R50A-15-N [ETC]

AC-DC Power Supplies Enclosed type; AC- DC电源封闭式
R50A-15-N
型号: R50A-15-N
厂家: ETC    ETC
描述:

AC-DC Power Supplies Enclosed type
AC- DC电源封闭式

文件: 总12页 (文件大小:501K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ordering information  
AC-DC Power Supplies Enclosed type  
R 10A -5  
-O  
R10A  
1
2
3
4
R
1Series name  
R
2Output wattage  
3Output voltage  
4Optional *2  
G :Low leakage current  
J :Connector type  
N :with Cover  
MODEL  
R10A-3  
6
R10A-5  
10  
R10A-12  
10.8  
R10A-15  
10.5  
R10A-24  
12  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3V 2.0A  
5V 2.0A  
12V 0.9A  
15V 0.7A  
24V 0.5A  
SPECIFICATIONS  
MODEL  
R10A-3  
R10A-5  
R10A-12  
R10A-15  
R10A-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 0.24typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
64typ  
EFFICIENCY[%]  
70typ  
75typ  
76typ  
78typ  
(
) (  
)
INRUSH CURRENT[A] ACIN 100V 20typ Io=100% At cold start  
(
,
)
LEAKAGE CURRENT[mA] 0.5max According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
12  
15  
24  
2.0  
2.0  
0.9  
0.7  
0.5  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
100max ACIN 85V Io=100%  
(
,
,
)
( , ,  
20typ ACIN 100V Io=100% 0 to +50  
C
)
10typ ACIN 85V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
10.8 - 13.2  
13.5 - 16.5  
21.6 - 26.4  
(
)
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically ACIN 100V  
( )  
Works over 115% of rating By zener diode clamping  
OVERVOLTAGE PROTECTION 4.00V min  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Not provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
,
UL60950-1 C-UL Complies with DEN-AN  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
26 68 68mm W H  
X X  
(
)
D /150g max without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Series/Parallel operation with other model is not possible.  
Derating is required when operated with case cover.  
R-2  
R10A  
R
External view  
22max  
(10)  
Name Plate  
LED  
Voltage Adjust  
Name Plate  
M3  
Cover  
Safety Cover  
2-M3  
Mounting Hole  
+
+
-
FG  
AC(L)  
AC(N)  
CN2  
CN1  
-
FG  
AC(L)  
AC(N)  
50t0.5  
3.5  
(13)  
(21)  
I/O Connector  
Mating Connector  
63.5  
CN1  
CN2  
B3P5-VH  
B4P-VH  
VHR-5N  
2-M3  
º3.5  
Name Plate  
Mounting Hole  
VHR-4N  
(Mfr : J.S.T.)  
Weight : 150g or less  
(without cover)  
Cover is optional  
Tolerance :t1  
Dimensions in mm.  
Terminal  
0.2  
26  
t
36  
Chain: SVH-21-P1.1  
Loose: BVH-21-P1.1  
14max  
68  
(Mfr : J.S.T.)  
Connector type  
Barrier strip type  
Mounting torque: 0.6Nm(6.3kgfcm)max  
Performance data  
STATIC CHARACTERISTICS (R10A-5)  
¡
RISE TIME & FALL TIME (R10A-5)  
¡
5.20  
Output Voltage  
5.00  
4.80  
4.60  
4.40  
4.20  
40  
30  
20  
10  
Io=100%  
Ripple  
DC Output  
ACIN 100V Io=100%  
AC Input  
0
50  
60  
70  
80  
90  
100  
110  
120  
130  
20ms/DIV  
60Hz  
INPUT VOLTAGE  
V
OVERCURRENT CHARACTERISTICS (R10A-5)  
¡
DERATING CURVE  
¡
100  
6.0  
5.0  
4.0  
3.0  
2.0  
1.0  
0
2
80  
60  
1
1Convection  
2Forced Air (0.5m3/min)  
40  
20  
0
-10  
0
10  
20  
30  
40[30] 50[40] 60[50] 70[60]  
Please see Electric Characteristics for shaded Ripple,  
Ripple Noise.  
1.0  
2.0  
Inside of  
means with cover  
AMBIENT TEMPERATURE  
ª
OUTPUT CURRENT  
A
R-3  
Ordering information  
AC-DC Power Supplies Enclosed type  
R
15A -5  
-O  
4
R15A  
1
2
3
R
1Series name  
R
2Output wattage  
3Output voltage  
4Optional *2  
C :with Coating  
G :Low leakage current  
J :Connector type  
N :with Cover  
MODEL  
R15A-3  
9
R15A-5  
15  
R15A-9  
R15A-12  
15.6  
R15A-15  
R15A-18  
R15A-24  
16.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
15.3  
15  
15.3  
3V 3.0A  
5V 3A  
9V 1.7A  
12V 1.3A  
15V 1.0A  
18V 0.85A  
24V 0.7A  
SPECIFICATIONS  
MODEL  
R15A-3  
R15A-5  
R15A-9  
R15A-12  
R15A-15  
R15A-18  
R15A-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 0.37typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
EFFICIENCY[%]  
68typ  
72typ  
) (  
73typ  
)
75typ  
75typ  
76typ  
78typ  
(
INRUSH CURRENT[A] ACIN 100V 20typ Io=100% At cold start  
(
,
)
LEAKAGE CURRENT[mA] 0.5max According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
9
12  
15  
18  
24  
3.0  
3.0  
1.7  
1.3  
1.0  
0.85  
0.7  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
36max  
100max  
120max  
160max  
150max  
180max  
90max  
120max  
36max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
72max  
120max  
120max  
160max  
150max  
180max  
180max  
200max  
72max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
100max ACIN 85V Io=100%  
(
,
,
)
( , ,  
20typ ACIN 100V Io=100% 0 to +50  
)
C
10typ ACIN 85V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
8.1 - 9.9  
10.8 - 13.2  
13.5 - 16.5  
16.2 - 19.8  
21.6 - 26.4  
(
)
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically ACIN 100V  
( )  
Works over 115% of rating By zener diode clamping  
OVERVOLTAGE PROTECTION 4.00V min  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Not provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
,
UL60950-1 C-UL Complies with DEN-AN  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
30 69 84mm W H  
X X  
(
)
D / 200g max without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Series/Parallel operation with other model is not possible.  
Derating is required when operated with case cover.  
R-4  
R15A  
R
External view  
LED  
Voltage Adjust  
22max  
M3  
Name Plate  
Cover  
(10)  
Name Plate  
2-M3  
Mounting Hole  
+
+
-
FG  
AC(L)  
AC(N)  
CN2  
CN1  
-
FG  
AC(L)  
AC(N)  
(13.5)  
(23.5)  
Safety Cover  
0.5  
76  
55t  
18.5  
I/O Connector  
Mating Housing  
CN1  
CN2  
B3P5-VH  
B4P-VH  
VHR-5N  
3
2-M3  
Name Plate  
VHR-4N  
3.5  
Mounting Hole  
(Mfr : J.S.T.)  
Weight : 200g or less  
(without cover)  
Terminal  
Cover is optional  
Tolerance :t1  
Dimensions in mm.  
Chain: SVH-21-P1.1  
Loose: BVH-21-P1.1  
5
0.5  
74  
84  
t
(Mfr : J.S.T.)  
Connector type  
14max  
Barrier strip type  
Mounting torque: 0.6Nm(6.3kgfcm)max  
Performance data  
STATIC CHARACTERISTICS (R15A-5)  
¡
RISE TIME & FALL TIME (R15A-5)  
¡
5.20  
Output Voltage  
5.00  
4.80  
4.60  
4.40  
4.20  
40  
30  
20  
10  
Io=100%  
Ripple  
DC Output  
ACIN 100V Io=100%  
AC Input  
0
50  
60  
70  
80  
90  
100  
110  
120  
130  
20ms/DIV  
60Hz  
INPUT VOLTAGE  
V
OVERCURRENT CHARACTERISTICS (R15A-5)  
¡
INRUSH CURRENT (R15A-5)  
¡
6.0  
5.0  
4.0  
3.0  
2.0  
1.0  
0
Frequency  
Load  
Input voltage AC100V  
60Hz  
100%  
1.0  
2.0  
3.0  
4.0  
10ms/DIV  
OUTPUT CURRENT  
A
R-5  
Ordering information  
AC-DC Power Supplies Enclosed type  
R
25A -5  
-O  
4
R25A  
1
2
3
R
1Series name  
R
2Output wattage  
3Output voltage  
4Optional *2  
C :with Coating  
G :Low leakage current  
J :Connector type  
N :with Cover  
MODEL  
R25A-3  
15  
R25A-5  
25  
R25A-9  
R25A-12  
25.2  
R25A-15  
R25A-18  
R25A-24  
26.4  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
25.2  
25.5  
25.2  
3V 5.0A  
5V 5A  
9V 2.8A  
12V 2.1A  
15V 1.7A  
18V 1.4A  
24V 1.1A  
SPECIFICATIONS  
MODEL  
R25A-3  
R25A-5  
R25A-9  
R25A-12  
R25A-15  
R25A-18  
R25A-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 0.58typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
EFFICIENCY[%]  
69typ  
73typ  
) (  
75typ  
)
76typ  
76typ  
77typ  
79typ  
(
INRUSH CURRENT[A] ACIN 100V 20typ Io=100% At cold start  
(
,
)
LEAKAGE CURRENT[mA] 0.5max According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
9
12  
15  
18  
24  
5.0  
5.0  
2.8  
2.1  
1.7  
1.4  
1.1  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
36max  
100max  
120max  
160max  
150max  
180max  
90max  
120max  
36max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
72max  
120max  
120max  
160max  
150max  
180max  
180max  
200max  
72max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
200max ACIN 85V Io=100%  
(
,
,
)
( , ,  
20typ ACIN 100V Io=100% 0 to +50  
)
C
10typ ACIN 85V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
8.1 - 9.9  
10.8 - 13.2  
13.5 - 16.5  
16.2 - 19.8  
21.6 - 26.4  
(
)
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically ACIN 100V  
OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Not provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
,
UL60950-1 C-UL Complies with DEN-AN  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
31 69 104mm W H  
X X  
(
)
D / 250g max without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Series/Parallel operation with other model is not possible.  
Derating is required when operated with case cover.  
R-6  
R25A  
R
External view  
LED  
Voltage Adjust  
22max  
M3  
Name Plate  
Cover  
(10)  
Name Plate  
2-M3  
Mounting Hole  
+
+
-
FG  
AC(L)  
AC(N)  
CN2  
CN1  
-
FG  
AC(L)  
AC(N)  
(13.5)  
(23.5)  
Safety Cover  
0.5  
70  
t
23.5  
I/O Connector  
Mating Housing  
CN1  
CN2  
B3P5-VH  
B4P-VH  
VHR-5N  
96  
Name Plate  
3
3-M3  
VHR-4N  
º3.5  
Mounting Hole  
(Mfr : J.S.T.)  
Weight : 250g or less  
(without cover)  
Terminal  
Cover is optional  
Tolerance :t1  
Dimensions in mm.  
Chain: SVH-21-P1.1  
Loose: BVH-21-P1.1  
9
0.5  
t
83  
90  
(Mfr : J.S.T.)  
Connector type  
0.5  
t
Barrier strip type  
14max  
104  
Mounting torque: 0.6Nm(6.3kgfcm)max  
Performance data  
STATIC CHARACTERISTICS (R25A-5)  
¡
RISE TIME & FALL TIME (R25A-5)  
¡
5.20  
Output Voltage  
5.00  
4.80  
4.60  
4.40  
4.20  
ACIN 100V Io=100%  
40  
30  
20  
10  
Io=100%  
DC Output  
AC Input  
Ripple  
0
50  
60  
70  
80  
90  
100  
110  
120  
130  
20ms/DIV  
60Hz  
INPUT VOLTAGE  
V
OVERCURRENT CHARACTERISTICS (R25A-5)  
¡
INRUSH CURRENT (R25A-5)  
¡
6.0  
5.0  
4.0  
3.0  
2.0  
1.0  
0
Frequency  
Load  
Input voltage AC100V  
60Hz  
100%  
2.0  
4.0  
6.0  
8.0  
10ms/DIV  
OUTPUT CURRENT  
A
R-7  
Ordering information  
AC-DC Power Supplies Enclosed type  
R
50A -5  
-O  
4
R50A  
1
2
3
R
1Series name  
R
2Output wattage  
3Output voltage  
4Optional *2  
C :with Coating  
G :Low leakage current  
J :Connector type  
N :with Cover  
MODEL  
R50A-3  
30  
R50A-5  
50  
R50A-9  
R50A-12  
50.4  
R50A-15  
R50A-18  
R50A-24  
52.8  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
50.4  
51  
50.4  
3V 10A  
5V 10A  
9V 5.6A  
12V 4.2A  
15V 3.4A  
18V 2.8A  
24V 2.2A  
SPECIFICATIONS  
MODEL  
R50A-3  
R50A-5  
R50A-9  
R50A-12  
R50A-15  
R50A-18  
R50A-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 1.1typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
EFFICIENCY[%]  
74typ  
78typ  
) (  
79typ  
)
80typ  
81typ  
82typ  
83typ  
(
INRUSH CURRENT[A] ACIN 100V 30typ Io=100% At cold start  
(
,
)
LEAKAGE CURRENT[mA] 0.5max According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
9
12  
15  
18  
24  
10  
10  
5.6  
4.2  
3.4  
2.8  
2.2  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
36max  
100max  
120max  
160max  
150max  
180max  
90max  
120max  
36max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
72max  
120max  
120max  
160max  
150max  
180max  
180max  
200max  
72max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
200max ACIN 85V Io=100%  
(
,
,
)
( , ,  
20typ ACIN 100V Io=100% 0 to +50  
)
C
10typ ACIN 85V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
8.1 - 9.9  
10.8 - 13.2  
13.5 - 16.5  
16.2 - 19.8  
21.6 - 26.4  
(
)
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically ACIN 100V  
OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Not provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
,
UL60950-1 C-UL Complies with DEN-AN  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
33 85 119mm W H  
X X  
(
)
D / 300g max without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Parallel operation is not possible.  
Derating is required when operated with case cover.  
R-8  
R50A  
R
External view  
17.5max  
LED  
Name Plate  
(10.5)  
Voltage Adjust  
Name  
Plate  
Cover  
+
2-M3  
Mounting Hole  
+
-
CN2  
CN1  
-
FG  
FG  
AC(L)  
AC(N)  
M3  
AC(L)  
AC(N)  
Safety  
Cover  
(14)  
(24)  
0.5  
70  
t
23  
I/O Connector  
Mating Housing  
CN1  
CN2  
B3P5-VH  
B4P-VH  
VHR-5N  
3
111  
2-M3  
Mounting Hole  
VHR-4N  
º3.5  
Name Plate  
(Mfr : J.S.T.)  
Weight : 300g or less  
(without cover)  
Terminal  
Cover is optional  
Tolerance :t1  
Dimensions in mm.  
Chain: SVH-21-P1.1  
Loose: BVH-21-P1.1  
0.5  
100  
t
14  
max  
14  
(Mfr : J.S.T.)  
Connector type  
119  
Barrier strip type  
Mounting torque: 0.49N•m(5.0kgf•cm)max  
Performance data  
STATIC CHARACTERISTICS (R50A-5)  
¡
RISE TIME & FALL TIME (R50A-5)  
¡
5.40  
80  
70  
60  
50  
40  
30  
20  
5.20  
ACIN 100V Io=100%  
Output Voltage  
Io=100%  
5.00  
4.80  
4.60  
4.40  
4.20  
0
Ripple  
DC Output  
AC Input  
50  
60  
70  
80  
90  
100  
110  
120  
130  
20ms/DIV  
60Hz  
INPUT VOLTAGE  
V
OVERCURRENT CHARACTERISTICS (R50A-5)  
¡
INRUSH CURRENT (R50A-5)  
¡
6.0  
5.0  
4.0  
3.0  
2.0  
1.0  
0
Frequency  
Load  
Input voltage AC100V  
60Hz  
100%  
5
10  
15  
10ms/DIV  
OUTPUT CURRENT  
A
R-9  
Ordering information  
AC-DC Power Supplies Enclosed type  
R
100  
U
-5  
-O  
5
R100U  
1
2
3
4
R
1Series name  
R
2Output wattage  
3UL recognized,TuV  
approved,CSA certified  
4Output voltage  
5Optional *2  
C :with Coating  
G :Low leakage current  
N :with Cover  
MODEL  
R100U-3  
60  
R100U-5  
100  
R100U-9  
103.5  
R100U-12  
102  
R100U-15  
105  
R100U-18  
100.8  
R100U-24  
108  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3V 20A  
5V 20A  
9V 11.5A  
12V 8.5A  
15V 7A  
18V 5.6A  
24V 4.5A  
SPECIFICATIONS  
MODEL  
R100U-3  
R100U-5  
R100U-9  
R100U-12  
R100U-15  
R100U-18  
R100U-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 2.8typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
EFFICIENCY[%]  
75typ  
79typ  
80typ  
82typ  
83typ  
84typ  
85typ  
(
)
INRUSH CURRENT[A] ACIN 100V 15typ Io=100%  
(
,
,
)
LEAKAGE CURRENT[mA] 0.5max 60Hz According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
9
12  
15  
18  
24  
20  
20  
11.5  
8.5  
7
5.6  
4.5  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
36max  
100max  
120max  
160max  
150max  
180max  
90max  
120max  
36max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
72max  
120max  
120max  
160max  
150max  
180max  
180max  
200max  
72max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
200max ACIN 85V Io=100%  
(
,
,
)
( , ,  
10typ ACIN 85V Io=100% 0 to +50  
)
C
20typ ACIN 100V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
8.1 - 9.9  
10.8 - 13.2  
13.5 - 16.5  
16.2 - 19.8  
21.6 - 26.4  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
, ,  
UL60950-1 CSA C22.2 No.60950-1 EN60950-1 Complies with DEN-AN and IEC60950-1  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
34.5 93 160mm W H  
X X  
(
)
D / 600gmax without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Parallel operation with other model is not possible.  
Derating is required when operated with case cover.  
R-10  
R100U  
R
External view  
Dimensions in mm.  
Mounting torque: 1.2Nm(12.8kgfcm)max  
Performance data  
(
)
(
)
STATIC CHARACTERISTICS R100U-5  
RISE TIME & FALL TIME R100U-5  
¡
¡
(
)
OVERCURRENT CHARACTERISTICS R100U-5  
DERATING CURVE  
¡
¡
R-11  
Ordering information  
AC-DC Power Supplies Enclosed type  
R
150  
U
-5  
-O  
5
R150U  
1
2
3
4
R
1Series name  
R
2Output wattage  
3UL recognized,TuV  
approved,CSA certified  
4Output voltage  
5Optional *2  
C :with Coating  
G :Low leakage current  
N :with Cover  
MODEL  
R150U-3  
90  
R150U-5  
150  
R150U-9  
153  
R150U-12  
156  
R150U-15  
150  
R150U-18  
153  
R150U-24  
156  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
3V 30A  
5V 30A  
9V 17A  
12V 13A  
15V 10A  
18V 8.5A  
24V 6.5A  
SPECIFICATIONS  
MODEL  
R150U-3  
R150U-5  
R150U-9  
R150U-12  
R150U-15  
R150U-18  
R150U-24  
VOLTAGE[V]  
CURRENT[A]  
AC85 - 132 1 or DC110 - 170  
f
(
)
ACIN 100V 4.2typ Io=100%  
FREQUENCY[Hz]  
INPUT  
47 - 440 or DC  
EFFICIENCY[%]  
74typ  
78typ  
79typ  
80typ  
82typ  
83typ  
84typ  
(
)
INRUSH CURRENT[A] ACIN 100V 15typ Io=100%  
(
,
,
)
LEAKAGE CURRENT[mA] 0.5max 60Hz According to UL CSA and DEN-AN  
VOLTAGE[V]  
CURRENT[A]  
3
5
9
12  
13  
15  
18  
24  
30  
30  
17  
10  
8.5  
6.5  
LINE REGULATION[mV] 20max  
LOAD REGULATION[mV] 40max  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
60max  
20max  
36max  
100max  
120max  
160max  
150max  
180max  
90max  
120max  
36max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
72max  
120max  
120max  
160max  
150max  
180max  
180max  
200max  
72max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
0 to +50 80max  
C
RIPPLE[mVp-p]  
-10 - 0 140max  
C
0 to +50 120max  
C
OUTPUT  
RIPPLE NOISE[mVp-p]  
-10 - 0 160max  
C
0 to +50 50max  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
1
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
200max ACIN 85V Io=100%  
(
,
,
)
( , ,  
10typ ACIN 85V Io=100% 0 to +50  
)
C
20typ ACIN 100V Io=100% 0 to +50  
C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6  
4.5 - 5.5  
8.1 - 9.9  
10.8 - 13.2  
13.5 - 16.5  
16.2 - 19.8  
21.6 - 26.4  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating  
PROTECTION  
(
)
CIRCUIT AND OPERATING INDICATION LED Green  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
Provided  
Not provided  
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
,
, , , (  
AC2 000V 1minute Cutoff current = 10mA max DC500V 50M min At Room Temperature  
W
ISOLATION INPUT-FG COVER  
,
,
,
(
)
OUTPUT-FG COVER  
AC500V 1minute Cutoff current = 100mA max DC500V 50M min At Room Temperature  
W
,
,
,
(
) (  
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max  
C
,
(
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
SAFETY AND  
NOISE  
, ,  
UL60950-1 CSA C22.2 No.60950-1 EN60950-1 Complies with DEN-AN and IEC60950-1  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
Complies with FCC-B VCCI-B  
REGULATIONS  
( )  
44.5 93 175mm W H  
X X  
(
)
D / 900g max without cover  
X
X
OTHERS  
Convection  
*1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.  
*2 Please contact us about safety approvals for the model with option.  
*
*
*
Avoid prolonged use under over-load.  
Parallel operation with other model is not possible.  
Derating is required when operated with case cover.  
R-12  
R150U  
R
External view  
Performance data  
(
)
(
)
STATIC CHARACTERISTICS R150U-5  
RISE TIME & FALL TIME R150U-5  
¡
¡
(
)
OVERCURRENT CHARACTERISTICS R150U-5  
DERATING CURVE  
¡
¡
R-13  

相关型号:

R50E

Trimmer Potentiometers SMD Open Type 2mm Size PVZ2/PVA2 Series
MURATA

R50XT-24J102

Fixed Resistor, Carbon Film, 0.5W, 1000ohm, 350V, 5% +/-Tol, Through Hole Mount, AXIAL LEADED
ROHM

R50XT-24J104

Fixed Resistor, Carbon Film, 0.5W, 100000ohm, 350V, 5% +/-Tol, Through Hole Mount, AXIAL LEADED
ROHM

R50XT-24J105

Fixed Resistor, Carbon Film, 0.5W, 1000000ohm, 350V, 5% +/-Tol, Through Hole Mount, AXIAL LEADED
ROHM

R50XT-24J112

Fixed Resistor, Carbon Film, 0.5W, 1100ohm, 350V, 5% +/-Tol, Through Hole Mount, AXIAL LEADED
ROHM

R50XT-24J114

Fixed Resistor, Carbon Film, 0.5W, 110000ohm, 350V, 5% +/-Tol, Through Hole Mount, AXIAL LEADED
ROHM

R51-1D40-12

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE

R51-1D40-12F

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE

R51-1D40-12FW

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE

R51-1D40-24

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE

R51-1D40-24F

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE

R51-1D40-24FW

50 Amp and 70 Amp, SPST and SPDT Relays for use in Automotive/Marine/Tractor/Lawn Mower/Rec. Vehicles/Golf Cart Applications.
NTE