50  
mV  
mV  
O
O
J
I
°
T =+25 C  
V = 28 to 38V  
I
-
V
°
I
I
= 5mA to 0.5A, T =+25 C  
-
480  
240  
6
O
O
O
J
°
= 5mA to 200mA, T =+25 C  
-
4.2  
-
J
°
I
T =+25 C  
mA  
mA  
Q
J
Quiescent Current Change  
I
I
= 5mA to 350mA  
0.5  
0.8  
Q
O
I
= 200mA  
-
O
V = 27 to 38V  
I
°
Output Voltage Drift  
V/ T  
I
= 5mA  
-
- 1.2  
-
mV/ C  
O
°
T = 0 to +125 C  
J
Output Noise Voltage  
Ripple Rejection  
V
f = 10Hz to 100KHz  
-
170  
-
-
-
mV/V  
N
O
RR  
f = 120Hz, I = 300mA  
50  
dB  
O
V = 28 to 38V  
I
°
Dropout Voltage  
Short Circuit Current  
Peak Current  
V
T =+25 C, I = 500mA  
-
-
-
2
-
-
-
V
D
J
O
°
I
T = +25 C, V = 35V  
300  
700  
mA  
mA  
SC  
J
I
°
T =+25 C  
J
I
PK  
NOTE:  
1. T  
:
MIN  
KA78MXX/RI: T  
= -40°C  
= 0°C  
MIN  
KA78MXX/R: T  
MIN  
2. Load and line regulation are specified at constant, junction temperature. Change in V due to heating effects must be taken  
O
into account separately. Pulse testing with low duty is used.  
11  
MC78MXX (LM78MXX) (KA78MXX)  
Typical Applications  
Figure 1. Fixed Output Regulator  
Figure 2. Constant Current Regulator  
Notes:  
1. To specify an output voltage, substitute voltage value for "XX"  
2. Although no output capacitor is needed for stability, it does improve transient response.  
3. Required if regulator is located an appreciable distance from power Supply filter  
Figure 3. Circuit for Increasing Output Voltage  
12  
MC78MXX (LM78MXX) (KA78MXX)  
Figure 4. Adjustable Output Regulator (7 to 30V)  
Figure 5. 0.5 to 10V Regulator  
13  
MC78MXX (LM78MXX) (KA78MXX)  
Ordering Information  
Device  
MC78MXXCT (LM78XXCT) (KA78MXX)  
KA78MXXI  
Package  
Operating Temperature  
0 ~ + 125°C  
TO-220  
-40 ~ +125°C  
MC78MXXCDT (KA78MXXR)  
KA78MXXRI  
D-PAK  
0 ~ + 125°C  
-40 ~ + 125°C  
14  
MC78MXX (LM78MXX) (KA78MXX)  
Package Dimensions  
15  
MC78MXX (LM78MXX) (KA78MXX)  
Package Dimensions (Continued)  
16  
MC78MXX (LM78MXX) (KA78MXX)  
17  
MC78MXX (LM78MXX) (KA78MXX)  
LIFE SUPPORT POLICY  
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES  
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR  
CORPORATION. As used herein:  
1. Life support devices or systems are devices or systems  
which, (a) are intended for surgical implant into the body,  
or (b) support or sustain life, and (c) whose failure to  
perform when properly used in accordance with  
instructions for use provided in the labeling, can be  
reasonably expected to result in a significant injury of the  
user.  
2. A critical component in any component of a life support  
device or system whose failure to perform can be  
reasonably expected to cause the failure of the life support  
device or system, or to affect its safety or effectiveness.  
www.fairchildsemi.com  
1/3/00 0.0m 001  
Stock#DSxxxxxxxx  
1999 Fairchild Semiconductor Corporation  

相关型号:

KA78M08R

3-terminal 0.5A positive voltage regulator
FAIRCHILD

KA78M08RI

Positive Fixed Voltage Regulator
ETC

KA78M08RTF

Fixed Positive Standard Regulator, 8VBIPolar, PSSO2, TO-252, DPAK-3
FAIRCHILD

KA78M08RTF

Fixed Positive Standard Regulator, 8VPSSO2, TO-252, DPAK-3
ROCHESTER

KA78M08RTM

Fixed Positive Standard Regulator, 8VBIPolar, PSSO2, TO-252, DPAK-3
FAIRCHILD

KA78M08RTM

Fixed Positive Standard Regulator, 8VPSSO2, TO-252, DPAK-3
ROCHESTER

KA78M08RTM_NL

暂无描述
FAIRCHILD

KA78M08TSTU

Fixed Positive Standard Regulator, 8VPSFM3, TO-220, 3 PIN
FAIRCHILD

KA78M08TSTU

Fixed Positive Standard Regulator, 8VPSFM3, TO-220, 3 PIN
ROCHESTER

KA78M08TU

Fixed Positive Standard Regulator, 8VBIPolar, PSFM3, TO-220, 3 PIN
FAIRCHILD

KA78M08TU

Fixed Positive Standard Regulator, 8VPSFM3, TO-220, 3 PIN
ROCHESTER

KA78M09

Fixed Positive Standard Regulator, 9VPSFM3, TO-220, 3 PIN
FAIRCHILD