380976 [EXTECH]

1000A AC Power Clamp Meter; 1000A电源钳表
380976
型号: 380976
厂家: EXTECH INSTRUMENTS CORPORATION.    EXTECH INSTRUMENTS CORPORATION.
描述:

1000A AC Power Clamp Meter
1000A电源钳表

文件: 总1页 (文件大小:256K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1φ 3φ 1000A AC Power Clamp Meter  
Measures Current, Insulation Resistance, Temperature (Type K) and Power  
Including True Power, Apparent Power, and Reactive Power  
380976 Features:  
Large dual LCD display (9999 count)  
Measures 1f/3fTrue Power (kW), Apparent Power (kVA),  
and Reactive Power (kVAR), plus Horsepower (HP),  
Power Factor, and Phase Angle with Lead/Lag indicator  
AC+DC μA current with 10nA resolution for flame rod  
tests  
Max/Min recording with elapsed time indication  
Auto Detect AC/DC Voltage measurements  
with simultaneous frequency display  
Capacitance to 7000μF with 0.001μF resolution  
High Resistance tests to 100MΩ  
Type K, °C/°F switchable, temperature to 1000ºF  
Diode and Continuity tests  
Auto power off with disable feature  
1.6" (40mm) clamp jaw opening  
Complete with test leads, Type K probe (-58 to 482°F/  
-50 to 250°C), carrying case and 9V battery  
Applications:  
AC Power evaluation  
Motor/Generator installation and repair  
HVAC flame rod tests  
Capture max/min temperature or current values  
Category III rating for industrial measurements  
Function  
True Power (W):  
Max Range / Resolution  
600kW / 10W  
600kVA / 10kVA  
600kVAR/10VAR  
800HP/0.01HP  
-60 to %60° / 0.1°  
1000A / 10mA  
1000μA / 10nA  
600V / 0.1mV  
1000kΩ / 0.1Ω  
100MΩ / 1kΩ  
Basic Accuracy  
±±5% ꢀ0ꢁ  
±5% ꢀ0ꢁ  
±±5% ꢀ0ꢁ  
±±5% ꢀ0ꢁ  
±6°  
±5% ꢀ0ꢁ  
±15% ꢀ0ꢁ  
±15% ꢀ0ꢁ  
±15% 10ꢁ  
±±5% 10ꢁ  
±1.±5% ±ꢁ  
±0.±5% ꢀꢁ  
±15% ꢀ°F  
±15% 1°C  
Apparent Power(kVA):  
Reactive Power (kVAR)  
Horsepower (HP)  
Phase Angle (f):  
AC Current: (Trms):  
uA Current (AC%DC) (Trms):  
AC/DC Voltage: (Trms):  
Resistance (Ω):  
Resistance (MΩ):  
Capacitance:  
Frequency:  
7000μF / 1nF  
40Hz to 1kHz / 0.1Hz  
-±8 to 1000°F / 0.1°F  
-±0 to 900°C / 0.1°C  
9 x 3 x 1.6" (ꢀꢀ8 x 76 x 39mm)  
16.4oz (46±g)  
Temperature (Type K):  
True Power anꢁ Phase Inꢁication for enchanceꢁ  
versatility anꢁ performance.  
Dimensions:  
Weight:  
Ordering Information:  
380976 ..................3-Phase True RMS Power Clamp Meter  
380976-NIST ..........3-Phase True RMS Power Clamp Meter with NIST Certificate  
480172 ..................AC Line Splitter  
Specifications subject to change without notice.  
Copyright © 2008 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.  
07/18/08 - R1  
www.extech.com  

相关型号:

380976-K

Large dual LCD display (9999 count)
EXTECH

380976-K_15

1φ 3φ 1000A AC Power Clamp Meter
EXTECH

380995

Pen MultiMeter with Logic Test
EXTECH

380AA001B08

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B10

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B12

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B14

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B1408M

Connector Accessory,
GLENAIR

380AA001B16

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B18

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR

380AA001B20

EMI/RFI Non-Environmental Backshell with Strain Relief
GLENAIR