XR22414CL48EVB [EXAR]

USB 2.0 4-Port MTT Hub;
XR22414CL48EVB
型号: XR22414CL48EVB
厂家: EXAR CORPORATION    EXAR CORPORATION
描述:

USB 2.0 4-Port MTT Hub

文件: 总13页 (文件大小:565K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
XR22414  
USB 2.0 4-Port MTT Hub  
General Description  
FEATURES  
The XR22414 is a USB 2.0 4-port hub using multiple transaction  
translators (MTT) for highest possible bandwidth capability.  
ꢀ■  
ꢀ■  
ꢀ■  
ꢀ■  
USB 2.0 compliant interface  
Multiple transaction translators (MTT)  
Regulated +3.3V Output Power  
Individual port and hub activity LED  
indicators  
Individual or ganged port power enables  
Individual or global overcurrent sensing  
Single 5V or 3.3V power supply  
Single 12MHz Crystal  
The upstream USB interface has an integrated USB 2.0 PHY and  
device controller that is compliant with both Hi-Speed (480Mbps) and  
Full-Speed (12Mbps) and downstream PHY supporting Hi-Speed,  
Full-Speed and Low-Speed (1.5Mbps) on each of the 4 downstream  
ports.  
ꢀ■  
ꢀ■  
ꢀ■  
ꢀ■  
ꢀ■  
The XR22414 provides two power modes, ganged or individual power  
control as well as global or individual over-current sensing modes.  
48-pin QFN and LQFP package options  
APPLICATIONS  
The XR22414 operates from a single 5V or 3.3V power input. When  
powered by 5V, internal regulators provide a 3.3V output which may  
be connected to VCC33 power input pins as well as external circuitry.  
In turn a second internal regulator provides a 1.8V output from the  
3.3V input. This 1.8V output may be connected to VCC18 power input  
pins. Individual port activity and overall hub activity indicators provide  
status outputs for external LEDs.  
ꢀ■  
USB port expansion  
POS Terminals  
Test Instrumentation  
Factory Automation and Process Controls  
ꢀ■  
ꢀ■  
ꢀ■  
ꢀ■  
Industrial Applications  
Ordering Information - Back Page  
Block Diagram  
USB Host  
Upstream Phy  
XR22414  
Hub Controller  
Port Routing Switch  
TT #1  
TT #2  
TT #3  
TT #4  
Downstream  
Phy #2  
Downstream  
Phy #4  
Downstream  
Phy #3  
Downstream  
Phy #1  
Device #1  
Device #2  
Device #3  
Device #4  
REV1A  
1/13  
XR22414  
Absolute Maximum Ratings  
Operating Conditions  
Stresses beyond the limits listed below may cause  
permanent damage to the device. Exposure to any Absolute  
Maximum Rating condition may affect device reliability and  
lifetime.  
Operating temperature range ........................... 0°C to 70°C  
V
V
supply voltage .........................................4.4V to 5.5V  
CC5  
supply voltage........................................3.0V to 3.6V  
CC33  
V
CC  
V
CC  
V
CC  
5V supply voltage....................................... -0.5V to 6V  
3.3V supply voltage.................................... -0.5V to 4V  
1.8V supply voltage................................. -0.5V to 2.5V  
Input voltage  
(all pins except USBD+, USBD–) ................... -0.3V to 4.0V  
Input voltage (USBD+ and USBD–) ............. -0.3V to 5.75V  
Junction temperature................................................. 125°C  
REV1A  
2/13  
XR22414  
Electrical Characteristics  
Unless otherwise noted: T = 0°C to 70°C; VCC5 = 4.4V to 5.25V or VCC33 = 3.0V to 3.6V.  
A
Conditions  
Symbol  
Min  
Typ  
Max  
2.5  
Units  
Upstream  
Port Speed  
Number of Active  
Downstream Ports  
Downstream Ports  
Device Speed  
Power Consumption DC Supply Current (VCC = VCC5  
)
Suspend  
None  
0.5  
39  
45  
54  
49  
59  
67  
54  
91  
0.5  
27  
32  
42  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
1x Full Speed  
1x High Speed  
1
High Speed  
2x Full Speed  
2
1x Full Speed, 1x High Speed  
2x High Speed  
I
CC  
4x Full Speed  
4
4x High Speed  
Suspend  
2.5  
None  
Full Speed  
1
4
1x Full Speed  
4x Full Speed  
Power Consumption DC Supply Current (VCC = VCC33  
)
Suspend  
None  
0.4  
39  
46  
54  
49  
58  
66  
53  
90  
0.4  
26  
32  
42  
2.5  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
1x Full Speed  
1x High Speed  
1
High Speed  
2x Full Speed  
2
1x Full Speed, 1x High Speed  
2x High Speed  
I
CC  
4x Full Speed  
4
4x High Speed  
Suspend  
2.5  
None  
Full Speed  
1
4
1x Full Speed  
4x Full Speed  
REV1A  
3/13  
XR22414  
Electrical Characteristics (Continued)  
Unless otherwise noted: T = 0°C to 70°C; V  
= 4.4V to 5.25V or V = 3.0V to 3.6V.  
CC33  
A
CC5  
Symbol  
Parameter  
Conditions  
Min  
Typ  
Max  
Units  
Non-USB I/O Pins  
V
V
V
V
Input low voltage  
-0.3  
2.0  
0.8  
5.5  
0.4  
V
V
IL  
Input high voltage  
IH  
Output low voltage  
I
I
= 4mA  
V
OL  
OH  
OL  
OL  
Output high voltage  
Input low leakage current  
Input high leakage current  
Input pin capacitance  
= -4mA  
2.4  
V
I
I
10  
10  
5
μA  
μA  
pF  
IL  
IH  
C
IN  
USB I/O Pins(1)  
3.3V Regulated Power Output  
3V3_OUT  
Output voltage  
Max load current 100mA  
3.0  
3.3  
3.6  
V
NOTE:  
1. See USB 2.0 Specification for USB I/O pins DC Electrical Characteristics.  
Pin Configuration  
BUS_PWR#  
1
2
3
4
5
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
OVC2#  
PWR2#  
VCC18  
PWR3#  
OVC3#  
GND  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
OVC2#  
1
BUS_PWR#  
VBUS_SENSE  
EXT_RST#  
GND  
VBUS_SENSE  
EXT_RST#  
GND  
2
PWR2#  
VCC18  
PWR3#  
OVC3#  
GND  
3
4
5
VCC33  
VCC33  
6
XR22414  
UP_DP  
XR22414  
6
7
UP_DP  
UP_DM  
VCC18  
7
OVC4#  
PWR4#  
VCC18  
GND  
UP_DM  
VCC18  
LQFP48  
QFN48  
OVC4#  
PWR4#  
VCC18  
GND  
8
8
9
REXT  
9
REXT  
10  
11  
12  
VCC33  
10  
11  
12  
VCC33  
XTALOUT  
XTALIN  
1V8_OUT  
GND  
1V8_OUT  
GND  
CPAD  
XTALOUT  
XTALIN  
Top View, QFN48  
Top View, LQFP48  
REV1A  
4/13  
XR22414  
Pin Functions  
Pin Number  
1
Pin Name  
Type Description  
Downstream port 2 over current indicator, active low. If global over-current protection is selected by  
connecting PWR4# to ground, this pin is unused and should be tied to ground.  
OVC2#  
I
Power enable for port 2 downstream device. Asserted if OVC2# input is asserted in individual power  
mode or XR22414 is not configured. Unused when ganged power control mode is selected by  
connecting PWR4# to ground.  
2
3
4
PWR2#  
VCC18  
PWR3#  
O
PWR 1.8V power input  
Power enable for port 3 downstream device. Asserted if OVC3# input is asserted in individual power  
O
mode or XR22414 is not configured. Unused when ganged power control mode is selected by  
connecting PWR4# to ground.  
Downstream port 3 over current indicator, active low. If global over-current protection is selected by  
connecting PWR4# to ground, this pin is unused and should be tied to ground.  
5
6
7
OVC3#  
GND  
I
Ground  
Downstream port 4 over current indicator, active low. If global over-current protection is selected by  
connecting PWR4# to ground, this pin is unused and should be tied to ground.  
OVC4#  
I
Power enable for port 4 downstream device. Asserted if OVC4# input is asserted in individual power  
mode or XR22414 is not configured. If connected to ground, enables Ganged Power Control Mode and  
Global Over-Current Protection mode.  
8
PWR4#  
I/O  
9
VCC18  
GND  
PWR 1.8V power input  
PWR Ground  
10  
11  
XTALOUT  
O
I
12MHz crystal feedback output  
12MHz +/- 50 ppm crystal input with load capacitance rating of 16-20pF. An external 3.3V clock may be  
used instead on on XTALIN leaving XTALOUT unconnected.  
12  
XTALIN  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
VCC33  
DM4  
DP4  
PWR 3.3V power input  
I/O  
I/O  
Downstream port 4 USB D- data  
Downstream port 4 USB D+ data  
GND  
DM3  
DP3  
PWR Ground  
I/O  
I/O  
Downstream port 3 USB D- data  
Downstream port 3 USB D+ data  
VCC33  
DM2  
DP2  
PWR 3.3V power input  
I/O  
I/O  
Downstream port 2 USB D- data  
Downstream port 2 USB D+ data  
GND  
DM1  
DP1  
PWR Ground  
I/O  
I/O  
Downstream port 1 USB D- data  
Downstream port 1 USB D+ data  
GND  
PWR Ground  
1.8V power output from internal 3.3V to 1.8V regulator, may be used to power VCC18 power inputs.  
26  
1V8_OUT  
PWR  
Must be decoupled with minimum of 10uF  
27  
28  
29  
30  
31  
VCC33  
REXT  
PWR 3.3V power input  
I
External bias resistor. Connect 2.7kOhm 1% resistor from this pin to GND  
VCC18  
UP_DM  
UP_DP  
PWR 1.8V power input  
I/O  
I/O  
Upstream port USB D- data  
Upstream port USB D+ data  
REV1A  
5/13  
XR22414  
Pin Number  
Pin Name  
Type Description  
32  
33  
34  
35  
VCC33  
GND  
PWR 3.3V power input  
PWR Ground  
EXT_RST#  
VBUS_SENSE  
I
I
External reset input, active low. Must be asserted for a minimum of 10uS  
Connect to VBUS from USB host. In self-powered mode, indicates presence of host VBUS power  
Bus power indicator, active low. For bus powered mode, connect to ground. For self powered mode,  
connect to logic ‘1’.  
36  
37  
38  
BUS_PWR#  
REG_EN#  
VCC5  
I
I
Active low enable of internal 5V to 3.3V regulator. Connect to logic ‘1’ when XR22414 is powered by  
3.3V.  
5V power to internal 5V to 3.3V regulator. When XR22414 is powered by 3.3V, VCC5 should not be  
connected to 5V, and REG_EN# should be tied to logic ‘1’.  
PWR  
3.3V power output from internal 5V to 3.3V regulator, may be used to power VCC33 power inputs if  
39  
3V3_OUT  
PWR enabled by REG_EN# pin. Must be decoupled with minimum of 10 uF. Leave unconnected if XR22414  
is powered by external 3.3V.  
40  
41  
42  
TEST  
VCC33  
I
Test mode enable. Tie to ground for normal device operation  
PWR 3.3V power input  
LED_CTL  
I/O  
I/O  
LED hub active indicator. May also be used in conjunction with port status LEDs. Refer to Figure 4.  
Port 1 LED Indicator. Max source current 3mA. May be used in conjunction with DRV pin. Refer to  
Figure 4. Connecting LED1 to ground marks downstream port 1 as non-removable device.  
43  
44  
45  
46  
LED1  
LED2  
LED3  
LED4  
Port 2 LED Indicator. Max source current 3mA. May be used in conjunction with DRV pin. Refer to  
Figure 4. Connecting LED2 to ground marks downstream port 2 as non-removable device.  
I/O  
I/O  
I/O  
Port 3 LED Indicator. Max source current 3mA. May be used in conjunction with DRV pin. Refer to  
Figure 4. Connecting LED3 to ground marks downstream port 3 as non-removable device.  
Port 4 LED Indicator. Max source current 3mA. May be used in conjunction with DRV pin. Refer to  
Figure 4. Connecting LED4 to ground marks downstream port 4 as non-removable device.  
Power enable for port 1 downstream device in individual power mode. Asserted if OVC1# input is  
asserted in individual or global power mode or XR22414 is not configured. Used as global power control  
pin if ganged power control mode is selected by connecting PWR4# to ground..  
47  
PWR1#  
O
I
Downstream port 1 over current indicator in individual current-sensing mode, active low. If PWR4# is  
tied to ground, this pin is a global over-current sense input.  
48  
49  
OVC1#  
CPad  
PWR Connect QFN package center pad to PCB ground plane with thermal vias.  
NOTE:  
Type: I = Input, O = Output, I/O = Input/Output, PWR = Power, OD = Open-Drain.  
REV1A  
6/13  
XR22414  
Functional Block Diagram  
USB Host  
XR22414  
Upstream Phy  
Upstream Port Controller  
Hub  
Activity  
Indicator  
Port  
Indicators  
LED  
Controller  
Hub  
Controller  
12  
MHz  
5V to 3.3V  
Regulator  
3.3V to 1.8V  
Regulator  
Oscillator  
PLL (x40)  
480  
MHz  
Power  
Control  
Overcurrent  
Detection  
Downstream Port Controller  
Port Routing Switch  
TT #1  
TT #2  
TT #3  
TT #4  
Downstream  
Phy #2  
Downstream  
Phy #4  
Downstream  
Phy #1  
Downstream  
Phy #3  
Device #1  
Device #2  
Device #3  
Device #4  
REV1A  
7/13  
XR22414  
Applications Information  
Functional Description  
The XR22414 hub has a multiple transaction translator architecture that provides one transaction translator (TT) for each  
of the downstream USB ports. The transaction translators allow the USB 2.0 hub to take incoming high speed packets from  
the USB host on the upstream port and translate these commands, if necessary to full or low speed devices on any of the  
4 downstream ports. The MTT architecture allows for higher bandwidth as the 4 individual ports are not constrained by a  
shared resource.  
USB Interface  
The hub function of the XR22414 supports one configuration and utilizes the following USB endpoints:  
ꢀ■  
Control endpoint  
ꢀ■  
Status change endpoint  
The XR22414 hub may be configured for bus powered mode with a maximum power of 500mA or self-powered mode by  
connecting the BUS_PWR# pin to the appropriate logic state. In bus powered mode, downstream ports are limited to low  
power (100mA or less). When self-powered, downstream devices can draw up to 500mA on each of the four ports.  
USB Vendor ID  
Exar’s USB vendor ID is 0x04E2.  
USB Product ID  
Exar’s USB hub product ID is 0x0414.  
Device Reset  
The XR22414 has both an automatic power-up reset and an external hardware pin reset. Strapping option for ganged power  
enables and global over-current sensing are selected by tying the PWR4# pin to logic ‘0’. This pin is sampled at device reset  
and the resulting option selected is set.  
USB Suspend  
All USB peripheral devices must support the USB suspend mode in bus powered mode. Per USB standard, the XR22414  
device will begin to enter the suspend state if it does not detect any activity, (including Start of Frame or SOF packets) on  
its USB data lines for 3ms. The peripheral device must then reduce power consumption from VBUS power within the next 7  
ms to the allowed limit of 2.5mA for the suspended state. Note that in this context, the “device” is all circuitry (including the  
XR22414) that draws power from the host VBUS. Each attached downstream port is also allowed an additional 2.5mA of  
suspend current. If no devices are connected to the XR22414 downstream ports, the USB host will suspend the hub.  
Individual vs. Ganged Power Control and Global Over-current protection mode  
Ganged power control mode is enabled when PWR4# is tied to ground. In this mode only the PWR1# output pin is used  
for power control and the remaining PWR# pins are unused and should be left unconnected. Global over-current protection  
mode is also enabled when PWR4# is tied to ground. In this mode only OVC1# input pin is used for current sensing and  
the remaining OVC# pins should be connected to ground. Figure 1 depicts ganged power control / global over-current  
protection. Figure 2 depicts individual mode power and over-current modes for ports 1 and 2 (repeat for ports 3 and 4).  
Polymeric PTC  
5V  
2A  
OVC1#  
OVC2#  
OVC3#  
OVC4#  
To VBUS  
input of all  
downstream  
devices  
XR22414  
PWR1#  
PWR2#  
PWR3#  
PWR4#  
Figure 1: Ganged Power Control and Global Over-Current Protection Mode  
REV1A  
8/13  
XR22414  
3.3V  
5V  
To VBUS of  
Port 1  
ENA  
OUTA  
IN  
OVC1#  
OVC2#  
OVC3#  
OVC4#  
FLGA  
FLGB  
ENB  
XRP2528  
GND  
To VBUS of  
Port 2  
OUTB  
RSETB  
RSETA  
Duplicate for  
Port 3 and 4  
XR22414  
PWR1#  
PWR2#  
PWR3#  
PWR4#  
Figure 2: Individual Power Control and Over-Current Protection Mode  
USB Hub Drivers  
All Operating Systems provide a native USB hub device driver for the XR22414 device to operate. No other device drivers  
are necessary for the XR22414.  
Regulated 3.3V Power Output  
The XR22414 internal voltage regulator provides 3.3VDC output power when the device is powered by 5V input. The 3.3V  
output can be utilized by other circuitry. Refer to Electrical Characteristics on page 3 for maximum power capability.  
Downstream Port LED Indicators  
Four port indicator (LED1 - LED4) pins, provide status of connection of downstream devices. Ports with permanently  
connected devices should ground their respective port LED indicator. Ports using LED indicators may configure status LEDs  
in a number of configurations in conjunction with the DRV pin. Figure 3 and Figure 4 show alternate configurations for LED  
status indicators. Green / amber LEDs in Figure 4 are implemented per USB hub specification USB 2.0 spec, chapter 11.  
LED1  
Port 1 device is  
non-removable  
LED2  
Port 2-4 devices are  
removable but port LED  
status is disabled  
LED3  
LED4  
DRV  
XR22414  
Port status LED  
indicators disabled  
Figure 3: Port status LED indicators disabled  
REV1A  
9/13  
XR22414  
Port 1 enabled but does not use port status indicator  
Green  
LED1  
LED2  
LED3  
LED4  
DRV  
Port 2 and 4 devices  
470  
are removable  
with Green/Amber  
LED indicators  
per USB hub  
Amber  
Green  
XR22414  
specification  
470  
Amber  
470  
Hub active indicator (optional)  
Green  
Figure 4: Port status LED indicators enabled dual LED mode  
REV1A  
10/13  
XR22414  
Mechanical Dimensions  
QFN-48  
TOP VIEW  
BOTTOM VIEW  
SIDE VIEW  
TERMINAL DETAILS  
TYPICAL RECOMMENDED LAND PATTERN  
1. All dimensions are in Millimeters  
2. Dimensions and tolerance per Jedec MO-220  
Drawing No.: POD-00000101  
Revision: B  
REV1A  
11/13  
XR22414  
Mechanical Dimensions  
LQFP-48  
TOP VIEW  
DETAIL A  
SIDE VIEW  
TERMINAL DIMENSION  
TYPICAL RECOMMENDED LAND PATTERN  
- Control dimensions are in Millimeters  
- Jedec MS 026  
Drawing No. : POD - 00000096  
Revision: A  
REV1A  
12/13  
XR22414  
Ordering Information(1)  
Part Number  
XR22414CL48TR-F  
XR22414CV48TR-F  
XR22414CL48EVB  
XR22414CV48EVB  
Operating Temperature Range  
Lead-Free  
Yes(2)  
Package  
48-pin QFN  
48-pin LQFP  
Packaging Method  
0°C to +70°C  
0°C to +70°C  
Reel  
Reel  
XR22414 48-pin QFN Evaluation Board  
XR22414 48-pin LQFP Evaluation Board  
NOTE:  
1. Refer to www.exar.com/XR22414 for most up-to-date Ordering Information.  
2. Visit www.exar.com for additional information on Environmental Rating.  
Revision History  
Revision  
1A  
Date  
Description  
February 2017  
Initial Release  
www.exar.com  
48720 Kato Road  
Fremont, CA 94538  
USA  
Tel.: +1 (510) 668-7000  
Fax: +1 (510) 668-7001  
Email: uarttechsupport@exar.com  
Exar Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. Exar Corporation conveys  
no license under any patent or other right and makes no representation that the circuits are free of patent infringement. While the information in this publication has been  
carefully checked, no responsibility, however, is assumed for inaccuracies.  
Exar Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected  
to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless Exar Corporation  
receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of  
Exar Corporation is adequately protected under the circumstances.  
Reproduction, in part or whole, without the prior written consent of Exar Corporation is prohibited. Exar, XR and the XR logo are registered trademarks of Exar Corporation.  
All other trademarks are the property of their respective owners.  
©2016-2017 Exar Corporation  
XR22414_DS_xxxx17  
REV1A  
13/13  

相关型号:

XR22414CL48TR-F

USB 2.0 4-Port MTT Hub
EXAR

XR22414CV48EVB

USB 2.0 4-Port MTT Hub
EXAR

XR22414CV48TR-F

USB 2.0 4-Port MTT Hub
EXAR

XR22414DS

USB 2.0 4-Port MTT Hub
EXAR

XR22417

USB 2.0 7-Port Hub
EXAR

XR22417CV48-F

USB 2.0 7-Port Hub
EXAR

XR22417CV48EVB

USB 2.0 7-Port Hub
EXAR

XR22417CV48TR-F

USB 2.0 7-Port Hub
EXAR

XR22417CV64-F

USB 2.0 7-Port Hub
EXAR

XR22417CV64EVB

USB 2.0 7-Port Hub
EXAR

XR2242

Long Range Timer
EXAR

XR2243

Long Range Timer
EXAR