MA150 [EXTECH]

200A AC Mini Clamp-on Meter; 200A交流微型钳型表
MA150
型号: MA150
厂家: EXTECH INSTRUMENTS CORPORATION.    EXTECH INSTRUMENTS CORPORATION.
描述:

200A AC Mini Clamp-on Meter
200A交流微型钳型表

文件: 总7页 (文件大小:200K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
User’s Guide  
Model MA150  
200A AC Mini Clamp-on Meter  
2000 count LCD display  
White LED backlight  
Built-in non-contact AC voltage detector plus flashlight  
Max Hold  
Autoranging with auto power off  
0.7” (18mm) Jaw opening  
Introduction  
Congratulations on your purchase of Extech’s MA150 AC Mini Clamp Meter. This meter is  
shipped fully tested and calibrated and, with proper use, will provide years of reliable  
service.  
Meter Description  
1. Current sense jaw  
6. LCD display  
7. Clamp trigger  
8. MODE key  
2. Non-contact AC voltage indicator light  
3. Flashlight button  
4. Rotary function switch  
9. COM input jack  
10. V input jack  
5. MAX hold and Backlight key  
9
10  
Safety Information  
Caution! Refer to the explanation in this Manual  
Double Insulation  
!
This meter has been designed to be safe in use, but the operator must use caution in its  
operation. The rules listed below should be carefully followed for safe operation.  
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:  
2. USE EXTREME CAUTION when working with voltages greater than 60VDC or 25VAC  
rms. These voltages are considerd a shock hazard.  
3. NEVER operate the meter unless the back cover and the battery/fuse door are in place  
and fastened securely.  
Input Limits  
Function  
AC Current  
Maximum Input  
200A  
AC/DC Voltage  
Resistance, Diode, Continuity Test  
600V AC/DC  
600V AC/DC  
MA150 Ver. 2.0 08/07  
2
Operation  
AC Current Measurements  
1) Set the Function switch to the 200A AC range.  
Yes  
No  
2) Press the jaw trigger and clamp around, fully enclosing a single  
conductor. Do not allow a gap between the two halves of the jaw.  
Refer to the diagram at right for the correct way to enclose a single  
conductor.  
3) Read the ACA value on the LCD.  
AC/DC Voltage Measurements  
1) Insert the black test lead into the negative COM terminal and the red test lead into the  
positive V terminal.  
2) Set the function switch to the V position.  
3) Select AC or DC with the MODE button.  
4) Connect the test leads in parallel to the circuit under test.  
5) Read the voltage measurement on the LCD display.  
Resistance and Continuity Measurements  
1) Insert the black test lead into the negative COM terminal and the red test lead into the  
positive V terminal.  
2) Set the function switch to the Ω  
position.  
3) Use the MODE button to select resistance. The Micon will appear in the display.  
4) Touch the test leads across the circuit or component under test. It is best to disconnect  
one side of the device under test so the rest of the circuit will not interfere with the  
resistance reading.  
5) For Resistance tests, read the resistance on the LCD display  
6) For Continuity, use the MODE button to select continuity “)))”. The display icons will  
change when the MODE button is pressed.  
7) If the resistance is <120 a tone will sound.  
Diode Test  
1) Insert the black test lead banana plug into the negative COM jack and the red test lead  
banana plug into the positive V jack.  
2) Set the function switch to the Ω  
position.  
on the display.  
3) Press the MODE button to indicate  
4) Touch the test probes to the diode under test. Forward voltage will typically indicate  
0.400 to 0.700V. Reverse voltage will indicate “OL”. Shorted devices will indicate near  
0V and an open device will indicate “OL” in both polarities.  
MA150 Ver. 2.0 08/07  
3
Non-Contact AC Voltage Detection  
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a  
known live circuit to verify proper operation  
1) AC Voltage detection operates on any of the three Function switch positions.  
2) Touch the probe tip to the hot conductor or insert into the hot side of the electrical  
outlet.  
3) If AC voltage is present, the detector light will illuminate.  
NOTE: The conductors in electrical cord sets are often twisted. For best results, slowly  
slide the probe tip along a length of the cord to assure placing the tip in close  
proximity to the live conductor.  
NOTE: The detector is designed with high sensitivity. Static electricity or other sources of  
energy may randomly turn the detector light on. This is normal operation  
MAX Hold  
To hold the highest reading on the LCD, momentarily press the “MAX ” key. The meter  
reading will not change as readings change, rather it will only display the highest reading  
encountered since the MAX hold button was pressed. Press the MAX hold button again to  
return the meter to normal operation.  
Backlight  
Press and hold the “MAX ” key for more than one second to turn the backlight on. This will  
also activate the MAX Hold function. To release the MAX Hold function and return the meter  
to normal operation, press the “MAX ” key momentarily. The backlight will automatically turn  
off after 15 seconds. To manually turn off the backlight, press and hold the “MAX ” key for  
more than 1 second.  
Flashlight  
Press and hold the top button to turn the flashlight on. Release the button to turn the  
flashlight off.  
MA150 Ver. 2.0 08/07  
4
Specifications  
General Specifications  
Display  
2000 count Digit LCD with white LED backlight  
Minus sign (-) indicates negative polarity  
0.7” (18mm)  
Polarity  
Jaw opening  
Current sensor  
AC Current Bandwidth  
AC Voltage Bandwidth  
Overload indication  
Display rate  
Hall effect sensor type  
50/60Hz  
50/400Hz  
“OL” displayed on the LCD  
2 readings/second, nominal  
Two 1.5V AAA batteries  
“BATT” displayed on the LCD  
approx. 15 minutes  
Battery  
Low Battery indication  
Auto Power off  
Operating conditions  
32 to 86ºF (0 to 30ºC) 90%RH; 86 to 104ºF (30 to 40ºC) 75%RH;  
104 to 122ºF (40 to 50ºC) 45%RH  
Storage conditions  
Altitude  
- 14 to 140ºF (-30 to 60ºC); < 90% Relative Humidity  
Operate at less than 3000 meters  
Weight  
6.2 oz. (176g) including battery  
Dimensions  
Standards  
6.5 x 2.6 x 1.3” (164 x 65 x 32mm) (HWD)  
For indoor use and in accordance with the requirements for  
double insulation to IEC1010-1 (1995): EN61010-1 (1995)  
Overvoltage Category III 300V and Category II 600V, Pollution  
Degree 2.  
C
C
MA150 Ver. 2.0 08/07  
5
Range Specifications  
Function  
Range  
200.0A  
200.0mV  
2.000V  
20.00V  
200.0V  
600V  
Resolution  
0.1A  
0.1mV  
1mV  
10mV  
0.1V  
1V  
Accuracy (of reading)  
± (2.5% rdg + 10 digits)  
±(0.5% rdg + 5 digits)  
AC Current  
DC Voltage  
±(1.2% rdg + 3 digits)  
±(1.5% rdg + 3 digits)  
±(1.5% rdg + 3 digits)  
AC Voltage  
Resistance  
2.000V  
20.00V  
200.0V  
600V  
1mV  
10mV  
0.1V  
1V  
±(2.0% rdg + 4 digits)  
±(1.0% rdg + 4 digits)  
200.0Ω  
2.000kΩ  
20.00kΩ  
200.0kΩ  
2.000MΩ  
20.00MΩ  
0.1Ω  
1Ω  
±(1.5% rdg + 2 digits)  
10Ω  
100Ω  
1kΩ  
±(2.0% rdg + 3 digits)  
±(3.0% rdg + 5 digits)  
10kΩ  
Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz  
Test current: 0.3mA typical;  
Diode Test  
Open circuit voltage: 1.5VDC typical  
Continuity  
Threshold <120Ω  
Test current <1mA  
MA150 Ver. 2.0 08/07  
6
Maintenance  
Battery Replacement  
1) When the low battery symbol appears on the LCD the batteries must be replaced.  
2) Power down and remove the rear battery compartment Phillips screw.  
3) Lift off the battery compartment cover and replace the two 1.5V AAA cells.  
4) Replace compartment cover and secure the screw.  
Cleaning  
Caution: Use only a dry cloth to clean the plastic case.  
Calibration and Repair Services  
Extech offers repair and calibration services for the products we sell. Extech also  
provides NIST certification for most products. Call the Customer Service Department for  
information on calibration services available for this product. Extech recommends that  
annual calibrations be performed to verify meter performance and accuracy.  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in  
parts and workmanship for one year from date of shipment (a six month limited warranty  
applies to sensors and cables). If it should become necessary to return the instrument for  
service during or beyond the warranty period, contact the Customer Service Department at  
(781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact  
information. A Return Authorization (RA) number must be issued before any product is  
returned to Extech. The sender is responsible for shipping charges, freight, insurance and  
proper packaging to prevent damage in transit. This warranty does not apply to defects  
resulting from action of the user such as misuse, improper wiring, operation outside of  
specification, improper maintenance or repair, or unauthorized modification. Extech  
specifically disclaims any implied warranties or merchantability or fitness for a specific  
purpose and will not be liable for any direct, indirect, incidental or consequential damages.  
Extech's total liability is limited to repair or replacement of the product. The warranty set forth  
above is inclusive and no other warranty, whether written or oral, is expressed or implied.  
ꢃ  
Support line (781) 890-7440  
Technical support: Extension 200; E-mail: support@extech.com  
Repair & Returns: Extension 210; E-mail: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User Guide, Software updates, and other  
Up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451  
Copyright © 2007 Extech Instruments Corporation.  
All rights reserved including the right of reproduction in whole or in part in any form.  
MA150 Ver. 2.0 08/07  
7

相关型号:

MA1505

RS232-to-Wiegand Bidirectional Dual Wiegand Port Converter
ETC

MA15101BAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101BBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101CAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101CBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101DAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101DBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101FAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101FBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101GAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101GBN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA

MA15101JAN

HIGH FREQUENCY CERAMIC CAPACITORS
MURATA