475055 [EXTECH]

Digital Force Gauge; 数显推拉力计
475055
型号: 475055
厂家: EXTECH INSTRUMENTS CORPORATION.    EXTECH INSTRUMENTS CORPORATION.
描述:

Digital Force Gauge
数显推拉力计

仪表
文件: 总6页 (文件大小:247K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
User’s Guide  
Models 475055  
Digital Force Gauge  
Introduction  
Congratulations on your purchase of Extech’s Model 475055 Digital Force Gauge that  
measures Tension or Compression (pull/push) to 220 lbs. It features: Peak hold,  
fast/slow response time, positive or reverse display direction, and a separate sensor. An  
RS-232 PC interface provides data acquisition functionality. This meter is shipped fully  
tested and calibrated and with proper use will provide years of reliable service.  
Meter Description  
1
1. Sensor socket  
2. LCD display  
3. Keypad  
2
3
4. Kg/N/lb switch  
5. Off/On/Peak switch  
6. Sensor plug  
7
7. Sensor loop  
8. S-type load sensor  
9. Sensor hook  
10. Mounting Holes with  
screws (included)  
4
5
8
6
9
10  
2
475055 - Version 2.0 - May 2006  
Operation  
Preparation for Measurement  
1. The 475055 automatically determines Tension or Compression (pull/push) force  
during use. Compression displays as a negative value and Tension displays as a  
positive value.  
2. Select units of measure (kilograms, pounds, or Newtons) via the units select  
switch.  
3. Screw in the sensor hook and loop on the load sensor and then connect the sensor  
to the meter via the input jack on top of the meter.  
4. Select FAST (0.2 seconds) or SLOW (0.6 seconds) update rate.  
5. Zero the display before each measurement via the Zero button.  
Note: The sensing head with adapter must be in line with the object being measured.  
Avoid rotating the sensing head. Refer to the Figure 1.  
Figure 1 Correct and Incorrect Angles of Measurement  
Acceptable  
Not Acceptable  
Measurement Mode  
1. Slide the POWER switch to the ON (I)position. Reverse the LCD display if desired  
via the Display Reverse key.  
2. Zero the meter before each measurement.  
3. Touch the adapter to the object being measured in a straight line. Refer to Fig.1.  
4. Begin measurement by applying force (Push or Pull). Read the LCD display.  
5. After completing the measurement, the display will indicate "0.00" if the position  
and angle of the Force Gauge have not changed.  
Note: Be sure to press "ZERO" before taking a new measurement.  
Overrange Indication  
The Model 475055 uses a strain gauge sensor to measure force. Avoid subjecting the  
instrument to forces outside the specified measurement range. The sensitive strain gauge  
can be damaged or otherwise compromised by misuse. When an over-range condition is  
sensed by the meter the LCD displays all dashes.  
Note that the dashes are shown at the top of the LCD (--------) for tension measurements and  
at the bottom of the display (--------) for compression measurements.  
3
475055 - Version 2.0 - May 2006  
Peak Load Measurement  
1. Slide the POWER switch to the PEAK position.  
2. Touch the adapter to the object being measured in a straight line, refer to Fig. 1.  
3. Zero the meter before each measurement.  
4. Begin measurement by applying force (pull or push). The LCD will display the peak  
value, which is the highest reading encountered.  
5. After completing the measurement, the display will hold the peak reading until a  
higher reading is reached or the switch is moved out of the peak hold position.  
Note: Be sure to press "ZERO" before taking a new measurement.  
Fast/Slow selection  
Press the FAST/SLOW key to select the desired display update rate. The “FAST” icon will  
appear in the display when FAST is selected.  
Mounting  
For best results, mount the Digital Force Gauge to a test fixture. Mounting holes are  
provided on the rear of the meter for use with fixtures and test stands.  
Display Backlight  
Pressing the backlight button momentarily will turn on the backlight. After approximately 15  
seconds, it will automatically shut off.  
RS-232 PC Interface  
The 475055 is equipped with a 3.5mm phone jack (meter bottom) for connection to a PC  
for data acquisition purposes. To obtain optional PC interface cabling and Windows® data  
acquisition software (Model 407001A), contact Extech Instruments. Instructions for use are  
provided with the software/cable kit.  
4
475055 - Version 2.0 - May 2006  
Maintenance  
Battery Replacement  
The low battery indication appears as a "LO" on the display when battery voltage is less  
than 6.8V. To replace the battery:  
1. Remove the two screws from the battery compartment cover.  
2. Lift off the battery cover.  
3. Replace with six (6) 1.5V ‘AA’ batteries.  
4. Replace compartment cover and screws.  
Specifications  
Range  
220 lbs, 100kg, 980 Newtons  
Accuracy (23oC)  
±(0.5%rdg + 0.1lbs, 0.1kg or 0.4N)  
0.05lbs, 0.05kg, 0.2 Newtons  
Resolution  
Overload Capacity  
Circuit  
150kg  
Custom LSI microprocessor  
Zero adjust  
Display  
Button for Peak Hold and normal display zero  
5 digit LCD type; Digit height: 0.63” (16 mm)  
Fast mode 0.2 seconds; Slow mode 0.6 seconds  
LCD displays “--------“ for tension measurements and “--------“ for  
compression measurements  
Update Rate  
Over range Indicators  
Zero / Tare Control  
Full Scale Deflection  
Transducer type  
Up to Maximum capacity  
<1mm  
S-type load cell with 2 hooks (thread size: M6 x 1mm ISO)  
and 6.5 ft (2m) cable  
Peak Hold  
Freezes Max reading on display  
RS-232 serial interface with 16-bit data stream output  
32 °F to 122 °F (0°C to 50°C)  
Data Output  
Operating Temperature  
Operating RH  
Power Supply  
Power consumption  
Weight  
Max. 80% Relative Humidity (RH)  
6 x 1.5V ‘AA’ batteries or 9VDC adapter (not included)  
28mA (approx.)  
Meter: 1 lb (450g)  
Sensor: 0.84 lbs (380g)  
Dimensions  
Meter: 8.5 x 3.5 x 1.8” (215 x 90 x 45 mm)  
Sensor with 2 hooks: 4.7 x 2 x 0.7” (130 x 51 x 18 mm)  
Cable length: 6.5 ft. (2m)  
Test Stand Mounting  
Holes  
Located on rear (thread size: M5 x 0.8mm ISO); mounting  
screws included  
5
475055 - Version 2.0 - May 2006  
Calibration and Repair Services  
Extech offers repair and calibration services for the products we sell. Extech also  
provides NIST certification for most products. Call the Customer Service Department for  
information on calibration services available for this product. Extech recommends that  
annual calibrations be performed to verify meter performance and accuracy.  
Warranty  
EXTECH INSTRUMENTS CORPORATION warrants the basic instrument to be free of defects in parts and  
workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it  
should become necessary to return the instrument for service during or beyond the warranty period, contact the  
Customer Service Department at (781) 890-7440 EXTENSION 210 for authorization or visit www.extech.com for  
more information. A Return Authorization (RA) number must be issued before any product is returned to  
Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent  
damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse,  
improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification.  
Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not  
be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or  
replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or  
oral, is expressed or implied.  
Support line (781) 890-7440  
Technical support: Extension 200; E-mail: support@extech.com  
Repair & Returns: Extension 210; E-mail: repair@extech.com  
Product specifications subject to change without notice  
For the latest version of this User’s Guide, Software updates, and other  
up-to-the-minute product information, visit our website: www.extech.com  
Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451  
Copyright © 2006 Extech Instruments Corporation  
All rights reserved including the right of reproduction in whole or in part in any form  
6
475055 - Version 2.0 - May 2006  

相关型号:

47507-0010

PCB Connector, ROHS COMPLIANT
MOLEX

475070010

2.00mm (.079") Pitch Battery Connector with side Fitting Nails
MOLEX

4752

Strip Block for Snap-in Mounting with 4 IEC Appliance Outlets F
SCHURTER

4752.2200

Mains Power Connector, 15A, 250V, Female, Solder Terminal
SCHURTER

4752.2400

Mains Power Connector, 15A, 250V, Female, Solder Terminal
SCHURTER

4752.3000

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.3200

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.3400

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.4000

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.4200

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.4400

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER

4752.5000

Mains Power Connector, 10/15A, 250VAC, Female, Solder Terminal, ROHS COMPLIANT
SCHURTER