User's Guide  
Extech AM300  
300A AC Analog Clamp Meter  
Introduction  
Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device  
measure AC Voltage and Current, DC Voltage, and Resistance. This meter is shipped fully  
tested and calibrated and, with proper use, will provide years of reliable service.  
Safety  
International Safety Symbols  
This symbol, adjacent to another symbol or terminal, indicates the user must refer  
to the manual for further information.  
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous  
voltages may be present  
Double insulation  
SAFETY NOTES  
Do not exceed the maximum allowable input range of any function.  
Function  
A AC  
Maximum Input  
300A AC  
V DC, V AC  
600V DC/AC  
Do not apply voltage to meter when resistance function is selected.  
Remove the battery if meter is to be stored for longer than 60 days.  
WARNINGS  
Set function switch to the appropriate position before measuring.  
When measuring volts do not switch to current/resistance modes.  
Do not measure current on a circuit whose voltage exceeds 600V.  
When changing ranges always disconnect the test leads from the circuit under test.  
CAUTIONS  
Improper use of this meter can cause damage, shock, injury or death. Read and  
understand this user manual before operating the meter.  
Always remove the test leads before replacing the battery or fuses.  
Inspect the condition of the test leads and the meter itself for any damage before  
operating the meter. Repair or replace any damage before use.  
Use great care when making measurements if the voltages are greater than 25VAC  
rms or 35VDC. These voltages are considered a shock hazard.  
Always discharge capacitors and remove power from the device under test before  
performing Resistance tests.  
Voltage checks on electrical outlets can be difficult and misleading because of the  
uncertainty of connection to the recessed electrical contacts. Other means should be  
used to ensure that the terminals are not "live".  
If the equipment is used in a manner not specified by the manufacturer, the protection  
provided by the equipment may be impaired.  
2
AM300 V1.1 6/07  
STANDARDS  
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY  
OVERVOLTAGE CATEGORY I  
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in  
which measures are taken to limit the transient overvoltages to an appropriate low level.  
Note – Examples include protected electronic circuits.  
OVERVOLTAGE CATEGORY II  
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be  
supplied from the fixed installation.  
Note – Examples include household, office, and laboratory appliances.  
OVERVOLTAGE CATEGORY III  
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.  
Note – Examples include switches in the fixed installation and some equipment for industrial  
use with permanent connection to the fixed installation.  
OVERVOLTAGE CATEGORY IV  
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.  
Note – Examples include electricity meters and primary over-current protection equipment  
3
AM300 V1.1 6/07  
Description  
Meter Description  
1. Current clamp  
1
2. Clamp opening trigger  
3. Function Selector Switch  
4. Scale Display  
2
3
4
5. POINTER LOCK switch  
6. Meter zero adjust  
5
6
7. Zero ohms adjust  
8. COM negative input jack for black test lead  
9. OHMS positive input jack for red lead  
10. VOLT positive input jack for red lead  
7
9
8
10  
Specifications  
Function  
Ranges  
Accuracy  
AC Current  
(50/60Hz)  
6, 15, 60, 150, and 300A AC  
± 3% of Full Scale for 50/60Hz  
± 3% of Full Scale  
AC Voltage  
(50/60Hz)  
300 and 600V AC  
DC Voltage  
Resistance  
75V DC  
± 3% of Full Scale  
± 3% of Scale Length  
2000(20mid-scale)  
Clamp jaw opening  
Display  
1.5" (38mm) max.  
Analog with Zero Adjustment  
Input Impedance  
240k(75VDC range), 530k(300VAC range, 1MΩ  
(600VAC range),  
AC bandwidth  
Ambient conditions  
Operating Altitude  
Battery  
50 to 60Hz (50 to 400Hz for 15 through 300ACA ranges)  
Temperature 32 - 104oF (0 - 40oC); Relative Humidity <80%  
7000ft. (2000m) maximum.  
One (1) 1.5V ‘AA’ Battery  
Fuse  
0.5A / 250V glass fuse (6mm x 30mm); spare fuse supplied  
Dimensions & Weight  
Safety  
9.0 x 2.8 x 1.5" (230 x 72 x 37mm); 14.7oz. (416g)  
For indoor use and in accordance with the requirements for  
double insulation to IEC1010-1 (2001): EN61010-1 (2001)  
Overvoltage Category II 600V, Pollution Degree 2.  
4
AM300 V1.1 6/07  
Operation  
NOTES: Read and understand all Warning and Caution statements in this operation manual prior to using  
this meter.  
AC Current Measurements  
WARNING: Ensure that the test leads are disconnected from the meter before making current clamp  
measurements.  
1.  
Set the scale to the highest range using the function thumbwheel switch. Step  
down to the lower ranges as necessary in order to keep the reading in the upper  
half of the scale.  
2.  
3.  
4.  
Ensure that the Pointer Lock switch is set to the right-most position so that the  
pointer may freely move.  
Turn the Zero Adjust screw to zero  
the meter display.  
Press the trigger to open jaw. Fully  
enclose only one conductor. For  
optimum results, center the  
conductor in the jaw.  
5.  
The analog display pointer will  
indicate the current reading.  
ü
Ð
AC/DC Voltage Measurements  
1.  
Insert the black test lead into the negative COM terminal and  
the red test lead into the positive V terminal.  
2.  
Set the display to the highest AC or DC Voltage range using  
the thumbwheel switch. Step down to the lower ranges as  
necessary in order to keep the reading in the upper half of  
the scale.  
3.  
Ensure that the Pointer Lock switch is set to the right-most  
position so that the pointer may freely move.  
4.  
5.  
6.  
Turn the Zero Adjust screw to zero the meter display.  
Connect the test leads in parallel to the circuit under test.  
The analog display pointer will indicate the voltage reading.  
V
5
AM300 V1.1 6/07  
Resistance Measurements  
WARNING: To avoid damage to the meter, do not apply voltage to the meter when  
measuring resistance. Ensure that the circuit, device, or component under test is  
disconnected from power before measuring resistance.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Insert the black test lead into the negative COM terminal and the  
red test lead into the OHMS positive terminal.  
Set the display scale to the OHMS position using the thumbwheel  
switch.  
Ensure that the Pointer Lock switch is set to the right-most  
position so that the pointer may freely move.  
With the test leads open, adjust the meter zero so that the pointer  
is over the symbol.  
Touch the test lead tips together and adjust the 0 Ohms adjust  
until the pointer is over the 0 ohms position.  
Touch the test probe tips across the circuit or component under  
test.  
The analog display pointer will indicate the resistance reading.  
W
Pointer Lock Function  
The Pointer Lock switch freezes the pointer’s position and can be used as a ‘data hold’  
feature. This feature is useful in dimly lit or hard to reach locations.  
Maintenance  
WARNING: To avoid electrical shock, disconnect the meter from any circuit and remove the test leads from  
the input terminals before opening the case. Do not operate the meter with an open case.  
Cleaning and Storage  
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or  
solvents. If the meter is not to be used for 60 days or more, remove the battery and store it  
separately.  
Battery and Fuse Replacement  
1. Remove the two (2) Phillips head screws at the rear of the meter.  
2. Carefully open the meter housing.  
3. Replace the 1.5V ‘AA’ battery if necessary  
4. Replace the fuse if necessary with a 0.5A / 250V glass fuse (6mm x 30mm) or  
equivalent. Note that a spare fuse is provided inside the meter housing.  
5. Close the meter and replace the meter screws securely.  
6
AM300 V1.1 6/07  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects  
in parts and workmanship for one year from date of shipment (a six month limited warranty  
applies to sensors and cables). If it should become necessary to return the instrument for  
service during or beyond the warranty period, contact the Customer Service Department at  
(781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact  
information. A Return Authorization (RA) number must be issued before any product is  
returned to Extech. The sender is responsible for shipping charges, freight, insurance and  
proper packaging to prevent damage in transit. This warranty does not apply to defects  
resulting from action of the user such as misuse, improper wiring, operation outside of  
specification, improper maintenance or repair, or unauthorized modification. Extech  
specifically disclaims any implied warranties or merchantability or fitness for a specific  
purpose and will not be liable for any direct, indirect, incidental or consequential damages.  
Extech's total liability is limited to repair or replacement of the product. The warranty set  
forth above is inclusive and no other warranty, whether written or oral, is expressed or  
implied.  
Calibration and Repair Services  
Extech offers repair and calibration services for the products we sell. Extech also  
provides NIST certification for most products. Call the Customer Care Department for  
information on calibration services available for this product. Extech recommends that  
annual calibrations be performed to verify meter performance and accuracy.  
ꢀꢁ  
Support line (781) 890-7440  
Technical Support: Extension 200; E-mail: support@extech.com  
Repair & Returns: Extension 210; E-mail: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User Guide, Software updates, and other  
up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451  
Copyright © 2007 Extech Instruments Corporation  
All rights reserved including the right of reproduction in whole or in part in any form.  
7
AM300 V1.1 6/07  

相关型号:

AM30012

Converter IC
ETC

AM300FB-2405S-UZ

Analog Circuit,
AIMTEC

AM300FB-2412S-UZ

Analog Circuit,
AIMTEC

AM300FB-2424S-UZ

Analog Circuit,
AIMTEC

AM300FB-2448S-UZ

Analog Circuit,
AIMTEC

AM300FB-4805S-UZ

Analog Circuit,
AIMTEC

AM300FB-4812S-UZ

Analog Circuit,
AIMTEC

AM300FB-4828S-UZ

Analog Circuit,
AIMTEC

AM300FB-4848S-UZ

Analog Circuit,
AIMTEC

AM3015

P-CHANNEL ENHANCEMENT MODE POWER MOSFET
AITSEMI

AM3015M8R

P-CHANNEL ENHANCEMENT MODE POWER MOSFET
AITSEMI

AM3015M8VR

P-CHANNEL ENHANCEMENT MODE POWER MOSFET
AITSEMI