30W-40W  
DC-DC CONVERTERS  
Single and Triple Output Models  
Wide Input Ranges  
5V, 12V, 15V Outputs  
Pi Input Filters—Built-in EMI Suppression  
UL/CSA/VDE/EN Safety Standards  
850-1500V Input/Output Isolation  
Short-Circuit/Over-Voltage Protection  
Remote Load Sensing  
Remote Shutdown/Output Adjustment  
3”3” Six-Sided Metal Case  
2-Year Warranty  
700,000-Hour Minimum MTBF  
Nominal  
Input  
Max.  
CHARACTERISTICS  
Input Voltage  
DC  
Output Output Line/  
Min.Nom.Max. Current Output Current Voltage Load Effi-  
EMI Suppression..........................Pi input filter, standard.  
Base-Plate Temperature...............Operating temperature of +100°C,  
max.with built-in thermal shutdown.  
Model  
(V) (V) (V)  
(A) Output(V)  
(A) Tolerance Reg. ciency  
DC-DC 30W Singles  
Isolation Voltage...........................D-input models: 1500V, input to output,  
HD1-30-5A  
HD1-30-5B  
HD1-30-5D  
9.0 12 25  
18 24 36  
36 48 75  
3.16 V1 5.0  
1.52 V1 5.0  
0.75 V1 5.0  
6.00  
6.00  
6.00  
1.0% 0.3% 79%  
1.0% 0.3% 82%  
1.0% 0.3% 83%  
for one minute. A- and B-input models:  
850V, input to output, for one minute.  
Output Adjustment........................Primary output adjustable 10%.  
Continuous Output Power............HD1-30 and HD3-30 total output  
power should not exceed 30W. HD1-  
HD1-30-12A 9.0 12 25  
HD1-30-12B 18 24 36  
HD1-30-12D 36 48 75  
3.09 V1 12  
1.51 V1 12  
0.75 V1 12  
2.50  
2.50  
2.50  
1.0% 0.3% 81%  
1.0% 0.3% 83%  
1.0% 0.3% 83%  
40 and HD3-40 total output power  
should not exceed 40W. Maximum  
output current for individual outputs of  
HD1-30-15A 9.0 12 25  
HD1-30-15B 18 24 36  
HD1-30-15D 36 48 75  
3.01 V1 15  
1.51 V1 15  
0.73 V1 15  
2.00  
2.00  
2.00  
1.0% 0.3% 83%  
1.0% 0.3% 83%  
1.0% 0.3% 86%  
triple output models appear in the rat-  
ings table.  
Minimum Load Requirement........Single output models, no minimum.  
DC-DC 30W Triples†  
Triple output models, 150 mA, mini-  
mum on 5V output, 50 mA, minimum,  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 78%  
2.5% 6.0%  
on auxiliary outputs.  
HD3-30-1A  
HD3-30-1B  
HD3-30-1D  
HD3-30-2A  
HD3-30-2B  
HD3-30-2D  
9.0 12 25  
18 24 36  
36 48 75  
9.0 12 25  
18 24 36  
36 48 75  
3.21 V2 +12 0.50  
V3 - 12 0.50  
Output Noise and Ripple..............5V output, 50 mVpp, maximum. 12V  
and 15V outputs, 75 mVpp, maxi-  
mum. (See Note 2.)  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 81%  
2.5% 6.0%  
Short-Circuit Protection ................Cycle-by-cycle current limiting.  
Over-Voltage Protection ...............V1 output only: 125% of rated output,  
typical. Single output models with 5V  
1.54 V2 +12 0.50  
V3 - 12 0.50  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 82%  
2.5% 6.0%  
outputs and all triple output models  
0.76 V2 +12 0.50  
V3 - 12 0.50  
have latching OVP; RESET = 0V. All  
other models are diode protected.  
Under-Voltage Lockout.................Nom. Input  
Off (Typ.) On (Typ.)  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 78%  
2.5% 7.0%  
3.21 V2 +15 0.40  
V3 - 15 0.40  
12V  
24V  
48V  
7.5V  
16.5V  
34.0V  
8.5V  
17.5V  
35.5V  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 81%  
2.5% 7.0%  
Transient Response .....................200 µs recovery after half-load to full load  
step change to within 1% of the regulation  
band with no more than 5% deviation.  
Frequency of Operation ...............300 kHz.  
Remote Shutdown........................CMOS and open-collector TTL com-  
patible: ON = 2.4V to VIN(MAX); OFF  
= 0.8V or less. Logic reference is -VIN.  
Temperature Range......................-40°C to +85°C (ambient). See  
Package Power De-Rating graph.  
1.54 V2 +15 0.40  
V3 - 15 0.40  
V1 5.0  
6.00  
1.0% 0.3%  
2.5% 5.0% 82%  
2.5% 7.0%  
0.76 V2 +15 0.40  
V3 - 15 0.40  
DC-DC 40W Singles  
HD1-40-5A  
HD1-40-5B  
HD1-40-5D  
9.0 12 25  
18 24 36  
36 48 75  
4.20 V1 5.0  
2.03 V1 5.0  
1.00 V1 5.0  
8.00  
8.00  
8.00  
1.0% 0.3% 79%  
1.0% 0.3% 82%  
1.0% 0.3% 83%  
Temperature Coefficient ............... 0.02%/°C over the entire operating  
temperature range.  
Relative Humidity .........................0 to 95%, non-condensing.  
Altitude .........................................0 to 10,000 feet.  
Cooling .........................................Convection cooling is adequate.  
Moving air is recommended for opera-  
tion in a confined area. See Package  
Power De-Rating graph.  
HD1-40-12A 9.0 12 25  
HD1-40-12B 18 24 36  
HD1-40-12D 36 48 75  
4.12 V1 12  
2.01 V1 12  
1.00 V1 12  
3.33  
3.33  
3.33  
1.0% 0.3% 81%  
1.0% 0.3% 83%  
1.0% 0.3% 83%  
HD1-40-15A 9.0 12 25  
HD1-40-15B 18 24 36  
HD1-40-15D 36 48 75  
4.02 V1 15  
2.01 V1 15  
0.97 V1 15  
2.67  
2.67  
2.67  
1.0% 0.3% 83%  
1.0% 0.3% 83%  
1.0% 0.3% 86%  
Storage Temperature....................-40°C to +100°C.  
HD3-30 models with tightly regulated auxiliary outputs are available. For more  
information, contact Power General applications engineering.  
Storage Humidity..........................0 to 95%, non-condensing.  
Mean Time Between Failures.......>700,000 hours. (See Note 4.)  
POWER  
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com  
GENERAL  
47  
30W-40W  
DC-DC CONVERTERS  
PACKAGE POWER DE-RATING  
Nominal  
Input  
Max.  
— Flat Base Plate —  
Input Voltage  
DC  
Output Output Line/  
Min.Nom.Max. Current Output Current Voltage Load Effi-  
Model  
(V) (V) (V)  
(A) Output(V)  
(A) Tolerance Reg. ciency  
DC-DC 40W Triples†  
V1 5.0  
8.00  
1.0% 0.3%  
HD3-40-1A  
HD3-40-1B  
HD3-40-1D  
9.0 12 25  
18 24 36  
36 48 75  
4.27 V2 +12 0.50  
V3 - 12 0.50  
2.5% 5.0% 78%  
2.5% 6.0%  
V1 5.0  
8.00  
1.0% 0.3%  
2.5% 5.0% 81%  
2.5% 6.0%  
2.06 V2 +12 0.50  
V3 - 12 0.50  
V1 5.0  
8.00  
1.0% 0.3%  
2.5% 5.0% 82%  
2.5% 6.0%  
1.02 V2 +12 0.50  
V3 - 12 0.50  
V1 5.0  
8.00  
1.0% 0.3%  
HD3-40-2A  
HD3-40-2B  
HD3-40-2D  
9.0 12 25  
18 24 36  
36 48 75  
4.27 V2 +15 0.40  
V3 - 15 0.40  
2.5% 5.0% 78%  
2.5% 7.0%  
PACKAGE POWER DE-RATING  
— Cross-Cut Heat Sink —  
V1 5.0  
8.00  
1.0% 0.3%  
2.5% 5.0% 81%  
2.5% 7.0%  
2.06 V2 +15 0.40  
V3 - 15 0.40  
V1 5.0  
8.00  
1.0% 0.3%  
2.5% 5.0% 82%  
2.5% 7.0%  
1.02 V2 +15 0.40  
V3 - 15 0.40  
HD3-40 models with tightly regulated auxiliary outputs are available. For more  
information, contact Power General applications engineering.  
30W AND 40W HD SERIES  
A. Dimensions shown are in inches.  
B. Tolerances = 0.00 0.01 inch.  
0.000 0.005 inch.  
C. HD1-40 and HD3-40 models are normally supplied with a flat base plate. To  
specify an HD1-40 or HD3-40 model with the optional cross-cut heat sink,  
add the letter “H” to the end of the part number (e.g., HD1-40-5AH).  
D. Module weight:  
HD1-30, HD3-30, HD1-40 and HD3-40, no heat sink = 4 oz. (113g).  
HD1-40 and HD3-40 with cross-cut heat sink = 5 oz. (142g).  
Pin-Out  
Pin  
1
HD1-30/HD1-40  
- VIN  
HD3-40/HD3-40  
- VIN  
2
+VIN  
+VIN  
3
Case  
Case  
4
5
6
Remote On/Off  
Output Adjust  
+V1OUT  
Remote On/Off  
Output Adjust  
V1OUT  
7
- V1OUT  
Return  
8
+Sense  
V2OUT  
9
- Sense  
V3OUT  
Notes  
1. Use of an external input line fuse is recommended:  
For HD1-30 and HD3-30 models with 12V input, use an  
6.0A/125V slow-blow fuse.  
2. Peak-to-peak and RMS metering equipment must have a  
20 MHz frequency response with probes and cables that  
maintain a frequency response of 20 Hz to 20 MHz.  
Output ripple and spikes are measured directly at the out-  
put terminals of the dc-to-dc converter with a 0.1 µF  
ceramic capacitor. The instruments’ probe ground bands  
must make direct contact with the output return pin or the  
common terminal of the converter in order to prevent erro-  
neous noise measurements.  
Output Adjustment  
For HD1-30 and HD3-30 models with 24V input, use a  
3.0A/125V slow-blow fuse.  
For HD1-30 and HD3-30 models with 48V input, use a  
2.0A/125V slow-blow fuse.  
For HD1-40 and HD3-40 models with 12V input, use an  
8.0A/125V slow-blow fuse.  
For HD1-40 and HD3-40 models with 24V input, use a  
4.0A/125V slow-blow fuse.  
3. All measurements are at nominal input, full load, and  
+25°C unless otherwise specified.  
For HD1-40 and HD3-40 models with 48V input, use a  
2.0A/125V slow-blow fuse.  
4. MTBF is calculated using the parts stress method in MIL-  
HDBK 217F (ground benign, T = +25°C).  
A
POWER  
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com  
GENERAL  
48  

相关型号:

HD1-40-12B1

Analog IC
ETC

HD1-40-12B2

Analog IC
ETC

HD1-40-12BH

Analog IC
ETC

HD1-40-12C

Analog IC
ETC

HD1-40-12C1

Analog IC
ETC

HD1-40-12C2

Analog IC
ETC

HD1-40-12D1

Analog IC
ETC

HD1-40-12D2

Analog IC
ETC

HD1-40-12DH

Analog IC
ETC

HD1-40-15A1

Analog IC
ETC

HD1-40-15A2

Analog IC
ETC

HD1-40-15AH

Analog IC
ETC