RN-153.3S/P [ETC]
CONV DC/DC 1.25W 15VIN 3.3VOUT;型号: | RN-153.3S/P |
厂家: | ETC |
描述: | CONV DC/DC 1.25W 15VIN 3.3VOUT |
文件: | 总5页 (文件大小:776K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 1kVDC/1s or 2KVDC/1s basic isolation
• Optional continuous short circuit protected
• UL94V-0 package material
• No heatsink required
Features
DC/DC Converter
Unregulated
Converters
• Efficiency to 85%
RN
Description
1.25 Watt
DIP8
Single Output
The RN series of compact 1.25W single output converters are especially useful when more than 1W of
power is required, but there are space restrictions than make a 2W converter unsuitable. The converter
series feature an industrial ambient temperature operating range of -40°C to +85°C without derating
and up to 100°C ambient temperature with derating. Options include 1kVDC or 2kVDC isolation and
continuous short circuit protection (/P).
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RN-xx3.3S
RN-xx05S
RN-xx07S
RN-xx09S
RN-xx12S
RN-xx15S
RN-xx24S
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3
5
378
250
180
140
104
84
70
2200
1000
1000
1000
470
70-72
72-75
75-80
79-82
80-84
80-85
7
9
12
15
24
470
52
220
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
IEC/EN60950-1 certified
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
Model Numbering
RN- __ S/_
Protection (3)
Isolation Option (4)
Single
Input Voltage
Output Voltage
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/H“ for 2kVDC/1s isolation
or add suffix „/HP“ for continuous short circuit protection and 2kVDC/1s Isolation
Ordering Examples:
RN-0505S/P: 5V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection
RN-0505S/HP: 5V Input Voltage, 5V Output Voltage, Single Output with 2kVDC/1s Isolation and continuous short circuit protection
www.recom-power.com
REV.: 1/2019
ECO-1
RN
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
Minimum Load
10ꢀ
0ꢀ
Internal Operating Frequency
Output Ripple and Noise
50kHz
100kHz
105kHz
20MHz BW
75mVp-p
Efficiency vs. Load
RN-xx05S
RN-xx12S
100
ꢃ0
80
ꢂ0
ꢁ0
50
40
ꢀ0
20
10
0
100
ꢃ0
80
ꢂ0
ꢁ0
50
40
ꢀ0
20
10
0
0505
1205
0512
1212
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
Output Load [%]
Output Load [%]
RN-xx15S
100
ꢃ0
80
ꢂ0
ꢁ0
50
40
ꢀ0
20
10
0
0515
1215
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
Output Load [%]
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Condition
Value
5.0ꢀ max.
low line to high line
3.3Vout
10ꢀ to 100ꢀ load
1.2ꢀ typ. / 1.4ꢀ max.
20.0ꢀ max.
15.0ꢀ max.
10.0ꢀ max.
Load Regulation (5)
5Vout
9, 12, 15, 24Vout
Notes:
Note5: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
continued on next page
www.recom-power.com
REV.: 1/2019
ECO-2
RN
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Deviation vs. Load
RN-xx05S
RN-xx12S
25
20
15
10
5
25
20
15
10
5
0505
1205
0512
1212
0
0
-5
-5
-10
-10
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
Output Load [%]
Output Load [%]
RN-xx15S
25
20
15
10
5
0515
1215
0
-5
-10
0
10 20 ꢀ0 40 50 ꢁ0 ꢂ0 80 ꢃ0 100
Output Load [%]
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
1kVDC
500VAC/60Hz
without suffix
rated for 1 minute
I/P to O/P
Isolation Voltage (6)
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
10GΩ min.
Isolation Resistance
Isolation Capacitance
Insulation Grade
30pF min. / 95pF max.
basic
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 1/2019
ECO-3
RN
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
full load @ free air convection (see graph)
Value
-40°C to +85°C
2000m
Operating Temperature Range
Operating Altitude
Operating Humidity
Pollution Degree
non-condensing
95ꢀ RH max.
PD2
+25°C
+85°C
955 x 103 hours
132 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ free air convection)
100
ꢃ0
80
ꢀ0
ꢁ0
50
40
ꢂ0
20
10
0
-40 -ꢂ0 -20 -10
0
10 20 ꢂ0 40 50 ꢁ0 ꢀ0 80 ꢃ0 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
1602031
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS 2+
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
12.6 x 10.1 x 7.62mm
1.9g typ.
continued on next page
REV.: 1/2019
www.recom-power.com
ECO-4
RN
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Dimension Drawing (mm)
embossed logo
Pinning Information
12.ꢂ0
10.10
Pin #
Single
1
4
5
7
-Vin
+Vin
+Vout
-Vout
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
ꢀ0.5+0.10/0.05
ꢁ.ꢂ2
Recommended Footprint Details
1.00 ꢀ +0.15/-0
ꢁ.ꢂ2
1
4
7
5
Bottom View
Top View
1
4
7
5
5.08
2.54
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
Packaging Quantity
tube
520.0 x 15.0 x 16.0mm
39pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2019
ECO-5
相关型号:
RN-171XVS-I/RM
This document describes the hardware and software setup for Roving Networks RN-XV-RD2 evaluation board, which allows you to evaluate the RN-XV 802.11 b/g module.
ETC
RN-171XVU-I/RM
This document describes the hardware and software setup for Roving Networks RN-XV-RD2 evaluation board, which allows you to evaluate the RN-XV 802.11 b/g module.
ETC
RN-171XVW-I/RM
This document describes the hardware and software setup for Roving Networks RN-XV-RD2 evaluation board, which allows you to evaluate the RN-XV 802.11 b/g module.
ETC
©2020 ICPDF网 联系我们和版权申明