PXL-10.115 [ETC]
RELAY PROCESS THRESHOLD ; 继电器的进程阈值\n![PXL-10.115](http://pdffile.icpdf.com/pdf1/p00002/img/icpdf/PXL-1_9725_icpdf.jpg)
型号: | PXL-10.115 |
厂家: | ![]() |
描述: | RELAY PROCESS THRESHOLD
|
文件: | 总2页 (文件大小:50K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Signal Converters & Isolators
Threshold Relay PXL-10
DESCRIPTION
OPERATION
A threshold relay for the monitoring or control of common types of
process signals. The process signal to be monitored is selected on
the front panel and the threshold value is also adjusted via a setpoint
potentiometer on the front of the relay. As the input signal attains the
threshold plus the hysteresis the output relay energises. When the
input signal drops and passes the threshold, minus hysteresis, the
relay de-energises. The hysteresis is adjustable on the front, ±0,5
- 20%.
Output signal
supply
hysteresis
setpoint
By strapping 2 terminals, the relay can be inverted.
A red LED indicates if the relay is energised.
There is also a latch function where the relay after energising will
remain energised, regardless of input, until the latch jumper or the
operating voltage is disconnected. Typically used in safety circuits.
inv
latch
Features
• Input 0 - 5V/0-10V/-10-+10VDC/0-20/4-20mA in one version.
• Adjustable setpoint.
• Hysteresis adjustable ±0,5-20%.
• Automatic locking (Latch).
inv
• Inversion of relay function.
• Output SPDT.
• Operating voltage 24VDC, 24/115VAC or 24/230VAC.
VERSIONS/ORDERING CODES
MECHANICAL DIMENSIONS
Type:
PXL-10
230
Threshold relay
PXL-10
Supply voltage
24V DC
115V / 24V AC
230V AC / 24V AC
924
115
230
104.0 mm
22.5 mm
Export:
Tel:
Fax:
United Kingdom:
Germany:
+45 46 74 00 00
+45 46 75 73 36
Tel:
+44 020 8546 4283
+44 020 8547 3628
Tel:
+49 208 46954-0
+49 208 46954-50
Fax:
Fax:
E-mail: bc@brodersencontrols.com
E-mail: bcs@brodersen.co.uk
E-mail: ba@brodersen.de
74
Signal Converters & Isolators
Threshold Relay PXL-10
TECHNICALDATA
WIRING DIAGRAM
Input
0
-
I
IN
VIN
+
Input:
+
Input signal
0-5V DC
0-10V DC
-10-+10V DC
0-20mA DC
4-20mA DC
Impedance
>100kOhm
>100kOhm
>100kOhm
50 Ohm
A1
15
Y2
Z3
Y3
Umax = 50Vp-p
MAX = 50mA
Latch
active
Y1
15
I
Inversion
relay
µ
50 Ohm
Coding:
Relay inverter: Z1-Z2
Latching:
16 18
A3
16
Z1
18
Z2
A2
Selected via switches on the front panel.
Z1-Z3
Hysteresis:
Response time:
±0,5-20% of range, adjustable.
Time constant (τ = approx. 0,3s,
worst case of response time max. 5xτ).
L(115/230) L(24V)
+ (24V)
N
-(0V)
AC supply
DC supply
Upper critical frequency 30 Hz.
Output:
SPDT relay:
Contact material, AgNi 0,15 with hardened
gold plating Au.
SPECIFICATIONS:
Max load AC:
8A/240V AC (cos ϕ=1)
Max. breaking capacity2000VA.
Inductive load. See fig. 1.
8A/24V DC.
PXL-10 is designed and developed with regard to relevant specifi-
cations:
• EN60204-1 / VDE0113 electrical material on machines.
Max load DC:
Max.breakingcapacity50-270W. Seefig. 2.
• VDE0110 / IEC664 Isolation specifications/creepage and clear-
Max. in rush
current:
Min. in rush
current:
Frequency :
Life span:
ance
distances.
15A (max. 4s/duty cycle less than 10%)
• Electrical safety in accordance with EN61010.
• IEC414 Safety regulations for control and monitoring equipment.
10mA, 24V DC.
• EMC:
Emission EN50081-1
Immunity EN50082-2
Max. 1000 operations pr. hour.
Mech. Min. 3 x 107 operations.
Elect. Min. 1x 105 operations with full load.
<20ms.
• Humidity in accordance with IEC68-2-3; RH=95%, 40°C.
• Vibration in accordance with IEC68-2-6:
• Shock when mounted, in accordance with IEC68-2-27.
Delay:
PXL-10 is CE-marked in accordance with EMC-and the Low Voltage
Directive.
Supply voltage:
Versions:
924 = 24V DC (20,4-27,6)V DC
115 = 24/115V AC (20,4-27,6/98-132)V AC
230 = 24/230V AC (20,4-27,6/196-264)V
AC
OUTPUT LOAD DIAGRAMS
Net frequency:
Consumption:
45-65Hz
AC; 3VA
DC; 2W
Fig. 1
1,0
Generaldata:
Ambienttemperature:-20to55°C.
0,9
Storage temperature:-40 to 80°C.
0,8
0,7
Mounting:
Terminals:
35mm DIN-rail (EN50022).
Screw terminals with dual compartment.
Terminal screws are combined
crosshead/slotted.
0,6
0,5
eRudinfacrto
Up to 2 x 2,5mm2 wire (2 x 1,5mm2
inc. ferrule).
0,4
0,2
0,4
0,6
0,8
1,0
ϕ
Recommendedtorque,0,5Nm.,
max. 0,7 Nm. (VDE0609-1).
Terminal identification in accordance with
DIN46199/EN50005.
cos
Fig. 2
U [V]
300
Indicators:
Green LED = operating voltage.
Red LED = relay switched on.
IP20.
3,75kVAC (1 min.) between input,
supply and relay output (EN60950).
Noryl (GE), UL94V1.
200
100
50
Protection:
Electric isolation:
20
Housing:
Terminal block:
Weight:
Noryl (GE), UL94V0.
180 g.
0,1 0,2 0,5
1,0
2,0
5,0
8,0 I [A]
Export:
United Kingdom:
Germany:
Tel:
Fax:
+45 46 74 00 00
+45 46 75 73 36
Tel:
Fax:
+44 020 8546 4283
+44 020 8547 3628
Tel:
Fax:
+49 208 46954-0
+49 208 46954-50
E-mail: bc@brodersencontrols.com
E-mail: bcs@brodersen.co.uk
E-mail: ba@brodersen.de
75
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00367/img/page/PXE1110CDM-G_2243121_files/PXE1110CDM-G_2243121_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00367/img/page/PXE1110CDM-G_2243121_files/PXE1110CDM-G_2243121_2.jpg)
PXM1310CDM-G003
The Infineon Technologies memory digital controllers provide intelligent power for DDR3/DDR4 applications. Command and monitor functions are controlled through the Intel SVID interface which supports 5mV/step VID table, power states (PS), and VR Data & Configuration Register requirements. Infineon’s memory controllers utilize digital technology to implement all control functions, providing the ultimate system solution in terms of flexibility and stability.
INFINEON
©2020 ICPDF网 联系我们和版权申明