Features
Close responsively to the human eye spectrum
Light to Current, analog output
Good output linearity across wide illumination range
Low sensitivity variation across various light sources
Operating temperature performance, -40oC to 85oC
Wide supply voltage range, 1.8V to 5.5V
Size : 1.6mm(L)*1.6mm(W)*0.55mm(H)
RoHS compliant, Pb Free and halogen free package
Description
The ALS-PDIC17-77C/TR8 is consisting of a photodiode and a current amplification IC. EVERLIGHT ALS
series product is a good effective solution to the power saving of display backlighting of mobile appliances,
such as the mobile phones, NB and PDAs. Due to the high rejection ratio of infrared radiation, the spectral
response of the ambient light sensor is close to that of human eyes.
Applications
‧
Detection of ambient light to control display backlighting
Mobile devices – mobile phones, PDAs
Computing device – TFT LCD monitor for Notebook computer
Consumer device – TFT LCD TV, Plasma TV, Video camera, Digital camera, Toys
Automatic residential and commercial management
Automatic contrast enhancement for electronic signboard
Ambient light monitoring device for daylight and artificial light
– Street light, CCD/CCTV
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
1
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Package Dimensions
Top View
Bottom View
Unit: mm
Tolerances: ±0.1mm
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
2
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Absolute Maximum Ratings (Ta=25°C)
Parameter
Supply Voltage
Symbol
Rating
Unit
V
cc
-0.5~6.0
0 ~ Vcc-0.8
0 ~ 5
V
V
Output Voltage
Vo
Output Photo Current
IPH
mA
Operating Temperature Range
Storage Temperature Range
Soldering Temperature Range [Note1]
T
opr
-40 ~ +85
-40 ~ +100
260
°C
°C
°C
T
stg
Tsol
Note1: For detail reflow time and the recommended temperature profile, please refer to page 9.
Recommended Operating Conditions (Ta=25°C)
Parameter
Symbol
Min.
Max.
Unit
Operating Temperature
Supply Voltage
T
opr
cc
-40
1.8
+85
5.5
°C
V
V
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
3
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Electrical and Optical Characteristics (Ta=25°C)
Parameter
Symbol Min. Typ. Max. Unit
Test Condition
Vcc = 3V, Ev = 1000Lux
RL = 1kΩ
µA
-
Supply Current
I
cc
480
950
100
[Note2]
V
E
cc=3V
= 0Lux
nA
-
-
Dark Current
ID
v
V
cc=3V; E
v=10Lux
µA
IPH1
2.7
4
5.4
[Note1]
V
V
V
cc=3V; E
cc=3V; E
cc=3V; E
v
v
v
= 100Lux
= 100Lux
=1000Lux
µA
µA
IPH2
IPH3
27
40
48
54
92
[Note1]
[Note2]
[Note1]
Light Current
-
µA
-
-
IPH4
400
1.2
540
1.7
-
-
Photocurrent Ratio
IPH3 / IPH2
V
cc=3V; E
v= 100Lx,
Saturation Output
Voltage
V
[Fig.3]
V
o
2.20 2.35
RL=150KΩ
Peak Sensitivity
Wavelength
nm
-
-
λp
550
µs
µs
µs
µs
-
t
r
11
1000
2000
-
Rise Time
-
t
f
400
Fall Time
Switching
Time
V
cc=3V,RL=5kΩ
[Fig.4]
-
t
d
250
Delay Time
Storage Time
-
-
t
s
35
Note:
1. Fluorescent light (Color Temperature = 6500K) is used as light source. However, White LED is substituted
in mass production.
2. Illuminance by CIE standard illuminant-A 2856K of incandescent lamp.
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
4
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Fig.1 Block Diagram
PDIC17-77C
1.Vcc
Current
Amp
6. Vout
2. GND
3. GND
4. GND
5. GND
Fig.2 Measurement Method of Light Current
Fig.3 Measurement Method of Saturation Output Voltage
Vcc
Vcc
Light
Source
Light
Source
Vout
GND
Vout
GND
PDIC17-77C
PDIC17-77C
I
Fig.4 Switching Time Measurement Method
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
5
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Typical Electrical and Optical Characteristics Curves
Fig.5 Light Current vs. Illuminance
Fig.6 Dark Current vs. Temperature
10000
1000
100
10
Fluorescent light
Incandescent lamp
1
0.1
1
10
100
1000
10000
Illuminance (Lux)
Fig.7 Light current vs. Temperature
Fig.8 Light current vs. Supply Voltage
1.6
1.2
0.8
0.4
0.0
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
VCE = 3V
Ta = 25
EV = 100 Lux
-60
-40
-20
0
20
40
)
60
80
100
2
3
4
5
6
7
Temperature (
Supply voltage (V)
Fig.10 Output Voltage vs. Illuminance
Fig.9 Spectral Response
10
1
Vcc = 3V
Ta = 25
Fluorescent light RL = 5.1 kΩ
Incandescent lamp RL = 5.1 kΩ
Fluorescent light RL = 30 kΩ
Incandescent lamp RL = 30 kΩ
0.1
Fluorescent light RL = 100 kΩ
Incandescent lamp RL = 100 kΩ
0.01
1E-3
1
10
100
1000
10000
Illuminance (Lux)
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
6
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Fig.11 Consumption current vs. Illuminance
Fig.12 Relative consumption current vs. Temperature
1000
1.4
Vcc = 3V
Vcc = 3V
Ta = 25
Ev = 100 Lux
RL= 1kΩ
100
1.2
10
1.0
0.8
0.6
RL = 5.1 kΩ
RL = 50 kΩ
1
RL = 100 kΩ
0.1
1
10
100
1000
10000
-40
-20
0
20
40
60
80
100
Illuminance (Lux)
Temperature (
)
Converting Photocurrent to Voltage
Vcc
Current
Amp
Iph
Vout
CL
R
L
GND
Note:
1. The output voltage (Vout) is the product of photocurrent (IPH) and loading resistor (R
L)
2. A right loading resistor shall be chosen to meet the requirement of maximum ambient light and
output saturation voltage:
V
out(max.)
=
I
out(max.) ×
RL
V
out(saturation)
V
cc 0.6V
3. To avoid 60Hz ripple from fluorescent lamps, we suggest that the time constant must be greater
than
0.5 second:
RL
×
CL
0.5 (empirical data)
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
7
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Recommended method of storage
1. Do not open moisture proof bag before devices are ready to use.
2. Shelf life in sealed bag from the bag seal date:
18 months at 10°C~30°C and < 90% RH.
3. After opening the package, the devices must be stored at 10°C~30°C and ≤ 60%RH,
and used within 1 year (floor life).
4. If the moisture absorbent material (desiccant material) has faded or unopened bag has
exceeded the shelf life or devices (out of bag) have exceeded the floor life, baking
treatment is required.
5. If baking is required, refer to IPC/JEDEC J-STD-033 for bake procedure or recommend
the following conditions:
192 hours at 40°C +5/–0°C and < 5 % RH (reeled/tubed/loose units) or
96 hours at 60°C 5°C and < 5 % RH (reeled/tubed/loose units) or
24 hours at 125°C 5°C, not suitable for reel or tubes.
Recommended Solder Profile
Notice:
(1) Reflow soldering frequency is based on JEDEC-020D.
(2) When soldering, do not put stress on the devices during heating.
(3) After soldering, do not warp the circuit board.
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
8
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Soldering Iron
Each terminal is to go to the tip of soldering iron temperature less than 350 for 3 seconds within once
in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering
of each terminal. Be careful because the damage of the product is often started at the time of the hand
solder.
Repairing
Repair should not be done after the device have been soldered. When repairing is unavoidable, a
double-head soldering iron should be used (as below figure). It should be confirmed beforehand
whether the characteristics of the device will or will not be damaged by repairing.
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
9
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Packing Quantity Specification
3000 PCS/ 1 Reel
Label Format
CPN: Customer’s Production Number
P/N : Production Number
QTY: Packing Quantity
CAT: Ranks
HUE: Peak Wavelength
REF: Reference
LOT No: Lot Number
MADE IN TAIWAN: Production place
MADE IN TAIWAN
Reel Dimensions
Unit: mm
Tolerance: ±0.1mm
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
10
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Tape Dimensions
Progressive direction
Unit: mm
Tolerances: ±0.1mm
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
11
Surface - Mount
Ambient Light Sensor
ALS-PDIC17-77C/TR8
Note:
1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material
change for above specification.
2. When using this product, please observe the absolute maximum ratings and the instructions for
using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any
damage resulting from use of the product which does not comply with the absolute maximum
ratings and the instructions included in these specification sheets.
3. These specification sheets include materials protected under copyright of EVERLIGHT corporation.
Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent.
Everlight Electronics Co., Ltd.
Document No: DLS-0000025 Rev4
http://www.everlight.com
Jun. 20, 2011
12
相关型号:
ALS-PDIC17-77C/TR8
Linear Output Photo IC, 1.60 X 1.60 MM, 0.55 MM HEIGHT, HALOGEN FREE AND ROHS COMPLIANT PACKAGE-6
EVERLIGHT
©2020 ICPDF网 联系我们和版权申明