NP3E [ETC]
NEUTRAL BLOCK SWITCHED ; 中性BLOCK SWITCHED\n型号: | NP3E |
厂家: | ETC |
描述: | NEUTRAL BLOCK SWITCHED
|
文件: | 总85页 (文件大小:2915K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Moeller HPL0211-2001/2002
07/000
T Rotary Switches, P Switch-Disconnectors
Moeller HPL0211-2001/2002
07/001
T Rotary Switches, P Switch-Disconnectors
Overview
T rotary switches, P switch-disconnectors
TM mini rotary switches
Page
Page
Overview of functions
Technical overview
07/002
Overview of functions
Technical overview
07/002
07/004
07/006
07/010
07/004
07/072
07/010
System overview
System overview
Key to type references, modular system
Key to type references, modular system
On-Off switches
Main switches
On-Off switches
Control circuit isolators
On-Off switches
07/012
07/018
07/024
07/074
07/074
On-Off switches
Safety switches
Control switches
Control switches
Changeover switches
Reversing switches
Step switches
Changeover switches
Reversing switches
Star-delta switches
Multi-speed switches
Step switches
07/026
07/032
07/032
07/034
07/036
07/040
07/042
07/044
07/046
07/046
07/046
07/048
07/075
07/082
07/077
07/081
07/076
07/081
07/082
07/080
On-Off switches
Hand/Auto switches
On-Off switches, spring-return
Coding switches
On-Off switches
Hand/Auto switches
On-Off switches, spring-return
Universal control switches
Coding switches
Group switches
Series switches
Instrument selector switches
Switches with locking arrangements
Panic switches
07/050
07/050
07/052
On-Off switches
Hand/Auto switches
Accessories
Accessories
Front plates
07/054
07/058
07/060
Key operation
07/083
07/088
Key operation
Additional accessories
Non-standard switches
T0 rotary switches
Non-standard switches
07/084
07/085
07/086
07/087
07/088
TM mini rotary switches
T3 rotary switches
T5B rotary switches
T5 rotary switches
Bulk packaged switches
Technical data
07/090
07/096
07/110
Technical data
07/095
07/108
07/110
Dimensions
Dimensions
Ordering of non-standard switches
Ordering of non-standard switches
For other standard contact sequences, see catalogue K115
Moeller HPL0211-2001/2002
07/002
T Rotary Switches, P Switch-Disconnectors
Overview of Functions
Function
Flush mounting
.../E...
Centre mounting Surface
Distribution
board mounting
.../IVS...
Rear mounting
.../Z...
.../EZ...
mounting
.../I...
On-Off switches
Main switches
a 07/012
a 07/014
a 07/013
a 07/015
a 07/013
a 07/015
Maintenance switches
For use as Emergency-Stop devices1)
Main switches
Maintenance switches
with auxiliary contacts
For use as Emergency-Stop devices1)
Main switches
a 07/013
a 07/015
a 07/013
a 07/015
a 07/013
a 07/015
Maintenance switches
Main switches
Maintenance switches
with auxiliary contacts
On-Off switches with black thumb-grip
a 07/016
a 07/074
a 07/019
a 07/074
a 07/019
a 07/019
a 07/019
a 07/021
On-Off switches with black thumb-grip
With auxiliary contacts
a 07/020
a 07/022
a 07/074
a 07/021
a 07/021
a 07/023
a 07/021
a 07/023
On-Off switches
For use as Emergency-Stop devices1)
Control circuit isolators
Safety switches 25 – 100 A
a 07/024
a 07/025
For use as Emergency-Stop devices1)
Safety switches 25 – 100 A
Notes
1) To IEC/EN 60 204-1;
With red thumb-grip and yellow front plate
Moeller HPL0211-2001/2002
07/003
T Rotary Switches, P Switch-Disconnectors
Overview of Functions
Function
Flush mounting
.../E...
Centre mounting Surface
Distribution
board mounting
.../IVS...
Rear mounting
.../Z...
.../EZ...
mounting
.../I...
Control switches
Changeover switches
a 07/026
a 07/075
a 07/027
a 07/075
a 07/027
a 07/033
a 07/027
a 07/033
a 07/027
a 07/033
Mains transfer-, group switches
Reversing switches
a 07/032
a 07/082
a 07/033
a 07/082
Star-delta switches
Multi-speed switches
Step switches
a 07/032
a 07/034
a 07/033
a 07/035
a 07/033
a 07/035
a 07/037
a 07/033
a 07/035
a 07/037
a 07/033
a 07/035
a 07/037
a 07/036
a 07/077
a 07/036
a 07/077
On-Off switches, changeover switches
Hand/Auto switches
a 07/040
a 07/081
a 07/040
a 07/081
a 07/041
a 07/043
a 07/045
a 07/041
a 07/043
a 07/045
a 07/041
a 07/043
a 07/045
a 07/042
a 07/076
a 07/042
a 07/076
Spring-return switches
a 07/044
a 07/081
a 07/044
a 07/081
Universal control switches
Coding switches
a 07/046
a 07/046
a 07/047
a 07/047
a 07/047
a 07/047
a 07/047
a 07/047
a 07/046
a 07/082
a 07/046
a 07/082
Series switches
a 07/046
a 07/048
a 07/048
a 07/050
a 07/046
a 07/048
a 07/048
a 07/047
a 07/049
a 07/049
a 07/051
a 07/047
a 07/049
a 07/049
a 07/047
a 07/049
a 07/049
a 07/051
Instrument selector switches
(voltage)
Instrument selector switches
(current)
Switches with locking arrangements
Moeller HPL0211-2001/2002
07/004
T Rotary Switches, P Switch-Disconnectors
Technical Overview
Switch size
TM
1.5
2.2
–
T0
3
T3
6.5
12
15
T5B
15
Three-phase motor rating
AC-3
220 – 240 V
kW
380 – 440 V kW
4
22
22
690 V
kW
kW
4
AC-23
220 – 240 V
1.8
3
3.5
6.5
–
7.5
13
–
18.5
22
380 – 440 V kW
690 V kW
–
22
Rated operational current
AC-21
AC-15
380 – 440 V 3~ A
10
20
6
32
10
6
63
16
6
220 – 240 V
380 – 415 V
A
A
A
2.5
1.5
10
4
Rated uninterrupted current
20
32
63
Mounting form
Type
Degree of protection
Surface mounting1)
.../I...
IP65
–
–
–
–
K
–
K
–
K
–
.../I 45/...
.../I 48/...
.../ST/...
–
–
–
K
K
K
Surface mounting main switch1)
.../I.../SVB...
.../ST/SVB...
IP65
–
–
K
K
K
K
K
K
Flush mounting
.../E...
Front IP65
K
K
K
K
Flush mounting main switch/flush mounting control
circuit isolator
.../EA/SVB...
TM.../E/SVB
Front IP65
Front IP65
–
K
K
K
K
–
–
–
Centre mounting
.../EZ...
–
K
K
–
–
TM.../EZ
K
–
–
Rear mounting
.../Z...
Front IP65
Front IP65
–
–
K
K
K
K
K
K
Rear mounting main switches
.../V/SVB...
Service distribution board mounting
.../IVS...
Front IP30
K
K
–
–
1)
Notes
Enclosures for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
07/005
T Rotary Switches, P Switch-Disconnectors
Technical Overview
T5
T6-2
22
T6-3-8212
T6-160-6
T8-3-8342
T8-3-8212
P1
P3
15
30
30
18.5
30
22
37
22
22
45
22
37
55
37
37
55
37
5.5
7.5
7.5
7.5
13
15
22
37
37
37
30
22
18.5
30
37
45
30
37
45
30
37
55
30
75
75
7
8.5
15
18.5
37
30
50
75
132
37
132
37
13
11
30
18.5
30
100
16
125
–
125
–
160
–
315
–
315
–
25
–
32
–
63
–
100
–
6
–
–
–
–
–
–
–
–
–
100
125
125
160
315
315
25
32
63
100
K
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
K
–
K
–
K
–
–
–
K
–
–
–
K
–
K
K
K
K
–
–
–
–
–
–
–
–
–
–
K
K
K
K
K
K
K
–
–
K
K
K
K
K
–
–
–
–
–
–
K
K
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
K
–
–
–
–
–
b
–
–
–
–
–
–
–
K
K
K
K
K
K
K
K
–
–
–
–
–
–
K
K
Moeller HPL0211-2001/2002
07/006
T Rotary Switches
System Overview
T0, T3, T5B, T5 On-Off switches
2
1
3
4
10
10
5
9
9
8
8
7
6
7
6
T0, T3, T5B, T5 control switches
1
2
3
4
10
10
9
9
Moeller HPL0211-2001/2002
07/007
T Rotary Switches
System Overview
Service distribution board mounting
(.../IVS)
1
Centre mounting (.../EZ)
3
Main switch (assembly kit)
6
for use as Emergency-Stop device
Front IP65
To IEC/EN 60 204-1
Front IP30
Mounting in ∅ 22.3 fixing hole
to IEC/EN 60 947-5-1
For snap fitting to
EN 50 022 top-hat rail
With red rotary handle and yellow locking
collar
Centre fixing permits installation by one
fitter
Flush mounting
– service distribution boards: up to
3 contact units (45 mm mounting depth)
– control panels: up to 11 contact units
Lockable in the 0 (Off) position
a Page 07/019
a Page 07/062
a Page 07/019
Surface mounting (.../I...)
IP65
4
Main switch (assembly kit)
7
8
Black rotary handle and locking collar
Lockable in the 0 (Off) position
With PE terminal
Rear mounting (.../Z)
2
Enclosures designed for metric cable
glands to EN 50 262
Front IP65
Secured by screw fixing or snap fitting
(T0 or T3)
a Page 07/062
a Page 07/019
For snap fitting to
EN 50 022 top-hat rail
Coupling drive in door or cover
Connection from the front
Thumb-grip
for use in Emergency-Stop devices
Surface mounting main switches
(.../I...)
4
To IEC/EN 60 204-1
IP65
a Page 07/019
Red thumb-grip with yellow front plate
To IEC/EN 60 204
and IEC/EN 60 947-3,
up to 8 contacts for T0..., and up to 10
contacts for T3
a Page 07/062
Rear mounting main switches
(.../V/SVB)
2
0 (Off) position lockable using up to
3 padlocks
Front IP65
Thumb-grip
9
Enclosures designed for metric cable
glands to EN 50 262
To IEC/EN 60 204
and IEC/EN 60 947-3,
up to 8 contacts for T0..., and up to 12
contacts for T3
Black thumb-grip with front plate
With PE terminal
a Page 07/062
With door interlock in I (On) position
a Page 07/013
a Page 07/013
Coupling drive
10
Safety switches (.../I...)
IP65
5
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ basic switches
in the rear mounting form Spare parts for
T0(T3)/(P1)-.../Z
Flush mounting (.../E)
Front IP65
3
With PE terminal
With cover fixing in the 0 (Off) position
0 (Off) position lockable using up to
3 padlocks
Fitting and connection from the rear
For retrofit conversion of T5(B)-.../E
flush mounting switches to rear mounting
form Spare part for T5(B)-.../Z
Terminal:
Pozidriv plus-minus screw
Enclosures designed for metric cable
glands to EN 50 262
Finger and back-of-hand proof
a Page 07/066
Type T8 with extension terminals as
standard
With “Safety Switch” label
Colour: orange
For Switzerland: comply with the Swiss
Accident Insurance Institute Directive
a Page 07/018
a Page 07/024
Flush mounting main switches
(.../EA/SVB)
3
Front IP65
To IEC/EN 60 204
and IEC/EN 60 947-3,
up to 8 contacts for T0..., and up to 12
contacts for T3
N terminal and PE terminal
a Page 07/012
Moeller HPL0211-2001/2002
07/008
P Switch-Disconnectors
System Overview
P1, P3 On-Off switches
4
1
4
1
2
11
3
11
10
9
10
5
9
6
8
8
7
7
Moeller HPL0211-2001/2002
07/009
P Switch-Disconnectors
System Overview
Service distribution board mounting
(.../IVS)
1
Flush mounting main switches
(.../EA/SVB)
3
Safety switches (.../I...-SI)
6
IP65
Front IP30
Front IP65
With PE terminal
Fitting dimensions to DIN 43 880
To IEC/EN 60 204 and
IEC/EN 60 947-3
With cover fixing in the 0 (Off) position
For snap fitting to
EN 50 022 top-hat rail
0 (Off) position lockable using up to
3 padlocks
N terminal and PE terminal
Space requirement
P1, 3-pole: 3 space units
P3, 3-pole: 4 space units
P3-.../IVS can be locked in 0 (Off) position
using the padlocking feature
0 (Off) position lockable using up to
3 padlocks
2 add-on modules can be fitted
(or retrofitted)
With “Safety Switch” label
Colour: orange
Enclosures designed for metric cable
glands to EN 50 262
For Switzerland: comply with the Swiss
Accident Insurance Institute Directive
a Page 07/012
a Page 07/019
a Page 07/024
Centre mounting (.../EZ)
3
Rear mounting (.../Z)
Front IP65
2
Front IP65
Mounting in ∅ 22.3 fixing hole
to IEC/EN 60 947-5-1
Main switch (assembly kit)
for use as Emergency-Stop device
7
Secured by snap fitting or screw fixing
Centre fixing permits installation by one
fitter
To IEC/EN 60 204-1
For snap fitting to EN 50 022
top-hat rail
With red rotary handle and yellow locking
collar
Coupling drive in door or cover
Connection from the front
a Page 07/019
Lockable in the 0 (Off) position
2 add-on modules can be fitted
(or retrofitted)
a Page 07/062
Add-on modules
4
Switched neutral
(early-make contact)
a Page 07/019
Main switch (assembly kit)
8
9
HI 11 auxiliary contact = 1 make contact +
Black rotary handle and locking collar
Lockable in the 0 (Off) position
1 break contact
Rear mounting main switches
(.../V/SVB)
2
Finger-proof
Auxiliary make contact:
always connected as load-shedding
contact (late-make, early-break)
a Page 07/062
Front IP65
To IEC/EN 60 204 and
IEC/EN 60 947-3
With door interlock in I (On) position
a Page 07/064
Thumb-grip
for use in Emergency-Stop devices
Maintenance key for commissioning or
fault tracing
To IEC/EN 60 204-1
0 (Off) position lockable using up to
3 padlocks
Red thumb-grip with yellow front plate
Surface mounting (.../I...)
IP65
5
2 add-on modules can be fitted
(or retrofitted)
a Page 07/062
With PE terminal
Add-on modules for retrofitting:
P1: + 1, P3: + 2
a Page 07/013
Enclosures designed for metric cable
glands to EN 50 262
Thumb-grip
10
Black thumb-grip with front plate
Flush mounting (.../E)
Front IP65
3
a Page 07/019
a Page 07/062
Fitting and connection from the rear
Terminal:
Surface mounting main switches
(.../I...)
5
Coupling drive
11
Pozidriv plus-minus screw
Includes push-fit shaft
Finger and back-of-hand proof
IP65
For retrofitting T0(T3)-.../XZ basic switches
in the rear mounting form Spare parts for
T0(T3)/(P1)-.../Z
2 add-on modules can be fitted
(or retrofitted)
With PE terminal
To IEC/EN 60 204 and
IEC/EN 60 947-3
For retrofit conversion of T5(B)-.../E
flush mounting switches to rear mounting
form Spare part for T5(B)-.../Z
a Page 07/018
0 (Off) position lockable using up to
3 padlocks
Add-on modules for retrofitting:
P1: + 1, P3: + 2
Enclosures designed for metric cable
glands to EN 50 262
a Page 07/066
a Page 07/013
Moeller HPL0211-2001/2002
07/010
T Rotary Switches, P Switch-Disconnectors
Key to Type References, Modular System
Rotary switches are suitable for many different
switching and control functions, e.g. as On-Off
switches, main switches, main circuit/auxiliary circuit
control switches, instrument selector switches.
The contact chamber (contact unit) contains
1 or 2 contacts.
T rotary switches and P switch-disconnectors are
manufactured without PCB, CFC, asbestos or silicon.
The contacts are cadmium-free.
Our “T Rotary Switches” catalogue, K115, shows
more than 800 often used standard contact
sequences (available on request).
The CI-K insulated enclosures do not contain silicon
The switches consist of a handle, basic switch and
mounting accessories.
Technical Data for CI-K small enclosures: a See Instal-
lation Equipment Catalogue, HPL0212-2000GB
On the following Pages, you will find a selection of
the standard contact sequences we offer.
T0 and T3 rotary switches
Key to type references
T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .
↑
↑
↑
↑
↑
↑
Switch size
T0 or T3
Number of contact chambers
= contact units
Contact sequence
number
Mounting form
a Page 07/004
Front plate Type
(if different from list
Type)
Accessories
a Page 07/056
a Page 07/054
Using the modular system to convert the mounting form
CI-K1-T0
CI-K2-T3
T0(3).../E
EZ-T0
V/EA/SVB-T0
T0(3).../XZ
IVS-T0
DE-T0
V/EA/SVB-T0
T0.../IVS1)
T0-.../I11)
T3-.../I21)
T0(3).../Z1)
T0(3).../EZ
T0-1-(T3-1-).../EA/SVB
.
.
.
T0-4-(T3-6-).../EA/SVB
T0-1-(T3-1-).../V/SVB
.
.
.
T0-4-(T3-1-).../V/SVB
T5(B) rotary switches
Key to type references
T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .
↑
↑
↑
↑
↑
↑
Switch size
T5(B)
Number of contact chambers
= contact units
Contact sequence
number
Mounting form
a Page 07/004
Front plate Type
(if different from list
Type)
Accessories
a Page 07/054
a Page 07/054
Using the modular system to convert the mounting form of T5(B)
T5(B)...E
V/EA/SVB-T5
DE-P3
CI-K4-T5B
CI-K5-T5
SVB-P3
V/EA/SVB-T5
T5B-.../I4
T5-.../I5
T5(B).../EA/SVB
T5(B).../Z
T5(B).../V/SVB
T5B-.../I4/SVB
T5-.../I5/SVB
Notes
Types preceded by “+...” are additions to the
basic Type and cannot be ordered separately.
1) Includes shaft
Moeller HPL0211-2001/2002
07/011
T Rotary Switches, P Switch-Disconnectors
Key to Type References, Modular System
P1 and P3 switch-disconnectors
Key to type references
P . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . .
↑
↑
↑
↑
↑
Switch size
P1 or P3
Rated uninterrupted current
Mounting form
a Page 07/005
Type suffix
(if required)
Accessories
a Page 07/056
The modular system offers add-on functions
HI 11-P1/P3E or
HI 11-P1/P3Z
H-P...
N-P...E or
N-P...Z
UV-P...
Auxiliary contact
Can be fitted left
or right
N + PE terminals also
as cover interlock
on .../Z-switches.
Switched neutral
Can be fitted left
or right
Terminal shroud
can be fitted at
top and bottom
3-pole basic unit
.../E oder .../Z
(for P1.../I: left only)
(for P1.../I: left only)
TM mini rotary switches
The TM rotary switch requires very little space due to
its exceptionally small dimensions. It is particularly
well suited for switching the low voltages and low
currents which occur in electronic control panels, for
example. The gold-plated contacts provide extra reli-
ability and safety.
TM mini rotary switches have consecutive terminal
markings, beginning with 1.
Key to type references
TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .
↑
↑
↑
↑
Number of contact chambers
= contact units
Contact sequence
number
Mounting form
a Page 07/074
Accessories
a Page 07/083
Circuit diagrams
on Pages 07/012 – 053
and 07/074 – 082
Example:
(see also Ordering Example on Page 07/111)
Switch position 1:
Contact 1 – 2 open,
1
2
3
4
1
2
3
4
Contact 3 – 4 closed.
Terminal marking
Link
Switching from 1 to 2:
Contact 1 – 2 closes with early make,
Contact 3 – 4 opens with late break.
0
1
2
0
1
2
Contact open
Switching from 2 to 3:
Contact 1 – 2 opens briefly.
Contact closed
Switch position
Switching from 3 to 4:
Contact 1 – 2 remains closed,
Automatic return from 4 to 3.
3
4
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/012
T Rotary Switches, P Switch-Disconnectors
Main Switches, Maintenance Switches
07/013
T Rotary Switches, P Switch-Disconnectors
Main Switches, Maintenance Switches
For use as
Emergency-Stop device1)
Without Emergency-Stop function2)
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
Front IP65
Surface
mounting 3)
IP65
Rear mounting
Front IP65
Flush mounting
Front IP65
Surface
Rear mounting
Front IP65
uninter-
rupted
current
mounting 3)
IP65
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
OFF
Basic type
Mounting
form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting
form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
FS 908
For ... insert
Article no.
Article no.
Article no.
Article no.
mounting form Article no.
Article no.
M
1
M
0
B
0
kW
kW
kW
A
Main switches
1
1.3
3.6
7.3
12.3
2.2
5.5
11
18.5
4
–
20
T0-1-8200/...
T3-1-8200/...
EA/SVB
053110
I1/SVB
207145
V/SVB
057856
EA/SVB-SW
055483
I1/SVB-SW
207146
V/SVB-SW
060229
1
2
1.8
5
–
32
EA/SVB
066576
I2/SVB
207200
V/SVB
007255
EA/SVB-SW
068949
I2/SVB-SW
207201
V/SVB-SW
004882
–
63
T5B-1-8200/... EA/SVB
I4/SVB
207240
V/SVB
094273
EA/SVB-SW
094278
I4/SVB-SW
207241
V/SVB-SW
094272
094279
7.3
2.2
3
–
100
20
T5-1-8200/...
T0-1-102/...
T3-1-102/...
T5B-1-102/...
T5-1-102/...
T0-2-1/...
EA/SVB
097224
I5/SVB
207275
V/SVB
097222
EA/SVB-SW
097223
I5/SVB-SW
207276
V/SVB-SW
097221
2
3
0
0
0
0
–
EA/SVB
091078
EA/SVB
014374
I1/SVB
207143
I2/SVB
207198
V/SVB
095824
V/SVB
019120
EA/SVB-SW
093451
EA/SVB-SW
016747
I1/SVB-SW
207144
I2/SVB-SW
207199
V/SVB-SW
022330
V/SVB-SW
021493
1
2
3
4
–
32
7.5
11
3
–
63
EA/SVB
094469
I4/SVB
207238
V/SVB
094463
EA/SVB-SW
094468
I4/SVB-SW
207239
V/SVB-SW
094462
–
100
20
EA/SVB
098808
I5/SVB
207273
V/SVB
098806
EA/SVB-SW
098807
I5/SVB-SW
207274
V/SVB-SW
098805
4
EA/SVB
038873
I1/SVB
207147
V/SVB
043619
EA/SVB-SW
041246
I1/SVB-SW
207148
V/SVB-SW
045992
1
3
5
6
2
4
5.5
7.5
15
22
22
3
7.5
13
30
37
37
4
7.5
15
30
37
22
4
25
P1-25/...
EA/SVB
I2/SVB
V/SVB
EA/SVB-SW
I2/SVB-SW
V/SVB-SW
041097
207293
055335
048365
207294
050738
32
P1-32/...
EA/SVB
081438
I2/SVB
207314
V/SVB
095676
EA/SVB-SW
053111
I2/SVB-SW
207315
V/SVB-SW
055484
63
P3-63/...
EA/SVB
031607
I4/SVB
207343
V/SVB
048218
EA/SVB-SW
057857
I4/SVB-SW
207344
V/SVB-SW
060230
100
125
20
P3-100/...
T6-2/...
EA/SVB
074320
I5/SVB
207373
V/SVB
088558
EA/SVB-SW
062603
I5/SVB-SW
207374
V/SVB-SW
064976
EA/SVB
012679
–
V/SVB
015052
EA/SVB-SW
067349
–
V/SVB-SW
069722
3+N
0
0
T0-2-8900/...
P1-25/...
EA/SVB
207400
I1/SVB
207151
V/SVB
207405
EA/SVB-SW
207401
I1/SVB-SW
207152
V/SVB-SW
207406
1
3
5
7
8
2
4
6
5.5
7.5
15
22
3
7.5
13
30
37
4
7.5
15
30
37
4
25
EA/SVB/N
081587
I2/SVB/N
207298
V/SVB/N
086333
EA/SVB-SW/N
083960
I2/SVB-SW/N
207296
V/SVB-SW/N
088706
1
3
5
N
32
P1-32/...
EA/SVB/N
091079
I2/SVB/N
207319
V/SVB/N
095825
EA/SVB-SW/N
093452
I2/SVB-SW/N
207317
V/SVB-SW/N
098198
2
4
6
N
63
P3-63/...
EA/SVB/N
010398
I4/SVB/N
207349
V/SVB/N
015144
EA/SVB-SW/N
012771
I4/SVB-SW/N
207346
V/SVB-SW/N
017517
100
20
P3-100/...
T0-3-8342/...
T3-3-8342/...
EA/SVB/N
019890
I5/SVB/N
207379
V/SVB/N
024636
EA/SVB-SW/N
022263
I5/SVB-SW/N
207376
V/SVB-SW/N
027009
6
8
0
0
0
0
EA/SVB
029382
I1/SVB
207159
V/SVB
034128
EA/SVB-SW
031755
I1/SVB-SW
207160
V/SVB-SW
036501
1
3
5
7
8
9
11
2
4
6
10 12
6.5
15
18.5
3
12
22
30
4
15
22
30
4
32
EA/SVB
071326
I2/SVB
207208
V/SVB
076072
EA/SVB-SW
073699
I2/SVB-SW
207209
V/SVB-SW
078445
63
T5B-3-8342/... EA/SVB
I4/SVB
207242
V/SVB
092300
EA/SVB-SW
092307
I4/SVB-SW
207243
V/SVB-SW
092299
092308
100
20
T5-3-8342/...
T0-4-8344/...
T3-4-8344/...
EA/SVB
096383
I5/SVB
207279
V/SVB
096381
EA/SVB-SW
096382
I5/SVB-SW
207280
V/SVB-SW
096380
EA/SVB
008267
I1/SVB
207163
V/SVB
014007
EA/SVB-SW
008268
I1/SVB-SW
207164
V/SVB-SW
008272
1
3
5
7
8
9
11 13 15
2
4
6
10 12 14 16
6.5
15
22
12
22
30
15
22
30
32
EA/SVB
008964
I2/SVB
207212
V/SVB
020598
EA/SVB-SW
008965
I2/SVB-SW
207213
V/SVB-SW
008967
63
T5B-4-8344/... EA/SVB
I4/SVB
207248
V/SVB
092056
EA/SVB-SW
092061
I4/SVB-SW
207249
V/SVB-SW
092055
092062
1004)
T5-4-8344/...
EA/SVB
095961
I5/SVB
207283
V/SVB
095959
EA/SVB-SW
095960
I5/SVB-SW
207284
V/SVB-SW
095958
Standard pack: 1 off
Standard pack: 1 off
1)
2)
3)
4)
Notes
To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position
With black rotary handle and locking collar, lockable in 0 (Off) position
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
T5-4-8344/I5... max. 95 A
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/014
T Rotary Switches, P Switch-Disconnectors
Main Switches with Auxiliary Contacts, Maintenance Switches
07/015
T Rotary Switches, P Switch-Disconnectors
Main Switches with Auxiliary Contacts, Maintenance Switches
For use as
Emergency-Stop device1)
Without Emergency-Stop function2)
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
Front IP65
Surface
mounting 4)
IP65
Rear mounting
Front IP65
Flush mounting
Front IP65
Surface
mounting 4)
IP65
Rear mounting
Front IP65
uninter-
rupted
current
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
OFF
Basic type
Mounting form
Price
See Price
List
Mounting
form
Price
See Price
List
Mounting
form
Price
See Price
List
Mounting form
Price
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
FS 908
For ... insert
Article no.
Article no.
Article no.
See Price Article no.
List
mounting form
Article no.
Article no.
M
3
M
1
B
0
kW
3
kW
4
kW
4
A
Main switches with auxiliary contacts
20
T0-2-15679/...
EA/SVB
081588
I1/SVB
207149
V/SVB
086334
EA/SVB-SW
083961
I1/SVB-SW
207150
V/SVB-SW
088707
1
3
5
7
2
4
6
8
3
1
1
5.5
7.5
15
22
3
7.5
13
30
37
4
7.5
15
30
37
4
25
32
63
100
20
32
P1-25/...
EA/SVB/HI11
I2/SVB/HI11
V/SVB/HI11
EA/SVB-SW/HI11
I2/SVB-SW/HI11
V/SVB-SW/HI11
1
3
5
13 21
14 22
091080
207297
095826
070194
207295
098199
2
4
6
P1-32/...
EA/SVB/HI11
072567
I2/SVB/HI11
207318
V/SVB/HI11
015145
EA/SVB-SW/HI11
012772
I2/SVB-SW/HI11
207316
V/SVB-SW/HI11
017518
P3-63/...
EA/SVB/HI11
019891
I4/SVB/HI11
207348
V/SVB/HI11
024637
EA/SVB-SW/HI11
022264
I4/SVB-SW/HI11
207345
V/SVB-SW/HI11
027010
P3-100/...
T0-3-15683/...
T3-3-15683/...
EA/SVB/HI11
029383
EA/SVB
015571
I5/SVB/HI11
207378
I1/SVB
207157
V/SVB/HI11
034129
V/SVB
015634
EA/SVB-SW/HI11
031756
EA/SVB-SW
015600
I5/SVB-SW/HI11
207375
I1/SVB-SW
207158
V/SVB-SW/HI11
036502
V/SVB-SW
015664
L1 L2 L3
3
2
1
1
1
1
3
5
7
8
9
11
2
4
6
10 12
6.5
12
15
EA/SVB
040478
I2/SVB
207206
V/SVB
045224
EA/SVB-SW
042851
I2/SVB-SW
207207
V/SVB-SW
047597
L1 L2 L3
N
3+N
3
4
4
20
32
T0-3-15680/...
T3-3-15680/...
EA/SVB
038875
I1/SVB
207153
V/SVB
043621
EA/SVB-SW
041248
I1/SVB-SW
207154
V/SVB-SW
045994
1
3
5
7
9
11
6.5
12
15
EA/SVB
012002
I2/SVB
207202
V/SVB
016748
EA/SVB-SW
014375
I2/SVB-SW
207203
V/SVB-SW
019121
2
4
6
8
10 12
L1 L2 L3
N
3+N
3+N
6
1
1
1
1
1
1
1
1
5.5
7.5
15
7.5
13
30
37
4
7.5
15
30
37
4
25
P1-25/...
EA/SVB/N/HI11
–
–
V/SVB/N/HI11
EA/SVB-SW/N/HI11
–
–
V/SVB-SW/N/HI11
1
3
5
13 21
14 22
048367
053113
050740
055486
2
4
6
N
32
P1-32/...
EA/SVB/N/HI11
057859
V/SVB/N/HI11
062605
EA/SVB-SW/N/HI11
060232
V/SVB-SW/N/HI11
064978
63
P3-63/...
EA/SVB/N/HI11
067351
EA/SVB/N/HI11
076843
I4/SVB/N/HI11
207350
I5/SVB/N/HI11
207380
V/SVB/N/HI11
072097
V/SVB/N/HI11
081589
EA/SVB-SW/N/HI11
069724
EA/SVB-SW/N/HI11
079216
I4/SVB-SW/N/HI11
207347
I5/SVB-SW/N/HI11
207377
V/SVB-SW/N/HI11
074470
V/SVB-SW/N/HI11
083962
22
100
20
P3-100/...
L1 L2 L3
N
3
T0-3-15681/...
T3-3-15681/...
T5B-3-8901/...
T5-3-8901/...
T0-4-15682/...
T3-4-15682/...
T5B-4-15682/...
T5-4-15682/...
T6-160-6/...
T8-3-8342/...
EA/SVB
086335
I1/SVB
207155
V/SVB
091081
EA/SVB-SW
088708
I1/SVB-SW
207156
V/SVB-SW
093454
1
3
5
7
9
11
2
4
6
8
10 12
6.5
15
12
22
30
4
15
22
30
4
32
EA/SVB
026240
I2/SVB
207204
V/SVB
030986
EA/SVB-SW
028613
I2/SVB-SW
207205
V/SVB-SW
033359
63
EA/SVB
207420
I4/SVB
207244
V/SVB
207422
EA/SVB-SW
207421
I4/SVB-SW
207245
V/SVB-SW
207423
18.5
3
100
20
EA/SVB
207408
I5/SVB
207277
V/SVB
207410
EA/SVB-SW
207409
I5/SVB-SW
207278
V/SVB-SW
207411
1
3
4
5
6
7
8
9
11 13 15
EA/SVB
019892
I1/SVB
207161
V/SVB
024638
EA/SVB-SW
022265
I1/SVB-SW
207162
V/SVB-SW
027011
2
10 12 14 16
6.5
15
12
22
30
42
55
15
22
30
22
37
32
EA/SVB
054716
I2/SVB
207210
V/SVB
059462
EA/SVB-SW
057089
I2/SVB-SW
207211
V/SVB-SW
061835
63
EA/SVB
207425
I4/SVB
207246
V/SVB
207427
EA/SVB-SW
207426
I4/SVB-SW
207247
V/SVB-SW
207428
18.5
22
100
160
3153)
EA/SVB
207413
I5/SVB
207281
I45/SVB/HI115)
201448
I48/SVB/HI116)
201450
V/SVB
207415
EA/SVB-SW
207414
I5/SVB-SW
207282
I45/SVB-SW/HI115)
201447
I48/SVB-SW/HI116)
201449
V/SVB-SW
207416
1
3
5
7
9
11 13 21
6
–
V/SVB/HI11
200619
–
V/SVB-SW/HI11
200127
2
4
6
8
10 12 14 22
37
–
V/SVB/HI11
200620
–
V/SVB-SW/HI11
200128
Standard pack: 1 off
Standard pack: 1 off
1)
2)
3)
4)
5)
6)
Notes
To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position
With black rotary handle and locking collar, lockable in 0 (Off) position
Enclosed version, up to 275 A
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Enclosures without flanges, with K95/1N/BR
With KS4-CI and K150/1/BR
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/016
T Rotary Switches, P Switch-Disconnectors
Main Switches, Maintenance Switches in Sheet Steel Enclosures
07/017
T Rotary Switches, P Switch-Disconnectors
Main Switches, Maintenance Switches in Sheet Steel Enclosures
For use as Emergency-Stop
device1)
Without Emergency-Stop
function2)
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Surface mounting
IP65
Surface mounting
IP65
uninter-
rupted
current
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
OFF
Basic type
Mounting form
Price
See Price
List
Mounting
form
Price
See Price
List
FS 908
For ... insert
Article no.
mounting form
Article no.
M
3
M
0
B
0
kW
kW
kW
A
Main switches in sheet steel enclosures
3
4
4
20
25
T0-2-1/...
P1-25/...
P1-32/...
P3-63/...
P3-100/...
ST/SVB
025528
ST/SVB-SW
201713
1
3
5
2
4
6
5.5
7.5
15
22
7.5
13
30
37
7.5
15
30
37
ST/SVB
025523
ST/SVB-SW
201714
32
ST/SVB
025522
ST/SVB-SW
201715
63
ST/SVB
025521
ST/SVB-SW
201716
100
ST/SVB
025520
ST/SVB-SW
201717
Main switches with auxiliary contacts
6
1
1
3
4
4
20
T0-4-15682/...
T3-4-15682/...
T5B-4-15682/...
T5-4-15682/...
ST/SVB
ST/SVB-SW
1
3
5
7
9
11 13 15
025527
201718
2
4
6
8
10 12 14 16
6.5
15
12
22
30
15
22
30
32
ST/SVB
025526
ST/SVB-SW
201719
63
ST/SVB
215328
ST/SVB-SW
215329
18.5
100
ST/SVB
215330
ST/SVB-SW
215331
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position
With black rotary handle and locking collar, lockable in 0 (Off) position
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/018
T Rotary Switches, P Switch-Disconnectors
07/019
T Rotary Switches, P Switch-Disconnectors
On-Off Switches
On-Off Switches
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface mounting 2)
IP65
Service distribution board
Rear mounting
Front IP65
uninter-
rupted
current
mounting
Front IP30
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
Basic type
Mounting
form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
For ... insert
Article no.
Article no.
Article no.
OFF
mounting form Article no.
FS 908
M
1
M
0
B
0
kW
kW
kW
A
On-Off switches1)
1
1.3
3.6
7.3
12.3
2.2
5.5
11
18.5
4
–
20
T0-1-8200/...
T3-1-8200/...
T5B-1-8200/...
T5-1-8200/...
T0-1-102/...
T3-1-102/...
T5B-1-102/...
T5-1-102/...
T0-2-1/...
E
EZ
069725
I1
207074
IVS
074471
Z
1
067352
076844
2
1.8
5
–
32
E
EZ
066581
I2
207167
–
–
–
Z
064208
071327
–
63
E
–
I4
207218
Z
094281
094270
7.3
2.2
3
–
100
20
E
–
I5
207264
Z
097226
097219
2
3
0
0
0
0
–
E
EZ
091082
I1
207061
IVS
015147
Z
1
2
3
4
088709
095828
–
32
E
EZ
078446
I2
207165
–
–
–
Z
076073
083192
7.5
11
3
–
63
E
–
–
I4
207215
Z
094471
094460
–
100
20
E
I5
207262
Z
098810
098803
4
E
EZ
027012
I1
207081
IVS
031758
Z
1
3
5
6
024639
036504
2
4
5.5
7.5
15
22
22
3
7.5
13
30
37
37
4
7.5
15
30
37
22
4
25
P1-25/...
E
EZ
I2
IVS
Z
038724
041250
207299
052962
057708
32
P1-32/...
E
EZ
048369
I2
207320
IVS
093303
Z
079065
098049
63
P3-63/...
E
–
–
–
I4
207356
I5
207381
IVS
041099
IVS
081439
Z
026861
050591
100
125
20
P3-100/...
E
Z
067201
090931
T6-2/...
E
–
–
–
098106
3+N
0
0
T0-2-8900/...
P1-25/...
E
EZ
207402
I1
207109
IVS
207403
Z
1
3
5
7
8
207398
207407
2
4
6
5.5
7.5
15
22
3
7.5
13
30
37
4
7.5
15
30
37
4
25
E/N
076845
EZ/N
079218
I2/N
207303
IVS/N
083964
Z/N
088710
32
P1-32/...
E/N
093456
EZ/N
095829
I2/N
207324
IVS/N
010402
Z/N
015148
1
3
4
5
6
N
N
2
63
P3-63/...
E/N
019894
–
I4/N
207360
IVS/N
022267
Z/N
027013
100
20
P3-100/...
E/N
031759
–
I5/N
207385
IVS/N
034132
Z/N
038878
6
8
0
0
0
0
T0-3-8342/...
T3-3-8342/...
T5B-3-8342/...
T5-3-8342/...
T0-4-8344/...
T3-4-8344/...
T5B-4-8344/...
T5-4-8344/...
E
EZ
045997
I1
207131
IVS
050743
Z
1
3
4
5
6
7
8
9
11
043624
055489
2
10 12
6.5
15
18.5
3
12
22
30
4
15
22
30
4
32
E
EZ
047598
I2
207187
–
–
–
Z
045225
052344
63
E
–
–
I4
207226
Z
092310
092297
100
20
E
I5
207267
I1
207139
Z
096385
096378
E
EZ
014002
IVS
014006
Z
1
3
5
7
9
11 13 15
014000
014009
2
4
6
8
10 12 14 16
6.5
15
22
12
22
30
–
32
E
EZ
020595
I2
207194
–
–
–
Z
020593
020600
22
30
63
E
–
I4
207233
Z
092064
092053
1003)
E
–
I5
207272
Z
095963
095956
Standard pack: 1 off
Standard pack: 1 off
1)
2)
3)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
T5-4-8344/I5 up to 95 A
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/020
T Rotary Switches, P Switch-Disconnectors
On-Off Switches with Auxiliary Contacts
07/021
T Rotary Switches, P Switch-Disconnectors
On-Off Switches with Auxiliary Contacts
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution
board mounting
Front IP30
Rear mounting
Front IP65
uninter-
rupted
current
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
Basic type
For ... insert
Mounting
form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
OFF
Article no.
Article no.
Article no.
Article no.
mounting form
A
Article no.
FS 908
M
3
M
1
B
0
kW
3
kW
4
kW
4
On-Off switches with auxiliary contacts1)
20
T0-2-15679/...
E
EZ
031760
I1
207094
IVS
036506
Z
1
3
5
7
029387
041252
2
4
6
8
1
3
4
5
6
13 21
14 22
P1-25/...
E/HI11
EZ/HI11
I2/HI11
IVS/HI11
Z/HI11
3
1
1
5.5
7.5
15
22
3
7.5
13
30
37
4
7.5
15
30
37
4
25
32
63
100
20
32
045998
048371
207302
053117
057863
2
P1-32/...
E/HI11
062609
EZ/HI11
064982
I2/HI11
207323
IVS/HI11
069728
Z/HI11
074474
P3-63/...
E/HI11
079220
–
I4/HI11
207359
IVS/HI11
081593
Z/HI11
086339
P3-100/...
T0-3-15683/...
T3-3-15683/...
E/HI11
069574
–
I5/HI11
207384
I1
207118
IVS/HI11
091085
IVS
016722
Z/HI11
093304
L1 L2 L3
3
6
2
1
1
1
E
EZ
016658
Z
1
3
5
7
8
9
11
016619
016843
2
4
6
10 12
6.5
12
15
E
EZ
040480
I2
207182
–
Z
014377
019123
1
3
4
5
6
7
8
9
11 13 15
3
4
4
20
T0-4-15682/...
T3-4-15682/...
T5B-4-15682/...
T5-4-15682/...
E
EZ
012778
I1
207135
IVS
017524
Z
010405
022270
2
10 12 14 16
6.5
15
12
22
30
15
22
30
32
E
EZ
026242
I2
207190
–
–
–
Z
023869
030988
63
E
–
–
I4
207229
Z
207424
207429
18.5
100
E
I5
207269
Z
207412
207417
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/022
T Rotary Switches, P Switch-Disconnectors
07/023
T Rotary Switches, P Switch-Disconnectors
On-Off Switches
On-Off Switches
Circuit diagram
Front
plate
no.
Main
contacts
Auxiliary
contacts
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
Front IP65
Surface mounting 2)
IP65
Service distribution board mounting
Front IP30
uninter-
rupted
current
50–60 Hz
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
1
Basic type
Mounting
form
Price
See Price
List
Mounting form
Price
See Price
List
Mounting form
Price
See Price
List
0
For ... insert
Article no.
Article no.
mounting form Article no.
FS 908 GE
M
M
0
B
0
kW
kW
kW
A
On-Off switches for use as Emergency-Stop devices1)
1
1
1.3
3.6
7.3
12.3
2.2
5.5
11
–
20
T0-1-8200/...
T3-1-8200/...
E-RT
009474
I1-RT
207075
IVS-RT
081956
1
2
1.8
5
–
32
E-RT
017025
I2-RT
207168
–
–
–
–
63
T5B-1-8200/... E-RT
094280
I4-RT
207219
7.3
2.2
3
–
100
20
T5-1-8200/...
T0-1-102/...
T3-1-102/...
T5B-1-102/...
T5-1-102/...
T0-2-1/...
E-RT
097225
I5-RT
207265
2
0
0
0
0
–
E-RT
009046
I1-RT
207062
IVS-RT
079583
1
2
3
4
–
32
E-RT
016318
I2-RT
207166
–
–
–
7.5
11
3
–
63
E-RT
094470
I4-RT
207216
18.5
4
–
100
20
E-RT
098809
I5-RT
207263
3
4
E-RT
011082
I1-RT
207082
IVS-RT
084329
1
3
5
6
2
4
5.5
7.5
15
22
3
7.5
13
7.5
15
30
37
4
25
P1-25/...
E-RT
I2-RT
IVS-RT
002388
207300
013140
32
P1-32/...
E-RT
003197
I2-RT
207321
IVS-RT
022632
30
63
P3-63/...
E-RT
005743
E-RT
007189
I4-RT
207357
I5-RT
207382
IVS-RT
045845
IVS-RT
086185
37
100
20
P3-100/...
T0-2-8900/...
P1-25/...
3+N
0
0
4
E-RT
207399
I1-RT
207110
IVS-RT
207404
1
3
4
5
6
7
8
2
5.5
7.5
15
22
7.5
13
7.5
15
30
37
25
E-RT/N
002425
I2-RT/N
207301
IVS-RT/N
017886
1
3
4
5
6
N
N
32
P1-32/...
E-RT/N
004555
I2-RT/N
207322
IVS-RT/N
027378
2
30
63
P3-63/...
E-RT/N
007136
I4-RT/N
207358
IVS-RT/N
041616
37
100
P3-100/...
E-RT/N
007280
I5-RT/N
207383
IVS-RT/N
034497
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
To IEC/EN 60 204-1; with red thumb-grip and yellow front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/024
07/025
T Rotary Switches, P Switch-Disconnectors
Safety Switches
T Rotary Switches, P Switch-Disconnectors
Safety Switches
For use as Emergency-Stop
device1)
Without Emergency-Stop function2)
Circuit diagram
Front
plate no.
Main
contacts
Auxiliary
contacts
Max. three-phase
Rated
Surface mounting
Surface mounting 3)
IP65
Notes
motor rating (per set of
3 contacts)
uninter- IP65
rupted
50–60 Hz
current
No. of
poles
Iu
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
ON
OFF
Type
Article no.
Price
See Price
List
Type
Article no.
Price
See Price
List
FS 908
M
3
M
0
B
0
kW
kW
kW
A
Safety switches
5.5
7.5
7.5
13
7.5
15
25
32
P1-25/I2-SI
207308
P1-25/I2-SI-SW
207309
Padlocking feature with captive cover fixing
For general information on
1
2
3
4
5
6
Safety Switches a Page 07/109
With “Safety Switch” warning plate
(other languages on request)
For switches in accordance with the Swiss Accident
Insurance Institute Directive, please contact
P1-32/I2-SI
207329
P1-32/I2-SI-SW
207330
Neutral conductor or HI11 auxiliary contact can also be Moeller Switzerland
retrofitted to P1 and P3 safety switches
1
3
4
5
6
N
N
3+N
3
0
1
0
1
5.5
7.5
5.5
7.5
7.5
13
7.5
15
25
32
25
32
P1-25/I2-SI/N
P1-25/I2-SI/N-SW
207312
207313
a Page 07/065
2
P1-32/I2-SI/N
207333
P1-32/I2-SI/N-SW
207334
With auxiliary contacts
7.5
13
7.5
15
P1-25/I2-SI/HI11
207310
P1-25/I2-SI/HI11-SW
207311
1
3
5
13 21
P1-32/I2-SI/HI11
207331
P1-32/I2-SI/HI11-SW
207332
2
4
6
14 22
3
0
0
15
22
30
37
30
37
63
P3-63/I4-SI
P3-63/I4-SI-SW
1
2
3
4
5
6
207361
207362
100
P3-100/I5-SI
207386
P3-100/I5-SI-SW
207387
1
2
3
4
5
6
N
N
3+N
3
0
1
0
1
15
22
15
22
30
37
30
37
30
37
30
37
63
P3-63/I4-SI/N
P3-63/I4-SI/N-SW
207365
207366
100
63
P3-100/I5-SI/N
207390
P3-100/I5-SI/N-SW
207391
With auxiliary contacts
P3-63/I4-SI/HI11
207363
P3-63/I4-SI/HI11-SW
207364
1
3
5
13 21
100
P3-100/I5-SI/HI11
207388
P3-100/I5-SI/HI11-SW
207389
2
4
6
14 22
6
6
0
1
0
1
15
22
30
22
30
63
T5B-3-8342/I4-SI
T5B-3-8342/I4-SI-SW
No contacts can be retrofitted to T... rotary switches.
1
3
4
5
6
7
8
9
11
207250
207251
2
10 12
18.5
100
T5-3-8342/I5-SI
207447
T5-3-8342/I5-SI-SW
207448
With auxiliary contacts
15
22
30
22
30
63
T5B-4-15682/I4-SI
207254
T5B-4-15682/I4-SI-SW
207255
1
3
5
7
9
11 13 21
18.5
100
T5-4-15682/I5-SI
207285
T5-4-15682/I5-SI-SW
207286
2
4
6
8
10 12 14 22
With auxiliary contacts
6
2
0
15
22
30
22
30
63
T5B-4-8903/I4-SI
T5B-4-8903/I4-SI-SW
207258
207259
1
3
5
7
9
11 13 15
18.5
100
T5-4-8903/I5-SI
207289
T5-4-8903/I5-SI-SW
207290
2
4
6
8
10 12 14 16
Standard pack: 1 off
Standard pack: 1 off
1)
Notes
To IEC/EN 60 204 Part 1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position
with cover interlock
With black rotary handle and locking collar, lockable in 0 (Off) position with cover interlock
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
2)
3)
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/026
07/027
T Rotary Switches
Control Switches: Changeover Switches
T Rotary Switches
Control Switches: Changeover Switches
Circuit diagram
Front
plate no.
Max. three-phase
motor rating
(per set of 3 contacts)
50 – 60 Hz
Rated unin-
terrupted
current
Iu
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Servicedistribution
board mounting
Front IP30
Rear mounting
Front IP65
No. of
poles
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
Basic type
Mounting
form
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
For ... insert
mounting form Article no.
M
1
kW
kW
kW
A
Changeover switches with 0 (Off) position 1)
Group switches, mains transfer switches
1
3
0
1
1.3
3.6
7.3
2.2
5.5
11
4
–
20
T0-1-8210/...
T3-1-8210/...
T5B-1-8210/...
T0-2-8211/...
T3-2-8211/...
T5B-2-8211/...
T0-3-8212/...
T3-3-8212/...
T5B-3-8212/...
T5-3-8212/...
T6-3-8212/...
T8-3-8212/...
E
EZ
I1
IVS
Z
1
2
2
2
2
4
012742
048337
207076
074440
019862
1
0
2
1.8
5
–
32
E
EZ
003072
I2
207169
–
–
Z
FS 684
054718
057091
–
63
E
–
I4
207432
Z
094261
094258
1
2
3
5
6
7
8
0
1
2
3
2.2
3
–
20
E
EZ
053083
I1
207102
IVS
076813
Z
4
022234
029354
1
0
2
–
32
E
EZ
003075
I2
207178
–
–
Z
FS 684
061837
064210
7.5
3
–
63
E
–
I4
207220
Z
093094
093082
1
2
3
4
5
6
7
8
9
11
0
1
4
20
E
EZ
057829
I1
207123
IVS
079186
Z
10 12
029353
036473
1
0
2
6.5
15
18.5
22
37
12
22
30
37
55
15
22
30
22
37
32
E
EZ
003080
I2
207183
–
–
–
–
–
Z
FS 684
068956
071329
63
E
–
–
–
–
I4
207223
Z
092386
092383
100
125
315
E
I5
207266
Z
096466
096464
1
2
3
4
5
6
7
8
9
11 101 103 105
0
1
3
4
E/HI12
214781
–
–
–
–
2
10 12 102 104 106
1
0
2
E/HI12
214782
FS 684
1
3
5
7
9
11 13 15
0
1
3
4
4
20
T0-4-8213/...
T3-4-8213/...
T5B-4-8213/...
T5-4-8213/...
T0-4-8294/...
T3-4-8294/...
T5B-4-8294/...
T5-4-8294/...
T3-4-8902/...
T5B-4-8902/...
T5-4-8902/...
E
EZ
062575
I1
207136
IVS
081559
Z
2
2
4
6
8
10 12 14 16
031726
043592
1
0
2
6.5
15
12
22
30
4
15
22
30
4
32
E
EZ
003079
I2
207191
–
–
–
Z
FS 684
076075
078448
63
E
–
–
I4
207230
Z
092112
092109
18.5
3
100
20
E
I5
207270
I1
207138
Z
096014
096012
1
2
3
4
5
6
7
8
9
11 13 15
4
4
E
EZ
072069
IVS
043594
Z
0
1
2
010371
048347
10 12 14 16
1
0
2
6.5
15
12
22
30
12
22
30
15
22
22
15
22
22
32
E
EZ
001014
I2
207193
–
–
–
–
–
–
Z
FS 953
002513
004886
63
E
–
–
I4
207232
Z
092084
092081
18.5
6.5
15
100
32
E
I5
207433
Z
095986
095984
0
E
EZ
215223
I2
215224
Z
NOT-
1
3
5
6
7
8
9
11 13 15
NETZ STROM
215222
215225
2
4
10 12 14 16
63
E
–
I4
207237
Z
FS 161629
Mains
207430
207431
0
Emergency
supply
18.5
100
E
–
I5
207214
Z
207418
207419
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/028
07/029
T Rotary Switches
Control Switches: Changeover Switches
T Rotary Switches
Control Switches: Changeover Switches
Circuit diagram
Front
plate no.
Max. three-phase
motor rating (per set of
3 contacts)
Rated
uninter-
rupted
current
Iu
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
50–60 Hz
No. of
poles
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
0
Basic type
Mounting
form
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
1
2
For ... insert
mounting form Article no.
FS 4011
M
kW
kW
kW
A
Changeover switches with 0 (Off) position1)
With spring-return from both directions to 0
1
3
1
2
3
1
1.3
3.6
2.2
5.5
4
–
20
32
20
32
20
32
T0-1-8214/...
T3-1-8214/...
T0-2-8215/...
T3-2-8215/...
T0-3-8216/...
T3-3-8216/...
E
EZ
I1
IVS
Z
2
4
019863
076815
207077
045967
050720
1
0
2
1.8
2.2
3
–
E
EZ
001073
I2
207170
–
Z
009632
012005
1
2
3
4
5
6
7
8
–
E
EZ
081561
I1
207103
IVS
048340
Z
022236
053093
1
0
2
–
E
EZ
001074
I2
207179
–
Z
016751
019124
1
2
3
4
5
6
7
8
9
11
3
4
E
EZ
086307
I1
207434
IVS
050713
Z
024609
055466
10 12
1
0
2
6.5
12
15
E
EZ
001077
I2
207184
–
Z
023870
026243
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/030
07/031
T Rotary Switches
Control Switches: Changeover Switches
T Rotary Switches
Control Switches: Changeover Switches
Circuit diagram
Front
plate
no.
Max. three-phase
motor rating (per set of
3 contacts)
Rated
uninter-
rupted
current
Iu
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
50–60 Hz
No. of
poles
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
Basic type
Mounting
form
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
2
1
For ... insert
mounting form Article no.
FS 943
M
kW
kW
kW
A
Changeover switches without 0 (Off) position1)
Changeover switches
1
3
1
2
1.1
1.8
2.2
3
1.3
3.6
2.2
5.5
11
4
–
20
32
20
32
63
20
32
63
20
32
63
100
20
32
20
32
20
32
T0-1-8220/...
T3-1-8220/...
T0-2-8221/...
T3-2-8221/...
T5B-2-8221/...
T0-3-8222/...
T3-3-8222/...
T5B-3-8222/...
T0-4-8223/...
T3-4-8223/...
T5B-4-8223/...
T5-4-8223/...
T0-5-8369/...
T3-5-8369/...
T0-6-8370/...
T3-6-8370/...
T0-8-8372/...
T3-8-8372/...
E
EZ
I1
IVS
Z
031728
095799
207078
055459
086312
2
4
1
2
–
E
EZ
001018
I2
207171
–
Z
038108
040481
1
3
5
6
7
8
–
E
EZ
010372
I1
207104
IVS
057832
Z
2
4
038847
074450
1
2
–
E
EZ
001025
I2
207180
–
Z
045227
047600
7.5
3
–
E
–
I4
207221
–
Z
093047
093044
1
3
5
7
9
11
3
4
4
E
EZ
015118
I1
207124
IVS
060205
Z
048339
088686
2
4
6
8
10 12
1
2
6.5
15
3
12
22
4
15
22
4
E
EZ
001069
I2
207185
–
Z
052346
057092
E
–
I4
207224
–
Z
092378
092375
1
2
3
4
5
6
7
8
9
11 13 15
E
EZ
019864
I1
207137
IVS
062578
Z
050712
086315
10 12 14 16
1
2
6.5
15
18.5
3
12
22
30
4
15
22
30
4
E
EZ
001070
I2
207192
–
–
–
Z
059465
061838
E
–
I4
207231
I5
207271
Z
092108
092105
E
–
Z
096010
096008
5
6
8
E
EZ
024610
–
IVS
064951
Z
1
2
3
5
7
9
11
15 17 19
13
060204
098180
4
6
8
10 12 14 16 18 20
1
2
6.5
3
12
4
15
4
E
EZ
004503
I2
207536
–
Z
066584
068957
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
E
EZ
029356
–
–
–
–
IVS
067324
Z
062577
010380
10 12 14 16 18 20 22 24
1
2
6.5
3
12
4
15
4
E
EZ
004506
–
Z
073703
078449
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23 25 27 29 31
E
EZ
034102
IVS
069697
Z
10 12 14 16 18 20 22 24 26 28 30 32
064950
012753
1
2
6.5
12
15
E
EZ
004508
Z
080822
083195
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/032
07/033
T Rotary Switches
Control Switches: Reversing Switches, Star-Delta Switches
T Rotary Switches
Control Switches: Reversing Switches, Star-Delta Switches
Circuit diagram
Front
plate no.
Max. three-phase
motor rating (per set of
3 contacts)
Rated unin-
terrupted
current
Iu
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
50–60 Hz
No. of
poles
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
Basic type
For ... insert
mounting form
A
Mounting
form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
M
2
kW
kW
kW
Reversing switches with 0 (Off) position1)
0
2.2
3
2.2
5.5
11
4
–
20
32
63
20
32
63
100
T0-2-8400/...
T3-2-8400/...
T5B-2-8400/...
T0-3-8401/...
T3-3-8401/...
T5B-3-8401/...
T5-3-8401/...
E
EZ
I1
IVS
Z
1
2
3
4
5
6
7
8
1
2
053079
055452
207111
060198
062571
–
E
EZ
000687
I2
207181
–
Z
1
0
2
FS 684
073695
095060
7.5
3
–
E
–
I4
207222
–
Z
092918
092915
0
1
3
4
E
EZ
093420
I1
207132
IVS
098166
Z
1
2
3
5
7
9
2
091047
010366
4
6
8
10
6.5
15
18.5
12
22
30
15
22
30
E
EZ
000694
I2
207188
–
–
–
Z
1
0
2
FS 684
030992
035739
E
–
I4
207227
Z
092296
092293
E
–
I5
207268
Z
096376
096374
With spring-return from both directions to 0
0
3
3
3
4
4
20
32
63
T0-3-8228/...
T3-3-8228/...
T5B-3-8228/...
E
EZ
I1
IVS
Z
1
2
1
2
3
4
5
6
7
8
9
015112
048334
207125
062572
074437
10
6.5
15
12
22
15
22
E
EZ
000695
I2
207186
–
Z
1
0
2
FS 4011
002538
004911
E
–
I4
207225
–
Z
092374
092371
Star-delta switches1)
Y
0
4
5.5
18.5
37
5.5
22
37
20
32
63
T0-4-8410/...
T3-4-8410/...
T5B-4-8410-/...
E
EZ
053080
I1
207140
IVS
064945
Z
1
3
4
5
6
7
8
9
11 13 15
024604
083929
2
10 12 14 16
7.5
22
E
EZ
000721
I2
207195
–
Z
FS 635
0
Y
009657
012030
E
–
I4
207234
–
Z
092052
092049
Reversing Star-delta switches1)
Two-way switches
0
3
3
4
5.5
5.5
22
20
32
T0-5-15876/...
T3-5-15876/...
E
EZ
–
IVS
Z
1
2
3
4
5
6
7
8
9
11 13 15 17 19
Y
Y
000893
000900
000902
000942
10 12 14 16 18 20
7.5
18.5
E
EZ
000797
I2
207537
–
Z
FS 638
016776
019149
Y
0
Y
22
30
37
63
T5B-5-15876/...
E
–
–
–
Z
0
1
3
5
7
9
11 13 15 17 19
Y
Y
214785
214786
2
4
6
8
10 12 14 16 18 20
FS 4017
Y
0
Y
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/034
T Rotary Switches
Control Switches: Multi-Speed Switches, Reversing Multi-Speed Switches
07/035
T Rotary Switches
Control Switches: Multi-Speed Switches, Reversing Multi-Speed Switches
Circuit diagram
Front
plate
no.
Max. three-phase
motor rating (per set of
3 contacts)
Rated unin-
terrupted
current
Iu
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
50–60 Hz
No. of
poles
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
Basic type
For ... insert
mounting form
A
Mounting
form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
M
3
kW
kW
kW
Multi-speed switches1)
Two-speed, non reversing
For 2 separate windings
1
3
5
7
9
11
1
0
3
4
4
20
32
63
T0-3-8451/...
T3-3-8451/...
T5B-3-8451/...
E
EZ
I1
IVS
Z
2
2
4
6
8
10 12
038849
083936
207133
026985
043596
0
1
2
6.5
15
12
22
15
22
E
EZ
000956
I2
207189
–
Z
FS 644
028641
031014
E
–
I4
207228
–
Z
092288
092285
For one tapped winding
1
0
3
3
3
4
4
20
32
63
20
32
63
T0-4-8440/...
T3-4-8440/...
T5B-4-8440/...
T0-4-8441/...
T3-4-8441/...
T5B-4-8441/...
E
EZ
I1
IVS
Z
1
2
3
4
5
6
7
8
9
11 13 15
2
041222
088682
207141
029358
048342
10 12 14 16
6.5
15
3
12
22
4
15
22
4
E
EZ
000959
I2
207196
–
–
Z
0
1
2
FS 644
035760
038133
E
–
I4
207235
Z
092032
092029
0
1
E
EZ
093428
I1
207142
IVS
031731
Z
1
3
5
7
9
11 13 15
2
043595
053088
2
4
6
8
10 12 14 16
6.5
15
12
22
15
22
E
EZ
000960
I2
207197
–
Z
FS 684
1
0
2
042879
045252
E
–
I4
207236
–
Z
092028
092025
Reversing multi-speed switches1)
Two-speed, two directions
For one tapped winding
0
3
3
3
4
4
20
32
63
T0-6-15866/...
T3-6-15866/...
T5B-7-15866/...
E
EZ
–
–
–
IVS
Z
1
2
1
2
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
055460
012747
036477
067326
10 12 14 16 18 20 22 24
6.5
15
12
22
15
22
E
EZ
000964
–
Z
FS 629
2
1
0
1
2
054744
057117
0
E
–
–
Z
1
2
1
2
214788
214789
FS 441
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/036
T Rotary Switches
07/037
T Rotary Switches
Control Switches: Step Switches
Control Switches: Step Switches
Circuit diagram
Front
plate
no.
No. of
poles
Steps
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
Rear mounting
Front IP65
Notes
mounting
Front IP30
Basic type
Mounting
form
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting form Price
Mounting form Price
Mounting form
Article no.
Price
See Price
List
For ... insert
Article no.
Article no.
See Price
List
See Price
List
mounting form Article no.
Step switches1)
One contact closed per step
(without overlap)
With additional 0 (Off) position
1
2
T0-1-8240/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
1
2
3
4
2
1
0
034105
043597
207079
027076
060208
0
1
2
FS 418
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
1
2
3
4
5
6
2
1
1
3
4
T0-2-8241/...
T0-2-8242/...
E
EZ
053089
I1
207107
IVS
057835
Z
1
3
12 A
0
050716
062581
DC-13 32 V per contact 10 A
0
1
2
3
Additional Technical Data a Page 07/090
FS 420
1
3
5
6
7
8
E
EZ
069700
I1
207108
IVS
074446
Z
2
1
3
4
067327
076819
0
2
4
0
1
2
3
4
FS 422
1
3
4
5
6
7
8
9
1
1
5
6
T0-3-8243/...
T0-3-8244/...
E
EZ
I1
IVS
Z
2
1
0
3
4
5
081565
083938
207128
088684
091057
2
10
0
1
2
3
4
5
FS 424
1
3
4
5
6
7
8
9
11
E
EZ
098176
I1
207129
IVS
012749
Z
2
1
3
0
4
095803
015122
2
10 12
5
6
0
1
2
3
4
5
6
FS 426
1
2
3
4
5
6
7
8
9
11
3
3
2
3
T0-3-8280/...
T0-5-8281/...
E
EZ
I1
IVS
Z
2
1
0
10 12
034106
036479
207130
041225
043598
0
1
2
FS 418
2
E
EZ
050717
–
–
IVS
055463
Z
1
3
5
7
9
11 13 15 17
1
3
0
048344
057836
2
4
6
8
10 12 14 16 18
0
1
2
3
FS 420
1
3
5
7
9
11 13 15 17 19 21 23
3
4
T0-6-8282/...
E
EZ
064955
IVS
069701
Z
2
1
3
4
2
4
6
8
10 12 14 16 18 20 22 24
062582
072074
0
0
1
2
3
4
FS 422
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/038
T Rotary Switches
07/039
T Rotary Switches
Control Switches: Step Switches
Control Switches: Step Switches
Circuit diagram
Front
plate
no.
No. of
poles
Steps
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
Rear mounting
Front IP65
Notes
mounting
Front IP30
Basic type
Mounting
form
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting form Price
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
For ... insert
Article no.
See Price
List
mounting form Article no.
Step switches1)
One contact closed per step
(without overlap)
Without 0 (Off) position
1
3
1
1
2
3
T0-1-8220/...
T0-2-8230/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
1
2
031728
095799
207078
055459
086312
2
4
1
2
FS 943
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
1
3
5
6
E
EZ
091058
I1
207105
IVS
095804
Z
3
2
1
2
4
088685
098177
12 A
1
2
3
DC-13 32 V per contact 10 A
FS 404
Additional Technical Data a Page 07/090
1
2
3
4
5
6
7
8
1
1
4
5
T0-2-8231/...
T0-3-8232/...
E
EZ
015123
I1
207106
IVS
019869
Z
2
3
1
4
012750
022242
1
2
3
4
FS 606
1
2
3
4
5
6
7
8
9
E
EZ
029361
I1
207126
IVS
034107
Z
3
2
1
4
5
10
026988
036480
1
2
3
4
5
FS 408
1
2
3
4
5
6
7
8
9
11
1
6
T0-3-8233/...
E
EZ
043599
I1
207127
IVS
048345
Z
3
2
1
4
5
6
10 12
041226
050718
1
2
3
4
5
6
FS 410
3
3
2
3
T0-3-8222/...
T0-5-8270/...
E
EZ
I1
IVS
Z
1
3
5
7
9
11
1
2
048339
015118
207124
060205
088686
2
4
6
8
10 12
1
2
FS 943
1
2
3
5
7
9
11 13 15 17
E
EZ
093432
–
–
IVS
098178
Z
3
2
1
4
6
8
10 12 14 16 18
091059
010378
1
2
3
FS 404
1
3
5
7
9
11 13 15 17 19 21 23
3
4
T0-6-8271/...
E
EZ
017497
IVS
022243
Z
3
4
2
1
015124
024616
2
4
6
8
10 12 14 16 18 20 22 24
1
2
3
4
FS 406
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/040
T Rotary Switches
Control Switches: On-Off Switches, Changeover Switches
07/041
T Rotary Switches
Control Switches: On-Off Switches, Changeover Switches
Circuit diagram
Front
plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board Rear mounting
Notes
mounting
Front IP65
Front IP30
Basic type
For ... insert
mounting form
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
On-Off switches1)
1
1
2
3
4
T0-1-15401/...
T0-1-15402/...
T0-2-15403/...
T0-2-15404/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
0
1
038854
041227
207067
045973
048346
2
0
1
FS 415
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
1
3
4
E
EZ
055465
I1
207068
IVS
060211
Z
0
1
053092
062584
2
12 A
0
1
DC-13 32 V per contact 10 A
FS 415
Additional Technical Data a Page 07/090
1
3
5
6
E
EZ
069703
I1
207088
IVS
074449
Z
0
1
067330
076822
2
4
0
1
FS 415
1
2
3
4
5
6
7
8
E
EZ
083941
I1
207089
IVS
088687
Z
0
1
081568
091060
0
1
FS 415
Changeover switches1)
1
3
0
2
1
2
3
T0-1-15421/...
T0-2-15422/...
T0-3-15423/...
E
EZ
I1
IVS
Z
1
2
4
095806
098179
207069
012752
015125
2
0
1
FS 429
1
2
3
4
5
6
7
8
0
E
EZ
022244
I1
207090
IVS
026990
Z
2
1
019871
029363
2
0
1
FS 429
1
3
5
7
9
11
0
E
EZ
036482
I1
207114
IVS
041228
Z
2
1
034109
043601
2
4
6
8
10 12
2
0
1
FS 429
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/042
T Rotary Switches
07/043
T Rotary Switches
Control Switches: Hand/Auto Switches
Control Switches: Hand/Auto Switches
Circuit diagram
Front
plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board Rear mounting
Notes
mounting
Front IP65
Front IP30
Basic type
For ... insert
mounting form
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Hand/Auto switches1)
Hand/Auto switches with locking arrangement a Page 07/052
With 0 (Off) position
1
3
0
1
2
3
T0-1-15431/...
T0-2-15432/...
T0-3-15433/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
HAND AUTO
2
4
019872
022245
207070
026991
029364
HAND
0
AUTO
FS 1401
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
1
2
3
4
5
6
7
8
0
E
EZ
036483
I1
207091
IVS
041229
Z
HAND AUTO
034110
043602
12 A
HAND
0
AUTO
DC-13 32 V per contact 10 A
FS 1401
Additional Technical Data a Page 07/090
1
2
3
4
5
6
7
8
9
11
0
E
EZ
050721
I1
207115
IVS
055467
Z
HAND AUTO
048348
057840
10 12
HAND
0
AUTO
FS 1401
With spring-return from HAND
1
3
0
1
2
T0-1-15434/...
T0-2-15435/...
E
EZ
I1
IVS
Z
HAND AUTO
062586
018053
207071
069705
072078
2
4
HAND
0
AUTO
FS 1414000
0
E
EZ
003192
I1
218971
IVS
003195
Z
1
2
3
5
6
7
8
HAND AUTO
003191
003196
4
HAND
0
AUTO
FS 1414000
With spring-return from START
1
3
5
7
1
T0-2-15907/...
E
EZ
069304
I1
207095
IVS
076423
Z
0
AUTO HAND
2
4
6
8
066931
078796
START
AUTO
0
HAND
START
FS 1413890
Without 0 (Off) position
1
3
1
2
3
T0-1-15451/...
T0-2-15452/...
T0-3-15453/...
E
EZ
I1
IVS
Z
HAND AUTO
2
4
076824
079197
207072
083943
086316
HAND
AUTO
FS 19334
1
2
3
4
5
6
7
8
E
EZ
093435
I1
207092
IVS
098181
Z
HAND AUTO
091062
010381
HAND
AUTO
FS 19334
1
2
3
4
5
6
7
8
9
11
E
EZ
017500
I1
207116
IVS
022246
Z
HAND AUTO
015127
024619
10 12
HAND
AUTO
FS 19334
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/044
T Rotary Switches
07/045
T Rotary Switches
Control Switches: Spring-Return Switches
Control Switches: Spring-Return Switches
Circuit diagram
Front
plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
Notes
Basic type
For ... insert
mounting form
Mounting
form
Article no.
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting form Price
Mounting form
Article no.
Price
See Price
List
Mounting form Price
Article no.
Article no.
See Price
List
See Price
List
On-switch (make contact)1)
Spring-return from position 1
1
1
2
3
T0-1-15321/...
T0-1-15322/...
T0-2-15323/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
1
2
086317
088690
207064
093436
095809
1
FS 4721
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
1
3
4
E
EZ
012755
I1
207065
IVS
017501
Z
1
2
010382
019874
12 A
1
DC-13 32 V per contact 10 A
FS 4721
Additional Technical Data a Page 07/090
1
3
5
6
E
EZ
026993
I1
207087
IVS
031739
Z
1
024620
034112
2
4
1
FS 4721
On-Off switch1)
Spring-return from positions 0 and 1
1
3
1
1
T0-1-15366/...
T0-1-15511/...
E
EZ
I1
IVS
Z
0
1
2
4
081572
083945
207066
088691
091064
0
1
FS 456
On-Off switch1)
Spring-return from START
1
3
1
E
EZ
022248
I1
207073
IVS
026994
Z
START
0
019875
029367
2
4
0
1
FS 147767
START
1
3
5
6
7
8
1
2
T0-2-15512/...
T0-3-15513/...
T0-2-8177/...
E
EZ
I1
IVS
Z
START
0
2
4
034113
036486
207093
041232
043605
0
1
FS 147767
START
1
2
3
4
5
6
7
8
9
11
1
3
E
EZ
050724
I1
207117
IVS
055470
Z
START
0
10 12
048351
057843
0
1
FS 147767
START
0
See K115
E
EZ
017503
I1
207101
IVS
022249
Z
1
2
3
4
5
6
7
8
1
2
015130
024622
START START
FS 140660
START
1
0
2
START
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/046
T Rotary Switches
Control Switches: Universal Control Switches, Coding Switches, Series Switches
07/047
T Rotary Switches
Control Switches: Universal Control Switches, Coding Switches, Series Switches
Circuit diagram
Front
plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
Notes
Basic type
Mounting
form
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
Mounting form
Article no.
Price
See Price
List
For ... insert
mounting form Article no.
Universal control switches1)
Stay-put switches with 3 positions
1 contact closed in each position; in addition:
1 contact closed in positions 0 and 1
1 contact closed in positions 0 and 2
1 contact closed in positions 1 and 2
1
3
5
7
9
11
–
–
T0-3-15391/...
T0-3-15394/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
0
2
1
029365
031738
207112
036484
038857
2
4
6
8
10 12
2
0
1
FS 429
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
As above, but with spring-return from positions 1 and 2
1
3
5
7
9
11
E
EZ
074452
I1
207113
IVS
079198
Z
0
2
12 A
1
072079
081571
2
4
6
8
10 12
DC-13 32 V per contact 10 A
2
0
1
Additional Technical Data a Page 07/090
FS 458
Coding switches1)
With complete rotation in both directions
Dual
BCD
CODE
T0-4-15602/...
E
EZ
031741
I1
207134
IVS
036487
Z
3
9
2
4
8
1
2
3
4
5
6
7
8
9
11 13 15
1
0
5
029368
038860
6
10 12 14 16
7
0
1
2
3
4
5
6
7
8
9
FS 312
Series switches1)
With 0 (Off) position
(heater switches)
1
3
1
T0-1-91/...
E
EZ
074455
I1
207080
IVS
079201
Z
1
2
072082
081574
2
4
0
0
1
2
FS 614
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/048
T Rotary Switches
Control Switches: Instrument Selector Switches
07/049
T Rotary Switches
Control Switches: Instrument Selector Switches
Circuit diagram
Front
plate
no.
No. of poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface
mounting 2)
IP65
Service distribution board
mounting
Front IP30
Rear mounting
Front IP65
Notes
Basic type
Mounting
form
Price
See Price
List
Mounting
form
Article no.
Price
See Price
List
Mounting form Price
Mounting form
Article no.
Price
See Price
List
Mounting form Price
For ... insert
Article no.
Article no.
See Price
List
See Price
List
mounting form Article no.
Voltmeter selector switches1)
L2-L3
3 x phase to phase
T0-2-15920/...
E
EZ
I1
IVS
Z
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
1
2
3
4
5
6
7
8
L1-L2 L3-L1
0
with 0 (Off) position
038861
041234
207098
029452
048353
FS 1410755
0
L1+L2
L2+L3
L3+L1
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
L2-L3
3 x phase to phase
without 0 (Off)
position
T0-2-15922/...
T0-2-15921/...
E
EZ
055472
I1
207100
IVS
060218
Z
1
2
3
4
5
6
7
8
L3-L1
L1-L2
12 A
053099
062591
DC-13 32 V per contact 10 A
Additional Technical Data a Page 07/090
FS 164854
L1-L2
L2-L3
L3-L1
1
3
5
7
L2-N
L1-N L3-N
0
3 x phase to N with
E
EZ
069710
I1
207099
IVS
074456
Z
2
4
6
8
0 (Off) position
067337
076829
0
L1-N
L2-N
L3-N
FS 1410757
0
3 x phase to phase + T0-3-8007/...
3 xphase to N
E
EZ
098186
I1
207120
IVS
012759
Z
L1-L2
L2-L3
L3-L1
L1-N
L2-N
L3-N
1
2
3
5
7
9
11
095813
015132
4
6
8
10 12
with 0 (Off) position
FS 1410759
L3-L1
L2-L3
L1-L2
0
L1-N
L2-N
L3-N
L2-L3
3 x phase to phase + T0-3-15924/...
3 x phase to N
E
EZ
022251
I1
207119
IVS
026997
Z
L1-L2
L3-L1
1
3
5
7
9
11
019878
029370
L3-N
L1-N
2
4
6
8
10 12
L2-N
without 0 position
with complete
FS 164721
L1-L2
L2-L3
L3-L1
L1-N
L2-N
L3-N
rotation in both
directions
Ammeter selector switches1)
With complete rotation in both directions
Measurement via current transformers
0
With 0 (Off) position
T0-3-8048/...
E
EZ
036489
I1
207122
IVS
041235
Z
1
2
3
4
5
6
7
8
9
11
L3
L1
034116
043608
10 12
L2
FS 9440
0
L1
L2
L3
Voltmeter and ammeter selector switches1)
With complete rotation in both directions
Measurement via current transformers
(For other circuits a catalogue K115)
With 0 (Off) position
T0-3-8030/...
E
EZ
013402
I1
207121
IVS
013404
Z
1
1
2
3
4
5
6
7
8
9
11
013401
013406
0
0
10 12
2
0
1
0
2
FS 928
Standard pack: 1 off
Standard pack: 1 off
1)
2)
Notes
With black thumb-grip and grey front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/050
T Rotary Switches, P Switch-Disconnectors
Switches with Locking Arrangements
07/051
T Rotary Switches, P Switch-Disconnectors
Switches with Locking Arrangements
Circuit diagram
Front
plate
no.
No. of
poles
Max. three-phase
motor rating (per set of
3 contacts)
Rated
Flush mounting
IP65
Surface mounting 3)
IP65
Rear mounting
IP65
Notes
uninter-
rupted
current
50–60 Hz
AC-3
220 V 380 V 660 V
230 V 400 V 690 V
240 V 440 V
Iu
Type
Article no.
Price
See Price
List
Type
Article no.
Price
See Price
List
Type
Article no.
Price
See Price
List
kW
kW
kW
A
Std. pack
Switches with locking arrangements, KMS1 lock mechanism
Panic switches without Emergency-Stop function1)
With SVA cylinder lock
Key withdrawable in positions 0 and 1
When the key is withdrawn in position 1, the switch
can still be switched Off, but cannot be switched back On again without the key
ON
3
3
4
4
20
25
32
32
T0-2-1/E/SVA(S)
T0-2-1/I1/SVA(S)
–
–
–
–
1 off
1
2
3
4
5
6
OFF
050977
207084
E
4
5.5
11
11
7.5
15
15
P1-25/E/SVA(S)
050966
P1-32/E/SVA(S)
044977
P1-25/I2/SVA(S)
207305
P1-32/I2/SVA(S)
207326
D
F
FS 908
C
G
L
5.5
5.5
H
K
0
B
R
30
330
300
270
240
60
90
120
T3-2-1/E/SVA(S)
050983
T3-2-1/I2/SVA(S)
207173
315 45
225 135
A
J
On-Off switch without Emergency-Stop function1)
With SVA cylinder lock
210
150
Key withdrawable in 0 position only (code letter A)
180
ON
3
3
4
4
20
25
32
32
T0-2-1/E/SVA(A)
T0-2-1/I1/SVA(A)
T0-2-1/Z/SVA(A)
1
2
3
4
5
6
Q
050976
207083
050978
OFF
P
M
N
4
5.5
11
11
7.5
15
15
P1-25/E/SVA(A)
050965
P1-25/I2/SVA(A)
207304
P1-25/Z/SVA(A)
050969
FS 908
Code letters for lockable switch
positions
Letter S for panic lock with FS908GE
5.5
5.5
P1-32/E/SVA(A)
050970
P1-32/I2/SVA(A)
207325
P1-32/Z/SVA(A)
050973
T3-2-1/E/SVA(A)
050982
T3-2-1/I2/SVA(A)
207172
T3-2-1/Z/SVA(A)
050984
Panic switches with Emergency-Stop function2)
With SVA cylinder lock
Key withdrawable in positions 0 and 1
When the key is withdrawn in position 1, the switch
can still be switched Off, but cannot be switched back On again without the key
3
3
4
4
20
25
32
32
T0-2-1/E/SVA(S)-RT
T0-2-1/I1/SVA(S)-RT
–
–
–
–
1
2
3
4
5
6
1
228971
207085
0
4
5.5
11
11
7.5
15
15
P1-25/E/SVA(S)-RT
050967
P1-25/I2/SVA(S)-RT
207306
FS 908 GE
5.5
5.5
P1-32/E/SVA(S)-RT
050971
P1-32/I2/SVA(S)-RT
207327
T3-2-1/E/SVA(S)-RT
044972
T3-2-1/I2/SVA(S)-RT
207174
Panic switches with Emergency-Stop function2)
With SVC padlocking feature
Locking slide can be padlocked in positions 0 and 1. When the locking slide is padlocked in position 1, the
switch can still be switched Off, but cannot be switched back On again without first removing the padlock.
Lockable using up to 3 padlocks.
3
3
4
4
20
25
32
32
T0-2-1/E/SVC(S)-RT
T0-2-1/I1/SVC(S)-RT
–
–
–
–
1
3
5
1
044973
207086
0
2
4
6
4
5.5
11
11
7.5
15
15
P1-25/E/SVC(S)-RT
044974
P1-25/I2/SVC(S)-RT
207307
FS 908 GE
5.5
5.5
P1-32/E/SVC(S)-RT
044975
P1-32/I2/SVC(S)RT
207328
T3-2-1/E/SVC(S)-RT
044976
T3-2-1/I2/SVC(S)-RT
207175
On-Off switches without Emergency-Stop function1)
With S-T0 key operation
Key withdrawable in position 0 only (code letter A)
4)
ON
2
2.2
2.2
–
20
T0-1-102/EZ/S
014933
T0-1-102/I1/S
207063
T0-1-102/Z/S
014971
1
2
3
4
OFF
FS 908
1)
2)
3)
Notes
With black thumb-grip and grey front plate
To IEC/EN 60204-1; with red thumb-grip and yellow front plate
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Degree of protection IP53
4)
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/052
T Rotary Switches
Switches with Locking Arrangements
07/053
T Rotary Switches
Switches with Locking Arrangements
Circuit diagram
Front
plate
no.
Rated
Flush mounting
Front IP65
Surface mounting1)
IP65
Rear mounting
Front IP65
Notes
uninter-
rupted
current
Iu
Type
Article no.
Price
See Price
List
Type
Article no.
Price
See Price
List
Type
Article no.
Price
See Price
List
A
Std. pack
Switches with locking arrangements, KMS1 lock mechanism
Hand/Auto switches with
SVA cylinder lock
Suitable for actuating electronic devices
Rated uninterrupted current Iu 20 A
Rated operational current Ie
AC-15
Key withdrawable in all positions
When the key is withdrawn in the HAND position,
220 – 240 V
380 – 415 V
AC-21A
6 A
4 A
then START can be actuated without first removing the padlock, but not position 0
(only admissible with separate Off switch)
12 A
DC-13 32 V per contact 10 A
Additional Technical Data a Page 07/090
Rotary switches with an SVA locking arrangement can also
be used as Operating Mode Selector Switches for the
purposes of EU Machine Directive 89/392 (Minimum
switching angle: 60°)
1
3
4
5
6
7
8
20
32
T0-2-15907/E/SVA(C,E,G-J)
T0-2-15907/I1/SVA(C,E,G-J)
–
–
1 off
0
AUTO HAND
050979
207096
2
START
AUTO
0
HAND
START
T3-2-15907/E/SVA(C,E,G-J)
050985
T3-2-15907/I2/SVA(C,E,G-J)
207176
FS 1413890
Code letters for lockable
switch positions
Hand/Auto switches with
SVC padlocking feature
Locking slide can be padlocked in all positions.
E
When the locking slide is padlocked in the HAND position,
then START can be actuated without the key,
D
F
C
G
L
but not position 0 (only admissible with separate Off switch)
H
K
0
B
R
30
330
300
270
240
60
90
120
315 45
225 135
1
3
4
5
6
7
8
A
20
32
T0-2-15907/E/SVC(C,E,G-J)
T0-2-15907/I1/SVC(C,E,G-J)
T0-2-15907/Z/SVC(C,E,G-J)
J
0
AUTO HAND
2
044996
207097
050980
START
AUTO
0
HAND
START
T3-2-15907/E/SVC(C,E,G-J)
044997
T3-2-15907/I2/SVC(C,E,G-J)
207177
T3-2-15907/Z/SVC(C,E,G-J)
050986
210
150
FS 1413890
180
Q
P
M
N
1)
Notes
Enclosure designed for metric cable glands to EN 50 262, cable glands a Page 07/070
Contactor interlocking circuits
SOND 27
SOND 28
SOND 29
SOND 30
Control section for standard contactor interlocking
circuits.
F0
F0
F2
S0
F0
F2
F0
If a standard switch is to contain one of the contactor
interlocking circuits as well, it can be ordered using
another circuit number from catalogue K115, or as a non-
standard switch.
K1M
F2
S0
S1
K1M
KM1
F2
S0
K1M
Q1
0 1
Q1
0
Q1
0
Q1
0 1
S0
Control
section
SOND 27
2
2
Control
section
SOND 30
1
1
2
Control
section
SOND 28
Control
section
SOND 29
2
K1M
K1M
K1M
K1M
K1M
S1
K1M
The electrical interlocking of rotary switch and contactor
makes possible a wide range of control functions.
For example: remote disconnection via a stop switch,
overload protection via overload relays, protection
against automatic restarting after a power failure or
overload, and Off position interlocking, etc.
Power
section
without
mains
disconnection
Power
section
with
mains
disconnection
K1M
K1M
Power
section
Power
section
Contact
sequence as
required
Contact
sequence as
required
Contact
sequence as
required
Contact
sequence as
required
M
3~
M
3~
M
3~
M
3~
Mains disconnection only by contactor.
Mains disconnection by contactor and
Mains connection by contactor, onlywith the Mains connection by contactor, only with the
Restarting possible only with the rotary switch in rotary switch together
rotary switch in the Off position
(Off position interlock)
rotary switch in a run position
Each change in the switch position causes the
contactor to drop out
the Off position.
Application: primarily for star-delta circuits
(only at 60 or 90° switching angles)
Restarting: as SOND 27
Application: primarily for star-delta and
changeover circuits
Application: star-delta, changeover and
multi-speed circuits
Application: changeover and multi-speed
circuits
(only at 60 or 90° switching angles)
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/054
T Rotary Switches, P Switch-Disconnectors
07/055
T Rotary Switches, P Switch-Disconnectors
Front Plates
Front Plates
Standard front plates
Emergency-Stop front plates
Blank plates
Non-standard front plates
Non-standard front plates
Switch size
Dimensions
Yellow
Can be engraved
1
0
Type
Price
Std. pack
Type
Price
Std. pack
Type
Price
Std. pack
Type
Price
Std. pack
Height of letters
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
State the front
plate no. required
F 2 characters
> 2 characters
mm
mm
mm
Standard Front plates
T0, T3, P1
45 x 45
FS...-T0
10 off
10 off
FS908 GE-T0
5 off
5 off
FS980-T0
50 off
50 off
10 off
50 off
FS-SOND-ERSTBESTELLUNG-T01)
5 off
5 off
5 off
5 off
4
3
(for frame size 48 x 48)
903197
003198
003199
225355
P3, T5, T5B
TM
84 x 84
(for frame size 88 x 88)
29 x 29
(for frame size 30 x30 )
FS...-P3
995545
–
–
FS908 GE-P3
031475
–
–
FS980-P3
043340
FS980-TM-E
071438
FS-SOND-ERSTBESTELLUNG-P32)
225356
FS-SOND-TM-E
092829
8
5
3.5
3.5
2.5
2.5
FS980-TM-EZ
073811
FS-SOND-TM-EZ
095202
1) = first order; for subsequent orders use FS...-T0
2) = first order; for subsequent orders use FS...-P3
Standard front plates
Non-standard front plates
The standard front plates illustrated should be used for non-standard switches where possible. Standard catalogue front plates for standard switches can be exchanged
on request with order, for those illustrated here, at no extra charge (not applicable to T6, T8 and TM), provided the switching angles, the number of switch positions, and
the location of the 0 (Off) position match.
Inscription to order (note maximum number of characters per field).
The FS number is sufficient for reordering.
For non-standard T0, T3 and T5(B) switches, the front plate is included in the price.
For standard switches, the front plate is included in the price for orders exceeding 49 off.
a Page 07/113
Example: T0-1-8210/E+FS161570
Switching angle 90°
ON
1
1
0
2
EIN
STOP START
SLOW FAST
0
1
AUS
EIN
AUF
UP
DOWN
HAND
AUTO
AUF
ZU
AB
1
2
1
AUS
STOP
1
0
OFF
HEIZUNG-
NOTSCHALTER
908
9508
902
190719
193935
907
945
1992
190334
943
19334
190550
19143
193975
190431
1
0
0
0
ON
ON
OFF
2
1
1
1
0
OFF
AUTO
AUS
OFF
1
2
0
1
3
1
0
OFF
OFF
ON
ON
2
1+2
0
0
2
3
1
L3
L1
L3
L1
ZU
AUF
0
2
1
2
1
2
1
3
0
2
0
0
1
2
T
R
2
L2
1
2
3
1
OFF
S
4
L2
2
0
910
953
192190
904
926
1957
192191
923
928
9441
193840
912
911
906
9440
935
19589
1922
Switching angle 60°
Standard front plates
arranged in their numerical sequence:
SLOW
START
0
NOT-
HALT
1
2
Y
0
0
AUS
AUS
HAND
OFF
OFF
0
HAND
AUTO
0
HALT
LINKS RECHTS
1
STOP
FAST
STOP
RUN
NETZ STROM
1
2
0
1
2
2
1
1
2
1
0
AUF
AB
AUTO
AUTO
AUTO
HAND
HAND
AUF
AB
3
9
3
9
3
4
4
4
4
4
4
4
3
9
3
3
4
3
4
3
4
4
2
4
8
3
3
5
3
5
2
4
8
2
4
5
2
2
1
3
5
3
5
3
5
3
5
3
5
3
2
4
8
2
4
8
2
2
1
1
5
6
2
1
5
2
6
2
2
6
6
2
6
1
1
1
5
1
2
2
2
1
5
5
1
5
1
6
5
1
7
1
7
1
7
7
6
0
6
0
6
0
6
6
0
6
0
7
1
1
0
0
1
0
0
12
11
8
8
11
10
8
8
7
7
7
7
8
7
611
601
1601
644
STOP
16052
635
L2-N
16616
L2-L3
684
621
161629
161570
161359
161358
1610
1614
1673
1617
9
9
11
9
9
10
10
10
10
STOP
OFF
FORW.
OFF
2
1
2
0
Y
2
3
1
2
LOW MED.
2
3
AUTO
MAN
FORW. REV.
L1-N
L1-L2
L3-L1
301
302
303
304
305
307
308
309
310
311
312
313
314
315
316
317
318
REV.
SLOW FAST
L3-N
1
3
0
3
OFF
HIGH
1
4
0
3
3
3
0
2
2
2
2
2
0
0
3
4
3
2
3
2
8
1
2
1
4
5
4
2
1
3
3
3
4
5
3
1
1
2
1
2
1
2
4
1
1
1
1
1
0
3
2
4
2
1
1
2
1
1
5
1
1
4
4
0
4
2
3
5
0
0
0
0
0
1627
1628
1662
1665
655
164855
164854
614
604
616
160772
606
6034
6
6
5
5
7
6
7
7
6
6
START
L2-L3
L1-L2
STOP
SLOW SLOW
STOP
0
0
0
0
S-T
0
0
1
2
1
2
2
3
START START
L3-L1
L1-N
T-R
1
R-S
3
4
1
2
2
1
2
Y
2
1
3
4
1
2
1
2
Y
Y
402
415
416
429
404
406
408
410
412
414
418
420
422
424
426
0
428
441
0
3
0
3
1
4
0
T-O
R-O
FAST
FAST
1
L3-N
RUN
RUN
Y
0
4
5
0
0
6
5
0
0
0
0
1
1
2
4
1
S-O
1
0
L2-N
2
3
2
3
1
2
1
2
2
3
1
2
3
0
1
2
1
1
1
2
1
1
1
1
0
2
2
1
2
3
2
4
2
2
2
1
1
4
2
0
0
2
1
4
0
3
164222
667
645
629
161002
638
161683
618
620
610
640
6010
164721
661
3
3
6
5
4
455
458
461
462
496
601
S-T
604
606
611
614
616
0
449
453
0
456
Y
459
610
2
618
ON
Switching angle 45°
0
0
1
0
0
2
0
2
2
0
1
2
T-R
R-S
T-O
2
1
3
4
1
3
1
3
4
2
1
2
1
1
1
2
1
2
0
Y
Y
2
R
1
0
STOP
0
0
0
1
1
3
1
3
1
0
1
STOP
START
OFF
HAND
AUTO
0
0
1
1
0
1 2
OFF
0
1
1
0
2
2
1
ON
1
2
1
HAND AUTO
2
R-O
1
2
4
5
S-O
0
START
4
0
621
635
644
655
684
902
904
HALT
906
907
908
620
629
1
638
1
640
1
645
661
0
667
416
402
415
HALT
142003
147472
141883
455
141879
4721
4722
4723
496
41409
429
OFF
1401
AUS
OFF
HAND
0
HALT
0
1
0
0
1
0
1
2
HAND AUTO
AUTO
1
HAND
AUTO
2
1
LINKS RECHTS
ZU-
VOR.
AUS
LANG- SCHNELL
AUS
OFF
0
HALT
STOP
FORW. REV.
1
0
1
3
0
2
RUCK
1
0
2
0
0
0
0
1
2
0
1
2
T
START START
HAND AUTO
AUTO
HAND
HAND
AUTO
0
2
2
HAND
AUTO
LINKS RECHTS
2
1
ZU-
VOR.
SAM
RUCK
START
2
2
911
0
3
912
0
0
1
1
S
2
910
923
AUS
LANG- SCHNELL
SAM
926
HAND
928
935
AUS
943
945
953
980
STOP
1401
STOP
1403
1404
1409
1411
1420
1411
1420
1475
0
1404
0
1403
0
141538
147767
461
1
4026
462
4117
1414000 1413905
OFF
FORW.
AUS
OFF
OFF
OFF
AUTO
ON
0
1 2
1
AUS
EIN
FORW. REV.
AUTO
MAN
REV.
SLOW
FAST
AUTO
LINKS RECHTS
2
1
0
0
STOP
0
0
0
2
3
2
2
3
AUS
EIN
AUS
EIN
OFF
OFF
HAND
AUTO
ZU
AUF
HAND
AUTO
AUTO
HAND
1
AUTO
HAND
START
3
3
4
1
2
2
1
0
1
1
2
1
1
0
4
2
1
LINKS RECHTS
AUS
EIN
AUF
ZU
TRIP
AUS
EIN
STOP START
FORW.
REV.
CLOSE
1
0
0
AUS
ON
RAISE LOWER
1475
1601
1610
1614
1617
1627
1628
0
1662
0
1665
1673
1922
1957
1
1992
1423
1426
1446
4011
458
14988
4011
1426
147474
1413903
1446
456
0
1423
14510
141537
1413890
418
404
420
406
422
S-O
STOP
FORW.
S-T
0
1
0
0
0
Y
0
0
1
0
0
START
R-S
0
T-R
R-O
S-O
1
R-S
R-O
0
T-O
REV.
2
1
2
1
Y
Y
Y
STOP
FORW.
0
3
0
0
2
3
2
0
0
0
3
0
2
1
L3
L1
S-T
T-R
STOP START
1
2
0
0
START START
3
REV.
4
2
4
1
1
1
1
2
1
0
3
4
5
2
4
1
3
2
1
1
1
0
3
START START
2
1
1
1
Y
Y
HEIZUNG-
NOTSCHALTER
Y
T-O
1
5
2
2
2
2
1
1
5
4
1
5
2
2
4
4
2
2
0
START START
0
L2
START START
START START
0
6
5
5
3
3
7
6
6
7
6
4017
0
4026
SLOW
4117
START
4721
4722
4723
142010
6034
9440
STOP
9441
9508
14196
6010
14195
HAND
14510
14712
OFF
ON
14944
0
4017
408
441
453
L2-N
459
1409
140660
L1-N
14712
142074
424
0
410
OFF
426
OFF
412
0 START
449
428
0
0
0
OFF
0
STOP
STOP
AUF
AB
HAND AUTO
R-S
S-T
R-S
S-T
T-R
START START
1
2
1
2
STOP
FAST
STOP
RUN
AUTO
L2-L3
L1-L2 L3-L1
0
0
OFF
OFF
S-O
S-T
L1-L2
L2-L3
L3-L1
0
3
AUF
ZU
L1-L2
L2-L3
L3-L1
L1-N
L2-N
L3-N
L3
L1
FORW. REV.
START
START
2
1
TRIP
CLOSE
R-S
S-T
R-O
S-O
R-S
S-T
R-S
2
R-O
T-O
R-S
T-R
4
L1-N
L3-N
0
L1-N
0
L1-L2
L2-L3
L1-N
L2-N
L3-N
L1-L2
L2-L3
L1-L2
L2-L3
L3-L1
L2-N
START START
T-R
S-T
T-R
L3-L1
L1-L2
L2-L3
L3-N
L1-N
1
1
0
L1-L2
L3-N
5
0
0
L2
8
6
L3-L1
L3-L1
T-R
T-O
T-R
7
L2-N
14988
OFF
16052
16616
19143
STOP
19334
19589
HALT
41409
141538
141879
L2-L3
141883
L2-N
142003
147472
140055
140660
STOP
START START
141537
START
1
0
142074
147474
14196
142010
414
1410757
1410755
14195
1410756 1410758 1410759
147479
14944
1410763
140055
194321
194323
0
L2-L3
1
HALT
LINKS RECHTS
0
NOT-
EIN
LOW
OFF
MED.
HIGH
STOP START
SLOW FAST
AUF
ZU
L3-L1
L1-L2
L2-L3
L3-L1
L1-N
L2-N
L3-N
SLOW SLOW
L1-L2
L3-N
L1-L2
L3-L1
L3-N
L1-N
NETZ STROM
START
AUF
AB
AUS
0
AB
AUF
FAST
FAST
L1-N
RUN
RUN
Switching angle 30 °
L2-N
147767
160772
161358
161359
OFF
161570
OFF
161629
L2-L3
L1-L2 L3-L1
0
164854
164855
OFF
190334
190431
0
190550
190719
147479
OFF
161002
1
161683
164222
L2-N
L1-N L3-N
0
164721
L1-N
3
3
3
3
4
3
3
4
3
4
4
4
4
5
3
9
4
3
2
4
4
3
5
2
4
2
4
3
5
3
2
1
4
8
2
3
3
5
2
4
3
5
3
5
2
4
8
3
5
6
2
4
8
2
4
5
1
0
5
1
0
5
2
1
6
1
0
5
2
1
6
2
1
6
5
2
1
6
7
1
2
1
1
0
1
0
2
1
5
2
5
2
0
6
1
L1-L2
L2-L3
0
0
OFF
OFF
AUTO
HAND
1
UP DOWN
L1-L2
L2-L3
L3-L1
L1-N
L2-N
L3-N
0
1
0
6
6
7
6
7
6
1
7
0
6
7
0
6
AUTO HAND
HAND AUTO
1
L1-L2
L2-L3
L3-L1
0
L1-N
0
L1-L2
L1-L2
L2-L3
L3-L1
L2-N
L3-N
8
12
8
9
11
10
7
7
8
8
7
7
8
7
ON
ON
1+2
STOP
L3-L1
L1-L2
L2-L3
L3-N
L1-N
L3-L1
1
2
0
9
10
11
10
9
11
START
9
8
10
10
9
RAISE LOWER
9
2
OFF
L2-N
318
309
317
308
316
307
315
314
305
313
304
312
303
311
302
310
301
192190
192191
193840
193935
193975
1413905 1414000
194321
194323
1410755 1410756 1410757 1410758 1410759 1410763 1413890 1413903
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/056
T Rotary Switches, P Switch-Disconnectors
07/057
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Type suffix
Price
Std. pack Type
Price
Std. pack
Type suffix
Price
Std. pack Type
Article no.
Price
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
See Price
List
Std. pack
When ordered
with basic unit
When ordered
separately
When ordered
with basic unit
When ordered separately
Add-on front plates, clip-on
For use with front plates and for padlocking features. They comprise
a black label mount and an insert plate.
Blank, can be engraved
T.../I2/SVB(-SW) and
P.../I2/SVB(-SW)
–
ZFS60-T0
25 off
25 off
–
ZFS60-P3
25 off
25 off
ZFS...-T0 and ZFS...-P3 can be used for any T... and P...
019924
022297
switches, as required.
except...I1, 2.../IVS
Dimensions with frame W x H = 48 x 17 mm
Dimensions with frame W x H = 88 x 27 mm
T..., P..., except.../I1, 2, 3 .../IVS
With inscription:
“Main switch - Open only in the
Off position“
T.../E, T.../Z, P.../E, P.../Z
61/62 = German/English
63 = French
+ZFS61/62-T0
065740
1off
ZFS61/62-T0
030170
+ZFS61/62-P3
065742
1off
ZFS61/62-P3
065739
ZFS61/62-... included as standard with
T.../EA/SVB, P.../EA/SVB
T.../V/SVB, P.../V/SVB
+ZFS63-T0
065741
ZFS63-T0
047424
+ZFS63-P3
065743
ZFS63-P3
047423
64 = Bulgarian
65 = Danish
+ZFS64-T0
205501
ZFS64-T0
205535
+ZFS64-P3
205518
ZFS64-P3
205552
66 = Finnish
67 = Dutch
68 = Italian
+ZFS65-T0
205502
+ZFS66-T0
205503
ZFS65-T0
205536
ZFS66-T0
205537
+ZFS65P3
205519
+ZFS66-P3
205520
ZFS65P3
205553
ZFS66-P3
205554
69 = Greek
70 = Norwegian
71 = Polish
72 = Portuguese
73 = Romanian
74 = Russian
+ZFS67-T0
065744
ZFS67-T0
065750
+ZFS67-P3
065747
ZFS67-P3
065753
75 = Swedish
76 = Serbo-Croat
77 = Spanish
+ZFS68-T0
ZFS68-T0
+ZFS68-P3
ZFS68-P3
065745
065751
065748
065754
+ZFS69-T0
205504
ZFS69-T0
205538
+ZFS69-P3
205521
ZFS69-P3
205555
78 = Czech
79 = Turkish
80 = Hungarian
81 = Afrikaans
+ZFS70-T0
205505
ZFS70-T0
205539
+ZFS70-P3
205522
ZFS70-P3
205556
+ZFS71-T0
205506
ZFS71-T0
205540
+ZFS71-P3
205523
ZFS71-P3
205557
+ZFS72-T0
205507
ZFS72-T0
205541
+ZFS72-P3
205524
ZFS72-P3
205558
+ZFS73-T0
205508
ZFS73-T0
205542
+ZFS73-P3
205525
ZFS73-P3
205559
+ZFS74-T0
205509
ZFS74-T0
205543
+ZFS74-P3
205526
ZFS74-P3
205560
+ZFS75-T0
205510
ZFS75-T0
205544
+ZFS75-P3
205527
ZFS75-P3
205561
+ZFS76-T0
205511
ZFS76-T0
205545
+ZFS76-P3
205528
ZFS76-P3
205562
+ZFS77-T0
065746
ZFS77-T0
065752
+ZFS77-P3
065749
ZFS77-P3
047422
+ZFS78T0
205512
ZFS78T0
205546
+ZFS78-P3
205529
ZFS78-P3
205563
+ZFS79-T0
205513
ZFS79-T0
205547
+ZFS79-P3
205530
ZFS79-P3
205564
+ZFS80-T0
205514
ZFS80-T0
205548
+ZFS80-P3
205531
ZFS80-P3
205565
+ZFS81-T0
205515
ZFS81-T0
205549
+ZFS81-P3
205532
ZFS81-P3
205566
Label mounts, black
T.../I2/SVB(-SW) and
P.../I2/SVB(-SW)
–
ZFSX-T0
024670
25 off
–
ZFSX-P3
027043
25 off
ZFSX...-T0 and ZFSX...-P3 can be used for any T... and P...
switches, as required.
ZFSX...-T0: dimensions with frame W x H = 48 x 17 mm
ZFSX...-P3: dimensions with frame W x H = 88 x 27 mm
except...I1, 2.../IVS
T..., P..., except.../I1, 2, 3 .../IVS
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/058
T Rotary Switches, P Switch-Disconnectors
07/059
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Key withdrawal
Type suffix
Price
Key withdrawal
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Std. pack Notes
When ordered
with basic unit
When ordered separately
S-T0 key operated lock mechanism, Front IP53
Includes two keys
KMS 1 lock mechanism
T0-.../E, .../I1, .../Z
Up to 6 contact units
T3-.../E, .../I2, .../Z
Up to 5 contact units
P1-.../E, .../I2, .../Z
Key withdrawal
positions are
programmed ex-
works to match
the switch
+S-T0
Key withdrawal
positions can be
programmed by
the user
S-T0
1 off
S-T0 can be used for P1-..., T0-1... to
T0-6... and T3-1... to T3-5... switches.
Individual lock mechanism, not suitable for master key systems
001753
086709
The key replaces the thumb-grip. Switching is not possible with-
out the key. The switch position indicator is on the lock. In
standard applications, the key can be withdrawn in any position,
on switches with FS908, only in the Off position. New positions
for key withdrawal can be selected (even retrospectively) by
fitting VR-T0 locking cams.
KMS 2–101) lock mechanisms
+S-SOND(KMS...)-T0
903210
S-SOND(KMS...)-T0
903207
KMS 201–4001) lock mechanisms
Individual lock mechanisms, not suitable for master key systems
There is no master key for KMS...- lock mechanisms
(SAE) = Individual lock mechanism
supplied with a security certificate
+S-SOND(SAE)-T0
003212
S-SOND(SAE)-T0
003209
The switching angle is determined by the switch.
When retrofitting the S-T0, use the front plate of the switch.
Lock mechanism: standard KMS 1 (CES lock)
(SA...) = Master key system (with master key) supplied with a security
+S-SOND-(SA...)-T0
914737
S-SOND-(SA...)-T0
991023
certificate.
See also note below.2)
SVA-T3 cylinder lock, Front IP65
Includes two keys
SVA-T3 can be fitted to T0, T3 and P1 switches.
Switching is carried out using the thumb-grip.
The switch is locked by turning the key; the key is withdrawable.
In standard applications, all positions are lockable.
Lock mechanism: standard KMS 1 (CES lock). Individual positions
or ranges can be locked (also with VR-T3 fitted by the user). The
key cannot be withdrawn in positions which are not lockable.
Where ranges are locked, switching without the key is possible
only within a locked range.
The lockable positions or ranges are shown below; use the code
letters to state your selection on the order:
Example 1: SVA(A)-T3 = Only position A lockable
Example 2: SVA(A, E)-T3 = Positions A and E lockable
Example 3: SVA(A–J)-T3 = Range A to J lockable
Example 4: SVA(S)-T3 = Main switches, for use as Emergency-
Stop devices to IEC/EN 60 204-1; with red handle and yellow front
plate as panic lock version, lockable in positions A and E;
switching is still possible from E to A, but not from A to E.
When retrofitting the SVA-T3, use the front plate of the switch.
With letter S for panic lock, use FS908GE. Ordering example:
P1-25/I2-RT+SVA(S)-T3
Key withdrawable in all positions
KMS 1 lock mechanism
Individual lock mechanism, not suitable for master key systems
T0-.../E, .../I1, .../Z
T3-.../E, .../I2, .../Z
P1-.../E, .../I2, .../Z
Key withdrawal
positions are
programmed ex-
works to match
the switch
+SVA-T3
Key withdrawal
positions can be
programmed by
the user
SVA-T3
1 off
050962
050974
KMS 2–101) lock mechanisms
+SVA-SOND-KMS...-T3
907739
SVA-SOND-KMS...-T3
907747
KMS 201–4001) lock mechanisms
Individual lock mechanisms, not suitable for master key systems
Key can be withdrawn in positions as specified
KMS 1 lock mechanism
T0-.../E, .../I1, .../Z
T3-.../E, .../I2, .../Z
P1-.../E, .../I2, .../Z
Key withdrawal
positions are
programmed ex-
works as ordered
+SVA(...)-T3
907737
Key withdrawal
positions are
programmed
ex-works as
ordered
SVA(...)-T3
907745
.
Switches with FS 908 are suitable as main switches:
T0-1-... to T0-4-.../I1, .../E
T3-1-... to T3-5-.../I2
E
D
F
T3-1-... to T3-6- .../E
P1-.../I2, .../E
C
G
H
K
0
B
R
30
330
KMS 2–101) lock mechanisms
+SVA(...)-SOND-KMS...-T3
907734
SVA(...)-SOND-KMS...-T3
907742
KMS 201–4001) lock mechanisms
300
270
240
60
90
120
315 45
225 135
Individual lock mechanisms, not suitable for master key systems
A
J
(SAE) = Individual lock mechanism
supplied with a security certificate
+SVA(...)-SOND-SAE-T3
907736
SVA(...)-SOND-SAE-T3
907744
210
150
(SA...) = Master key system (with master key) supplied with a security
certificate. Order must include a lock plan (FO276) showing the full
configuration of the envisaged lock system. For subsequent part orders,
simply state the item number within the lock plan, e.g. (X4711,
item 7).2)
+SVA(...)-SOND-(SA...)-T3
914735
SVA(...)-SOND-(SA...)-T3
914736
180
L
Q
P
M
N
Letter S for panic lock with FS908GE
Ordering example:
SVA(A-G)-SOND-(SAA 6294-1/2)
1)
Notes
KMS 1: can be supplied ex-stock; KMS 2 – 10, 201 – 400
and master key systems: delivery time < 6 weeks from order receipt at the factory
2)
For subsequent orders, the keys must be ordered separately a Page 07/061
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/060
T Rotary Switches, P Switch-Disconnectors
07/061
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Locking facility
Type suffix
Price
Locking facility
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Std. pack Notes
When ordered
with basic unit
When ordered separately
SVC-T3 padlocking feature, Front IP65
In the depressed position, the locking slide is lockable with up to 3 padlocks
All positions are lockable
T0-.../E, .../I1, .../Z
Lockable positions
are programmed
ex-works to match
the switch
+SVC-T3
Lockable
SVC-T3
1 off
1 off
SVC-T3 can be fitted to T0, T3 and P1 switches.
T3-.../E, .../I2, .../Z
P1-.../E, .../I2, .../Z
050963
positions can be
programmed by
the user
050975
Switching is carried out using the thumb-grip,
and interlocking by depressing an actuator which can be
locked in position using up to 3 padlocks. In standard
applications, all positions are lockable.
With type reference SVC(...)-T3, only the specified positions or
ranges are lockable. Where ranges are locked, switching is
possible only within a locked range, unless the padlock is
removed first.
The lockable positions or ranges for SVC(...)-T3 and the locked
position for DTV(...)-T3 are shown below. As with SVA(...)-T3,
use the code letters to state your selection on the order:
Example 1: SVC(A)-T3 = Only position A lockable
Example 2: SVC(A, E)-T3 = Positions A and E lockable
Example 3: SVC(A–J)-T3 = Range A to J lockable
Example 4: DTV(G)-T3 = The release mechanism must be
actuated to allow switching in this position.
Example 5: SVC(S)-T3 = Main switches, for use as Emergency-
Stop devices to IEC / EN 60 204-1; with red handle and yellow
front plate as panic lock version, lockable in positions A and E;
switching is still possible from E to A, but not from A to E.
When retrofitting the SVA-T3, use the front plate of the switch.
With letter S for panic lock, use FS908GE. Ordering example:
P1-25/I2-RT+SVC(S)-T3
Specified positions or ranges are lockable
Switches with FS908 may be used as main switches for
T0-1-... to T0-4-.../I1, .../E
T3-1-... to T3-5-.../I2
T3-1-... to T3-6-.../E
P1-.../I2, .../E
Lockable positions
are programmed
ex- works as
+SVC(...)-T3
907740
Lockable
SVC(...)-T3
907748
positions are
programmed ex-
works as ordered
ordered
DTV-T3 push-button interlock, Front IP65
Only after depressing the release button is it possible to switch from an unlocked position or range into
a locked position or range, but not the reverse (protection against tampering).
With a padlock in place when the release button is in the non-actuated position, it is not possible to
switch into the locked positions.
T0-.../E, .../I1, .../Z
T3-.../E, .../I2, .../Z
P1-.../E, .../I2, .../Z
Lockable using
2 padlocks
Lockable positions
are programmed
ex-works to match
the switch
+DTV-T3
050961
–
–
1 off
E
Specified positions locked
Release mechanism can be locked in the non-actuated
position with 1–2 padlocks
Lockable positions
are programmed
ex- works as
+DTV(...)-T3
907733
1 off
1 off
D
F
C
G
H
K
0
ordered
B
R
30
330
300
270
240
60
90
120
315 45
225 135
Locking cams (2 cams per set)
A
J
For user to select indexing
position in which key can
be withdrawn
S-T0 for all switching angles
–
–
VR-T0
089082
210
150
180
L
Q
P
M
N
For changing the locked positions/ranges
SVA-T3, SVC-T3, for all switching angles
for DTV-T3: order 2 x VR-T3
VR-T3
050987
1 off
Keys
For KMS 1 individual lock mechanism
S-T0, SVA-T3
S-T0, SVA-T3
S-T0, SVA-T3
–
–
–
SVS-KMS1
1 off
001871
For KMS 2 – 10 individual lock mechanism
or KMS 201 – 400
SVS-KM...
914714
For master key systems and
recorded individual lock mechanisms: state lock
plan no. and lock
SVS-SA(...)
901982
Master keys must always be ordered separately. Please send or
submit the security certificate with repeat orders.
For SA(...), the precise designation of the key must be stated
e.g. SVS-SA(A6294-1/2)
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/062
T Rotary Switches, P Switch-Disconnectors
07/063
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Type suffix
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Std. pack
When ordered
with basic unit
When ordered separately
Main switch assembly kits
Padlocking feature, exclusively for main switches, to permit them to be used as
Emergency-Stop devices1)
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z, .../I1
T3-.../E, .../Z, .../I2
P1-.../E, .../Z, .../I2
+SVB-T0
SVB-T0
1 off
1 off
For locking in the 0 (Off) position:
For switches with the positions 0 – I at 90° switching
angle, as front plate: FS908
026450
057892
T5(B)-.../E, .../Z, .../I4
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
+SVB-P3
026364
SVB-P3
052999
Padlocking feature, exclusively for main switches without Emergency-Stop function
Black handle, black locking collar
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z, .../I1
T3-.../E, .../Z, .../I2
P1-.../E, .../Z, .../I2
+SVB-SW-T0
SVB-SW-T0
1 off
1 off
For locking in the Off position
or in the On position if required.
Lockable using up to 3 padlocks
076917
060265
T5(B)-.../E, .../Z, .../I4
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
–
SVB-SW-P3
062491
Padlocks with KMS lock mechanism, Type 219/38
(KMS...): please enquire.
Main switch assembly kits, with PE terminal and N terminal
Padlocking feature, exclusively for main switches, to permit them to be used as
Emergency-Stop devices1)
T0-.../E, .../Z
T3-.../E, .../Z
–
–
–
–
V/EA/SVB-T0
1 off
For conversion of:
062638
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
• T.../E flush mounting switches (with front plate FS908)
into T.../EA/SVB... flush mounting main switches
• T.../Z rear mounting switches (with front plate FS908)
into T.../V/SVB interlocked rear mounting main
switches
T5(B)-.../E, .../Z
V/EA/SVB-T5
045065
V/EA/SVB-SW-T0
065011
Padlocking feature, exclusively for main switches without Emergency-Stop function
Black handle, black locking collar
Admissible for T0 up to 4 contact units and for T3... up to 6 contact units
T0-.../E, .../Z
T3-.../E, .../Z
T5(B)-.../E, .../Z
V/EA/SVB-SW-T5
045064
Thumb-grips
Black
Red
T0-.../E, .../EZ, .../IVS, .../Z, .../I1
T3-.../E, .../EZ, .../IVS, .../Z, .../I2
P1-.../E, .../EZ, .../IVS, .../Z, .../I2
–
KNB-T0
1 off
038909
T0-.../E, .../IVS, .../Z, .../I1
T3-.../E, .../IVS, .../Z, .../I2
P1-.../E, .../IVS, .../Z, .../I2
+KNB-RT-T0
003214
KNB-RT-T0
043655
When ordered separately:
Use red handle to IEC/EN 60 204 for Emergency-Stop
switches only, and order corresponding yellow front
plate FS908GE-T0
Black
Red
T5(B)-.../E, .../Z, .../I4
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
–
KNB-P3
1 off
041282
T5(B)-.../E, .../Z, .../I4
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
+KNB-RT-P3
003215
KNB-RT-P3
046028
When ordered separately:
Use red handle to IEC/EN 60 204 for Emergency-Stop
switches only, and order corresponding yellow front
plate FS908GE-P3
Maintenance keys
For interlocked main switches
T0-.../V, T3-.../V, P1-.../V
T5(B)-.../V, P3-.../V
–
–
KNK-T0
1 off
1 off
Special devices for electricians, to allow them to switch
interlocked main switches On and Off, when the panel
door is open for maintenance purposes
000650
KNK-P3
000649
(to IEC/EN 60 204 Part 1, Clause 5.1.1.1)
1)
Notes
To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0
(Off) position
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/064
T Rotary Switches, P Switch-Disconnectors
07/065
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Type suffix
Price
Type
Price
Article no.
See Price
List
Std. pack
Article no.
See Price
List
Std. pack
When ordered
with basic unit
When ordered separately
Neutral poles
Early-make, late-break
Can be fitted to left and/or right of 3-pole P switch-disconnectors
P1-.../E, .../EA, .../EZ
–
N-P1E
5 off
The neutral contact is always early-make and late-break.
000651
Switching capacity of N-P1... equivalent to P1-32...
contacts
with P1-.../I2:
optional N-P1Z or HI11-P1/P3Z
can only be fitted to left
P1-.../Z, .../V, .../I2, .../ST, .../IVS
P3-.../E, .../EA...
+N-P1Z
000416
1 off
1 off
N-P1Z
000652
–
N-P3E
062432
The neutral contact is always early-make and late-break.
Switching capacity of N-P3... equivalent to P3-100...
contacts
P3-.../Z, .../V, .../IVS
P3-63/E, .../Z, .../I4, .../ST
P3-100/E, .../Z, .../I5, .../ST
+N-P3Z
009036
N-P3Z
064805
Auxiliary contacts
1 make contact, 1 break contact
Can be fitted to left and/or right of 3-pole P switch-disconnectors
P1-.../E, .../EA..., .../EZ
P3-.../E, .../EA
+HI11-P1/P3E
1 off
1 off
HI11-P1/P3E
5 off
5 off
The make contact is always connected as a load-shedding
contact, i.e. late-make, early-break.
064100
061813
With P1-.../I2:
HI11-P1/P3Z or
N-P1Z can be fitted to left only
P1-.../Z, .../V, .../I2, .../ST, .../IVS
P3-63/Z, .../V, .../I4, .../ST, .../IVS 064526
P3-100/Z, .../V, .../I5, .../ST, .../IVS
+HI11-P1/P3Z
HI11-P1/P3Z
062031
Centre mounting accessories
For single-hole fitting
Mounting diameter 22.3 mm
With front plate
T0-.../E, T3-.../E
T0-.../E, T3-.../E
+EZ-T0
1 off
1 off
EZ-T0
1 off
1 off
Rapid snap-fitting in panel sides, plates and doors.
Legend plates from the RMQ range of control circuit
devices can be used.
001750
081622
Without front plate
For engraved front plates
+EZ/OFS-T0
001751
EZ/OFS-T0
001869
Mounting diameter 22.3 mm and 30.5 mm
T0-.../E, T3-.../E, P1-.../E
+EZ-P1
026222
1 off
EZ-P1
091455
5 off
Screw fixing enables one person to fit the equipment into
panel sides, plates and doors.
Legend plates from the RMQ range of control circuit
devices can be used.
Service distribution board mounting accessories
Includes push-fit shaft
T0-.../XZ
+IVS-T0
045472
1 off
IVS-T0
091114
1 off
Use the front plate of the basic switch
For retrofitting T0-.../XZ basic switches as T0-.../IVS into service distribution
boards
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/066
T Rotary Switches, P Switch-Disconnectors
07/067
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Type suffix
Price
Type
Price
Article no.
See Price
List
Std. pack
Article no.
See Price
List
Std. pack
When ordered
with basic unit
When ordered separately
Coupling drive
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ basic switches
–
–
DE-T0
1 off
3 off
in the rear mounting form Spare parts for T0(T3)/(P1)-.../Z
093487
For conversion of T5 (B)-.../E flush mounting switch
into a rear mounting switch
Spare parts for T5(B)/(P3)-.../Z
DE-P3
093972
Interlock sections
With PE and N conductor connection
T0-.../E, .../EZ
T3-.../E, .../EZ
P1-.../E, .../EZ
+UV-T0
038519
1 off
UV-T0
019925
1 off
Fits on the reverse of flush mounting switches
T5(B)-.../E
P3-.../E
+UV-P3
1 off
1 off
UV-P3
1 off
1 off
030402
048289
For cover or door interlock
With PE and N conductor connection
T0-.../Z
T3-.../Z
P1-.../Z
+UV-T0
038519
UV-T0
019925
With interlocking function for rear mounting switches
T5(B)-.../Z
P3-.../Z
+UV-P3
030402
1 off
UV-P3
048289
1 off
Interlock extensions1)
Up to four off, 25 mm each, can be plugged onto interlock section
(An equal number of shaft extensions is required for this purpose)
UV-T0
UV-P3
+ZVV-T0
1 off
1 off
ZVV-T0
10 off
10 off
Notes relating to installation in enclosures
a Page 07/089
024662
022298
+ZVV-P3
024379
ZVV-P3
024671
Shaft extensions
Up to four off, 25 mm each,
can be plugged onto switch shaft
T0-.../Z
T3-.../Z
P1-.../Z
+ZAV-T0
1 off
1 off
ZAV-T0
10 off
10 off
Notes relating to installation in enclosures
a Page 07/089
023736
027044
T5(B)-.../Z
P3-.../Z
+ZAV-P3
026623
ZAV-P3
029417
1)
Notes
Use ZVV-T0 only with T0/T3-.../Z and P1-.../Z
Use ZVV-P3 only with T5(B)-.../Z and P3-.../Z
Moeller HPL0211-2001/2002
Moeller HPL0211-2001/2002
07/068
T Rotary Switches, P Switch-Disconnectors
07/069
T Rotary Switches, P Switch-Disconnectors
Accessories
Accessories
For use with
Type suffix
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Std. pack
1 off
When ordered
with basic unit
When ordered separately
Sleeves/covers
For flush-mounting switches with up to 4 contact units
T0-.../E
T3-.../E
P1-.../E
–
H3-T0
093828
Cable entries
Quantity:
2 x o 20 mm
+ 2 x o 15 mm
Cross-section:
5 x 6 mm2
5 x 2.5 mm2
Cover for protection of terminals
For up to 2 contact units
T5(B)-.../E, .../Z
H1-T5
–
–
H1-T5
1 off
Can be used for input and/or output wiring
1x HZ-T5 required per contact unit
045062
Extension of H1-T5 cover
To protect 3 to 8 contact units
HZ-T5
045063
10 off
To cover terminals on
3-pole switch-disconnectors
P1-.../E, .../EZ, .../Z, .../EA, .../V
P1-...N, ...HI11, ...N...HI11
–
–
H-P1
5 off
5 off
Can be used for input and/or output wiring
017253
H-P14
019626
To cover terminals on
3-pole open switch-disconnectors with N neutral conductor
and/or HI11 auxiliary contact modules fitted
P3-.../E, .../Z, .../EA, .../V
P3-...N, ...HI11, ...N...HI11
–
H-P3
021999
5 off
The shroud is designed for fitting onto both sides of the
switch-disconnector. Parts which are not required can
be broken off.
Cover assembly to protect the 6 terminals
Cover assembly to protect the 6 terminals
T6-160-6/...
–
–
H-T6-160
1 off
200183
T8-3-8342/...
H-T8
200184
1 off
Moeller HPL0211-2001/2002
07/070
T Rotary Switches, P Switch-Disconnectors
Accessories
For use with
Type
Price
Article no.
See Price
List
Std. pack
Insulated enclosures, IP65
Enclosures designed for metric cable glands to EN 50 262
1 – 2 contact units
3 – 4 contact units
1 – 2 contact units
3 – 4 contact units
5 contact units
T0-.../XZ
T0-.../XZ
T3-.../XZ
T3-.../XZ
T3-.../Z
CI-K1-T0-2
1 off
Cable sizes which may be pushed through the
207435
diaphragm
CI-K1-T0-4
207436
Type
Main-/control current
CI-K2-T3-2
207437
Cl-K1-T0-...
Cl-K2-T3-...
12 mm
16 mm
–
8 mm
CI-K2-T3-4
225325
CI-K2-T3-5
207438
1 – 2 contact units
3 – 4 contact units
T5B-.../E
T5B-.../Z
CI-K4-T5B-2
207439
CI-K4-T5B-4
207440
1 – 2 contact units
3 – 4 contact units
T5-.../Z
T5-.../Z
CI-K5-T5-2
Converts T5-.../Z into T5-.../I5 and
T5B-.../E into T5B.../I4:
207441
Order AW-T5-... extension terminals in addition
CI-K5-T5-4
207442
a Page 07/071
Neutral terminals
T0-.../I1, Cl-K1-T0-...
T3-.../I2, Cl-K2-T3-...
P1-.../I2
K-CI-K1/2
20 off
20 off
1 off
For connection of 5th conductor
207451
T5B-.../I4,
Cl-K4-T5B-...
P3-.../I4
K-CI-K4
206916
T5-.../I5,
Cl-K5-T5-...
P3-.../I5
K-CI-K5
218488
Set of external fixing brackets
T5B-.../I4, T5-.../I5,
P3-63/I4, P3-100/I5,
AB-CI-K4/5
206914
1 off
For fixing CI-K4 and CI-K5 directly to the wall
One set comprises 4 brackets
Metric diaphragm grommets
External cable Cable entry
diameter
mm
Hole diameter
mm
• IP65
• With integral push-through diaphragm
H03VV-F 3 x 0.75 mm²,
KT-M20
100 off
1 – 13
1 – 18
1 – 24
M20
M25
M32
20.5
25.5
32.5
NYM 5 x 1.5/5 x 2.5 mm²
207602
H03VV-F 3 x 0.75 mm²,
NYM 4 x 10 mm²
KT-M25
207603
H03VV-F 3 x 0.75 mm²,
KT-M32
207604
NYM 4 x 16/5 x 10 mm²
Metric cable glands to EN 50 262
• With lock nut and integral cable clamp
• IP68 up to 5 bar, halogen free
H05VV-F 4 x 2.5/3 x 4 mm², V-M20
20 off
20 off
10 off
10 off
5 off
6 – 13
M20
M25
M32
M32
M50
20.5
25.5
32.5
32.5
50.5
NYM 5 x 1.5/5 x 2,5 mm²
206910
H05VV-F 5 x 2.5/5 x 4 mm², V-M25
9 – 17
NYM 5 x 2.5/5 x 6 mm²
NYM 5 x 10 mm²
206911
V-M32
206912
13 – 21
18 – 25
18 – 35
NYM 5 x 16 mm²
V-M32G
226156
NYM 4 x 35/5 x 25 mm²
V-M50
206913
Moeller HPL0211-2001/2002
07/071
T Rotary Switches, P Switch-Disconnectors
Accessories
For use with
Type
Price
Article no.
See Price
List
Std. pack
Set of extension terminals
For cable connection in the enclosure
For the lowest contact unit
T5B-.../I4
T5-.../I5
AW-T5-1/2
1 off
1 off
Included with T5B-.../I4
and T5-.../I5 as standard
Fit T5(B) with extension terminals to install it
as T5(B)-.../E in an insulated enclosure.
032601
For the second contact unit from the bottom
T5-.../I5
AW-T5-3/4
032602
Indicator lights, conical, BA9s
For fitting in M20/M25 pre-mouldings in the enclosure base
For filament bulbs and neon bulbs up to 2.4 W a Page 02/040
Colour: red
P1-.../I2, P3-.../I..., L-R
5 off
T...-.../I...
208689
Colour: white
Colour: green
Colour: yellow
L-W
208692
L-G
208690
L-Y
208691
Set of adapter rings
To allow PG cable glands to be used in metric cable entries
M25-PG16
1 set
1 set = 50 off
1 set = 25 off
1 set = 10 off
1 set = 10 off
218923
M32-PG21
218924
M40-PG29
218925
M50-PG36
218926
Moeller HPL0211-2001/2002
07/072
TM Mini Rotary Switches
System Overview
TM On-Off switches
1
2
10
9
9
8
7
8
5
8
6
8
8
6
4
6
3
4
4
8
TM control switches
1
10
2
9
11
9
5
O
HAND
AU
T
O
6
6
4
6
3
4
4
Moeller HPL0211-2001/2002
07/073
TM Mini Rotary Switches
System Overview
Flush mounting (.../E)
1
Centre mounting (.../EZ)
2
Centre mounting switches, standard
5, 6
Front IP65
Front IP65
Black thumb-grip and silver-coloured
front plate
Fitting from rear in panel sides, plates
or doors
Mounting in a standard 16.2 mm aperture,
or in 22.3 mm to IEC/EN 60 947-5-1
following removal of supplied adapter
Terminal:
Pozidriv screw
a Page 07/074
M22-ST... legend plate mounts from the
RMQ control circuit range can be used for
marking
Finger-proof
(see Page 02/027)
Control circuit isolators
7, 8
a Page 07/074
Red rotary handle and yellow locking
collar
a Page 07/074
Black rotary handle and black locking
collar
Flush mounting
1
control circuit isolators (.../E/SVB)
Lockable in the 0 (Off) position
Key operation for centre mounting
3, 4
Front IP65
To IEC/EN 60 947-5
2 keys are supplied
a Page 07/074
Option for key withdrawal at 90° with
KABA micro cylinder lock
Lockable in 0 (Off) position using two
padlocks, 4 mm ∅ or 1 padlock, 6 mm ∅
Can be used at up to 250 V AC per contact
Up to 6 contacts admissible
Option for key withdrawal at 60° with
RONIS cylinder lock
Flush mounting switches, standard
9, 10
Always state the position in which the key
is to be withdrawable
Black thumb-grip and silver-coloured
front plate
a Page 07/074
a Page 07/083
a Page 07/074
Standard switches for distribution
board mounting (.../IVS)
11
Mounting in service distribution boards
Mounting width: 2 space units
(45 mm mounting depth)
Up to 2 contact units
a Page 07/074
Product attributes
Switch position
Contact chamber
Circuit diagrams (examples)
• Reliable switching due to indexing
mechanism
• Rated uninterrupted current 10 A
• Gold-plated contacts for safe switching
of extra low voltages and currents
even in corrosive atmospheres
1
2
3
4
• Switching angles 30°, 45°, 60°, 90°
• Automatic return with up to
6 contacts
Terminal marking
Link
• Positively opening contacts
• 1 – 2 contacts per contact chamber,
up to 16 contacts per switch
• Complete rotation
• Switching angle of 360°
allows complete rotation in both
directions
0
1
2
Contact open
• Switching of differing potentials
• Control circuit reliability
Contact closed
Switch position
Switch position 1:
Contact 1 – 2 open,
Contact 3 – 4 closed.
1
2
3
4
Switching from 1 to 2:
Contact 1 – 2 early-make,
Contact 3 – 4 late-break.
Switching from 2 to 3:
0
1
2
Contact 1 – 2 opens briefly.
Switching from 3 to 4:
Contact 1 – 2 remains closed.
3
4
Moeller HPL0211-2001/2002
07/074
TM Mini Rotary Switches
Control Circuit Isolators, On-Off Switches
Circuit diagram
Front plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Service distribution board
mounting
Front IP30
Type
Price
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
Control circuit isolators, 90°
With padlocking facility, lockable in the Off position
Up to 250 V AC per contact
1
1
TM-1-8290/E/SVB
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
045477
2
0
1
TM-1-8290/E/SVB-SW
215351
1
3
4
2
TM-1-8291/E/SVB
045478
2
0
1
TM-1-8291/E/SVB-SW
215352
1
3
5
6
3
TM-2-8292/E/SVB
045484
2
4
0
1
TM-2-8292/E/SVB-SW
210955
1
2
3
4
5
6
7
8
3+N
6
TM-2-8293/E/SVB
045485
0
1
TM-2-8293/E/SVB-SW
215353
1
3
5
7
9
11
TM-3-8326/E/SVB
045498
2
4
6
8
10 12
0
1
TM-3-8326/E/SVB-SW
215354
On-Off switches, 90°
1
1
TM-1-8290/E
070131
TM-1-8290/EZ
000693
TM-1-8290/IVS
225334
1
0
2
0
1
F 056
1
2
3
4
1
2
TM-1-8291/E
072504
TM-1-8291/EZ
015073
TM-1-8291/IVS
225335
0
0
1
F 056
1
2
3
4
5
6
1
3
TM-2-8292/E
074877
TM-2-8292/EZ
015096
TM-2-8292/IVS
225336
0
0
1
F 056
1
2
3
4
5
6
7
8
1
3+N
6
TM-2-8293/E
TM-2-8293/EZ
TM-2-8293/IVS
0
077250
045486
225337
0
1
F 056
1
2
3
4
5
6
7
8
9
11
1
TM-3-8326/E
079623
TM-3-8326/EZ
045499
–
0
10 12
0
1
F 056
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/075
TM Mini Rotary Switches
Control Switches: Changeover Switches
Circuit diagram
Front plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Service distribution board
mounting
Front IP30
Type
Price
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
Changeover switches without 0 (Off) position, 60°
1
3
1
2
3
4
5
TM-1-8220/E
TM-1-8220/EZ
TM-1-8220/IVS
1
2
2
2
2
081996
000692
225338
2
4
1
2
F 072
1
3
5
6
7
8
TM-2-8221/E
084369
TM-2-8221/EZ
015197
TM-2-8221/IVS
225339
1
2
4
1
2
F 072
1
2
3
4
5
6
7
8
9
11
TM-3-8222/E
086742
TM-3-8222/EZ
045493
–
–
–
–
1
10 12
1
2
F 072
1
3
5
7
9
11 13 15
TM-4-8223/E
089115
TM-4-8223/EZ
046119
1
2
4
6
8
10 12 14 16
1
2
F 072
1
2
3
4
5
6
7
8
9
11 13 15 17 19
TM-5-8369/E
091488
TM-5-8369/EZ
046126
1
2
2
10 12 14 16 18 20
1
2
F 072
6
TM-6-8370/E
093861
TM-6-8370/EZ
046130
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
1
10 12 14 16 18 20 22 24
1
2
F 072
Changeover switches with 0 (Off) position, 60°
1
3
1
2
3
4
TM-1-8210/E
TM-1-8210/EZ
TM-1-8210/IVS
0
1
2
096234
015137
225340
2
4
1
0
2
F 071
1
2
3
4
5
6
7
8
TM-2-8211/E
098607
TM-2-8211/EZ
015166
TM-2-8211/IVS
225341
0
1
2
1
0
2
F 071
1
2
3
4
5
6
7
8
9
11
0
2
TM-3-8212/E
010807
TM-3-8212/EZ
045491
–
–
1
10 12
2
0
1
F 249
1
2
3
4
5
6
7
8
9
11 13 15
0
2
TM-4-8213/E
013180
TM-4-8213/EZ
045847
1
10 12 14 16
2
0
1
F 249
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/076
TM Mini Rotary Switches
Control Switches: Changeover Switches, Hand/Auto Switches
Circuit diagram
Front plate
no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Service distribution board
mounting
Front IP30
Type
Price
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
Changeover switches with 0 (Off) position, 90°
1
3
0
1
2
TM-1-8218/E
TM-1-8218/EZ
–
–
1
2
015553
045476
2
4
1
0
2
F 057
1
2
3
4
5
6
7
8
0
TM-2-8219/E
017926
TM-2-8219/EZ
045482
1
2
1
0
2
F 057
1
3
5
7
9
11
0
3
TM-3-8299/E
TM-3-8299/EZ
–
–
1
2
2
020299
045497
2
4
6
8
10 12
1
0
2
F 057
1
3
4
5
6
7
8
9
11 13 15
0
3+N
TM-4-8294/E
022672
TM-4-8294/EZ
046121
1
2
10 12 14 16
1
0
2
F 057
Hand/Auto switches, 60°
1
3
HAND AUTOM
1
1
–
TM-1-8220 F288/EZ
–
2
4
016925
HAND
AUTO
F 288
0
1
3
TM-1-15431/E
025045
TM-1-15431/EZ
000691
TM-1-15431/IVS
225342
HAND AUTO
2
4
HAND
0
AUTO
F 085
0
1
2
3
4
5
6
7
8
2
3
TM-2-15432/E
TM-2-15432/EZ
TM-2-15432/IVS
HAND AUTO
027418
016878
225343
HAND
0
AUTO
F 085
0
1
2
3
4
5
6
7
8
9
11
TM-3-15433/E
029791
TM-3-15433/EZ
045490
–
HAND AUTO
10 12
HAND
0
AUTO
F 085
Changeover switches with spring-return from both
directions, 30°
1
3
1
2
3
TM-1-8214/E
TM-1-8214/EZ
–
–
–
0
1
2
2
2
032164
016673
2
4
1
0
2
F 025
1
2
3
4
5
6
7
8
TM-2-8215/E
034537
TM-2-8215/EZ
045481
0
1
1
0
2
F 025
1
3
5
7
9
11
TM-3-8216/E
036910
TM-3-8216/EZ
045492
0
1
2
4
6
8
10 12
1
0
2
F 025
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/077
TM Mini Rotary Switches
Control Switches: Step Switches
Circuit diagram
Front
plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Service distribution board
mounting
Front IP30
Type
Price
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Article no.
See Price
List
Step switches without 0 (Off) position, 60°
3 steps
1
3
5
1
3
TM-2-8230/E
TM-2-8230/EZ
TM-2-8230/IVS
225344
2
3
039283
000701
1
2
4
6
1
2
3
F 076
1
3
5
7
8
9
11 13 15 17
TM-5-8270/E
041656
TM-5-8270/EZ
046124
2
1
3
2
4
6
10 12 14 16 18
1
2
3
F 076
4 steps
1
3
5
7
1
3
TM-2-8231/E
TM-2-8231/EZ
TM-2-8231/IVS
225345
2
3
044029
000700
1
4
2
4
6
8
1
2
3
4
F 077
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
TM-6-8271/E
046402
TM-6-8271/EZ
046128
2
1
3
4
10 12 14 16 18 20 22 24
1
2
3
4
F 077
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/078
TM Mini Rotary Switches
Control Switches: Step Switches
Circuit diagram
Front plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Step switches without 0 (Off) position
5 steps, 60°
1
3
5
7
9
1
2
TM-3-8232/E
TM-3-8232/EZ
2
3
5
039298
015592
1
4
2
4
6
8
10
1
2
3
4
5
F 078
1
2
3
4
5
6
7
8
9
11 13 15 17 19
TM-5-8252/E
041671
TM-5-8252/EZ
046123
2
1
3
5
4
10 12 14 16 18 20
1
2
3
4
5
F 078
6 steps, 60°
Without complete rotation
1
3
5
7
9
11
1
2
TM-3-8233/E
TM-3-8233/EZ
2
1
3
5
053521
015630
4
2
4
6
8
10 12
6
1
2
3
4
5
6
F 079
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
TM-6-8253/E
055894
TM-6-8253/EZ
046127
2
1
3
5
4
10 12 14 16 18 20 22 24
6
1
F 079
2
3
4
5
6
10 steps, 30°
1
3
5
7
9
11 13 15 17 19
1
TM-5-8237/E
069150
TM-5-8237/EZ
015661
4
3
5
2
6
1
7
8
2
4
6
8
10 12 14 16 18 20
9
10
1
2
3
4
5
6
7
8
9
F 011
10
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/079
TM Mini Rotary Switches
Control Switches: Step Switches
Circuit diagram
Front plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Step switches with additional 0 (Off) position
2 steps, 60°
1
3
1
2
3
TM-1-8240/E
TM-1-8240/EZ
1
2
2
2
0
058267
015226
2
4
0
1
2
F 075
1
3
5
6
7
8
TM-2-8260/E
060640
TM-2-8260/EZ
045483
1
0
2
4
0
1
2
F 075
TM-3-8280/E
063013
TM-3-8280/EZ
045496
1
2
3
4
5
6
7
8
9
11
1
0
10 12
0
1
2
F 075
3 steps, 45°
2
1
1
3
5
1
2
3
TM-2-8241/E
TM-2-8241/EZ
3
3
3
0
065386
015256
2
4
6
0
1
2
3
F 109
1
2
3
4
5
6
7
8
9
11
2
1
TM-3-8261/E
067759
TM-3-8261/EZ
000698
0
10 12
0
1
2
3
F 109
1
2
3
4
5
6
7
8
9
11 13 15 17
2
1
TM-5-8281/E
070132
TM-5-8281/EZ
046125
0
10 12 14 16 18
0
F 109
1
2
3
4 steps, 30°
1
3
5
7
3
2
1
2
3
TM-2-8242/E
TM-2-8242/EZ
4
1
0
072505
015506
2
4
6
8
0
1
2
3
4
F 002
1
2
3
4
5
6
7
8
9
11 13 15
3
2
TM-4-8262/E
074878
TM-4-8262/EZ
046120
4
1
0
10 12 14 16
0
F 002
1
2
3
4
3
2
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23
TM-6-8282/E
077251
TM-6-8282/EZ
046129
4
1
0
10 12 14 16 18 20 22 24
0
F 002
1
2
3
4
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/080
TM Mini Rotary Switches
Control Switches: Step Switches, Group Switches
Circuit diagram
Front plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Step switches with additional 0 (Off) position, 30°
5 steps
1
3
5
6
7
8
9
1
1
TM-3-8243/E
TM-3-8243/EZ
3
2
4
5
1
079624
015537
0
2
4
10
0
1
2
3
4
5
F 003
6 steps
1
3
5
6
7
8
9
11
TM-3-8244/E
081997
TM-3-8244/EZ
045495
3
2
4
5
6
1
0
2
4
10 12
0
1
2
3
4
5
6
F 004
9 steps
1
3
5
7
9
11 13 15 17
1
TM-5-8247/E
009741
TM-5-8247/EZ
015565
3
2
4
8
1
0
5
6
2
4
6
8
10 12 14 16 18
7
9
0
1
2
3
4
5
6
7
8
9
F 007
Group switches
2 groups, 60°
1
3
1
1
TM-1-8310/E
TM-1-8310/EZ
1
0
2
084370
045479
2
4
0
1
2
F 075
3 groups, 30°
1
3
5
TM-2-8311/E
086743
TM-2-8311/EZ
045487
3
2
1
0
2
4
6
0
1
2
3
F 001
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/081
TM Mini Rotary Switches
Control Switches: On/Off Switches, Spring-Return
Circuit diagram
Front plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
On/Off switches with spring-return, 30°
Off switches, spring-return
1
STOP
F 022
START
1
1
TM-1-8174/E
TM-1-8174/EZ
089116
016646
2
STOP
On switches, spring-return
1
TM-1-8175/E
091489
TM-1-8175/EZ
015690
2
F 023
START
On-Off switches, spring-return
1
3
STOP START
1
2
TM-1-8176/E
TM-1-8176/EZ
093862
016714
2
4
STOP
F 024
START
1
2
3
4
5
6
7
8
STOP START
TM-2-8183/E
096235
TM-2-8183/EZ
045480
STOP
F 024
START
On-Off spring-return switches, 90°/30°
With spring-return from START to 1
1
2
3
4
1START
1
TM-1-8178/E
098608
TM-1-8178/EZ
016786
0
F 119
START
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/082
TM Mini Rotary Switches
Control Switches: Reversing Switches, Coding Switches
Circuit diagram
Front plate no.
No. of
poles
Flush mounting
Front IP65
Centre mounting
Front IP65
Type
Price
Type
Price
Article no.
See Price
List
Article no.
See Price
List
Reversing switches
With spring-return from Start to 1 or 2, 60°/30°
0
1
TM-2-8177/E
010808
TM-2-8177/EZ
016838
1
3
5
7
1
2
START START
2
4
6
8
F 121
START
1
0
2
START
Reversing switches, 60°
2
3
TM-2-8400/E
TM-2-8400/EZ
0
1
2
1
2
3
4
5
6
7
8
013181
045488
1
0
2
F 071
TM-3-8401/E
015554
TM-3-8401/EZ
045500
0
1
1
3
5
7
9
2
2
4
6
8
10
1
0
2
F 071
Reversing switches with spring-return to 0, 30°
3
1
TM-3-8228/E
TM-3-8228/EZ
0
1
2
1
2
3
4
5
6
7
8
9
017927
045494
10
1
0
2
F 025
Coding switches, BCD Code 0 – 9, 30°
1
2
3
4
5
6
7
8
TM-2-8550/E
020300
TM-2-8550/EZ
000699
3
2
4
8
1
0
5
6
7
9
0
1
2
3
4
5
6
7
8
9
F 007
Complementary BCD code 0 – 9, 30°
1
3
5
7
1
1
TM-2-8551/E
TM-2-8551/EZ
3
2
4
8
1
0
5
022673
045489
6
2
4
6
8
7
9
0
1
2
3
4
5
6
7
8
9
F 007
BCD code 0 – 9 + complement, 30°
1
3
5
7
9
11 13 15
TM-4-8552/E
025046
TM-4-8552/EZ
046122
3
2
4
8
1
0
5
6
2
4
6
8
10 12 14 16
7
9
0
1
2
3
4
5
6
7
8
9
F 007
Standard pack: 1 off
Moeller HPL0211-2001/2002
07/083
TM Mini Rotary Switches
Accessories
Type
Price
Article no.
See Price
List
Key operation1)
Includes two keys
KABA lock for 90° switching angle1)
The key can be withdrawn only in specified positions, see
Degree of protection IP65
diagrams below. However, the KABA lock mechanism for
90° can also be used for other switching angles provided
the positions for key withdrawal correspond with those
specified for the Type of switch.
Key withdrawable at:
0°
+EZ/S-A
045458
270°
+EZ/S-B
045459
Example: +EZ/S-B can be used on a step switch having a
switching angle of 30°, provided the key is to be with-
drawn only in the Off position at 270°.
The key is not withdrawable in positions which exceed the
total switching angle of the switch.
270 + 0°
+EZ/S-F
045463
0 + 90°
+EZ/S-E
045462
Options for key withdrawal
270 + 0 + 90°
270 + 0 + 90 + 180°
+EZ/S-R
045471
+EZ/S-G
045464
A
C
B
F
E
J
R
G
N
RONIS lock for 60° switching angle1)
Degree of protection IP55
Q
D
H
M
P
Key withdrawable at:
0 + 180°
+EZ/S-C
045460
270 + 90°
+EZ/S-D
045461
300 + 0 + 60 + 120 + 180 + 240°
270 + 330 + 30 + 90 + 150 + 210°
0 + 60 + 180 + 240°
270 + 330 + 90 + 150°
300 + 0 + 120 + 180°
270 + 30 + 90 + 210°
+EZ/S-H
045465
For example of position marking see a Page 07/111
+EZ/S-J
045466
+EZ/S-M
045467
0
330
30
300
270
240
60
90
315
45
+EZ/S-N
045468
225 135
120
210
150
+EZ/S-P
045469
180
+EZ/S-Q
045470
1)
Standard pack: 1 off
For mounting forms E and EZ
Moeller HPL0211-2001/2002
07/084
T Rotary Switches
T0 Non-Standard Switches
Type
Price
Type
Price
Price
See Price
List
See Price
List
See Price
List
Std. pack
1 off
T0 rotary switches
T0-1-SOND.../E
T0-5-SOND.../E
T0-1-SOND.../EA/SVB
T0-1-SOND.../EA/SVB-SW
T0-1-SOND.../EZ
T0-5-SOND.../EZ
T0-5-SOND.../EZ/OFS
T0-5-SOND.../IVS
T0-5-SOND.../XZ
T0-5-SOND.../Z
T0-1-SOND.../EZ/OFS
T0-1-SOND.../I1
T0-1-SOND.../I1/SVB
T0-1-SOND.../I1/SVB-SW
T0-1-SOND.../IVS
T0-6-SOND.../E
T0-6-SOND.../EZ
T0-6-SOND.../EZ/OFS
T0-6-SOND.../IVS
T0-6-SOND.../XZ
T0-6-SOND.../Z
T0-1-SOND.../V/SVB
T0-1-SOND.../V/SVB-SW
T0-1-SOND.../XZ
T0-1-SOND.../Z
T0-2-SOND.../E
T0-7-SOND.../E
T0-2-SOND.../EA/SVB
T0-2-SOND.../EA/SVB-SW
T0-2-SOND.../EZ
T0-7-SOND.../EZ
T0-7-SOND.../EZ/OFS
T0-7-SOND.../IVS
T0-7-SOND.../XZ
T0-7-SOND.../Z
T0-2-SOND.../EZ/OFS
T0-2-SOND.../I1
T0-2-SOND.../I1/SVB
T0-2-SOND.../I1/SVB-SW
T0-2-SOND.../IVS
T0-8-SOND.../E
T0-8-SOND.../EZ
T0-8-SOND.../EZ/OFS
T0-8-SOND.../IVS
T0-8-SOND.../XZ
T0-8-SOND.../Z
T0-2-SOND.../V/SVB
T0-2-SOND.../V/SVB-SW
T0-2-SOND.../XZ
T0-2-SOND.../Z
T0-3-SOND.../E
T0-9-SOND.../E
T0-3-SOND.../EA/SVB
T0-3-SOND.../EA/SVB-SW
T0-3-SOND.../EZ
T0-9-SOND.../EZ
T0-9-SOND.../EZ/OFS
T0-9-SOND.../IVS
T0-9-SOND.../XZ
T0-9-SOND.../Z
T0-3-SOND.../EZ/OFS
T0-3-SOND.../I1
T0-3-SOND.../I1/SVB
T0-3-SOND.../I1/SVB-SW
T0-3-SOND.../IVS
T0-10-SOND.../E
T0-10-SOND.../EZ
T0-10-SOND.../EZ/OFS
T0-10-SOND.../IVS
T0-10-SOND.../XZ
T0-10-SOND.../Z
T0-3-SOND.../V/SVB
T0-3-SOND.../V/SVB-SW
T0-3-SOND.../XZ
T0-3-SOND.../Z
T0-4-SOND.../E
T0-11-SOND.../E
T0-4-SOND.../EA/SVB
T0-4-SOND.../EA/SVB-SW
T0-4-SOND.../EZ
T0-11-SOND.../EZ
T0-11-SOND.../EZ/OFS
T0-11-SOND.../IVS
T0-11-SOND.../XZ
T0-11-SOND.../Z
T0-4-SOND.../EZ/OFS
T0-4-SOND.../I1
T0-4-SOND.../I1/SVB
T0-4-SOND.../I1/SVB-SW
T0-4-SOND.../IVS
T0-4-SOND.../V/SVB
T0-4-SOND.../V/SVB-SW
T0-4-SOND.../XZ
T0-4-SOND.../Z
Notes
These Pages show T rotary switches with non-
For subsequent orders, state contact sequence
The contact numbers for
standard contact sequences (-SOND...) which are number together with country identifer
non-standard contact sequences are:
>200 <8000 or >9000 <15000 or
>16000.
priced accordingly (See Price List). Use the Initial
Order form on a Page 07/112 for ordering any
T rotary switch combination.
(eg 4711GB)
Moeller HPL0211-2001/2002
07/085
T Rotary Switches
T3 Non-Standard Switches
Type
Price
Type
Price
See Price
List
See Price
List
Std. pack
T3 rotary switches
T3-1-SOND.../E
T3-5-SOND.../E
1 off
T3-1-SOND.../EA/SVB
T3-1-SOND.../EA/SVB-SW
T3-1-SOND.../EZ
T3-5-SOND.../EA/SVB
T3-5-SOND.../EA/SVB-SW
T3-5-SOND.../EZ
T3-1-SOND.../EZ/OFS
T3-1-SOND.../I2
T3-5-SOND.../EZ/OFS
T3-5-SOND.../I2
T3-1-SOND.../I2/SVB
T3-1-SOND.../I2/SVB-SW
T3-1-SOND.../V/SVB
T3-1-SOND.../V/SVB-SW
T3-1-SOND.../XZ
T3-5-SOND.../I2/SVB
T3-5-SOND.../I2/SVB-SW
T3-5-SOND.../V/SVB
T3-5-SOND.../V/SVB-SW
T3-5-SOND.../XZ
T3-1-SOND.../Z
T3-5-SOND.../Z
T3-2-SOND.../E
T3-6-SOND.../E
T3-2-SOND.../EA/SVB
T3-2-SOND.../EA/SVB-SW
T3-2-SOND.../EZ
T3-6-SOND.../EA/SVB
T3-6-SOND.../EA/SVB-SW
T3-6-SOND.../EZ
T3-2-SOND.../EZ/OFS
T3-2-SOND.../I2
T3-6-SOND.../EZ/OFS
T3-6-SOND.../V/SVB
T3-6-SOND.../V/SVB-SW
T3-6-SOND.../XZ
T3-2-SOND.../I2/SVB
T3-2-SOND.../I2/SVB-SW
T3-2-SOND.../V/SVB
T3-2-SOND.../V/SVB-SW
T3-2-SOND.../XZ
T3-6-SOND.../Z
T3-7-SOND.../E
T3-2-SOND.../Z
T3-7-SOND.../EZ
T3-7-SOND.../EZ/OFS
T3-7-SOND.../XZ
T3-7-SOND.../Z
T3-3-SOND.../E
T3-3-SOND.../EA/SVB
T3-3-SOND.../EA/SVB-SW
T3-3-SOND.../EZ
T3-8-SOND.../E
T3-3-SOND.../EZ/OFS
T3-3-SOND.../I2
T3-8-SOND.../EZ
T3-8-SOND.../EZ/OFS
T3-8-SOND.../XZ
T3-8-SOND.../Z
T3-3-SOND.../I2/SVB
T3-3-SOND.../I2/SVB-SW
T3-3-SOND.../V/SVB
T3-3-SOND.../V/SVB-SW
T3-3-SOND.../XZ
T3-9-SOND.../E
T3-9-SOND.../EZ
T3-9-SOND.../EZ/OFS
T3-9-SOND.../XZ
T3-9-SOND.../Z
T3-3-SOND.../Z
T3-4-SOND.../E
T3-4-SOND.../EA/SVB
T3-4-SOND.../EA/SVB-SW
T3-4-SOND.../EZ
T3-10-SOND.../E
T3-10-SOND.../EZ
T3-10-SOND.../EZ/OFS
T3-10-SOND.../XZ
T3-10-SOND.../Z
T3-4-SOND.../EZ/OFS
T3-4-SOND.../I2
T3-4-SOND.../I2/SVB
T3-4-SOND.../I2/SVB-SW
T3-4-SOND.../V/SVB
T3-4-SOND.../V/SVB-SW
T3-4-SOND.../XZ
T3-11-SOND.../E
T3-11-SOND.../EZ
T3-11-SOND.../EZ/OFS
T3-11-SOND.../XZ
T3-11-SOND.../Z
T3-4-SOND.../Z
Moeller HPL0211-2001/2002
07/086
T Rotary Switches
T5B Non-Standard Switches
Type
Price
Type
Price
See Price
List
See Price
List
Std. pack
1 off
T5B rotary switches
T5B-1-SOND.../E
T5B-5-SOND.../E
T5B-1-SOND.../EA/SVB
T5B-1-SOND.../EA/SVB-SW
T5B-1-SOND.../I4
T5B-5-SOND.../EA/SVB
T5B-5-SOND.../EA/SVB-SW
T5B-5-SOND.../V/SVB
T5B-5-SOND.../V/SVB-SW
T5B-5-SOND.../X
T5B-1-SOND.../I4/SVB
T5B-1-SOND.../I4/SVB-SW
T5B-1-SOND.../V/SVB
T5B-1-SOND.../V/SVB-SW
T5B-1-SOND.../X
T5B-5-SOND.../Z
T5B-6-SOND.../E
T5B-1-SOND.../Z
T5B-6-SOND.../EA/SVB
T5B-6-SOND.../EA/SVB-SW
T5B-6-SOND.../V/SVB
T5B-6-SOND.../V/SVB-SW
T5B-6-SOND.../X
T5B-2-SOND.../E
T5B-2-SOND.../EA/SVB
T5B-2-SOND.../EA/SVB-SW
T5B-2-SOND.../I4
T5B-6-SOND.../Z
T5B-2-SOND.../I4/SVB
T5B-2-SOND.../I4/SVB-SW
T5B-2-SOND.../V/SVB
T5B-2-SOND.../V/SVB-SW
T5B-2-SOND.../X
T5B-7-SOND.../E
T5B-7-SOND.../EA/SVB
T5B-7-SOND.../EA/SVB-SW
T5B-7-SOND.../V/SVB
T5B-7-SOND.../V/SVB-SW
T5B-7-SOND.../X
T5B-2-SOND.../Z
T5B-3-SOND.../E
T5B-7-SOND.../Z
T5B-3-SOND.../EA/SVB
T5B-3-SOND.../EA/SVB-SW
T5B-3-SOND.../I4
T5B-8-SOND.../E
T5B-8-SOND.../EA/SVB
T5B-8-SOND.../EA/SVB-SW
T5B-8-SOND.../V/SVB
T5B-8-SOND.../V/SVB-SW
T5B-8-SOND.../X
T5B-3-SOND.../I4/SVB
T5B-3-SOND.../I4/SVB-SW
T5B-3-SOND.../V/SVB
T5B-3-SOND.../V/SVB-SW
T5B-3-SOND.../X
T5B-8-SOND.../Z
T5B-3-SOND.../Z
T5B-9-SOND.../E
T5B-9-SOND.../X
T5B-9-SOND.../Z
T5B-4-SOND.../E
T5B-4-SOND.../EA/SVB
T5B-4-SOND.../EA/SVB-SW
T5B-4-SOND.../I4
T5B-10-SOND.../E
T5B-10-SOND.../X
T5B-10-SOND.../Z
T5B-4-SOND.../I4/SVB
T5B-4-SOND.../I4/SVB-SW
T5B-4-SOND.../V/SVB
T5B-4-SOND.../V/SVB-SW
T5B-4-SOND.../X
T5B-4-SOND.../Z
Notes
These Pages show T rotary switches with non-
For subsequent orders, state contact sequence The contact numbers for non-standard
standard contact sequences (-SOND...) which are number together with country identifer
contact sequences are: >200 <8000 or
>9000 <15000 or >16000.
priced accordingly (See Price List). Use the Initial
Order form on a Page 07/112 for ordering any
T rotary switch combination.
(eg 4711GB)
Moeller HPL0211-2001/2002
07/087
T Rotary Switches
T5 Non-Standard Switches
Type
Price
Type
Price
See Price
List
See Price
List
Std. pack
T5 rotary switches
T5-1-SOND.../E
T5-5-SOND.../E
1 off
T5-1-SOND.../EA/SVB
T5-1-SOND.../EA/SVB-SW
T5-1-SOND.../I5
T5-5-SOND.../EA/SVB
T5-5-SOND.../EA/SVB-SW
T5-5-SOND.../V/SVB
T5-5-SOND.../V/SVB-SW
T5-5-SOND.../X
T5-1-SOND.../I5/SVB
T5-1-SOND.../I5/SVB-SW
T5-1-SOND.../V/SVB
T5-1-SOND.../V/SVB-SW
T5-1-SOND.../X
T5-5-SOND.../Z
T5-6-SOND.../E
T5-1-SOND.../Z
T5-6-SOND.../EA/SVB
T5-6-SOND.../EA/SVB-SW
T5-6-SOND.../V/SVB
T5-6-SOND.../V/SVB-SW
T5-6-SOND.../X
T5-2-SOND.../E
T5-2-SOND.../EA/SVB
T5-2-SOND.../EA/SVB-SW
T5-2-SOND.../I5
T5-6-SOND.../Z
T5-2-SOND.../I5/SVB
T5-2-SOND.../I5/SVB-SW
T5-2-SOND.../V/SVB
T5-2-SOND.../V/SVB-SW
T5-2-SOND.../X
T5-7-SOND.../E
T5-7-SOND.../EA/SVB
T5-7-SOND.../EA/SVB-SW
T5-7-SOND.../V/SVB
T5-7-SOND.../V/SVB-SW
T5-7-SOND.../X
T5-2-SOND.../Z
T5-3-SOND.../E
T5-7-SOND.../Z
T5-3-SOND.../EA/SVB
T5-3-SOND.../EA/SVB-SW
T5-3-SOND.../I5
T5-8-SOND.../E
T5-8-SOND.../EA/SVB
T5-8-SOND.../EA/SVB-SW
T5-8-SOND.../V/SVB
T5-8-SOND.../V/SVB-SW
T5-8-SOND.../X
T5-3-SOND.../I5/SVB
T5-1-SOND.../I5/SVB-SW
T5-3-SOND.../V/SVB
T5-3-SOND.../V/SVB-SW
T5-3-SOND.../X
T5-8-SOND.../Z
T5-3-SOND.../Z
T5-9-SOND.../E
T5-9-SOND.../X
T5-9-SOND.../Z
T5-4-SOND.../E
T5-4-SOND.../EA/SVB
T5-4-SOND.../EA/SVB-SW
T5-4-SOND.../I5
T5-10-SOND.../E
T5-10-SOND.../X
T5-10-SOND.../Z
T5-4-SOND.../I5/SVB
T5-4-SOND.../I5/SVB-SW
T5-4-SOND.../V/SVB
T5-4-SOND.../V/SVB-SW
T5-4-SOND.../X
T5-4-SOND.../Z
Moeller HPL0211-2001/2002
07/088
T Rotary Switches
TM Non-Standard Switches, Bulk Packaged Switches
Type1)
Price
Type2)
Price
See Price
List
See Price
List
Std. pack
1 off
TM mini rotary
switches
TM-1-SOND.../E
TM-1-SOND.../EZ
TM-1-SOND.../IVS
TM-2-SOND.../E
TM-2-SOND.../EZ
TM-2-SOND.../IVS
TM-3-SOND.../E
TM-3-SOND.../EZ
TM-4-SOND.../E
TM-4-SOND.../EZ
TM-5-SOND.../E
TM-5-SOND.../EZ
TM-6-SOND.../E
TM-6-SOND.../EZ
TM-7-SOND.../E
TM-7-SOND.../EZ
TM-8-SOND.../E
TM-8-SOND.../EZ
TM-1-SOND-ERSTBESTELLUNG/E
TM-1-SOND-ERSTBESTELLUNG/EZ
TM-1-SOND-ERSTBESTELLUNG/IVS
TM-2-SOND-ERSTBESTELLUNG/E
TM-2-SOND-ERSTBESTELLUNG/EZ
TM-2-SOND-ERSTBESTELLUNG/IVS
TM-3-SOND-ERSTBESTELLUNG/E
TM-3-SOND-ERSTBESTELLUNG/EZ
TM-4-SOND-ERSTBESTELLUNG/E
TM-4-SOND-ERSTBESTELLUNG/EZ
TM-5-SOND-ERSTBESTELLUNG/E
TM-5-SOND-ERSTBESTELLUNG/EZ
TM-6-SOND-ERSTBESTELLUNG/E
TM-6-SOND-ERSTBESTELLUNG/EZ
TM-7-SOND-ERSTBESTELLUNG/E
TM-7-SOND-ERSTBESTELLUNG/EZ
TM-8-SOND-ERSTBESTELLUNG/E
TM-8-SOND-ERSTBESTELLUNG/EZ
1)
Notes
For subsequent orders, for which the design number is known.
Form FO2 is not required for these.
For initial orders. Form FO2 has to be completed and submitted for these.
2)
Type
Price
Article no.
See Price
List
Std. pack
Bulk packaged
switches
T0-2-1/EA/SVB-GVP50
50 off
50 off
50 off
217168
P1-25/EA/SVB-GVP50
217370
P1-32/EA/SVB-GVP50
217169
P3-63/EA/SVB-GVP25
25 off
25 off
218130
P3-100/EA/SVB-GVP25
218132
Moeller HPL0211-2001/2002
07/089
T Rotary Switches
Fitting Rotary Switches with Coupling (T.../Z or T.../V/SVB) into Enclosures
Notes
CI-K... insulated enclosures are enclosures specifically designed for the installation
of rotary switches, such as T0, T5B and T5 with up to 4 contact units = 8 contacts,
T3 with up to 5 contact units = 10 contacts. They have a high degree of protection
and up to 5 cable entries. If more than 5 cables or large cross-section cables are to
be connected, then we recommend the use of insulated enclosures from the
CI System.
Use the tables below to determine whether, and if so how many, ZAV-... shaft
extensions are required and, for .../SVB switches, the identical quantity of ZVV-...
interlock extensions.
Example:
Switch:
T3-6-.../V/SVB
Minimum mounting depth:
1) Select the required switch and determine the cables
to be connected.
T...-6/Z = 147 mm
Extensions:
No extension is required for an enclosure having a mounting depth of 150 mm. Two
ZAV-T0 shaft extensions and two ZVV-T0 interlock extensions are required for an
enclosure having a mounting depth of 200 mm.
2) Select an enclosure (a HPL0214-2001) according to the minimum mounting
depth of the switch. This depth dimension has to be less than or equal to the
internal mounting depth of the enclosure. In addition, the quantity and size of
the cable entries must be taken into account.
T0-...
mounting depths
T3-...
mounting depths
T5(B)-...
mounting depths
Dimensions in mm
With extension
Number
Without/
With ZAV-T0
Without/
With ZAV-T0
Without/
With ZAV-P3
+1
To
+2
To
+3
To
+4
To
+1
To
+2
To
+3
To
+4
To
+1
To
+2
To
+3
To
+4
To
Switch type
From To
From To
From To
T...-1-.../Z(V/SVB)
T...-2-.../Z(V/SVB)
T...-3-.../Z(V/SVB)
T...-4-.../Z(V/SVB)
T...-5-.../Z(V/SVB)
T...-6-.../Z(V/SVB)
T...-7-.../Z(V/SVB)
T...-8-.../Z(V/SVB)
T...-9-.../Z(V/SVB)
T...-10-.../Z(V/SVB)
T...-11-.../Z(V/SVB)
86
96
102 127 152 177 202
112 137 162 187 212
89
105 130 155 180 205
92
107 132 157 182 207
101 116 141 166 191 216
112 128 153 178 203 228
124 139 164 189 214 239
135 151 176 201 226 251
147 162 187 212 237 262
158 174 199 224 249 274
170 185 210 235 260 285
181 197 222 247 272 297
193 208 233 258 283 308
204 220 245 270 295 320
109 124 149 174 199 224
125 140 165 190 215 240
142 157 182 207 232 257
158 173 198 223 248 273
175 190 215 240 265 290
191 206 231 256 281 306
208 223 248 273 298 323
224 239 264 289 314 339
241 256 281 306 331 356
105 121 146 171 196 221
115 131 156 181 206 231
124 140 165 190 215 240
134 150 175 200 225 250
143 159 184 209 234 259
153 169 194 219 244 269
162 178 203 228 253 278
172 188 213 238 263 288
181 197 222 247 272 279
Moeller HPL0211-2001/2002
07/090
T Rotary Switches
Technical Data
T0-...
T3-...
T5B-...
T5-...
T6-...
T8-...
(T6-160-6)
General technical data
Standards
IEC/EN 60 947, IEC/EN 60 204, CSA, UL
Switch-disconnector to IEC/EN 60 947-3
Load-break switch to IEC/EN 60 947-3
Shipping classifications a SK0200-1043
Lifespan, mechanical
Max. operating frequency
Operations
> 106
3000
5 x 105
3000
5 x 105
3000
5 x 105
3000
> 105
50
> 105
50
Ops./h
Climatic proofing
Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30
Ambient temperature
Open
Min./Max.
Min./Max.
°C
°C
−25/+50
−25/+40
As required
−25/+50
−25/+40
−25/+50
−25/+40
−25/+50
−25/+40
−25/+50
−25/+40
−25/+50
−25/+40
Enclosed
Mounting position
Dimensions
Weight
a Page 07/096
a Page 07/101
a Page 07/103
a Page 15/023
> 154)
> 15
> 15
> 15
Mechanical shock resistance (shock duration 20 ms)
Contacts
g
–
> 15
Rated operational voltage Ue
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
V AC
V
690
6000
690
6000
III/3
32
690
6000
III/3
63
690
6000
690
6000 (8000)2)
690
8000
III/3
III/3
1005)
III/3
125 (160)2)
III/3
3156)
Rated uninterrupted current Iu with max. cable connected
A
20
Load-carrying capacity in intermittent operation, Class 12,
AB 60/40/25
% DF
1.3/1.6/2 x Ie
Short-circuit rating
maximum fuse
A gG/gL 20
25
80
100
200 (160)2)
315
Rated short-time withstand current (1 s current) Icw
Arms
320
440
650
440
1300
440
1850
440
2000 (3000)2)
–
4200
–
Safe isolation to IEC 536 between the contacts
V AC
Protection against direct contact
Finger and back-of-hand proof
to IEC 536
–
–
Switching angles
90°/60°/45°/30°
90°/60°
60° (90°)3
Contact units
Max.
Max.
W
11
22
0.6
11
22
1.1
10
20
4.5
10
20
7.5
3
3
Double-break contacts
Current heat loss per contact at Ie
Terminal capacity
Solid or stranded1)
6
6
11
11
mm2
mm2
mm2
mm2
mm2
1 x
(1 – 2.5)
1 x
(1 – 6)
1 x
1 x
1 x 70 (95)2) 150
2 x 25
1 x 50 (50)2) 120
(2.5 – 35) (2.5 – 35)
2 x
(1 – 2.5)
2 x
( 1 – 6)
2 x
2 x
–
(2.5 – 16) (2.5 – 16)
Flexible with ferrule1)
(ferrule to DIN 46 228)
1 x
(0.75 – 1.5)
1 x
1 x 1 x
(0.75 – 4) (1.5 – 25) (1.5 – 25)
2 x
(0.75 – 1.5)
2 x
2 x
2 x
2 x 16
–
(0.75 – 4) (1.5 – 10) (1.5 – 10)
Flat conductor connection
–
–
–
–
–
1 busbar
25 x 53)
2 busbars
20 x 33)
Terminal screw
M3.5
1
M4
1.5
M6
4
M6 (counter-
sunk M5)2)
M12
Max. tightening torque
Nm
5.6
25
(14)2)
T0-1-...
to
T0-4-...
T3-1-
to
T3-6-
T5B-...
T5-...
T6-...
(T6-160-6)
T8-3-8342
Switch-disconnector
(Main switches)
Switching angles
90°
2
90°
2
90°
2
90°
2
90°
2
90°
2
Max. number of switch positions
Max. number of contacts
for isolating characteristics to IEC/EN 60 947
8
12
20
20
3 (6)2)
6
Isolating characteristics to IEC/EN 60 947
Up to V AC
500
500
690
690
690
690
1)
Notes
T0(3), (6), (8)...: Max. 2 cross-section sizes difference admissible between 2 conductors
T5(B)-...: Max. 1 cross-section size difference admissible between 2 conductors
2)
3)
4)
5)
6)
For T6-160-6/...
For T8-3-8342/...
T3-.../I... > 12 g
T5-4-8344/I5: max. 95 A
Enclosed version: max. 275 A
Moeller HPL0211-2001/2002
07/091
T Rotary Switches
Technical Data
T0-...
T3-...
T5B-... T5-...
T6-...
T8-...
(T6-160-6)
Switching capacity
AC
Rated making capacity
Rated breaking capacity
Motor load switches
cos v = 0.35
A
A
A
A
A
A
130
100
110
80
320
260
260
240
170
32
800
520
600
480
340
63
950
760
740
590
420
100
1600
1280
900
2390
1910
1800
1200
420
230 V AC, cos v= 0.35
400 V AC, cos v= 0.35
500 V AC, cos v= 0.35
690 V AC, cos v= 0.35
Rated operational current Ie
880
60
340
AC-21A Load-break switches
20
125 (160)
315
380 – 440 V, 3
h
AC-3
Motor load switches,
for operational
switching
220 – 240 V, 3
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
A
3
6.5
11
12
18.5
15
22
15
22
7.5
13
15
–
15
22
22
37
22
37
22
37
18.5
22
22
22
18.5
30
22
37
37
55
55
37
37
37
37
75
132
75
37
–
h
220 – 240 V, Yd
4
22
380 – 440 V, 3
4
30
37 (45)
37 (45)
37
h
Star-delta values
Yd : for star-delta
switches without
automatic spring-return
380 – 440 V, Yd
5.5
5.5
7.5
4
45
37
500 V, 3
h
500 V, Yd
55
37
660/690 V, 3
30
22
h
660/690 V, Yd
5.5
3.5
6.5
7.5
–
45
22
AC-23A Motor load switches
(main switches,
220 – 240 V, 3
18.5
30
37
h
h
380 – 440 V, 3
45 (55)
55
maintenance switches)
500 V, 3
37
h
660/690 V, 3
30
30
h
AC-15
DC-1
Control switches
Rated operational current Ie
220 – 240/380 – 415/500 V
6/4/2
10/6/4 16/6/4 16/6/4
–
DC
Load-break switches
L/R = 1 ms
Rated operational current Ie
A
V
10
60
25
60
1
63
60
–
80
60
125
42
315
42
Voltage per contact pair in
series
DC-21A
240 V
24 V
A
A
A
A
A
A
A
1
(1)
(1)
–
–
–
–
–
–
–
–
–
DC-23A Motor load switches
L/R = 15 ms
10 (1) 25 (1) 50 (1)
10 (2) 25 (2) 50 (2)
10 (3) 25 (3) 50 (3)
125 (1)
125 (2)
125 (3)
50 (3)
–
250 (1)
250 (2)
125 (3)
50 (3)
–
48 V
60 V
Figures in brackets:
number of contacts to be
switched in series
120 V
5
(3) 12 (3) 25 (3)
(5) 10 (5) 20 (6)
240 V
5
DC-13
Control switches
L/R = 50 ms
Rated operational current Ie
10
20
25
125
250
Voltage per contact pair in
series
V
32
32
24
–
24
–
Control circuit reliability at
24 V DC, 10 mA
Fault probability
HF
< 10 −5, < 1 fault in 100000 operations
T6-160-6/...
T8-3-8342/...
Auxiliary contacts
Standards
Control circuit isolator to IEC/EN 60 947-5
Rated insulation voltage Ui
V AC
A
500
10
Rated uninterrupted current Iu
with max. cable connected
Rated operational current Ie
A
6/4/3
10
AC-15 with 220 –240/380 – 415/500 V
Short-circuit rating without welding,
Max. fuse
A gG/gL
Terminal capacity
Min. solid or flexible
Max. solid or flexible
mm2
mm2
Nm
HF
0.75/0.5
2.5/1.5
Max. tightening torque
0.35
Control circuit reliability at
24 V DC, 10 mA
Fault probability
< 10 −5, < 1 fault in 100 000 operations
Moeller HPL0211-2001/2002
07/092
P Switch-Disconnectors
Technical Data
P1-25
P1-32
P3-63
P3-100
General technical data
Standards
IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA, UL
Switch-disconnector to IEC/EN 60 947-3
Lifespan, mechanical
Max. operating frequency
Climatic proofing
Operations
3 x 105
3 x 105
105
105
50
Ops./h
50
50
50
Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30
Ambient temperature
Open
Min./Max.
Min./Max.
°C
°C
−25/+50
−25/+40
−25/+50
−25/+40
−25/+50
−25/+40
−25/+50
−25/+40
Enclosed
Mounting position
Dimensions
Weight
As required
a Page 07/104
a Page 15/023
> 20
Mechanical shock resistance (half-sinusoidal shock 20 ms)
Contacts
g
> 20
> 20
> 20
Rated operational voltage Ue
V AC
V
690
690
690
690
Rated impulse withstand voltage Uimp
Overvoltage category/pollution degree
Rated uninterrupted current Iu with max. cable connected
6000
III/3
6000
III/3
6000
III/3
6000
III/3
A
25
32
63
100
Load-carrying capacity in intermittent operation, Class 12, AB 60/40/25 % DF
Short-circuit rating Max. fuse
x Ie
A gG/gL
Arms
1.3/1.6/2
25
1.3/1.6/2
50
1.3/1.6/2
80
1.3/1.6/2
100
Rated short-time withstand current (1 s current) Icw
640
640
1260
690
2000
690
Isolating characteristics to IEC/EN 60 947
Up to VAC 690
690
Safe isolation to IEC 536 between the main contacts and the auxiliary contacts V AC
Protection against direct contact
440
440
440
440
Finger and back-of-hand proof to IEC 536
Switching angles
90°
90°
90°
90°
Contacts (current paths)
Current heat loss per contact at Ie
Terminal capacity
Max.
W
3(+N)
1.1
3(+N)
1.8
3(+N)
4.5
3(+N)
7.5
Solid or stranded1)
mm2
mm2
mm2
mm2
1 × (1.5 – 6)
2 × (1.5 – 6)
1 × (1 – 4)
2 × (1 – 4)
M4
1 × (1.5 – 6)
2 × (1.5 – 6)
1 × (1 – 4)
2 × (1 – 4)
M4
1 × (2.5 – 35)
2 × (2.5 – 10)
1 × (1.5 – 25)
2 × (1.5 – 6)
M5
1 × (2.5 – 35)
2 × (2.5 – 10)
1 × (1.5 – 25)
2 × (1.5 – 6)
M5
Flexible with ferrule1)
(ferrule to DIN 46 228)
Terminal screw
Max. tightening torque
Nm
1.6
1.6
4
4
Notes
Main switch characteristics to IEC/EN 60 204;
positive opening of contacts, operator element positively located on shaft
1) P1-...:
Max. 2 cross-section sizes difference admissible
when using 2 conductors
P3-...:
Max. 1 cross-section size difference admissible when
using 2 conductors
Moeller HPL0211-2001/2002
07/093
P Switch-Disconnectors
Technical Data
P1-25
P1-32
P3-63
P3-100
Switching capacity
AC
Rated making capacity
Rated breaking capacity
Motor load switches
cos v = 0.35
A
A
A
A
A
A
240
190
150
170
150
25
320
260
300
290
250
32
800
640
600
590
340
63
950
760
740
880
520
100
230 V AC, cos v= 0.35
400 V AC, cos v= 0.35
500 V AC, cos v= 0.35
690 V AC, cos v= 0.35
Rated operational current Ie
AC-21A
AC-3
Load-break switches
380 – 440 V, 3
h
Motor load switches,
for operational
switching
220 – 240 V, 3
kW
kW
kW
kW
kW
kW
kW
kW
5.5
7.5
7.5
7.5
7
7.5
13
15
30
30
30
18.5
37
37
30
22
37
45
37
30
50
65
75
h
380 – 440 V, 3
h
500 V, 3
18.5
15
h
660/690 V, 3
h
AC-23A
Motor load switches
(main switches,
maintenance switches)
220 – 240 V, 3
8.5
15
h
h
380 – 440 V, 3
13
11
11
500 V, 3
18.5
18.5
h
660/690 V, 3
h
DC
DC-1
Load-break switches
L/R = 1 ms
Rated operational current Ie
A
V
25
60
32
60
63
60
100
60
Voltage per contact pair in
series
DC-23A
Motor load switches
L/R = 15 ms
24 V
48 V
60 V
120 V
A
A
A
A
25 (1)
25 (2)
25 (3)
12 (3)
25 (1)
25 (2)
25 (3)
12 (3)
50 (1)
50 (2)
50 (3)
25 (3)
50 (1)
50 (2)
50 (3)
25 (3)
Figures in brackets:
number of contacts to
be switched in series
N-P1...
N-P3...
Switched neutral
Switching capacity
As P1-32
HI11-P1/P3
As P3-100
Auxiliary contacts
Standards
Control circuit isolator to IEC/EN 60 947-5
Rated insulation voltage Ui
V AC
A
500
10
Rated uninterrupted current Iu with max. cable connected
Rated operational current Ie
AC-15
DC-13
220 – 240/380 – 415/500 V
A
A
A
6/4/3
0.55
1.1
250 V DC
125 V DC
Short-circuit rating without welding,
Max. fuse
A gG/gL
mm2
mm2
Nm
10
Terminal capacity
Min. solid or flexible
Max. solid or flexible
0.75/0.5
2.5/1.5
Max. tightening torque
0.6
Control circuit reliability at
24 V DC, 10 mA
Fault probability
HF
< 10−5, < 1 fault in 100 000 operations
Moeller HPL0211-2001/2002
07/094
T Rotary Switches, P Switch-Disconnectors
Tripping Characteristics
Component lifespan in relation to breaking current and utilization category 1)
In order to achieve a reasonable lifespan in utilization category AC-4 (severe duty: 100 % inching, reversing or plugging), the stalled motor current should not exceed
the rated current of the switch at AC-21.
10
10
8
T0
T3
8
6
5
6
5
4
3
4
3
2
1
2
1
0.8
0.6
0.5
0.5
1
2
3
4
5
6
7
8
10
20 A
1
2
3
4
6
8
12 16 20 25 30 40 A
Breaking point
Breaking point
As control switch (AC-15)
As motor load switch (AC-3)
As load-break switch (AC-21)
As motor load switch (AC-3)
As load-break switch (AC-21)
5
10
8
T5B, T5
T6, T8
3
2
6
5
T8
T8
4
3
T6
T6
1
T5B
T5
2
0.5
T5
0.3
0.2
T5B
1
0.8
0.6
0.5
0.1
4
6
8
12 16 20
30 40
60
100
T8
250A
T8
1
2
3
4
6
8
12 16 20
30 40
60 80 100 A
Breaking point
As motor load switch (AC-3)
As load-break switch (AC-21)
Breaking point
As motor load switch (AC-3)
As load-break switch (AC-21)
T6
T5B T5
T5B
T6
T5
2
10
P3
P1
8
P3-63
6
5
4
3
1
0.8
0.6
0.5
0.4
P3-100
P1-32
2
P1-25
0.3
1
0.8
0.2
0.6
0.5
0.1
1
2
3
4
6
8
12 16 20 25 30 40 A
P1-25 P1-32
1
2
3
5
10
20
40
P3-63
60 80 100
P3-100
A
Breaking point
As motor load switch (AC-3)
As load-break switch (AC-21)
Breaking point
As motor load switch (AC-3)
As load-break switch (AC-21)
P3-100
P1-25
P3-63
Notes
1) AC-3 and AC-21 at 400 V, AC-15 at 230 V
Moeller HPL0211-2001/2002
07/095
TM Mini Rotary Switches
Technical Data
General technical data
Standards
IEC/EN 60 947, UL, CSA
Control switches to IEC/EN 60 947-5-1
Control circuit isolators to IEC/EN 60 947-5-1
Control circuit isolators (IEC/EN 60 947-5-1)
Maximum 6 contacts; switching angle 90°
Lifespan, mechanical
Max. operating frequency
Climatic proofing
Operations
Ops.
> 1 x 106
Ops./h
3000
Damp heat, constant, to IEC 60 068 Part 2-3
Damp heat, cyclical, to IEC 60 068 Part 2-30
Ambient temperature Open
Enclosed
Min./Max.
Min./Max.
°C
°C
−25/+50
−25/+40
Mounting position
As required
Mechanical shock resistance (shock duration 20 ms)
Protection against direct contact
g
> 15
Finger and back-of-hand proof to IEC 536
Terminal capacity
Solid
1 conductor
Min./Max.
mm2
mm2
mm2
mm2
0.75/1.5
2 conductors Max.
1 conductor Min.
2 conductors Max.
1.5
(AWG 14)
(AWG 18)
Flexible
0.75
0.75
M2.5
0.35
Terminal screw
Max. tightening torque
Dimensions
Nm
a Page 07/108
Contacts
Mechanical values
Contacts
Max.
Max.
16
Contact units
8
Switching angles
90°/60°/45°/30°
Min. switching angle for On-Off-On
Switch positions
60°
12
Max.
Thickness of gold coating
Electrical values
mm
35
Rated operational voltage Ue
V AC
kV
500
Rated impulse withstand voltage Uimp
applicable to systems with earthed neutral point
Overvoltage category/pollution degree
Rated insulation voltage Ui
4
III/3
V AC
A
500
10
(UL/CSA 300 V AC)
Rated uninterrupted current Iu with max. cable connected
Switching capacity
AC-23A
220 – 240 V, 3
380 – 440 V, 3
kW
kW
kW
kW
kW
A
1.8
3
h
h
Motor load switches
500 V, 3
3.7
0.75
1.1
2.5
1.5
1
h
220 – 240 V, 1
380 – 440 V, 1
220 – 240 V, 1
380 – 415 V, 1
h
h
h
h
AC-15
Control switches
A
440 V, 1
A
h
DC-1
1 – 24 V DC
A
10
Load-break switches
110 – 240 V DC
A
0.7 – 0.3
3
DC-13
Control switches
L/R = 50 ms
Max. 32 V DC per contact
A
Switching capacity for North America
240 V, 3
HP
HP
A
1
h
h
277 V, 1
o
300 V AC
Short-circuit protective device
Maximum fuse
10 Heavy duty
A gG/gL 10
HF
< 10−5, < 1 fault in 100 000 operations
Control circuit reliability
24 V DC, 10 mA
Fault
probability
Moeller HPL0211-2001/2002
07/096
T0, T3 Rotary Switches
Dimensions
Flush mounting
T0.../E (+ H3-T0)
T3.../E (+ H3-T0)
Drilling dimensions
H3-T0
101
3.1 – 3.5
25
5
ZFS-...-T0
12.2
48
c20
35
75
Centre mounting
T0.../EZ (/OFS)
T3.../EZ (/OFS)
T0
T3
Drilling dimensions
1.5 – 5
3.2
61
22.3 +0.4
48
48
0
c21
35
T.../EZ/OFS
35
Type
c20
c21
Type
c20
c21
T0-1...
T0-2...
T0-3...
T0-4...
T0-5...
T0-6...
T0-7...
T0-8...
T0-9...
T0-10...
T0-11...
41
61
T3-1...
T3-2...
T3-3...
T3-4...
T3-5...
T3-6...
T3-7...
T3-8...
T3-9...
T3-10...
T3-11...
44
64
50
70
56
76
60
80
67
87
99
69
89
79
79
99
90
110
122
133
145
156
168
179
88
108
118
127
137
146
156
102
113
125
136
148
159
98
107
117
126
136
Depth of one contact unit: 9.5 mm
Depth of one contact unit: 11.5 mm
Moeller HPL0211-2001/2002
07/097
T0, T3 Rotary Switches
Dimensions
Service distribution board mounting
T0.../IVS
Drilling dimensions
Base
c22
48
55
5
ɂ 5
M4
54
28
ɂ 5
T3.../XZ + IVS-T0
Drilling dimensions
Base
63
48
c22
5
55
ɂ 5
54
M4
28
63
ɂ 5
Rear mounting
T0.../Z
T3.../Z
Drilling dimensions Drilling dimensions
Base Door
T0
5
5
ZFS-...-T0
O 5
5 – 5.5
a
M4
25
48
36
48
5
O
T3
5
O
5 – 5.5
c23
c24
35
M4
38,
ZAV:
54
154
63
36
O 5
ᕃ Can be extended
using ZVV-T0,
F 4 x 25 = 100 mm
Type
c20
c21
c22
c23
c24
f/F
c24 with
F 4 ZAV
c25
Type
c20
c21
c22
c23
c24
f/F
c24 with
F 4 ZAV
c25
T0-1...
T0-2...
T0-3...
T0-4...
T0-5...
T0-6...
T0-7...
T0-8...
T0-9...
T0-10...
T0-11...
41
61
77
48
86 – 102
96 – 112
202
212
72
72
91
91
–
T3-1...
T3-2...
T3-3...
T3-4...
T3-5...
T3-6...
T3-7...
T3-8...
T3-9...
T3-10...
T3-11...
44
64
80
51
86 – 105
205
79
79
101
101
–
50
70
87
57
56
76
92
63
101 – 115 216
112 – 128 228
124 – 139 239
135 – 151 251
147 – 162 262
158 – 174 274
170 – 185 285
181 – 196 296
193 – 208 308
204 – 219 319
60
80
96
67
105 – 121 221
115 – 131 231
124 – 140 240
134 – 150 250
143 – 159 259
153 – 169 269
162 – 178 278
172 – 188 288
181 – 197 297
67
87
99
103
115
126
138
149
161
172
184
195
74
69
89
106
115
125
134
144
154
163
173
76
79
86
79
99
86
90
110
122
133
145
156
168
179
97
88
108
118
127
137
146
156
95
–
102
113
125
136
148
159
109
120
132
143
155
166
–
98
105
114
124
133
143
–
–
107
117
126
136
–
–
–
–
–
–
–
–
Depth of one contact unit: 9.5 mm
Depth of one contact unit: 11.5 mm
Moeller HPL0211-2001/2002
07/098
T0, T3 Rotary Switches
Dimensions
Flush mounting main switches
T0.../EA/SVB
T3.../EA/SVB
Drilling dimensions
Door
ZFS-...T0
48
3.1 – 3.5
5
T0
T3
ON
I
49
61
o
OFF
o
12.2
25
c20
65
35
Rear mounting main switches
T0.../V/SVB
T3.../V/SVB
Drilling dimensions Drilling dimensions
Base Door
ɂ 5
ZFS-...T0
48
5 – 5.5
5
T0
T3
5
25
M4
ON
I
o
OFF
49
36
o
ɂ 5
65
c23
35
c24
38, 54
ZVV+ZAV: 154
M4
ቢ
63
ᕃ Interlock can be extended using ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm
ɂ 5
Sheet steel enclosures
T0-.../ST, P1-.../ST
P3-.../ST
M20
M20
M25
M4
M4
60
140
M20
104
162
M25
M20
184
184
T3-.../ST, T5(B)-.../ST
M4
M25
M32
M25
140
193
184
Moeller HPL0211-2001/2002
07/099
T0, T3 Rotary Switches
Dimensions
Surface mounting
T0.../I1
Drilling dimensions
Base
M4
L-...
M20
c25
27
80
T3.../I2
Drilling dimensions
Base
M4
L-...
∅8
M25
100
c25
c33
Surface mounting main switches
Drilling dimensions
Base
T0.../I1/SVB
M4
L-...
M20
ON
I
o
OFF
o
c25
35
80
T3.../I2/SVB
Drilling dimensions
Base
F 3 padlocks
M4
L-...
d
d = 4 – 8 mm
8
b + d F 47 mm
ON
I
M25
o
OFF
o
100
c25
35
Type
c25
Type
c25
c33
T0-1...
T0-2...
T0-3...
T0-4...
75
75
95
95
T3-1...
T3-2...
T3-3...
T3-4...
T3-5...
80
27
27
35
35
35
80
100
100
145
Moeller HPL0211-2001/2002
07/100
T0, T3 Rotary Switches, Accessories
Dimensions
Key operation
S-T0
S-SOND...-T0
T0.../E(I1) + S-(SOND-)T0
T3.../E(I2) + S-(SOND-)T0
T0.../Z + S-(SOND-)T0
T3.../Z + S-(SOND-)T0
T0.../EZ
־
T0../E + EZ-T0 + S-(SOND-)T0 T3.../EZ
־
T3../E + EZ-T0 + S-(SOND-)T0 ZFS-...-T0
2 – 5
5
5
19
36
27
44
27
48
ɂ22:25 – 28
ɂ30:23 – 26
30
c20
5 – 5.5
3.1 – 3.5
3.2
3.2
36
12.2
22.3 + 0.4
30.5
0
Cylinder lock
SVA-T3
T0.../I1/SVA
T3.../I2/SVA
T0.../E/SVA...
T3.../E/SVA...
T0.../Z/SVA...
T3.../Z/SVA...
56
56
56
ZFS...-T0
30
46
30
46
48
30
46
Push-button interlock
Padlocking feature
Dimensions as DTV-T3
DTV-T3
SVC-T3
T0.../I1/DTV
T3.../I2/DTV
T0.../I1/SVC
T3.../I2/SVC
T0.../E/DTV...
T3.../E/DTV...
T0.../E/SVC...
T3.../E/SVC...
T0.../Z/DTV...
T3.../Z/DTV...
T0.../Z/SVC...
T3.../Z/SVC...
56
56
56
ZFS...-T0
46
46
48
46
Mounting clearance
b
a
a
b
ᕃ Mounting clearances a and b: 4 mm
ᕄ Exposed conductive part (metal)
Moeller HPL0211-2001/2002
07/101
T5B, T5 Rotary Switches
Dimensions
Flush mounting
T5(B).../E
Drilling dimensions
Door
18
4.1 – 4.5
12 – 13
ON
I
o
OFF
14
88
5
c2
37
Rear mounting
T5(B).../Z
Drilling dimensions
Base
Drilling dimensions
Door
a
c20
5
ɂ 6.4
5 – 5.5
ON
I
o
OFF
25
25
48
88
79
c2
37
38,
ZAV:
54
154
ᕃ Shaft can be extended using ZAV-P3, F 4 x 25 = 100 mm
Flush mounting main
switches
Drilling dimensions
Door
T5(B).../EA/SVB
88
5
c2
4.1 – 4.5
12 – 13
25
ON
I
o
OFF
o
14
44
100
40.5
16.5
Rear mounting main switches
T5(B).../V/SVB
Drilling dimensions
Base
Drilling dimensions
Door
5
c20
5
5 – 5.5
85
ON
I
o
OFF
o
25 25
48
88
44
ቢ
100
12
16.5
40.5
ᕃ Can be extended
using ZVV-P3,
F 4 x 25 = 100 mm
Moeller HPL0211-2001/2002
07/102
T5B, T5 Rotary Switches
Dimensions
Surface mounting
T5(B).../I4
T5.../I5
L-...
L-...
M25
M50
M25
M32
M20
M20
c22
37
c22
37
160
200
Surface mounting main switches
T5(B).../I4/SVB
Drilling dimensions
F 3 padlocks
L-...
M5
d
d = 4 – 8 mm
b + d F 47 mm
ON
I
o
OFF
o
142
160
c22
44
T5.../I5/SVB
Drilling dimensions
L-...
M5
ON
I
o
OFF
o
182
c22
44
200
External fixing bracket
Type
c2
c20
f/F
c24 with
F 4 ZAV
c21
c22
7.8
4.6
T5(B)-1... 54
T5(B)-2... 71
T5(B)-3... 87
T5(B)-4... 104
T5(B)-5... 120
T5(B)-6... 137
T5(B)-7... 153
T5(B)-8... 170
T5(B)-9... 186
T5(B)-10... 203
92 – 107
207
90
90
123
123
–
125 (95)
109 – 124 224
125 – 140 240
142 – 157 257
158 – 173 273
175 – 190 290
191 – 206 306
208 – 223 323
224 – 239 339
240 – 356 356
125 (95)
160 (160)
160 (160)
–
–
–
–
–
–
–
–
–
–
6
34
–
50
Depth of one contact unit: 16.5 mm
∅6
M5
The rotary switches T5B and T5 are of identical design
but differ in their contacts
Moeller HPL0211-2001/2002
07/103
T6, T8 Rotary Switches
Dimensions
Flush mounting
T6.../E
T8.../E
a2
5
150
c2
c30
Flush mounting main switches
T6-2/EA/SVB
ZS
5.4
68
88
5
88
90
100
50
Rear mounting main switches
T6-2/V/SVB
F 3 padlocks for T.../SVB
ZS
d
5.4
d = 4 – 8 mm
b + d F 47 mm
5
4.5
68
88
88
90
110
40
50
100
T6-160-6/V/SVB-SW/HI11
T8-3-8342/V/SVB-SW/HI11
6.4
H-T6-100
19
7
H-T8
76
224
93
9
4.5
216
200
73
9.2
86.5
172.8
104
130
250
5.5
1
315
218
7
5
1
Drilling dimensions
Door
Type
a2
b2
c2
2 BE
3 BE
c30
d1
d2
x1
y1
d2
BE = Number of contact units
T6...
T8.../E
T8.../SVB
88
130
–
88
130
–
100
–
–
152
173
–
44
62
–
∅ 26–30 ∅ 6.0 68
∅ 22–25 ∅ 7.0 104
∅ 38–42 ∅ 7.0 68
68
104
68
d1
x1
T6: 4 M5 x 20
T8: 4 M6 x 20
Moeller HPL0211-2001/2002
07/104
P Switch-Disconnectors
Dimensions
Flush
mounting
P.../E
Centre mounting
P1.../EZ
Drilling dimensions
Door
P1-.../E
P1-.../EZ
P3-.../E
5
6
3
1
2
L3
T3
L2
T2
L1
T1
ON
I
4.1 – 4.5
3.1 – 3.5
3.2
0
OFF
12 – 13
4
5
c21
a3
a2
c2
22.3 +0.4
14
12.2
0
P1.../EZ = c2 + 5 mm
Service distribution board mounting
P1.../IVS
P3.../IVS
F 3 padlocks
5
c3
c3
d
c23
5
L1
L2
L3
c22
a32
a32
d = 4 – 8 mm
b + d F 47 mm
L1
L2
L3
L1
L2
L3
HI11
N
T1
T2
T3
28
49
T2
T3
T1
T2
T3
T1
a31
a4
55
Rear mounting
P.../Z
Drilling dimensions
Base
P1.../Z
Drilling dimensions
Door
5
5 – 5.5
ቢ
M4
22.3 +0.4
0
c31 c32
36
5
P3.../Z
a2
a3
5 – 5.5
M4
3
c21
c25
c20
38
154
25
48
ᕃ Shaft can be extended using ZAV-..., F 4 x 25 = 100 mm
Type
a2
a3
a4
a21
a22
a23
a31
a32
a33
b2
b3
b21
b22
b23
b24
b31
P1
P3
48
87
49
72
53.5
71.5
65
87
48
87
87
125
15
18
15
15
83
114
48
87
70
83
65
87
17
27
125
175
32
–
49
60
Type
c2
c3
c20
f/F
c20 with
F4
ZAV/ZVV
c21
c22
c23
c24
c25
c27
c28
c31
c32
c33
P1
P3
59
59
86
82
96 – 112
212
35
37
32
41
65
63
68
81
58
65
35
44
77
90
25
25
25
25
27
29
103 – 118 218
Moeller HPL0211-2001/2002
07/105
P Switch-Disconnectors
Dimensions
Flush mounting main switches
P.../EA/SVB
Drilling dimensions
Door
ZFS-....
P1...
P3...
a22
H-P...
3.1 – 3.5
4.1 – 4.5
ON
5
3
1
I
y
y
N
N
12 – 13
o
OFF
o
6
2
4
12.2
14
a21
a3
5
25
c2
c27
Rear mounting main switches
P.../V/SVB
Drilling dimensions
Base
Drilling dimensions
Door
c 27
ZFS-....
a 22
5
5
P1.../V/SVB
H-P...
ᕃ
5 – 5.5
ON
3
5
I
1
M4
22.3 +0.4
N
N
o
0
OFF
36
o
2
6
4
3
P3.../V/SVB
c 25
a 21
a 3
5 – 5.5
c 20
38
154
M4
25
48
ᕃ Interlock can be extended using ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm
Surface mounting
Surface mounting main switches / safety
switches
P1.../I2/SVB
P1.../I2/SI
Drilling dimensions
P1.../I2
L-...
M4
M25
8
M25
M25
a23
c28
c33
c27
Moeller HPL0211-2001/2002
07/106
P Switch-Disconnectors
Dimensions
Surface mounting
P3-63/I4
Surface mounting main switches/safety
switches
Drilling dimensions
P3-63/I4/SVB
P3-63/I4/SI
T5B-.../I4/SI
L-...
M5
M25
M32
M20
142
L—PKZ0
95
37
95
44
a23
Surface mounting
Surface mounting main switches/safety
switches
Drilling dimensions
P3-100/I5/SVB
P3-100/I5/SI
T5-.../I5/SI
P3-100/I5
L-...
M5
M25
M50
M20
182
L—PKZ0
125
37
125
44
a23
Type
a2
a3
a4
a21
a22
a23
a31
a32
a33
b2
b3
b21
b22
b23
b24
b31
P1.../I2
P3-63/I4
P3-100/I5
48
87
87
49
72
72
53.5
71.5
71.5
65
87
87
48
87
87
100
160
200
15
18
18
15
15
15
83
114
114
48
87
87
70
83
83
65
87
87
17
27
27
180
240
280
35.5
35.5
35.5
49
60
60
Type
c2
c3
c20
f/F
c20 with
F4
ZAV/ZVV
c21
c22
c23
c24
c25
c27
c28
c31
c32
c33
P1...
P3-63
P3-100
59
59
59
86
82
82
96 – 112
212
35
37
37
32
41
41
65
63
63
68
81
81
58
65
65
35
44
44
80
125
125
25
25
25
25
25
25
27
37
37
103 – 118 218
103 – 118 218
Moeller HPL0211-2001/2002
07/107
P Switch-Disconnectors, Accessories
Dimensions
Cylinder lock
SVA-T3
P1.../I2/SVA
P1.../E/SVA
P1.../Z/SVA
56
56
56
ZFS...-T0
30
46
30
46
30
48
46
Padlocking feature
SVC-T3
P1.../I2/SVC
P1.../E/SVC
P1.../Z/SVC
56
56
56
ZFS...-T0
46
46
48
46
Modules
Switched neutral N-P...
HI 11-P1/P3 auxiliary contacts
F 3 padlocks
a33
a3
d
d = 4 – 8 mm
b + d F 47 mm
H-P...
HI 11
5
6
3
4
1
2
1
2
3
4
5
L3
T3
L2
T2
L1
T1
N
N
N-P
6
a32
a32
a31
a31
a32
a32
Type
a3
a31
a32
a33
b31
P1-...
P3-..
49
72
15
18
15
15
83
114
49
60
Moeller HPL0211-2001/2002
07/108
TM Mini Rotary Switches
Dimensions
Flush mounting
TM.../E
Drilling dimensions
3
8
3.2
M3 M3
20
28
c20
30
Control circuit isolators
Lockable using 2 padlocks ∅ 4 mm or 1 padlock ∅ 6 mm
TM-.../E/SVB(-SW)
Drilling dimensions
3
10
4.2
M4 M4
30
38
48
c21
35
Centre mounting
TM-.../EZ
Drilling dimensions1)
3.2
1.7
F 5.5
17/19
16.2+0.2
0
22.3 +0.4
0
Centre mounting with key operation
TM-...+EZ/S-..
Drilling dimensions1)
17/19
3.2
5.5
1.7
16.2+0.2
0
22.3 +0.4
0
30
c20
12
35
Type
c20
c21
TM-1...
TM-2...
TM-3...
TM-4...
TM-5...
TM-6...
TM-7...
TM-8...
39
42
54
66
51
63
75
87
99
111
123
Depth of one contact unit: 12 mm
Service distribution board mounting
TM-.../IVS
O
Type
S
H
HAND
AUTO
TM-1...
TM-2...
44
46
21
26.5
Depth of one contact unit: 12 mm
35
S
H
Notes
1)) Drilling dimension options: 16.2 mm = use without adapter
־
RMQ16; 22.3 mm = adapter required ־
RMQ-Titan Moeller HPL0211-2001/2002
07/109
P..., T5..., P7 Safety Switches
Engineering Notes
Maintenance and safety switches have the same
electrical function. They are designed to isolate
electrical installations (loads) safely from the mains
while maintenance work or repairs are being carried
out, thereby ensuring that no hazard arises to
personnel, machinery or product.
The safety switch is an additional, enclosed main
switch = isolator for an individual electrical load, and
can be fitted directly next to the motor or the
electrical load, ensuring that work on them can be
carried out safely provided the 5 safety rules to
VDE 0105 are observed. This is of special importance
if there is any possibility whatsoever of the main
switch being wrongly identified.
Features
4) The uninterrupted current, provided that the
Safety switches are housed in insulated enclosures as
standard and bear the inscription “Safety switch” on
a bright orange label. Labels in other languages are
available.
switch is safely prevented from switching under
load.
5) This can be achieved for example by padlocking
the handle (which may need to be changed
accordingly) in the On position.
Switches to be used for Emergency-Stop switching
have a special red handle and a yellow locking collar
in accordance with STOP category 0 to
IEC/EN 60204.
If the switch is not admissible for use as an
Emergency-Stop switch, both parts are grey for
P7 switch-disconnectors (Type suffix “-GR”) or black
for T and P switches (Type suffix “-SW”).
The cover and handle are interlocked when a padlock
is in place.
This is not admissible for switches with a
red/yellow handle.
Old Type/New Type
Old Type
New Type
P3-63/I-SI(-SW)(+HI..)
P3-63/I-SI(-SW)+N-P3
P3-63/I4-SI(-SW)(+HI..)
P3-63/I4-SI(-SW)+N-P3
P3-63/I-SI(-SW)
+N+HI11
P3-63/I4-SI(-SW)
+N+HI11
Application
By securing the switch in the Off position with his
own padlock (up to three can be fitted), the fitter/
electrician can protect himself against the possibility
of any other person switching On the machine
without authority.
Selection
Switches must be selected according to the following
criteria:
T5B-3-8342/I-SI(-SW)
T5B-4-.../I-SI(-SW)
P3-63/I-SI(-SW)(+HI..)
P3-63/I-SI(-SW)+N-P3
T5-.../CI19/SIH
T5B-3-8342/I4-SI(-SW)
T5B-4-.../I4-SI(-SW)
P3-63/I4-SI(-SW)(+HI..)
P3-63/I4-SI(-SW)+N-P3
T5-.../I5-SI
1) The motor switching capacity, where the switch is
fitted in such a way that the operator may use it
for operational On and Off switching.
Maintenance switches are merely additional,
enclosed main switches with a padlocking facility.
Such switches can be found on Pages 07/012–015 or
07/024–025 of this catalogue.
2) The motor rating applies for 3 poles as standard.
Where the motor rating is divided between
6 poles, such as for a motor with star-delta
starting, the 1.73 fold rating can be controlled
with a 6-pole switch.
T5-3-8342/CI19/SIH
T5-.../CI19/SIH
T5-3-8342/I5-SI
T5-.../I5-SI
3) The uninterrupted current, where the switch has a
load-shedding contact (LA). The load-shedding
contact is an auxiliary contact, which is closed in
the On position and opens early when switching
Off, so that a contactor in the circuit takes over
the switching capacity, and the maintenance/
safety switch operates at zero load. When
switching On, the LA closes later than or at the
same time as the main contacts. With T and P
switches, this is achieved by the auxiliary make
contact, with P7... switches, it is achieved by
series connection of the early-make auxiliary
contact (VHI) and a standard auxiliary contact
(NHI).
Technical data
for P switch-disconnectors
a Page 07/092
Technical data
for T5(B) switch-disconnectors a Page 07/090
Dimensions for P
a Page 07/104
a Page 07/101
a Page 10/016
Dimensions for T5(B)
P7 Safety Switches
63 A – 250 A
Safety switch with load shedding and indication
L1
L2
L3
N
FAZ-
F1
F2
F0
B4HI
95
1
2
3
4
5
6
F2
O
K1M
96
21
22
13
14
13
I
K1M
14
1
3
5
7
8
9
11
12
Q1
2
4
6
10
U
V
W
A1
A2
K1M
H1
H2
M
3
Indication
On Off
Load shedding
Moeller HPL0211-2001/2002
07/110
T Rotary Switches, TM Mini Rotary Switches
Ordering of Non-Standard Contact Sequences
Key to type references
T . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ./ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+ . . . . . . . . . . . . . . . . . .
Ȇ
Ȇ
Ȇ
Ȇ
Ȇ
Switch size
Number of contact units
Contact sequence number
With manufacturing country identifier.
For initial order enclose completed form
(see next Page).
Mounting form
Accessories
(2 contacts per contact unit)
• Mounting form /E
a Page 07/056 – 071
State in full with every
order!
• Centre mounting /EZ (for T0, T3)
• Surface mounting /I...1)
• Service distribution board
mounting /IVS (for T0)
Max.
units
Max.
contacts
Contact sequence number is issued by
factory.
For TM.../EZ
only +EZ/S... is possible
a Page 07/083
T0
11
11
10
10
8
22
22
20
20
16
For subsequent orders, Type suffix is
sufficient.
• Rear mounting /Z
T3
• Flush mounting main switches .../EA/
T5B
T5
SVB2)
• Surface mounting main switches /I.../
SVB
TM
• Rear mounting main switches/V/SVB2)
• Mounting forms for TM: /E, /EZ or /IVS
Design notes for non-standard contact sequences
Contact sequence
Terminal markings
Number of contact units
The Form FO 2 (see next Page) makes it easy to
determine the contact sequence.
Master copy a Page 07/112
TM switches have consecutive terminal markings,
beginning with 1.
Number of contacts = Round up to nearest whole
2
Spring-return
Each contact chamber = contact unit has 1 or 2
contacts, each operated by a cam.
On T5(B) one cam operates both contacts.
Consequently:
Where the total switching angle is less than 180°,
the contacts can be operated independently of one
another. At switching angles of 180° and above, two
contacts per chamber are possible only if their
switching sequences are the same, but offset by 180°
(e.g. T5B-4-8235 step switch).
Switching angles
30, 45, 60, 90°
Preferred angle: 60°
For On/Off switches: 90°
For main switches: 90° as FS 908 Page a 07/054
Interruption of contact between 2 switch positions
(On-Off-On) not admissible on T0;
or on T3 and TM at switching angles of 30°, 45°; or
on T5(T5B) at a switching angle of 30°
The switching movement is limited by a stop. The
switch returns under spring pressure to the last
indexed position. Where a switch has spring-return
from both directions, a maximum of three positions
can be traversed.
The return angle is < m switching angle. A maximum
of 6 contacts can be returned at the same time.
Fleeting contacts
Duration of contact depends primarily on the speed of
actuation. If a contactor is to be actuated by means of
fleeting contact, the switching angle of the rotary
switch must not be less than 60°, or the switching
pulse may be too short. Fleeting contacts always act
in both directions.
Standard features
As for rotary switches with standard contact
sequences
a Page 07/006, 072
Notes
Page
Complete rotation
Technical data
Dimensions
07/090
07/096
Possible only with a total switching angle of 360°.
Unrestricted rotation in either direction. The number
of switch positions multiplied by the switching angle
must equal 360°. TM with 12 positions every 30° is
possible only with complete rotation, not with stop.
Available mounting forms
T0
T3
07/084
07/085
07/086
07/087
07/088
T5B
T5
TM
Notes
The sequence of the contacts may be changed if
technical reasons so dictate.
Links between an even number and an odd number
(e.g. 2-3) cannot be provided ex-factory, and must be
supplied by the user.
For non-standard switches it is preferable to arrange
the links so that terminals whose numbers differ by 4
are linked with one another, e.g. terminals 1-5-9; 2-6-
10; 3-7-11- or 4-8-12-. Such links can be removed
(also applies for standard switches), whereas links
1-3, 2-4, 5-7, 6-8 cannot abe removed because they
are situated within the switch.
1) T0-.../I1 up to 4 contact units
T3-.../I2 up to 5 contact units
2) T0 up to 8 contacts = 4 contact units,
T3 up to 12 contacts = 6 contact units
Moeller HPL0211-2001/2002
07/111
T Rotary Switches, TM Mini Rotary Switches
Ordering of Non-Standard Contact Sequences
Erstbestellung für Nockenschalter T Kombinationen
Initial order for a T rotary switch combination
Première commande de combinaisons de Commutateur T à cames
Auftrags-Nr.:
Order number:
N° de commande :
Position:
Item:
Poste :
Büro:
Office:
Bureau :
Bearbeiter:
Name:
Employé :
Kunde:
Customer:
Client:
Kundenspez.-Nr.:
Customer number:
N° client :
Datum:
Date:
Date :
Hinweis:
Note:
Note :
Stückzahl:
Quantity:
Quantité :
Schaltwinkel:
Type:
Type:
Anzahl Kontakte:
No. of contacts:
Nombre de contacts :
Bauform:
Mounting form:
Modèle :
Switching angle:
Angle de rotation : Réfèrence :
Die Anzahl der möglichen
Kontakte sowie die
q
30
q
TM
q
q
q
q
q
q
q
q
q✗
q
q
1
2
3
4
5
6
7
8
9
q
q
q
q
q
q
q
q
q
12
13
14
15
16
17
18
19
20
q✗
q
q
q
q
q
q
q
q
E
Kombinationsmög-
q✗ 45
q✗ T0
EA/SVB
EZ
q
q
EA/SVB-SW
EZ/OFS
lichkeiten mit den Baufor-
men entnehmen Sie bitte
dem Hauptkatalog.
DM/Stück:
DM/each:
q
q
60
q
q
q
T3
90
T5B
T5
I...
Prix unitaire :
I.../SVB
IVS
q
I.../SVB-SW
The number of possible
contacts as well as
possible combinations
with mounting forms are
shown in the Main
Catalogue.
V/SVB
X
q
q
V/SVB-SW
XZ
Z
Max. characters per switching angle on FS plate
Degrees
0.180
TM-E TM-EZ TM-IVS T0(3) T5(B)
10 q 21
11 q 22
q✗ + S-T0
5
8
6
5
5
4
5
7
5
5
4
4
6
4
4
3
1
4
13
8
13
8
Reportez-vous au
Catalogue Général pour
connaître le nombre
maximal de contacts et les
possibilités de combinai-
son selon les modèles.
q
+___________________
30, 210, 330
45, 135, 225, 315
60, 120, 240, 300
90, 270
6
7
5
7
4
8
7
150
8
Frontschild Nr.
Front Plate No.
Plastron N°
Baueinheiten/Contact units/Galettes
1
2
3
4
5
6
7
8
9
10
11
_______________
FS
Rundschaltung
Complete rotation
Rotation totale
k
autom. Rückzug
Spring-return
Retour autom.
k
✗
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43
0
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
330
30
60
90
300
270
240
315
45
225
210
135
120
150
180
Beschriftung
Marking/Repérage
Grad
1
3
5
7
9
11 13 15 17
19 21 23 25 27 29 31 33 35
20 22 24 26 28 30 32 34 36
37 39 41 43
38 40 42 44
Degrees/Degrés
2
4
6
✗ ✗ ✗ ✗ ✗ ✗
8
10 12 14 16 18
270
300
315
330
0
1
2
3
4
✗
✗
✗
✗ ✗
✗
✗
✗ ✗
30
45
✗
60
90
120
135
150
180
210
225
240
Key withdrawability with ..S-T0 or SVA-T3:
With SVA-T3, it is possible to switch
between Pos. 1 and 2 even after the
key has been withdrawn.
Pos. 1:
Pos. 2:
Pos. 3:
Pos. 4:
Key withdrawable
Key withdrawable
Key withdrawable
Key not withdrawable:
·
Schlüssel abziehbar
Key withdrawable
Retrait de la clé
Typ für Nachbestellungen (vom Werk auszufüllen)
Type for re-ordering (to be filled in by Factory)
Référence pour commandes ultérieures (à compléter par l’usine)
x
___________________________________
T
Moeller HPL0211-2001/2002
07/112
T Rotary Switches, TM Mini Rotary Switches
Ordering of Non-Standard Contact Sequences
Erstbestellung für Nockenschalter T Kombinationen
Initial order for a T rotary switch combination
Première commande de combinaisons de Commutateur T à cames
Auftrags-Nr.:
Order number:
N° de commande :
Position:
Item:
Poste :
Büro:
Office:
Bureau :
Bearbeiter:
Name:
Employé :
Kunde:
Customer:
Client:
Kundenspez.-Nr.:
Customer number:
N° client :
Datum:
Date:
Date :
Hinweis:
Note:
Note :
Stückzahl:
Quantity:
Quantité :
Schaltwinkel:
Type:
Type:
Anzahl Kontakte:
No. of contacts:
Nombre de contacts :
Bauform:
Mounting form:
Modèle :
Switching angle:
Angle de rotation : Réfèrence :
Die Anzahl der möglichen
Kontakte sowie die
q 30
q 45
q 60
q 90
q TM
q T0
q T3
q T5B
q T5
q 1
q 2
q 3
q 4
q 5
q 6
q 7
q 8
q 9
q 12
q 13
q 14
q 15
q 16
q 17
q 18
q 19
q 20
q E
q EA/SVB
q EZ
Kombinationsmög-
q EA/SVB-SW
q EZ/OFS
lichkeiten mit den Baufor-
men entnehmen Sie bitte
dem Hauptkatalog.
DM/Stück:
DM/each:
q I...
Prix unitaire :
q I.../SVB
q IVS
q V/SVB
q X
q I.../SVB-SW
The number of possible
contacts as well as
possible combinations
with mounting forms are
shown in the Main
Catalogue.
q V/SVB-SW
q XZ
q Z
Max. characters per switching angle on FS plate
Degrees
0.180
TM-E TM-EZ TM-IVS T0(3) T5(B)
q 10 q 21
q 11 q 22
q +____________________
q +____________________
5
8
6
5
5
4
5
7
5
5
4
4
6
4
4
3
1
4
13
8
13
8
Reportez-vous au
Catalogue Général pour
connaître le nombre
maximal de contacts et les
possibilités de combinai-
son selon les modèles.
30, 210, 330
45, 135, 225, 315
60, 120, 240, 300
90, 270
6
7
5
7
7
4
8
150
8
Frontschild Nr.
Front Plate No.
Plastron N°
Baueinheiten/Contact units/Galettes
1
2
3
4
5
6
7
8
9
10
11
_______________
FS
Rundschaltung
k Complete rotation
Rotation totale
autom. Rückzug
k Spring-return
Retour autom.
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
0
330
30
60
90
300
270
240
315
45
225
210
135
120
150
180
Beschriftung
Marking/Repérage
Grad
Degrees/Degrés
1
2
3
4
5
6
7
8
9
11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
270
300
315
330
0
30
45
60
90
120
135
150
180
210
225
240
Schlüssel abziehbar
Key withdrawable
Retrait de la clé
Typ für Nachbestellungen (vom Werk auszufüllen)
Type for re-ordering (to be filled in by Factory)
Référence pour commandes ultérieures (à compléter par l’usine)
x
__________________________
T
Moeller HPL0211-2001/2002
07/113
T Rotary Switches, TM Mini Rotary Switches
Ordering of Non-Standard Front Plates
Erstbestellung von Sonderfrontschildern
Initial ordering of non-standard front plates
Première commande de plastrons spéciaux
Auftrags-Nr.:
Order number:
N° de commande :
Position:
Item:
Poste :
Büro:
Office:
Bureau :
Bearbeiter:
Name:
Employé :
Kunde:
Customer:
Client:
Kundenspez.-Nr.:
Customer number:
N° client :
Stückzahl:
Quantity:
Quantité :
DM/Stück:
DM/each:
Prix unitaire :
Datum:
Date:
Date :
Non-standard front plates
Marking:
Front plate with black lettering
Insert text
Note the maximum number of characters allowed
outside the marked areas!
Type
q
FS-SOND-T0 (T3, P1)
Height of letters
ꢀ 2 characters
ꢁ 2 characters
4 mm
3 mm
q
FS-SOND-P3 (T5B, T5)
Height of letters
ꢀ 2 characters
ꢁ 2 characters
8 mm
5 mm
q
q
FS-SOND-TM-E
FS-SOND-TM-EZ
Height of letters
ꢀ 2 characters approx.
ꢁ 2 characters
3.5 mm
3 mm
For P1 and P3 complete only the 270° and 0° positions
Max. number of characters possible
Item
Degrees
0, 180
TM-E TM-EZ T0/P1 T5/P3
Dimensions
5
8
5
7
5
5
4
4
13
8
13
8
Type
Size of front plate
30, 210, 330
45, 135, 225, 315 6
60, 120, 240, 300 5
6
7
TM-.../E
29 x 29 mm (for frame sizes 30 x 30)
29 x 29 mm (for frame sizes 30 x 30)
45 x 45 mm (for frame sizes 48 x 48)
84 x 84 mm (for frame sizes 88 x 88)
5
7
TM-.../EZ(-...)
T0, T3, P1
P3, T5, T5B
90, 270
150
5
4
4
7
8
8
Typ für Nachbestellungen (vom Werk auszufüllen)
Type for re-ordering (to be filled in by Factory)
Référence pour commandes ultérieures (à compléter par l´usine)
FS.....................................................................................
相关型号:
NP3S10201BS22
RESISTOR, METAL FILM, 0.25 W, 0.1 %, 25 ppm, 10200 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S10201DS22
RESISTOR, METAL FILM, 0.25 W, 0.5 %, 25 ppm, 10200 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S10201FS22
RESISTOR, METAL FILM, 0.25 W, 1 %, 25 ppm, 10200 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S11302FS22
RESISTOR, METAL FILM, 0.25 W, 1 %, 25 ppm, 113000 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S114R0BS22
RESISTOR, METAL FILM, 0.25 W, 0.1 %, 25 ppm, 114 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S13302CS22
RESISTOR, METAL FILM, 0.25 W, 0.25 %, 25 ppm, 133000 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S133R0BS22
RESISTOR, METAL FILM, 0.25 W, 0.1 %, 25 ppm, 133 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S18700CS14
RESISTOR, METAL FILM, 0.25 W, 0.25 %, 25 ppm, 1870 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S18700CS22
RESISTOR, METAL FILM, 0.25 W, 0.25 %, 25 ppm, 1870 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S20302CS22
RESISTOR, METAL FILM, 0.25 W, 0.25 %, 25 ppm, 203000 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S205R0BS22
RESISTOR, METAL FILM, 0.25 W, 0.1 %, 25 ppm, 205 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
NP3S20R30DA22
RESISTOR, METAL FILM, 0.25 W, 0.5 %, 25 ppm, 20.3 ohm, THROUGH HOLE MOUNT, AXIAL LEADED, ROHS COMPLIANT
VISHAY
©2020 ICPDF网 联系我们和版权申明