CA250 [EXTECH]

400A AC/DC Current Clamp-on MultiMeter Adaptor; 400A AC / DC电流钳式万用表适配器
CA250
型号: CA250
厂家: EXTECH INSTRUMENTS CORPORATION.    EXTECH INSTRUMENTS CORPORATION.
描述:

400A AC/DC Current Clamp-on MultiMeter Adaptor
400A AC / DC电流钳式万用表适配器

文件: 总1页 (文件大小:99K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
User’s Guide Model CA250  
400A AC/DC Current Clamp-on MultiMeter Adaptor  
Introduction  
Current Measurements  
1. Set the DMM to the AC or DC mV range or to the lowest voltage  
Congratulations on your purchase of the  
Extech CA250 400 Amp AC/DC Clamp-  
On MultiMeter Adaptor. With this clamp  
adaptor, a current can be measured by  
simply clamping around a single  
conductor. The adaptor outputs an mV  
signal that is proportional to the  
measured current and displayed on a  
DMM. Careful use of this device will provide years of reliable service.  
range.  
2. Connect the RED test lead to the DMM '+' Voltage terminal and  
the BLACK lead to the '-' COM terminal.  
3. Set the adaptor to the 40A (AC or DC) or the 400A (AC or DC)  
range.  
4. Press the Jaw Trigger to open the jaw and clamp around a single  
conductor.  
5. The unit will output an AC or DC voltage proportional to the  
measured current. (40A range:10mV/A, 400A range:1mV/A)  
Specifications  
6. Read the voltage on the DMM display and interpret as  
current.(direct mV to A on the 400A range, divide by 10 on the  
40A range)  
Measurement Ranges 0 to 40 Amps AC/DC  
0 to 400 Amps AC/DC  
Adaptor Output  
10mV/Amp on the 0 to 40A range  
1mV/Amp on the 0 to 400A range  
1
4
1. Read mV  
Frequency range  
50/60Hz  
2. Set to AC or DC mV  
2
3. Voltage Input  
EN61010-1 and IEC61010-1 2nd Edition (2001)  
to Category III 600V and Category IV 300V;  
Pollution Degree 2 in accordance with IEC 664  
indoor use.  
5
4. NCV detector  
3
Safety  
6
5. NCV indicator  
6. DC Zero adjust  
Standards  
Accuracy  
C
C
0 to 40A  
DC Zero  
± (2.5% + 0.1A)  
A hysteresis voltage may appear when the clamp is set to the DC  
position. With no conductor in the jaw, adjust the DC Zero adjust until  
the DMM display indicates zero. If the voltage is beyond the range of  
the zero adjust, snap the jaw open and shut several times to clear the  
hysteresis.  
0 to 400A ± (2.8% + 0.5A)  
Jaw size  
1.2" (30mm)  
Operating Conditions  
Storage Conditions  
Battery  
32 to 122oF oF (0 to 50oC) < 70% RH  
-4 to 158oF(-20 to 70oC)<80% RH  
2 – 1.5V “AAA”  
Note: DC current measurements are polarity sensitive. Reverse the  
conductor direction in the jaw to change the polarity.  
Dimensions/Weight  
5.8 x 2.3 x 1.3" (146 x 60 x 32mm);  
8oz. (226g)  
Note: Do not apply voltage to the clamp adaptor’s test leads  
Note: Clamp a single conductor only, do not clamp the hot and neutral  
simultaneously.  
Safety  
Safety Symbols  
This symbol, adjacent to another symbol or terminal,  
indicates the user must refer to the manual for further  
information.  
X
This symbol indicates that double insulation is used.  
Note: The clamp jaws must be fully closed for proper measurements.  
On large conductors or line splitters, make sure there is no gap  
between the upper and lower jaw.  
WARNING: This indicates that a potentially hazardous condition which,  
if not avoided, could result in death or serious injury.  
Safety Precautions  
Non-Contact AC Voltage Measurements  
1. WARNING: Improper use of this meter can cause damage, shock,  
injury or death. Read and understand this manual before operating  
the meter.  
2. Inspect the condition of the test leads and the meter itself for any  
damage before operating the meter. Repair or replace any damage  
before use.  
WARNING: Risk of Electrocution. Before use, always test the  
Voltage Detector on a known live circuit to verify proper operation  
1. Touch the probe tip to the hot conductor or hold next to the hot  
side of the electrical outlet.  
3. Do not use on non-insulated conductors at voltages greater than  
600VAC rms or DC.  
2. If AC voltage is present, the detector LED will illuminate.  
Warranty  
Support line (781) 890-7440  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts  
and workmanship for one year from date of shipment (a six month limited warranty applies to  
sensors and cables). If it should become necessary to return the instrument for service during or  
beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext.  
210 for authorization or visit our website www.extech.com for contact information. A Return  
Authorization (RA) number must be issued before any product is returned to Extech. The sender  
is responsible for shipping charges, freight, insurance and proper packaging to prevent damage  
in transit. This warranty does not apply to defects resulting from action of the user such as  
misuse, improper wiring, operation outside of specification, improper maintenance or repair, or  
unauthorized modification. Extech specifically disclaims any implied warranties or merchantability  
or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or  
consequential damages. Extech's total liability is limited to repair or replacement of the product.  
The warranty set forth above is inclusive and no other warranty, whether written or oral, is  
expressed or implied.  
Technical Support: Extension 200; E-mail: support@extech.com  
Repair & Returns: Extension 210; E-mail: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User’s Guide, Software updates, and other  
up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451  
Copyright © 2009 Extech Instruments Corporation.(A FLIR company)  
All rights reserved including the right of reproduction in whole or in part in any form.  
CA250 V1.0 2/09  

相关型号:

CA250UH10%B

General Purpose Inductor, 50uH, 10%
RCD

CA250UH10%T

General Purpose Inductor, 50uH, 10%
RCD

CA250X1AA4-10

Silicon Controlled Switch
INFINEON

CA2524

Voltage-Mode SMPS Controller
ETC

CA2524E

Analog IC
ETC

CA2524EX

CA2524EX
RENESAS

CA2524F

Analog IC
ETC

CA2524FX

CA2524FX
RENESAS

CA2541

POT 250K OHM 2W CARBON LOG
OHMITE

CA2541E

Potentiometer, 2W, 250000ohm, 1 Turn(s), ROHS COMPLIANT
OHMITE

CA2551C

Mains Power Connector, 200A, Female, Plug
ITT

CA2551D

Mains Power Connector, 250A, Female, Plug
ITT