HA6025-E [ETC]
;型号: | HA6025-E |
厂家: | ETC |
描述: |
|
文件: | 总3页 (文件大小:48K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
Featuring state-of-the-art Surface
• Zero Voltage and Random
Turn-On Sw itching
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
• Panel Mount
• 1200V Blocking Capability
• 600Vac - the preferred
choice in Canada
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
AC CONTROL
DC CONTROL
HA6025
HD6025
HA6050
HD6050
HA6090
HD6090
HA60125
HD60125
M O DEL NUM BERS
➀
OUTPUT SPECIFICATIONS
Nominal Line Voltage (±10% ) [Vrms]
Operating Voltage Range (47-63 Hz) [Vrms]
Max. Load Current ➂ [Arms]
600
48-660
25
600
48-660
50
600
48-660
90
600
48-660
125
Min. Load Current, [mArms]
40
40
40
150
Transient Overvoltage [Vpk]
1200
250
1.7
1200
625
1.7
1200
1,200
1.7
1200
1,750
1.7
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R ) [˚C/W]
1.02
260
5
0.63
1,620
5
0.28
6,000
5
0.22
12,700
5
θJC
2
2
Maximum I t for Fusing, (8.3 msec.) [A sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms] ➆
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
Max. Turn-On Time ➄
500
500
500
500
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
DC CONTROL
AC CONTROL
AC CONTROL
( D P R E F I X )
( A P R E F I X ) ➃
( E S U F F I X )
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
3-32 Vdc
-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
---
---
3.0 Vdc
90 Vrms
18 Vrms
4.0 Vrms
9.0K Ohms
1.0 Vdc
10 Vrms
See Note ➅
2.0 mA➅
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms
©1998 CRYDOM CORP, Specifications subject to change without notice.
G E N E R A L N O T E S
➀ All parameters at 25ºC unless otherwise specified.
➁Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃24 Vac Input option, E suffix.
➄Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➅Input circuitry incorporates active current limiter.
For recommended applications and more information contact:
➆ No internal snubber.
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 1 OF 3
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
4000 Vrms
109 Ohm
8 pF
Ambient Operating Temperature Range
Ambient Storage Temperature Range
-40 to 80ºC
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA6025E
1.10
(27.9)
MOUNTING
HOLE/SLOT
8-32 TERMINAL
(2 PLACES )
.45
(11.4)
0.17 (4.3) DIA.
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD6090-10
OUTPUT
2.30
(58.4)
1
2
1.87
(47.5)
F
Faston Terminals (Up to 50 Amp Models)
SOLID-STATE RELAY
1.70
(43.2)
--
+
4
3
INPUT
1.00
.78
BASE PLATE
.125 (3.2)
(25.4)
6-32 TERMINAL
(2 PLACES)
(19.8)
.90
(22.9)
1.80
(45.7)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
1.10
FASTON TERMINAL
.250 X .032 (2 PLCS.)
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.87 REF.
(22.2)
.45
(11.4)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
1
2
OUTPUT
2.30
(58.4)
1.87
(47.5)
1.70
(43.2)
INPUT
4
3
Crydom Heat Sinks offer excellent
thermal management and are per-
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
.78
1.00
BASE PLATE
.125 (3.2)
FASTON
(19.8)
(25.4)
TERMINAL
.187 X .032
(2 PLCS.)
.90
(22.9)
1.80
(45.7)
All dimensions are in inches (millimeters)
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
APPROVALS
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
UL E116950
CSA LR81689
VDE 10143 UG
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 2 OF 3
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
CU RREN T D ERA TIN G CU RVES
25A
50A
30
25
20
15
10
5
95
60
40
20
0
.5ºC/W
1ºC/W
2ºC/W
90
1ºC/W
100
3ºC/W
1.5ºC/W
100
110
120
2ºC/W
110
120
NO HEATSINK
NO HEATSINK
10 20 30 40 50 20 40 60 80
0
5
10 15 20 25 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ºC]
Load Current [Arms]
Max Ambient Temp. [ºC]
90A
125A
90
.2ºC/W
.4ºC/W
120
80
40
0
160
120
80
90
.5ºC/W
1ºC/W
.4ºC/W
.2ºC/W
100
.5ºC/W
100
110
120
1ºC/W
110
120
40
0
20 40 60 80
Load Current [Arms]
0
20 40 60 80
Max Ambient Temp. [ºC]
30 60 90 120
Load Current [Arms]
0
20 40 60 80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
FastFax Document No.159
SERIES HA/HD60.032698, PAGE 3 OF 3
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com
相关型号:
HA6025EF-10
Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM
HA6025EFG-10
Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM
HA6025EFGH-10
Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM
HA6025EFP-10
Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM
HA6025EFPGH
Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM
©2020 ICPDF网 联系我们和版权申明